Neuropack X1. EP/EMG/NCV Measuring System MEB-2300 Desktop System

Similar documents
Type-D EEG System for Regular EEG Clinic

KEYPOINT XP EDITION. Invented for Value and Performance. A Good Diagnosis is Half the Cure

Version 10. Getting Started Guide

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

Dash 18X / Dash 18 Data Acquisition Recorder

ADINSTRUMENTS. making science easier. LabChart 7. Student Quick Reference Guide

PRODUCT SHEET OUT1 SPECIFICATIONS

Dash 8Xe / Dash 8X Data Acquisition Recorder

Advancing medical technology to help you, help others.

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

U1602A Handheld Oscilloscopes, 20 MHz

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

PHONE MANAGER INDEX. page

MS WORD 2007 (PC) Macros and Track Changes Please note the latest Macintosh version of MS Word does not have Macros.

Lab 1: The Digital Oscilloscope

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

RLC Series Resonance

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Plena Voice Alarm System. Software Manual Configuration Software

Point of view HDMI Smart TV dongle Mini RF Keyboard

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

Laboratory Guide. Anatomy and Physiology

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

NEW PRODUCT ANNOUCEMENT

Everything you need for protection scheme testing

Agilent Technologies 3000 Series Oscilloscopes

Data Analysis Methods: Net Station 4.1 By Peter Molfese

MODEL INDEX ADS1152CA ADS1102CA ADS1062CA ADS1022C

Manual for the sound card oscilloscope V1.24 C. Zeitnitz english translation by P. van Gemmeren and K. Grady

The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform

Universal Simple Control, USC-1

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

Lab Exercise 1: Acoustic Waves

MANUAL PC1000R

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

Audacity Sound Editing Software

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

LEVERAGING FPGA AND CPLD DIGITAL LOGIC TO IMPLEMENT ANALOG TO DIGITAL CONVERTERS

1. SAFETY INFORMATION

Case study: how to use cutoff conditions in a FRA frequency scan?

ENGLISH...3 DEUTSCH...13 FRANÇAIS...23 ESPAÑOL...33 ITALIANO...43 PORTUGUÊS...53

Numerical Parameters Analysis of Boonton 4540 Peak Power Meter

The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform.

SVPRIBOR ALFA DSL. Users Manual

User's Guide. Integrating Sound Level Datalogger. Model Introduction

ios 9 Accessibility Switch Control - The Missing User Guide Updated 09/15/15

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

MIDI control allows the Split Personality to be used remotely in rack systems, or integrated into MIDI controlled setups for easy preset recall.

RF Measurements Using a Modular Digitizer

Summary Table Voluntary Product Accessibility Template

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER. Setting The Clinical Standard

Datex-Ohmeda Critical Care Monitor

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

How To Sell A Talan

Power Point 2003 Table of Contents

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Notice. Reverse engineering and disassembly are prohibited.

EMG Biofeedback Device

Plena Two-zone Call Station. Installation and User Instructions PLE-2CS

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

JCUT CNC Router 3030A/6090/8090/1212/60150/1218/1224/1325/1530/A/B

MANUAL (p. 2) USB Turntable HAV-TT20USB

Greenline Industrial Monitors IMD-C Series. User Manual

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

Figure 1: Multiple unsynchronized snapshots of the same sinusoidal signal.

TL074 TL074A - TL074B

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

DataSheet. SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806. Application Domain

64-CHANNEL INTEGRATED AMPLIFIER

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

13-1. This chapter explains how to use different objects.

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

SC Analysis Software. The software provides 5 main functions:

DCM555 - Data Communications Lab 8 Time Division Multiplexing (TDM) Part 1 - T1/DS1 Signals

The Sonometer The Resonant String and Timbre Change after plucking

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Analogue/Digital Analogue and Differential Oscilloscopes

APPLICATION NOTE AP050830

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: Fax:

Windows XP Pro: Basics 1

AN-007 APPLICATION NOTE MEASURING MAXIMUM SUBWOOFER OUTPUT ACCORDING ANSI/CEA-2010 STANDARD INTRODUCTION CEA-2010 (ANSI) TEST PROCEDURE

Hear The Future...Now! SIEM-2T/SIEM-2R

Lab 3: Introduction to Data Acquisition Cards

Logging of RF Power Measurements

DATA SHEET. TDA1518BQ 24 W BTL or 2 x 12 watt stereo car radio power amplifier INTEGRATED CIRCUITS

NIS-Elements Viewer. User's Guide

Dash 10 Recorder. QUICK START GUIDE Supports Recorder System Software Version INTRODUCTION 2. GETTING STARTED 3. SETTING UP CHARTS AND GRIDS

DiGiCo SD Series V726+ Appendix

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

Summary Table Voluntary Product Accessibility Template

Transcription:

Neuropack X1 EP/EMG/NCV Measuring System MEB-2300 Desktop System

For more than 60 years, healthcare providers worldwide have relied on the quality and reliability of the Nihon Kohden line of comprehensive and innovative neurodiagnostic and -monitoring instrumentation to aid in the diagnosis, information and treatment of their patients. Optional Software Packages: QP-219: Review Station Software QP-258: Trending Software QP-259: Autonomic Nervous System Testing (Microneurogram, R-R Interval, Sympathetic Skin Response) QP-260: Event Related Potential (P300, MRCP, CNV) The MEB-2300 is the latest and most advanced EP/EMG system in the Nihon Kohden product portfolio. Available with either a six or twelve channel amplifier and up to two electrical stimulators, the MEB is designed with numerous time-saving features to maximize the user s workflow without compromising the integrity of data acquisition. Basic exam software including EMG, NCS, SEP, ABR and VEP protocols come standard with the MEB-2300. The new examination list creates a seamless integration of protocols, patients and reports, increasing productivity and reducing test time. Mobile Control Panel Operation Panel PV-230 The mobile function keypad enables the user to complete an entire exam without the use of a keyboard or mouse. This simple control panel contains the main operation buttons seen in previous models, monitorstimulate-analysis-stop and store, with added key features such as function keys, a number pad and NeuroWorkbench controls. Low Noise Amplifier Six Channel JB-206 The MEB-2300 uses a low noise amplifier with active electrodes to provide clean waveforms easily and quickly. An integrated impedance check can be activated with the touch of a button from the amplifier to ensure properly placed and seated electrodes.

NeuroNavi Flexible Software Innovation NeuroReport A customized report can be generated with the click of a button using our proprietary NeuroReport software. Included in NeuroReport are several selectable layouts which can display your facility s logo, test results with highlighted abnormals, waveforms and a powerful auto-text summary. Saved within the database, the report can automatically be signed electronically and converted to a PDF, protecting the electronic record while keeping it universally viewable. NeuroNavi shows examination information and electrode and stimulation positions for NCS and other exams. This guide can be referenced on the screen at any time. NeuroWorkbench Scheduler NeuroWorkbench Patient List NeuroWorkbench Protocol Tab Workflow Solutions NeuroWorkbench is the core integrator of the Nihon Kohden neurology product portfolio. This common interface allows for examination scheduling, protocol administration and data management that improve workflow. NeuroWorkbench provides HIPAA Compliant access to clinical data and records with passwords and three levels of administrative rights, as well as audit trails. A flexible NeuroWorkbench option includes an HL7 interface. The NeuroWorkbench SQL Database integrates all of the Nihon Kohden neurology devices to provide a complete database across all neuro- diagnostic and -monitoring modalities. Menu Window for an MEB Examination Open an MEB examination screen using the examination protocol menu. Menu Tabs Up to eight category tabs with 10 programs per tab for a total of 80 preset examination programs. Data Manager Tab Database files Copy, move and delete file Patient database with search and query function Workbench Tab Scheduler Remote access Review patient files

Standard Examination Programs Routine EMG Program Quick Display Trigger EMG Muscle Summary The routine EMG program utilizes auto You can easily switch between four A cascading waveform window displays Measurement results and saved waveforms can MUP detection and classification, and real measurement modes that you can define the waveforms which are triggered be displayed in the muscle summary window. time turns/amp analysis. A functional and sophisticated findings screen meets various needs in clinical use by easy and smooth operation. Interference Turns/amp measurement is automatically freely for example for insertion activity, motor unit detection or turn/amplitude analysis or interference by pressing a button at the bottom of the screen or on the control panel. MUP Analysis by either level trigger, window trigger or rise time trigger in chronological order. You can change the beginning and end point of the duration. Up to eight new sequential MUP waveforms are displayed on the MUP sweep window without scrolling. The summary window is the best place to start typing the EMG findings next to the results of the examination. The latest EMG findings screen shows up to 26 traces of waveforms with annotations in the Monitor Waves window and up to 20 MUP waveforms in the MUP window on one screen for efficient and quick performed. The measurement result MUP waveforms are automatically detected EMG findings. is displayed at every one second on and classified into groups of similar the turns-interval histogram, turns/amp shaped MUPs. MUP measurement result histogram and turns/amp graph. The turns/amp normative data of several muscles are installed as default settings and its normative area is displayed in the turns/amp histogram. You can easily recognize whether or not the measuring waveforms are in the normative range. (duration, amplitude, phase, turns and firing rate) are shown next to the waveforms or in a dedicated summary screen. The averaged MUP of the same MUP groups are calculated and displayed with the numeric data. EMG Playback/EMG Player You can also easily review any acquired waveform with sound after measurement by clicking the EMG player button. This tool lets you play back EMG files with sound on a review station for presentations and lectures. Display up to 600 sec of EMG with sound Sweep speed, sensitivity, and filter settings can be changed afterwards; a great function for teaching purposes Compressed/cascaded waveform display

Single Fiber Jitter Analysis Quantitative EMG Perform jitter reanalysis at different trigger levels for all acquired waveforms. MCD, MSD, MIPI, firing rate and blocking can be automatically analyzed. Two single fiber modes are available: voluntary contraction and stimulated. Eight Channels of Macro EMG Simultaneous eight channel macro EMG recording is possible. Acquired waveforms can be reanalyzed. Triggered waveforms and averaging result can be simultaneously displayed. Real time MUP analysis With the template matching method, MUP are automatically classified into several patterns and the amplitude, phase, turns, area, rise time and firing rate are quantitatively analyzed in real time. There are two methods of analysis: triggered and continuous. The analysis results can be statistically processed. Real time interference pattern analysis Interference patterns can be analyzed in two ways: turns/amp analysis and power spectrum analysis with FFT.

Nerve Conduction Study F-Wave With the dual sensitivity function, both M- and F-wave are displayed with a proper amplification. F-Wave latency is displayed in the F-Wave histogram window. The NCS program lets you perform MCS, SCS and F-Wave in one program. Any number and combination of examinations can be created in your own custom routine protocol by selecting nerve, side and exam. You can change the examination by just clicking the item in the list box, or by clicking a button on the dedicated operation panel of the Neuropack. H-Reflex The intensity-amplitude graph and superimposed waveforms are displayed on the same window. Motor NCS/Sensory When measuring with the MEB there is no need to manually pick the stimulation site before starting the recording. The software does this automatically for you and, if necessary, it can be easily changed. Side comparisons and combined motor and sensory tests can be shown in one waveform screen and also have their own dedicated evaluation tables. Normative data are shown on the same screen. The superimposed waveform in real time is shown at the same time, so you can easily compare the amplitudes of all stimulation sites and thus judge the quality of your stimulation. Repetitive Stim The amplitude of each sequence is displayed as a bar graph on the same screen. You can see the summary of the repetitive stimulation study at a glance. The waveform of each sequence can be displayed by clicking the corresponding bar graph. Up to 12 sequences of stimulation patterns can be set for one automatic measurement (automatic sequence function). Stimulation can be done with either high or low frequency or combined in the same protocol. Blink-Reflex The relation between the mark position and the normative range is easy to see on the blink measurement table window.

Evoked Potentials Standard SEP examination protocols are: Simultaneous SSEP and SEP measurement Standard VEP examination protocols are: Standard AEP examination protocols are: SEP (somatosensory evoked potential) Upper and lower extremity measurements Pattern-VEP ABR (auditory brainstem response) SSEP (short-latency SEP) can be conducted at the same time on Goggle-VEP MLR (middle latency response) ECG-SSEP (ECG-triggered SSEP) the same screen. Flash-VEP SVR (slow vertex response) ESCP (evoked spinal cord potential) ECG artifact-free SSEP With ECG-SSEP protocol, stimulation and Side comparison Split screen display allows for side comparisons at a glance. ERG (electroretinogram) EOG (electrooculogram) Flexible pattern stimulations EcochG (electrocochleogram) Three types of auditory stimulation Click, tone burst, and tone pip stimulation averaging is done during the flat period VEP protocol requires a VEP monitor. are available. of the ECG waveform so artifact-free waveforms can be recorded. Pattern reversal stimulation can be selected from full, half, and quarter ABR auto marking Signal triggering and back averaging Cortical potentials prior to muscle contraction can be recorded by using a rectified EMG signal trigger and back averaging. visual field. 4 to 128 horizontal divisions can be selected for patterns. Variety of visual stimulations A monitor for pattern reversal, LED goggles and flash stimulator options allow complete visual testing. In the ABR protocol, automatic waveform marking allows time-saving measurement of latency, amplitude, and interval. Automatic separation of AP and CM waveforms In EcochG examination, AP and CM can EOG velocity waveform display be automatically separated from the original waveforms in real time. The original, AP and CM waveforms are simultaneously With the integrated differential displayed on the screen. amplifier, the velocity waveform can be simultaneously displayed with the Simultaneous ABR and MLR original EOG signal. ABR and MLR can be measured simultaneously on the same screen.

Specifications Amplifier Number of channels: JB-206B: 6, JB-212: 12 Input impedance: 200 MΩ ±20% (differential mode), 200 MΩ ±20% (when the active electrode cable is used, differential mode), 1000 MΩ (common mode) Noise: < 0.6 μvrms at 1 Hz to 10 khz, < 1.1 μvrms at 1 Hz to 10 khz (when the active electrode cable is used) Common mode rejection ratio: 106 db (balanced mode), 90 db (balanced mode, when the active electrode cable is used), 112 db (Isolation mode) Sensitivity: 1, 2, 5, 10, 20, 50, 100, 200, 500 μv/div, 1, 2, 5, 10 mv/div ±5% Low-cut filter: 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 30, 50, 100, 200, 500 Hz, 1, 2, 3 khz (±20%) High-cut filter Channel 1 and 2: 10, 20, 50, 100, 200, 500 Hz, 1, 1.5, 2, 3, 5, 10, 20 khz (±20%) Channel 3 to 5: Upper limit 10 khz at 12 db/oct (±20%) Channel 6 to 10: Upper limit 5 khz at 12 db/oct (±20%) Channel 11 and 12: Upper limit 3 khz at 12 db/oct (±20%) AC interference notch filter: 50 or 60 Hz (rejection ratio: < 1/20) Reset: Available Rectification: Off, half, full Electrode impedance check: 2, 5, 10, 20, 50 kω indication Amplitude calibration: 1, 10, 100 μv, 1, 10 mv (within ±5%) Acquisition A/D converter: 18 bits Time base modes: Individually selected for each channel (up to 12 channels) Monitor time base: 5, 10, 20, 30, 50 ms/ div, 0.1, 0.2, 0.5, 1 s/ div (within ±5%) Data points: 2048/20 div Conversion speed: 5 μs/1 ch, 10 μs/2 ch, 20 μs/3 and 4 ch, 50 μs/5 to 10 ch, 100 μs/11 and 12 ch Analysis time base: 0.1, 0.2, 0.5, 1, 2, 3, 5, 10, 20, 30, 50 ms/ div, 0.1, 0.2, 0.5, 1 s/div (within ±5%) or 0.1 to 0.9 ms in 0.1 ms steps (within ±5%) 1 to 99 ms in 1.0 ms steps (within ±5%) 100 to 1000 ms in 0.01 s steps (within ±5%) Delay time: 10 to 10 div in 1 div steps or 0 to 500 ms in 0.1 ms steps Number of averages: 1 to 9999 Artifact reject inhibit range: ±1 to ±5 div in 0.1 div steps, Off Waveform storage capacity: Depends on the hard disk free space of the PC unit Display Number of examination windows: Up to 12 Waveform display mode: Monitor (free run), sweep (trigger), average Cursor: Two vertical or horizontal lines for time or amplitude measurements, one vertical line for mark set Scale: 5, 10, 15, 20 div Grid: Line, dot, off stimulator common functions Triggers Number of channels: 6 Trigger mode: Recurrent, random, foot switch, single stimulation, signal 1 to 5, somato 1, somato 3, external 1 to 6 Trigger wave mode: Single, double, train Stimulation rate With the list box: 0.1 to 0.9 Hz in 0.1 Hz steps, 1 to 10 in 1 Hz step, 13, 15, 17 Hz, 20 to 100 Hz in 10 Hz steps (within ±5% of the preset value 0.95) With the keyboard: 0.1 to 100 Hz in 0.1 Hz steps (within ±5%) Delay time With the list box: 0 to 9 ms in 1 ms steps, 10 to 90 ms in 10 ms steps, 100 to 900 ms in 100 ms steps, 1 to 10 s With the keyboard: 0 to 10 s in 0.01 ms steps Electric stimulators Number of channels: 2 (monophasic/ biphasic stimulation, high current stimulation) Output mode: Constant current Output current: Monophasic/biphasic stimulation, 0 to 100 ma (load resistance: 1 kω, step can be selected from 0.05, 0.1, 0.2, 0.5, 1 ma) High current stimulation: 0 to 200 ma (load resistance:1 kω, step can be selected from 0.05, 0.1, 0.2, 0.5, 1 ma) Stimulation pulse duration: 0.05-1.0ms +/- 10% 0.05ms when stimulus is greater than 2mA.+/- 20% 0.03ms when stimulus is less than 2mA Number of outputs on the stimulation pod: 5 available Biphasic stimulation mode: Positive, negative, bipolar, alternate Temperature measurement: 0 to 45 C (32 to 113 F) ±0.1 C (0.18 F) Auditory Stimulators Examination side: Left, both, right Stimulation waveform: Click, tone burst Stimulation phase (polarity): Condensation (positive), rarefaction (negative), alternating stimulation Intensity: 0 to 135 db SPL (within ±2 db) contralateral white noise masking: 10, 20, 30, 40, 50 db or off (within ±5 db) Click pulse duration: 0.1, 0.2, 0.3, 0.5, 1 ms (within ±5%) Tone burst frequency With a list box:125, 250, 500, 1 k, 1.5 k, 2 k, 3 k, 4 k, 6 k, 8 khz (within ±5%) With a keyboard: 50 Hz to 10 khz (within ±5% plateau time of tone burst) With a list box: 0, 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000 ms (within ±5%) With a keyboard: 0 to 1,000 ms in 1 ms steps (within ±5%) Rise/fall time of tone burst With a list box: 0.1, 0.2, 0.3, 0.5, 1, 2, 3, 10 ms (within ±5%) With a keyboard: 0.1 to 3000 ms in 0.1 ms steps (within ±5%) Visual Stimulators Stimulation modes: Pattern reversal, LED goggles, external visual stimulation Pattern reversal Field format: Full, left, right, upper, lower, upper left, lower left, upper right and lower right field Patterns: Checkerboard, horizontal bars, vertical bars Number of horizontal divisions: 4, 8, 16, 32, 64, 128 Brightness: More than 80 cd/m2 LED Goggles Side: Left, right, both Printer Printing mode: Hard copy, review External Units External input: 8 ch, 0.2, 1 V/div External output: 8 ch 1 V/div (5 khz at 1 ch, 200 Hz at 8 ch) Line I/O: Available Trigger input: 6 ch Amplitude: more than 4 V (positive), less than 0.5 V (negative) Available for pulse whose duration is more than 10 μs, either positive and negative can be selectable Trigger output: 6 ch Amplitude: 5 V (positive), less than 0.5 V (negative) Pulse duration: 1, 5, 10 ms Either positive and negative can be selectable Response switch: When closed, operates at low level Digital input: When closed, operates at low level 6 ch Amplitude: less than 0.5 V (negative) Available for pulse whose duration is more than 1 ms Dimensions and Weight Main Unit: 390(W) x 55(H) x 304(D) mm, 3.2 kg Electrode Junction Box: 180(W) x 56.5(H) x 234.5(D) mm, 1.5 kg Constant current stimulator unit: 56.5(W) x 190(H) x 240(D) mm, 1.0 kg Somato control box: 37(W) x 62(H) x 21(D) mm, 0.16 kg Control panel unit: 253(W) x 100(H) x 300(D) mm, 1.0 kg Multi interface box: 160(W) x 24(H) x 120(D) mm, 0.8 kg Power Requirements Line voltage and frequency MEB-2300A (DC-230BA): 100-120 V ±10% 60Hz±1% Power input DC-230BA main unit: 75 VA Operating Environment Temperature: 10 to 35 C (50 to 95 F) Humidity: 30 to 80% (non condensing) Atmospheric pressure: 700 to 1060 hpa Storage and Transport Temperature: -20 to 65 C (-4 to 149 F) Humidity: 10 to 95% (non condensing) Atmospheric pressure: 700 to 1060 hpa

When performance counts, you can rely on Nihon Kohden to assist you in delivering the highest quality patient care as efficiently as possible. Nihon Kohden is committed to bringing trusted and innovative solutions to the changing demands of the neurodiagnostics field today and into the future. us.nihonkohden.com NMLB 027 [C]-CO-0162 NeuroWorkbench is a registered trademark and NeuroReport and NeuroNavi are trademarks of Nihon Kohden Corporation.