Calibration and Maintenance Procedure: YSI Model 60 ph Meter

Similar documents
YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen

Appendix C. Vernier Tutorial

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

AIRMoN, ph and Conductivity Field Measurement

Chloride and Salinity

6 H2O + 6 CO 2 (g) + energy

ExStik TM ph Waterproof Meters

STANDARD OPERATING PROCEDURE Dissolved Oxygen Measurement, Meter Calibration and Maintenance

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Instruction Manual Temp 4/5/6 Temperature Meter Series

Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

ph 200 ph-/redox-/temperature Meter Operating instructions

Care and use guide. Contents. a handy solution made easy. page

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

SDS-PAGE Protocol Mutated from the SDS-PAGE protocol written by the Lord of the Flies

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

Shampoo Properties Evaluation General Science

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

PHOTOSYNTHESIS AND RESPIRATION

Cidex OPA Solution Training Checklist and Competency for Semi-Critical Medical Devices

Trace Dissolved Oxygen Sensor

Measuring the Conductivity of Pure Water Using USP<645>

18 Conductometric Titration

Relative Humidity Calibration Kit

Household Acids and Bases

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Chem 1B Saddleback College Dr. White 1. Experiment 8 Titration Curve for a Monoprotic Acid

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Milwaukee USER MANUAL

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Bluelab Soil ph Meter Instruction Manual

FG MOISTURE MONITOR Installation & Operation Manual

Underwater Housing for Sony RX100 III, RX100 IV

INTRODUCTION INTERLOCK KIT K-8110

INSTRUCTION MANUAL. Handy Polaris

4-Channel Thermometer / Datalogger

Instruction Manual. AWK-115S

HUMULIN 70/30 KwikPen

USEPA Electrode Method Method 8156

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Pro1030 USER MANUAL. English

Care and use guide. Contents. page

Experiment 17: Potentiometric Titration

Bottle Rockets. Vanderbilt Student Volunteers for Science. Fall 2008

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

PR 50 Frymaster Universal Holding Cabinet (UHC)

Enzyme Action: Testing Catalase Activity

Osmosis. Evaluation copy

User Manual Important: First read the Medication Guide that comes inside your FORTEO carton.

User Guide. Temperature and Humidity Datalogger. Model 42280

DURAS INFLATABLE BOAT OWNER'S MANUAL

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

OWNER S MANUAL Table Tennis Table Patent Pending

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Dissolved Oxygen Sensors

Temperature, Humidity & Dew Point Chart Recorder

Standard Operating Procedure

Interchangeable Cores

5800 Temperature Sensor Cable Assembly

Alfa Romeo 147 On board instruments installation guide

Neutralizing an Acid and a Base

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

ph Measurement and Control

Enzyme Pre-Lab. Using the Enzyme worksheet and Enzyme lab handout answer the Pre-Lab questions the pre-lab must be complete before beginning the lab.

Operations Manual. YSI 550A Dissolved Oxygen Instrument

DISSOLVED OXYGEN PROBE

After the reactor has been running and the air in the chamber has been purged the co2 can be introduced and the dial in process can begin.

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

Toroidal Conductivity Sensor

FRONT WINDSHIELD SEAL INSTALLATION

Operator Quick Guide EC SENSOR

Troubleshooting Polyacrylamide Gel Electrophoresis (PAGE)

Extraction: Separation of Acidic Substances

Operating Manual Color Changing Fountains

Making Biodiesel from Virgin Vegetable Oil: Teacher Manual

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

The Determination of an Equilibrium Constant

DYI INNOVA LIGHT BAR

Always Moving Forward. Operating Manual. Please Read Before Operating Unit. Models DSP1, DSP2 & DSP3 Stripping Pots

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

EEG Cap Instructions

Jupiter 8 Service. OR A TALE OF 4 JUPITER 8 s BY KIM COXON

Enzyme Action: Testing Catalase Activity 50 Points

CONFER ABOVE GROUND CURVE STEP / ABOVE GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

BUGGY SETUP GUIDE. Volume GOKARTSUSA GY6 150, CN250. Buggy Setup Guide

CDDFT - Health Call INR Monitoring Service. Health Call INR Monitoring Service. Patient Training

The Drink-Aide The NEW look of independence

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

Ski Machine Owner s Manual and Assembly Instructions

HOBO Dissolved Oxygen Logger (U26-001) Manual

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

Cooling Rewarming QUICK REFERENCE GUIDE. First change Target Temp. Always operate in Automatic Mode. Then change Warming Rate

Transcription:

Calibration and Maintenance Procedure: YSI Model 60 ph Meter These procedures are to be performed by program staff or people who have been trained by staff. Perform a 3-point calibration of the ph meters before every monitoring session. Replace buffer solutions as needed so as not to exceed expiration dates. Solutions are good until the last day of the month listed. Anytime a new lot number of buffer is put into use, calibrate the instruments with the new lot and check the old lot to be sure the results are similar (see below). Equipment Needed: ph Calibration Protocol & Data Sheets notebook YSI Model 60 ph Meters ph 7 & 10 buffer bottles from kits Purified water Kimwipes ph 4, 7 and 10 buffer solutions 3 100 ml graduated cylinders (Product manual for troubleshooting) Pre Season Maintenance and Calibration: 1. Perform 3-point calibration of each meter with office standards. (detailed instructions follow) Record lot #s and expiration dates on data sheet. 2. Indicate Y in the calibrated column if calibration was successful for each meter. 3. Test each freshly calibrated meter s field standards and record results. 4. If a new Lot # of ph buffer was put into use: After calibration, test the old lot of the corresponding buffer against the new lot with one of the successfully calibrate meters. Record results on the data sheet. End of Season ph Calibration Check: 1. Turn on and warm up all instruments. 2. Check and record readings of ph 7 and temp for each instrument in its kit ph 7 buffer. Do a 2 pt calibration per daily monitoring cal procedure using standards from the appropriate kit. 3. Pour fresh ph buffer solutions 4.0, 7.0 and 10.0 into appropriate cylinders (office standards). 4. Allow the instrument to stabilize and record the ph and temperature readings of each instrument in each of the 3 office standards. 5. Record the lot # and expiration date for each buffer used on the data sheet. Also date and samplers initials. Calibration: 1. Turn the instrument on. The instrument will activate all segments of the display for a few seconds, which will be followed by a self test procedure which will last for several more seconds. If LO BAT is displayed you will need to replace the batteries. Also, if the meter locks up, try replacing the batteries. When the meter is first turned on, it is in the ph mode and should display ph and C. If ph and temperature are not displayed, press MODE until you get to the right display on the screen. 2. If the probe is in the long-term storage bottle, remove it from this bottle and cap it (see last page for details). Or, if the probe is in the transport chamber in the meter, simply remove it from this 3. Rinse the probe with purified water, then carefully dry the probe using Kimwipes (or rinse it with some of the buffer solution to be used for calibration). (There is a bottle of old ph 7.00 buffer to soak 3-4 meters at once for 20 min. stabilization. Move to fresh buffer solution to calibrate.) YSI 60 maint-cal 1

4. Place 25mL of ph 7 buffer solution in a 100 ml graduated cylinder. Immerse the probe, making sure that both the ph and temperature sensors are covered by the solution. Let the probe sit in this solution for 20 minutes or until stable. than 7.00) will appear on the display when the probe is placed in the solution.] Figure of YSI Model 60 ph probe, showing temperature and ph sensor locations. Note that both sensors need to be submerged while measuring ph. 5. Once the reading is stable (doesn t vary by more than 0.01 for 2 min.), record the Unit#, date, and the ph 7 before calibration reading in the calibration notebook. 6. To enter the calibration menu, simultaneously press both the UP ARROW and DOWN ARROW keys. The display will show CAL at the bottom, STAND will be flashing and the main display will show 7.00 (the buffer you are using). 7. Setting the midpoint: a. Press the ENTER key. The screen will show CAL at the bottom, STAND will stop flashing and the ph calibration value is shown with the middle decimal point flashing. b. When the reading is stable (does not change by 0.01 ph in 10 seconds), the decimal point will stop flashing. Press and hold the ENTER key until SAVE along with OFS is displayed and the display returns to the main screen. SLOPE will now appear on the display and be flashing. This indicates that the slope is ready to be set using a second ph buffer. Leave the 7.00 ph buffer solution in the cylinder and set aside. c. I [Note: The meter automatically accounts for the fact that the true ph of the buffers changes with temperature; therefore, the ph values displayed during calibration will vary with temperature. For example, ph 7 buffer at 20 C (rather than 25 C) has an actual ph of 7.02, and this number (rather YSI 60 maint-cal 2

8. Setting the lower point: a. Rinse the probe with purified water, then carefully dry the probe. Put 25mL of ph 4 buffer in a different clean cylinder and immerse probe in the solution, making sure the temperature probe is immersed. b. Press ENTER. The screen will now show CAL at the bottom, and SLOPE will stop flashing and the ph 4 buffer value is shown with one of the decimal points flashing. It may read under for a while swish to ensure no bubbles on probes. c. When the reading stabilizes, the decimal point will stop flashing. Press and hold ENTER to save the first slope until SAVE is displayed along with SLP. d. SLOPE will start flashing again indicating that the slope is ready to be set using a third ph buffer. 9. Setting the upper point: a. Rinse the probe with purified water, then carefully dry the probe. Fill a clean cylinder with 25mL of ph 10 solution and immerse the probe into the solution, making sure the temperature sensor is immersed. b. Press ENTER. The screen will now show CAL at the bottom, SLOPE will stop flashing, and the ph value for the ph 10 buffer is shown with the right decimal point flashing. c. When the reading is stable, the decimal point will stop flashing. Press and hold ENTER until SAVE flashes on the display along with SLP to indicate the second slope value has been saved. d. The system is now calibrated at three points and will return to normal operation. e. Anytime you want to return to the main operating screen, simply press MODE. 10. Label the side of the meter with a piece of tape: Calibrated [date] [initials]. 11. If there is tape blocking the probe chamber opening, remove it. If the sponge inside is dry, wet it with a few drops of purified water. (If the sponge is grungy, replace it by cutting a new one.) Rinse the probe with purified water and insert it into the Calibration troubleshooting: 1. If possible, test the probe by letting it soak in room-temperature tap or creek water (NOT purified water) record how long it takes for the unit to get to a stable reading (not varying by more than 0.01 for 2 minutes) and what those readings are. If a unit takes >30 min. to stabilize, follow the cleaning procedures in the product manual. If these procedures YSI 60 maint-cal 3

fail to correct the problem, it may be time to replace the probe. 2. Either store the probe in ph 4 buffer, or dip the probe in ph 4 solution, shake off and place in the transport 3. If display reads undr or OVEr while calibrating, try letting it sit for a few minutes to see if the problem goes away. If not, try the probe cleaning procedures described in the product manual, followed if possible, by an over-night soak in ph 4 buffer solution. Meter troubleshooting: If the meter takes a long time to stabilize or fails to stabilize in the field, first try jiggling the probe in the cylinder or moving it up and down making sure there are no bubbles at the bottom of the probe. Follow the cleaning procedures in the product manual. If these procedures fail to correct the problem, it may be time to replace the probe. Buffer bottle for long-term ph probe storage (more than a week): Store the ph probe in ph4 buffer solution if it s not going to be used for more than a few days. Setup of this storage container (which comes from the manufacturer, except for the Velcro strips added by Streamkeepers) is depicted in the accompanying diagram. To set the probe in this bottle: 1. Slide the cap with the hole (the open cap ) up the probe, to just below the O- ring that s on the probe. 2. Roll the loose O-ring that comes with the storage bottle up the probe until it s under the open cap. 3. Fill the storage bottle to slightly below the shoulder with ph4 buffer solution. 4. Insert the probe into this bottle, and then screw the bottle up into the cap. (You may have to slide the cap down a bit to get the threads to engage.) With the O- ring inside, this seal should be watertight test it to make sure. 5. Attach the closed cap to the bottom of this bottle, using the Velcro to make it grip. 6. Store the unit out of the way, preferably with the probe facing straight down as in the diagram. Removing the probe from the storage bottle: To take the probe back out of the storage bottle and prepare it for further sampling: 1. Remove the closed cap from the Velcro at the bottom of the bottle. YSI 60 maint-cal 4

2. Holding the bottle upright, unscrew it from the cap with the hole ( open cap ) and screw the closed cap onto it. 3. Rinse the probe and open cap with distilled water. 4. Slide the open cap toward the cord to expose the O-ring beneath the cap. Roll off the O-ring, then slide the open cap off the end of the probe. 5. Smush the O-ring into the Velcro at the bottom as you press the open cap into it. Thus, the bottle, both caps, and O-ring are all stored together in a single package. 6. Remove the tape that s covering the probe chamber on the side of the meter, being careful not to lose the little sponge that s inside. 7. With the little sponge inside the chamber, add a few drops of purified water. 8. Put the probe all the way into this 9. (If possible, before sending the meter back out in the field, soak the probe in creek or tap water for 30 minutes before placing the probe in the meter s storage ) Always check amounts and dates for all Ph buffer solutions to ensure there is enough for the next calibration check. If not, notify staff. buffer probe velcro cap with hole velcro closed cap O-ring under cap Switch these caps when you remove the bottle from the probe Once you have finished calibrating the equipment, YOU are responsible for entering the new data into the database. Once the data has been entered, the database will automatically tell you if the instruments have passed their quality control criteria. Print this report and staple it to the front of the data sheet, 3-hole punch these pages and place them in the back of the calibration notebook behind the data sheet tab. Put the most recent data sheet on top. YSI 60 maint-cal 5