Determination of calcium and magnesium found in everyday multivitamins

Similar documents
Colorimetric Determination of Iron in Vitamin Tablets

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Determination of Aspirin using Back Titration

Determination of the Mass Percentage of Copper in a Penny. Introduction

Determination of caffeine and vitamin B6 in energy drinks by high-performance liquid chromatography (HPLC)

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Vitamin C quantification using reversed-phase ion-pairing HPLC

Stage 1 Desired Results

Calcium Analysis by EDTA Titration

Standard Test Method for Analysis of Barium, Calcium, Magnesium, and Zinc in Unused Lubricating Oils by Atomic Absorption Spectrometry 1

HS 1003 Part 2 HS 1003 Heavy Metals Test

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

Determination of the Amount of Acid Neutralized by an Antacid Tablet Using Back Titration

Analysis of Vitamin C Using Iodine. Introduction

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

Calculation of Molar Masses. Molar Mass. Solutions. Solutions

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

Carolina s Solution Preparation Manual

Experiment 7: Titration of an Antacid

EXPERIMENT 12: Empirical Formula of a Compound

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

The Empirical Formula of a Compound

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Lab 5: Quantitative Analysis- Phosphates in Water By: A Generous Student. LBS 171L Section 9 TA: Dana October 27, 2005

General Chemistry I (FC, 09-10) Lab #3: The Empirical Formula of a Compound. Introduction

Determination of calcium by Standardized EDTA Solution

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Solutions and Dilutions

Austin Peay State University Department of Chemistry CHEM Empirical Formula of a Compound

Molar Mass of Butane

BRIEFING Plastic Packaging Systems for Pharmaceutical Use.

= amu. = amu

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

TOTAL PROTEIN FIBRINOGEN

3 - Atomic Absorption Spectroscopy

Determination of Citric Acid in Powdered Drink Mixes

Element of same atomic number, but different atomic mass o Example: Hydrogen

Lab #11: Determination of a Chemical Equilibrium Constant

Chemical Calculations: The Mole Concept and Chemical Formulas. AW Atomic weight (mass of the atom of an element) was determined by relative weights.

XI. Methods of Analysis DETERMINATION OF POTASSIUM CARBONATE CALCULATIONS REAGENTS PROCEDURE

Synthesis of Aspirin and Oil of Wintergreen

SODIUM CARBOXYMETHYL CELLULOSE

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

OBJECTIVES: Visitors learn what an antioxidant is and how it behaves. They also learn how to test for the presence of vitamin C..

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

Coordination Compounds with Copper (II) Prelab (Week 2)

Chemistry 111 Laboratory Experiment 7: Determination of Reaction Stoichiometry and Chemical Equilibrium

Measuring Manganese Concentration Using Spectrophotometry

Phenolphthalein-NaOH Kinetics

ph: Measurement and Uses

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

Recovery of Elemental Copper from Copper (II) Nitrate

OLIVÉR BÁNHIDI 1. Introduction

Vitamin C Content of Foods

ERDOSTEINE - MONOGRAPH.

Concept 1. The meaning and usefulness of the mole. The mole (or mol) represents a certain number of objects.

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Determination of Metals in a 3% Sodium Chloride (NaCl) Matrix by Axially-Viewed ICP-OES

Analytical Chemistry Lab Reports

A Beer s Law Experiment

Unit 2: Quantities in Chemistry

Laboratory Procedure Manual

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

Chem 131A: Absorbance of Riboflavin

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

SPIKE RECOVERY AND DETERMINING A METHOD DETECTION LIMIT Pamela Doolittle, University of Wisconsin Madison, pssemrad@wisc.edu 2014

International Journal of Research and Reviews in Pharmacy and Applied science.

PART I: PREPARATION OF SOLUTIONS AND STANDARDIZATION OF A BASE

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

The Determination of an Equilibrium Constant

Ascorbic Acid Titration of Vitamin C Tablets This lab will be completed individually! Make sure you come prepared!

INTERNATIONAL OLIVE COUNCIL

Accurate Determination of Lead in Different Dairy Products by Graphite Furnace Atomic Absorption Spectrometry

Micronutrient. Functio. Vitamin A

To determine the mass of iron in one adult dose of either a ferrous sulfate or. ferrous gluconate iron supplement using a colorimetric technique.

Calcium , The Patient Education Institute, Inc. nuf40101 Last reviewed: 02/19/2013 1

Worked solutions to student book questions Chapter 7 Spectroscopy

Why are Vitamin and Mineral Supplements so Important Before and after Bariatric Surgery? 6/4/2014 1

Dissolving of sodium hydroxide generates heat. Take care in handling the dilution container.

Phosphorus, Reactive (Orthophosphate)

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

STANDARDIZATION OF A SODIUM HYDROXIDE SOLUTION EXPERIMENT 14

Complexometric Titration Analysis of Ca 2+ and Mg 2+ in seawater

Experiment 3 Limiting Reactants

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

Volumetric Analysis. Lecture 5 Experiment 9 in Beran page 109 Prelab = Page 115

OXIDATION-REDUCTION TITRATIONS-Permanganometry

SYMBOLS, FORMULAS AND MOLAR MASSES

Chapter 4. Chemical Composition. Chapter 4 Topics H 2 S. 4.1 Mole Quantities. The Mole Scale. Molar Mass The Mass of 1 Mole

CHEMICAL REACTIONS OF COPPER AND PERCENT YIELD KEY

IB Chemistry. DP Chemistry Review

Determination of the Sensitivity Range of Biuret Test for Undergraduate Biochemistry Experiments

TITRATION OF VITAMIN C

IN VITRO BINDING BIOEQUIVALENCE STUDY SUMMARY TABLES AND SAS TRANSPORT FORMATTED TABLES FOR DATASET SUBMISSION

Transcription:

Determination of calcium and magnesium found in everyday multivitamins Liz Blair and Spencer Knutson Department of Chemistry, Concordia College, 901 8 th St S, Moorhead, MN 56562 Abstract The amounts of calcium and magnesium in Centrum Ultra Men s and One Source Teen (OST) multivitamins were determined using standard additions and atomic absorption spectroscopy. Knowing the amounts of these metals in the multivitamins is important because adverse effects can result if too much or too little is contained in the pills. One of the main things that needed to be carried out with caution was the analysis of calcium. Lanthanum was needed to overcome matrix effects that were present due to the complexity of the ingredients in the multivitamins and the fact that calcium forms aluminum and phosphate complexes in an air/acetylene flame. The results correlated with those found by Arnold, et al. Introduction Multivitamins are taken by a wide variety of people throughout the world and they tend to contain a relatively large amount of various elements that are needed by the body (nutritionists referred to them as minerals). If companies did not monitor the amounts of the metals found in the vitamins they manufacture, it would be easier for consumers to reach the toxicity levels (or deficiency levels) and become very sick. The minerals that were looked at play important roles throughout the body. Calcium helps in mineralization of bones and teeth; it is also involved in muscle contraction and relaxation, nerve functioning, blood clotting, and blood pressure. Magnesium partakes in energy transfer and helps transform adenosine diphosphate to adenosine triphosphate. The RDA has determined, through their research, specific recommended daily intakes (RDI s) and tolerable upper intake levels (UI s). These factors are what determine the safe amount of each mineral that can be added to a multivitamin. 3 Minerals are not the only things in a multivitamin s composition; vitamins, binders, and artificial coloring are also added to the makeup. The multivitamin s composition provided us with problems due to complex matrix effects that needed to be overcome when preparing the samples. The atomic absorption (AA) spectrophotometer uses an argon filled hollow cathode lamp which helps in determining the amount of particles of a specific element in the sample. The AA, with the help of standard additions and lanthanum additions, help in overcoming these complex matrix effects. Lanthanum is needed because calcium readily reacts with phosphates and aluminum when using an air/acetylene flame in the AA. The addition of lanthanum causes the calcium to be released from the phosphate or aluminum complex and takes its place so the calcium can be read by the instrument. 2 1

Experimental The procedure reported by Arnold and Arndt was carried out according to the following. 1 Two standard solutions for the elements Mg 2+ (Ricca) and Ca 2+ (Fisher) were prepared by obtaining 1000 ppm stock solutions of each element and then diluting each 10:1 with 0.1 M HNO3 to form 100 ppm standard. Trace metal grade nitric acid (Fisher) diluted to 0.1 M was used for all dilutions. A 250-ppm lanthanum (Fisher) solution was prepared, and this was added in volumes to the standard and sample flasks so that the final concentration was 10 times that of calcium concentration in each flask. Samples were prepared by obtaining and weighing approximately one-third of a powdered multivitamin which was dissolved in approximately 20 ml of 2 M HNO3 in a 125- ml Erlenmeyer flask. The exact amounts of each vitamin used in the experiment can be found in Table 1. To help dissolve the vitamin powder the flask was heated for 7 minutes at a gentle boil in the hood. The sample was vacuum filtered and the sample was also diluted 10:1 in 0.1 HNO3 to help prevent the clogging of the nebulizer. This process was done for two different multivitamins: Centrum Ultra Men s and One Source Teen s. Table 1. Masses of the multivitamin tablets used for analysis. Vitamin Total Weight (grams) Weight Used (grams) Percent of Vitamin Centrum (1) 1.4569 0.4868 33.41% One Source (1) 1.3037 0.4348 33.35% Centrum (2) 1.4569 0.4833 33.17% One Source (2) 1.3037 0.4317 33.11% Centrum (3) 1.4569 0.4329 29.71% One Source (3) 1.3037 0.4118 31.59% To prepare the samples for standard additions the working linear range for each element needed to be determined for the AA instrument. The determined working linear ranges along with the amounts of each mineral in the vitamin can be found in Table 2. Table 2. Working linear ranges and amounts of the elements Element Element Atomic Wt. (g/mol) Initial Solvent Working range (ppm) Wavelength (nm) Amount in Multivitamin (CUMens) mg Amount in multivitamin (OST) mg Ca 40.078 HNO 3 0-5 422.67 210 225 Mg 24.305 HNO 3 0-1 285.2 100 40 From that information, a stock solution of the multivitamin was prepared in 0.1 M HNO3 so that the concentration of the element of interest was twice the maximum working linear range. A stock solution of the element that was being analyzed was prepared in 0.1 M HNO3 so that it was at five times the maximum working range. This was done separately for each individual element following the guidelines according to Table 3. The AA spectrometer was set up individually for each element, and the instrument was blanked prior to every trial. The instrument was set up according to the standard additions guidelines provided by the SPECTRAA software. Again this was done separately for each element under analysis. 2

Table 3. Example of the standard addition samples Centrum Ultra Men s Flask A Flask B Flask C Flask D Flask E Mg (5ppm) ml 0 1.0 2.0 3.0 4.0 Multivitamin (2ppm) ml 5.0 5.0 5.0 5.0 5.0 Approx. Total [Mg] in ppm 0.4 0.6 0.8 1 1.2 Results and discussion The standard additions and prepared samples were analyzed via the atomic absorption spectrometer. Table 4 displays the results found from each trial. Back calculations were done to achieve this original concentration of the multivitamin prior to any dilutions. These calculations were completed using the simple formula M1V1=M2V2. Figure 1 demonstrates one of the standard additions curves obtained from each run. The majority of these curves had an R 2 value of 0.995 or higher. Table 4. Experimentally determined concentrations and expected concentrations Experimental OST Mg (ppm) OST Ca (ppm) Cent Mg (ppm) Cent Ca (ppm) 1 148 844 403 830 2 143 843 390 827 3 193 952 340 1035 Data Excluded ------- 952 ------- 1035 Expected 1 133 745 334 624 2 126 711 332 697 3 133 750 334 702 Table 5 shows the averages, standard deviations and % relative standard deviations of the results shown in Table 4 and also these values without the outliers that were calculated with the Grubb s test for an outlier. Table 5. Averages, standard deviations and % RSD for final data. OST Mg OST Ca Centrum Mg Centrum Ca 148 844 403 830 143 843 390 827 193 952 340 1035 Average 161.3 879.7 377.7 897.3 Standard Dev. 27.53 62.64 33.26 119.2 %RSD 17.07 7.121 8.807 13.29 w/o outliers Average ------ 843.5 ----- 828.5 Standard Dev. ------ 0.7071 ----- 2.121 %RSD ------ 0.0838 ----- 0.2560 3

0.6 0.5 y = 0.0774x + 0.1904 R² = 0.9974 Absorbance 0.4 0.3 0.2 0-3 -2-1 0 1 2 3 4 5 Figure 1. Example of standard additions curve The outcome of this experiment showed that the concentrations of calcium and magnesium were slightly higher than that which was stated on the label of the multivitamins. Table 5 gives the variance between what was found and what was expected, in mg per tablet. Data presented is the average of our runs minus the outliers. Table 6. Variation OST Mg (mg) OST Ca (mg) Centrum Mg (mg) Centrum Ca (mg) Experimental 44.56 258.1 119 258.1 Expected 40.0 225 100 210 % Difference 11.4 14.7 19.0 22.9 Conclusions Calcium and magnesium in two multivitamins were determined using atomic absorption spectroscopy and standard additions. Amounts of each element were found to be higher than what was stated on the label. The complexity of the matrix throughout this experiment was extremely frustrating to work with and lanthanum additions did help to reduce these effects significantly when added correctly. Taking this into consideration, the milligrams of element found in the multivitamin versus the amount stated on the label are similar to those of Arnold and Arndt. Acknowledgments 0.1 Concentration of Standard addition (ppm) We would like to acknowledge Dr. Jensen for allowing us to perform this experiment and for helping us when we needed some assistance, the Concordia Chemistry Department for preparing us for this, Marcie for encouragement and sugary treats, Stu, Alex and Nathan for TA ing. 4

References 1) Arnold, R. J., B Arndt, et al. 2011. Overcoming Matrix Effects in a Complex Sample: Analysis of Multiple Elements in Multivitamins by Atomic Absorption Spectroscopy. Journal of Chemical Education, Bloomington, IN. pp. 484-487 2) Harris, Daniel C., Quantitative Chemical Analysis, 8 th ed.; W. H. Freeman and Company: New York, 2010. 3) Rolfes, S. R., Whitney, E. Understanding Nutrition, 12 th ed.; Wadsworth Cengage: Belmont, CA., 2011. 5