ASTRONOMICAL TIME SWITCH NFC Supported AR-02D-NFC (2 x 10A)

Similar documents
User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Multi-Range Programmable DC Power Supplies 9115 Series

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Drayton Digistat +2RF/+3RF

Smile. The All-In-One Heating Controller

Multi-Range Programmable DC Power Supplies 9115 Series

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Universal control module for motorized devices

HERZ-Thermal Actuators

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Heating Controller. Building Technologies HVAC Products

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

3-phase, bidirectional energy meter

T5000 T000 LCD Digital Fan Coil Thermostat

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Duct Humidity Transmitter

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

15 Series - Electronic step relay and dimmer. Features SERIE

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Three-phase monitoring relay CM-PFE

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Dyeing Programmer DP - 01

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Cisco Unified IP Phone Power Injector

SYNCHRONIZE DIGITAL CLOCK SYSTEM NETWORK DIGITAL CLOCK VER 1.0 DYNATEK

Multifunction devices

DC Electronic Loads 8500 series

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Quick Connect. quick - simple - efficient.

Inwall Room Temperature Unit

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

STERILIZERS, LABORATORY DRYING OVENS

OZW30. Central Unit SYNERGYR

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Emerson Smart Firewall

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Energy Communication Unit (ECU)

Installation & User Instructions

A project to optimise quality and energy efficiency must include metering

1. INTRODUCTION FEATURES 2. PROGRAMMING

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Monitoring,Telemaintenance,... HACCP. Innovative Supermarket solutions. Tecnologia ed Evoluzione

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

POWERED BY BLUE EARTH

TCR easy Plus Alarm. Operating Instructions

EARTH LEAKAGE PROTECTION: CONTENTS

Electronic Control Devices The European Product Catalogue 2007

OT 40L / 90L. Laboratory Steam Sterilizers

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

US Installation Manual Smappee Monitor

Pocket DAB & FM Radio with Speaker

PXM20-E. Operator unit DESIGO PX

Energy Communication Unit (ECU)

Fire Pump Controllers Remote Alarm Panels

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Flow Monitoring System

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Phase Modular Finally the benefits of Modular ups are for all

is then retained absolutely without interruption.

climote User Guide Version 1-0

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Electronic Control Devices The European Product Catalogue 2007

ATC-300 Automatic Transfer Switch Controller

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Technical Information RIA14

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

User manual Rev 1.3 Contents

Routefinder Testing and reporting for emergency lighting systems

iva Cable & Antenna Analyzer

Wireless Thermostats 230v and Battery Operated Instruction Manual

Blue Easy Reader Thermostat 1F95EZ Homeowner s Guide

USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

WD-AMX Water Detection Controllers

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

12 Series - Time switches 16 A. Features

Polyphase kwh Electricity Meter

Transcription:

ASTRONOMICAL TIME SWITCH NFC Supported AR-02D-NFC (2 x 10A) ATEL TEKNOLOJİ ve SAVUNMA SANAYİ A.Ş. ATEL TECHNOLOGIE and DEFENSE INDUSTRY Inc. Co. Hilal Mah. 677. Cad. No: 9 06550 Çankaya ANKARA / TÜRKİYE T : +90 312 441 42 20 F : +90 312 441 42 18

Astronomical Time Switch is a programmable switch to turn on electric utilities between sunset and sunrise accordingly to the geographical area of installation. APPLICATIONS: Street illuminations Road signs illuminations Shopping Center illuminations Parks/Garden illuminations Parking illuminations Luminous signboards (shops, etc) Home illuminations Other illumination applications GENERAL SPECIFICATIONS: Sunset and sunrise calculation precision (±1 min.) Daily automatic regulation of sunrise and sunset time Sunrise and sunset times offset feature up to ±9 hours 59 minutes Automatically switching on and off with coordinates as latitude-longitude data GMT time zone feature CET / DST automatic update and cancel option Program assignment for each day separately in a week All configuration can be monitored in tracking menu Sunset and sunrise times can be viewed on screen Password menu blocked no authorized person usage User-friendly English and Turkish Menu Low battery notice can be viewed on screen Day information can be viewed on screen with symbols Contact status can be viewed on screen CET / DST status can be viewed on screen Contacts can be used manual without program Can be programmed without energy Sleep mode Parameter update with NFC

PRE-SET PROGRAMS : The device is equipped with 6 pre-set programs that allows the user to program the device. These are P1, P2, P3, P4, P5 and P6 programs. New programs can be added for customer requirements. P1 Program is operating accordingly to astronomical time zone. The concerning contact is active between sunset and sunrise. In P2 program the concerning contact is passive all day. In P3 Program, the concerning contact is deactivated in the defined duration between sunset and sunrise. This time can be set from the P3 menu P4 Program brings the concerning contact after the sunset passive according to the concerning time. This time can be set from the P4 menu. P5 Program is the reverse of P4 program. P5 Program brings the concerning contact active after sunset according to the defined time until sunrise. P6 Program is the reverse of P3 Program. The concerning contact is activated in the defined duration between sunset and sunrise.

Program and Setting Update via NFC supported mobile device First and Unique in Turkey and in the World Program and setting update without remote control Program and setting update without energy Program Setting with ASTROID ateltek application with NFC (Near Field Communication) supported ANDROID Phone or tablet Date, Time and Coordinates setting automatically via GPS or manually by user Possible to make all settings with the mobile device Astronomical Time Switch program and setting update with mobile device without remote control TECHNICAL SPECIFICATIONS: Power Supply 230 VAC ±10%, 50/60 Hz Relay Output 10A/2500VA x 2 pcs Additional reserve 9~12 hours Battery / Battery Life CR2032 / 5 years Renewal 1 sec Display Size 1,45 LCD Dimension 2 DIN Time precision 1 sec/day Sunset and Sunrise Accuracy 1 min Operating Temperature -20 C / +60 C Storage Temperature -30 C / +70 C Installation DIN Rail or Wall mounting Protection Class IP 20 / IP 41 (Front Panel) Battery Replacement Other Specifications Sealable Button Cover Backlit LCD Display Parameter Update with NFC

CONNECTION DIAGRAM: DIMENSIONS:

REFERENCE STANDARDS: The device is designed under the following directives and is reported with the tests in accredited laboratories. 2004/108/EC Electromagnetic Compatibility (E.M.C.) o EN 60730-1 General Requirements o EN 60730-2-7 Automatic electrical controls for household and similar use 2006/95/EC Low Voltage Directive (LVD) o EN 60068-2-1 Environmental testing; Cold o EN 60068-2-2 Environmental testing; Dry heat o EN 60730-2-7 Automatic electrical controls for household and similar use DIN 43 880 Built-in equipment for electrical installations EN 62054 21 Particular requirements for time switches (Crystal controlled time switch test)