NQ, NF, I-Line, and QMB Panelboard Products. Reliable, Versatile, and Convenient Solutions

Similar documents
Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation

Secondary Unit Substations

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

Distribution Dry Type Transformers

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

MCC Ratings. Voltage Rating

Square D Safety Switches

ASCO SERIES 185 Power Transfer Switches

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

Corner-Grounded Delta (Grounded B Phase) Systems

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Equipment. Metering. Metering Equipment 1. Contents

LCP Coordination Panel Operations & Maintenance Manual Table of Contents

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Zenith Series MDU & RDU. Critical Power Distribution Units

Switchboards DE6 SWITCHBOARDS. Selection Guide. MDS Switchboard. QED Switchboard DE6-1. Description

8146/5 Series Breaker Panelboards

Cable Limiters. Increase System Reliability Decrease Downtime PRODUCT GUIDE

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

SURGELOGIC TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

Continuous Power... Continuous Protection

Contractors Guide Central Inverter System Installation

Overcurrent Protection

Simple Electrical Utility Cost Allocation Solutions

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Distribution Boards & Consumer Units

MERSEN. Safety & Reliability for Electrical Power

Retail Reference Guide Answers for infrastructure.

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Reverse-feed applications for circuit breakers

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

NEHB Panelboards Main Lugs and Main Circuit Breaker Replacement Parts

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution

Top Commercial / Residential Electrical Requirements *

GE Power Controls. MiniFORM Switchboards

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Cable/Conduit Conversion

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Surgelogic Surge Protective Device (SPD)

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

PX100 MBP with Configurable Distribution

NQ Circuit Breaker Panelboards

Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings

Iso-Gard Series 6 Line Isolation Monitors

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors

Quality and Innovation for Global Solutions

Section 10 Electric Switchboards: 0 Through 600 Volts

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Phone: Fax: Web: info@clrwtr.com

Circuit Breakers. Next Generation of Protection Capabilities

Mission Critical Data Center Systems

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

Applications. Remote Display Mounting Kits

SECTION LOW VOLTAGE LIGHTING CONTROLS

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training Eaton Corporation. All rights reserved.

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Universal MATE-N-LOK Connector System

Square D Powerlink G3 Lighting Control Systems

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Surgelogic Surge Protection Device EMA, EBA, and HWA Series

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

APC 3Phase Power Distribution

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Power Management Module 2. Installation

Power-Style Switchboards. Speed-D Switchboards. Low Voltage Switchgear. Medium Voltage Switchgear. Unit Substations. MV Overhead Distribution

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

QUESTIONS and ANSWERS RFB , Metal Clad Switchgear and Power Control Room

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

SmartVFD HVAC and BYPASS

MCR1900 Media Converter 19-Slot Chassis

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Installation and Operation Guide for PD4000 Series Power Control Center

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Requirements for Electrical Installations

CAEN Automation Enclosures

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Tmax MCCBs. Molded case circuit breakers. Tmax

CUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH _0_000

CITY OF LOS ANGELES CALIFORNIA

Transcription:

NQ, NF, I-Line, and QMB Panelboard Products Reliable, Versatile, and Convenient Solutions TM

Square D Panelboard Family Developed with extensive input from electrical contractors, Square D panelboards are built to last, easy to install, and are designed for optimum space and labor savings. Supported by the largest distribution, sales, and service organization in the industry, Square D panelboards are readily available to meet the needs of contractors, consultants, and end-users. Application Commercial Industrial OEM Utility Residential NQ Schools/ Universities Public Buildings Restaurants Strip Malls Hospitals Factories Chemical Plants Water Treatment Plants Computer Power HVAC Equipment Rooms Municipal Water/ Wastewater High-Rises Apartments Duplexes Hotels/Motels Nursing Home NF High Bay Lighting Shopping Malls Office Buildings Automotive Refineries Textile Mills Wastewater Treatment Plants Integrated Generator IEnclosures Equipment Rooms Power Generation Municipal Water/Wastewater I-Line Combo Panelboard Office Builders Strip Malls Retail Stores Grocery Stores Automotive Paper Mills Hospitals Factories HVAC Equipment Rooms Power Generation Nursing Homes I-Line Office Buildings Strip Malls Retail Stores Grocery Stores Automotive Paper Mills Hospitals Factories HVAC Equipment Rooms Power Generation Nursing Homes QMB Strip Malls Retail Stores Grocery Stores Automotive Manufacturing Refineries Textiles Food Service Industry Equipment Rooms Power Generation Product table Features NQ NF Column Width NQ NF I-Line Combo Panelboard I-Line QMB AC Voltage (max) 240 600Y/347 240 600Y/347 600Y/347 600 600 DC Voltage (max) 48 48 250 250 Main Device Amps (max) 600 600 225 225 1,200 1,200 800 Main Lugs Amps (max) 600 800 225 225 1,200 1,200 1,600 SCCR kaic (max) 65 65 225 225 65 200 200 Plug-On/Bolt-On Branch Both Both Both Both Both Plug Plug Top or Bottom Feed Yes Yes Yes Yes Yes Yes Yes UL and cul Service Equipment Yes Yes Yes Yes US Only Yes Yes Enclosure 1, 3R, 4/4X, 5, 12 1, 3R, 4/4X 5, 12 1 1 1, 3R, 4/4X, 5, 12 1, 3R, 4/4X, 5, 12 1, 3R, 4/4X, 5, 12 2

NQ Lighting Panelboards 240 Vac Maximum The NQ Lighting panelboards are designed to meet the evolving needs of customers with electrical lighting and distribution applications. The innovative designs increase the availablity and adaptability of these panelboards by offering complete ready-to-install kits. Available Interiors 3P4W and 1P3W available Maximum 600 A Main Breaker or Main Lug available 18, 30, 42, 54, 72, and 84 circuits Main breaker or main lugs 10,000, 22,000, and 65,000 fully rated branches at 208Y/120 Vac Series ratings to 200,000 A at 208Y/120 Vac Type 2 (Driphood) Type 3R (Outdoor, Rain, and Sleet protection) Type 4/4X (Stainless, corrosion protection) Type 5 (Settling dust and dripping liquids protection) Type 12 (Circulating dust and dripping liquids protection) Surface and flush non-vented Mono-Flat trims for 250 A and below Surface and flush screwed-to-box vented for 400 A and above Hinged trim available; meets door-in-door specs Separate trim not required for Type 3R, 4, 4X, 5, and 12 enclosures Available Options NQ panelboards meet 240 Vac applications and accept both the QO plug-on and QOB bolt-on circuit breakers. Copper bussing, copper lugs, copper neutrals Copper and aluminum, mechanical and crimp lugs Rail and dead front extension kits providing space only for future addition of ready-to-install kits (extensions of 6, 12, and 18 available) Increased side gutters 3, 6, and 12 Split bus Contactors Equipment space Locks (most common brands) In-line surge suppression Sub-feed lugs* Sub-feed breakers* Feed-through lugs* 200% neutrals* * Field-installable 3

NF Lighting Panelboards 600Y/347 Vac Maximum The NF panelboard offers superior performance and application flexibility for commercial and industrial electrical systems up to 600Y/347 Vac. This versatile lighting and power distribution panelboard features a wide selection of circuit breakers, accessories, and ready-to-install kits, as well as 200% rated neutrals for non-linear loads. Available Interiors 3P4W and 1P3W available Maximum 800 A Main Breaker or Main Lug available 18, 30, 42, 54, 66, and 84 circuits Main breaker (600 A) or main lug (800 A) Fully rated branches: 480Y/277 Vac: 18,000 A, 35,000 A, and 65,000 A 600Y/347 Vac: 14,000 A, 18,000 A, and 35,000 A Series Ratings 480Y/277 Vac: 200,000 A maximum 600Y/347 Vac: 200,000 A maximum Type 2 (Driphood) Type 3R (Outdoor, rain and sleet protection) Type 4/4X (Stainless, corrosion protection) Type 5 (Settling dust and dripping liquids protection) Type 12 (Circulating dust and dripping liquids protection) Surface and flush non-vented Mono-Flat trims for 250 A and below Surface and flush screwed-to-box vented for 400 A and above Hinged trim available; meets door-in-door specs Separate trim not required for Type 3R, 4, 4X, 5, and 12 enclosures NF panelboards offer application flexibility for commercial and industrial electrical systems up to 600Y/347 Vac. Available Options Copper bussing, copper lugs, copper neutrals Copper and aluminum, mechanical and crimp lugs Rail and dead front extension kits provide space only for future addition of ready-to-install kits (extensions of 6, 12, and 18 available) Increased side gutters 3, 6, and 12 Split bus Contactors Equipment space Locks (most common brands) In-line surge suppression Sub-feed lugs* Sub-feed breakers* Feed-through lugs* 200% neutrals* * Field-installable 4

I-Line Combo Panelboards 600Y/347 Vac Maximum The new Square D I-Line Combo Panelboard will change the way you install panelboards. Its simple, flexible, and innovative design uses a smaller footprint and delivers significant savings on installation time, labor expenses, and materials costs. Available Options Available Interiors: 3P4W, 3P3W, 1P3W, and 1P2W available A wide variety of customizable assemblies are available for field or factory installation. The I-Line Combo Duplex Panelboard, with optional mounting space, provides the capability for future site growth. 1,200 A main circuit breakers or 800 A main lugs Single or Duplex configurations available 18 or 22.5 of I-Line mounting space; up to 54 available lighting circuits 22.5 or 31.5 of I-Line mounting space; up to 84 lighting circuits 22.5 or 31.5 of I-Line mounting space; up to 54 lighting circuits and optional mounting space for customizable assemblies Fully rated and series rated systems available Type 2 (Driphood) Type 3R (Outdoor, Rain, and Sleet protection) Type 4/4X (Stainless, Corrosion protection) Type 5 (Settling dust and dripping liquids protection) Type 12 (Circulating dust and dripping liquids protection) Standard trims available (door not included) Four-piece Surface or Flush construction Optional four-piece trim with door Accessories Plated copper or aluminum bus 6, 9, or 12 box extensions 14 side car enclosures Optional 200% rated neutrals through 1,200 A Communication capabilities available with use of PowerPact with Micrologic Trip Unit circuit breakers Ready-to-Install Kits Dual 18-circuit section assembly Single 18-circuit section with contactor mounting assembly Additional 42-circuit section assembly Contactor mounting kit for up to three contactors Factory Assembled Options* Powerlink lighting section in 42 or 54 circuit configurations * Options listed above for ready-to-install configurations can be ordered as cable fed factory assembled configurations. 5

I-Line Power Panelboards 600 Vac Maximum The I-Line power distribution panelboard is the most versatile on the market and features the Schneider Electric unique breaker engagement system. It is used to feed NQ and NF lighting and appliance panelboards and is capable of feeding large motor loads. Wherever electricity is distributed or controlled, you ll find I-Line Power Panelboards. Available Interiors: 3P4W, 3P3W, 1P3W, and 1P2W available 1,200 A main circuit breaker or main lugs Up to 108 inches of I-Line circuit breaker mounting space Fully rated and series rated systems available Type 2 (Driphood) Type 3R (Outdoor, Rain, and Sleet protection) Type 4/4X (Stainless, Corrosion protection) Type 5 (Settling dust and dripping liquids protection) Type 12 (Circulating dust and dripping liquids protection) Standard trims available (door not included) Four-piece Surface or Flush construction Optional four-piece trim with door The industry exclusive I-Line stacked bus structure was designed with the installer in mind ensuring simple and quick breaker installation. Available Options A wide variety of accessories are available for field or factory installation of I-Line power panelboards. Plated copper or aluminum bus Sub-feed or through-feed lugs through 1,200 A 6, 9 or 12 box extensions Split bus bar Optional 200% rated neutrals through 1,200 A Optional customer metering with PowerLogic power meters or circuit monitors 100,000 A to 240,000 A plug-on SPD modules Six circuit QO 240 V plug-in distribution module Ground fault protection available on main or branch circuit breakers 6

QMB Power Panelboards 600 Vac Maximum When specifications or electrical codes call for a fusible panelboard, the QMB family offers unbeatable performance and time-saving installation features. The QMB power distribution panelboard feeds motors, transformers, and lighting systems. Available Interiors: 600 Vac, 250 Vdc maximum Maximum main lugs 1,200 A Maximum main switch 800 A Fusible switches are rated for 200 K RMS symmetrical amperes with appropriate Class J, L, R, or T fuses installed Branch devices include 30 A 800 A fusible switches, 15 A 400 A circuit breakers Type 3R (Outdoor, Rain, and Sleet protection) Four-piece, surface Fuse Selection Guide for Main and Branch Switches UL Class Voltage Ampere Ratings AIC Fuse Type Loads H 600 V 1 600 A 10,000 A One-time Miscellaneous loads J 600 V 1 600 A 200,000 A Time-delay Motors, welders, etc. The reliability of the QMB power panelboard makes it the product of choice for large commercial and industrial applications. J 600 V 1 600 A 200,000 A Fast-acting Non-motor loads L 600 V 601 800 A 200,000 A Time-delay All type loads L 600 V 601 800 A 200,000 A Time-delay Non-motor loads RK1 600 V 1 400 A 200,000 A RK1 600 V 401 600 A 100,000 A RK5 600 V 1 400 A 200,000 A RK5 600 V 401 600 A 100,000 A Dual element time-delay Dual element time-delay Dual element time-delay Dual element time-delay All type loads All type loads Motors, welders, transformers Motors, welders, transformers T 600 V 1 800 A 200,000 A Fast-acting Non-motor loads 7

The Square D brand is an integral part of the Schneider Electric portfolio. As the global specialist in energy management, we deliver proven reliability, expertise, and comprehensive solutions. Ask your authorized distributor for more information, visit www.schneider-electric.com/us, or call 888-SQUARED. Schneider Electric USA 1415 S. Roselle Road Palatine, IL 60067 Tel: 847-397-2600 Fax: 847-925-7500 Schneider Electric Canada, Inc. 19 Waterman Avenue Toronto, ON M4B 1Y2 Tel: 416-752-8020 Fax: 416-752-6230 2013 Schneider Electric. All Rights Reserved. Schneider Electric, Square D, I-Line, PowerPact, Micrologic, Powerlink, Mono-Flat, and PowerLogic are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are the property of their respective owners. 998-1214618_US Document Number 0120BR9202R07/13 October 2013