Neuropack S1. MEB-9400 EMG/NCV/EP Measuring System

Similar documents
Type-D EEG System for Regular EEG Clinic

The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform

KEYPOINT XP EDITION. Invented for Value and Performance. A Good Diagnosis is Half the Cure

The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform.

Advancing medical technology to help you, help others.

Advancing medical technology to help you, help others.

Version 10. Getting Started Guide

Dash 18X / Dash 18 Data Acquisition Recorder

Dash 8Xe / Dash 8X Data Acquisition Recorder

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

PRODUCT SHEET OUT1 SPECIFICATIONS

Everything you need for protection scheme testing

Kramer Electronics, Ltd. Site-CTRL and Web Access Online User Guide (Documentation Revision 2)

Neurodiagnostic Equipment Solutions

Current Monitoring Kit QUICK START GUIDE

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

USB Recorder User Guide

MANUAL (p. 2) USB Turntable HAV-TT20USB

Plena Voice Alarm System. Software Manual Configuration Software

MANUAL PC1000R

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

MS WORD 2007 (PC) Macros and Track Changes Please note the latest Macintosh version of MS Word does not have Macros.

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

USB Recorder. User s Guide. Sold by: Toll Free: (877)

Current Monitoring Kit

Point of view HDMI Smart TV dongle Mini RF Keyboard

Plena Two-zone Call Station. Installation and User Instructions PLE-2CS

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

USB VoIP Phone Adapter. User s Manual

Product Specifications

Data Analysis Methods: Net Station 4.1 By Peter Molfese

BrainMaster tm System Type 2E Module & BMT Software for Windows tm. Helpful Hints

Case study: how to use cutoff conditions in a FRA frequency scan?

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

QUALITY AV PRODUCTS INMATE/INMATE USB PROFESSIONAL 19" MIXER. User Guide and Reference Manual

CLINICAL NEUROPHYSIOLOGY

Chiropractic Physician and Clinical Director, Advanced Physical Medicine of Yorkville, Ltd., Yorkville, IL, 2003-present

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

PT Mbps Powerline Adapter. User Guide

Call Recorder Oygo Manual. Version

TS-770 SERIES CONFERENCE SYSTEM

Call Recorder Apresa User Manual

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

MVS - Mini Video Speaker

EMG Biofeedback Device

USB 3.0 Universal Mini Docking Station Adapter

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Temperature & Humidity SMS Alert Controller

1. SAFETY INFORMATION

VM-4 USB Desktop Audio Device Installation Guide

Multi-Range Programmable DC Power Supplies 9115 Series

Micro HDMI to VGA with Audio Adapter. Quick Installation Guide. Introduction. Key Features and Benefits. System Requirements.

PHONE MANAGER INDEX. page

Tektronix RSA306 USB Spectrum Analyzer

ALON MP3 Dictaphone. User's manual. 1. Introduction 2. Audio Player 3. Voice Dictaphone 4. Phone calls recorder 5. Customer support.

interviewscribe User s Guide

VM-8 USB Desktop Audio Device Installation Guide

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

A complete, 24-hour HD video EEG solution

Notice. Reverse engineering and disassembly are prohibited.

If you need additional assistance please contact our Technical Support Center at 24 hours a day, 7 days a week.

TESTBOX SHAKE TABLE USER MANUAL

Waveform Monitor Audio & Loudness Logging

Laboratory Guide. Anatomy and Physiology

SC Analysis Software. The software provides 5 main functions:

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Lab 3: Introduction to Data Acquisition Cards

Universal Simple Control, USC-1

How to create and personalize a PDF portfolio

Manual Analysis Software AFD 1201

Impedance 50 (75 connectors via adapters)

Soft Call Recorder v3 Manual Version

Power Log PC Application Software

User Manual USB Laptop KVM Switch. GCS661U Part No. M1069

ACS CLIENT SOFTWARE USER MANUAL

RLC Series Resonance

CPEi 800/825 Series. User Manual. * Please see the Introduction Section

DIGICLIENT 8.0 Remote Agent Software

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Advancing medical technology to help you, help others.

A Division of Cisco Systems, Inc. GHz g. Wireless-G. PCI Adapter with RangeBooster. User Guide WIRELESS WMP54GR. Model No.

Printed in China. Issue 4 AT&T 12/11. Message Guard is a registered trademark of Advanced American Telephones.

Turbo 85 Mbps Powerline Ethernet Adapter Model # APL8512. User s Manual. Ver. 1A

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

Multi-Range Programmable DC Power Supplies 9115 Series

Brio-Rmanual:Cursamanual.qxd 08/04/ :25 Page1

Product Information Sheet UH36 Hi Pot Tester

ADINSTRUMENTS. making science easier. LabChart 7. Student Quick Reference Guide

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers

Greenline Industrial Monitors IMD-C Series. User Manual

Chord Limited. Mojo Dac Headphone Amplifier OPERATING INSTRUCTIONS

BlackHawk for MAC Software User Guide

Wireless-N. User Guide. PCI Adapter WMP300N (EU) WIRELESS. Model No.

The RIDZ 8x2 Audio Switcher

Best Practices for Handset Testing with Spirent Communications Nomad

EMCS. Netport 4. A Brief How-To Guide

Datex-Ohmeda Critical Care Monitor

UVO SYSTEM QUICK REFERENCE GUIDE

Transcription:

Neuropack S1 MEB-9400 EMG/NCV/EP Measuring System

The feature rich Nihon Kohden Neuropack MEB-9400 offers efficient EMG, NCV and EP exams with innovative time saving technology. Available in a 2 or 4 channel amplifier, the Neuropack is offered in a desktop or laptop configuration for portability without compromise. Our compact, low noise amplifier insures clean waveforms easily and quickly. Basic exam software including EMG, NCS, SEP, ABR and VEP is standard with the MEB-9400. Tailor the Quick menu to your examination workflow to reduce testing time. Quick EMG and NCS programs provide the fastest examination possible. The MEB-9400 value is further enhanced with our gold standard 32 channel EEG option for the most flexible multi-modality configuration on the market today. Low Noise, Compact Amplifier The low noise amplifier speeds up the examination by giving you clean waveforms easily and quickly. Choose from our 2 or 4 channel amplifier (JB-942 or JB-944). Impedance Check Needle Electrode Holder Quick Examination Innovative hardware and software shorten the examination time. User-Friendly Control Panel The easy-to-use control panel allows for smooth and efficient examinations. You can change the electric stimulation duration and rate with a simple one-touch operation. The side/set key and muscle/test keys allow quicker EMG and NCS examinations. Select the measurement side in EMG and NCS program Reset Key Set the stimulation intensity to zero Cable Hook Select the electric stimulation duration and rate

NeuroNavi Flexible Software Innovation NeuroReport A customized report can be generated with the click of a button using our proprietary NeuroReport software. Included in NeuroReport are several selectable layouts which can display your facility s logo, test results with highlighted abnormals, waveforms and a powerful auto-text summary. Saved within the database, the report can automatically be signed electronically and converted to a PDF, protecting the electronic record while keeping it universally viewable. NeuroNavi shows examination information and electrode and stimulation positions for NCS and other exams. This guide can be referenced on the screen at any time. NeuroWorkbench Scheduler NeuroWorkbench Patient List NeuroWorkbench Protocol Tab Workflow Solutions NeuroWorkbench is the core integrator of the Nihon Kohden neurology product portfolio. This common interface allows for examination scheduling, protocol administration and data management that improve workflow. NeuroWorkbench provides HIPAA Compliant access to clinical data and records with passwords and three levels of administrative rights, as well as audit trails. A flexible NeuroWorkbench option includes an HL7 interface. The NeuroWorkbench SQL Database integrates all of the Nihon Kohden neurology devices to provide a complete database across all neurodiagnostic and -monitoring modalities. Menu Window for an MEB Examination Open an MEB examination screen using the examination protocol menu. Menu Tabs Up to eight category tabs with 10 programs per tab for a total of 80 preset examination programs. Data Manager Tab Database files Copy, move and delete file Patient database with search and query function Workbench Tab Scheduler Remote access Review patient files

Nerve Conduction Study Electromyography (EMG) Hardware Options KD-019 or NIH-9000 Cart KH-001 Arm DR-531-14 Headphones LS-102 LED Goggles The NCS program lets you perform MCS, SCS and F-Wave in one program. Any number and combination of examinations can be created in your own custom routine protocol by selecting nerve, side and exam. You can change the examination by just clicking the item in the list box, or by clicking a button on the dedicated operation panel of the Neuropack. Motor NCS/Sensory When measuring with the MEB there is no need to manually pick the stimulation site before starting the recording. The software does this automatically for you and, if necessary, it can be easily changed. Side comparisons and combined motor and sensory tests can be shown in one waveform screen and also have their own dedicated evaluation tables. Repetitive Stim The amplitude of each sequence is displayed as a bar graph on the same screen. You can see the summary of the repetitive stimulation study at a glance. The waveform of each sequence can be displayed by clicking the corresponding bar graph. Up to 12 sequences of stimulation patterns can be set for one automatic measurement (automatic sequence function). Routine EMG Program The routine EMG program utilizes auto MUP detection and classification, and real time turns/amp analysis. A functional and sophisticated findings screen meets various needs in clinical use by easy and smooth operation. Interference Turns/amp measurement is automatically performed. The measurement result is displayed at every one second on the turns-interval histogram, turns/amp histogram and turns/amp graph. The turns/amp normative data of several muscles are installed as default settings and its normative area is displayed in the turns/amp histogram. You can easily recognize whether or not the measuring waveforms are in the normative range. Quick Display You can easily switch between four measurement modes that you can define freely for example for insertion activity, motor unit detection or turn/amplitude analysis or interference by pressing a button at the bottom of the screen or on the control panel. MUP Analysis MUP waveforms are automatically detected and classified into groups of similar shaped MUPs. MUP measurement result (duration, amplitude, phase, turns and firing rate) are shown next to the waveforms or in a dedicated summary screen. The averaged MUP of the same MUP groups are calculated and displayed with the numeric data. EMG Playback/EMG Player You can also easily review any acquired waveform with sound after measurement by clicking the EMG player button. This tool lets you play back EMG files with sound on a review station for presentations and lectures. Display up to 600 sec of EMG with sound Sweep speed, sensitivity, and filter settings can be changed afterwards; a great function for teaching purposes Compressed/cascaded waveform display JE-921 EEG Amplifier LS-120 Photic Stimulator Software Options QP-951 Quantitative EMG Software QP-952 Single Fiber and Macro EMG Software QP-954 Autonomic Nervous System Testing Software QP-930 EMG Playback QP-219 EMG Review Software NK-NWB NeuroWorkbench Server Software Normative data are shown on the same screen. The superimposed waveform in real time is shown at the same time, so you Stimulation can be done with either high or low frequency or combined in the same protocol. NK-NWB HL7 Interface Software NK-EEGAddOn can easily compare the amplitudes of all stimulation sites and thus judge the quality of your stimulation.

Nerve Conduction Study Evoked Potentials The NCS program lets you perform MCS, SCS and F-Wave in one program. Any number and combination of examinations can be created in your own custom routine protocol by selecting nerve, side and exam. You can change the examination by just clicking the item in the list box, or by clicking a button on the dedicated operation panel of the Neuropack. Standard SEP examination protocols are: SEP (somatosensory evoked potential) SSEP (short-latency SEP) ECG-SSEP (ECG-triggered SSEP) ESCP (evoked spinal cord potential) Standard AEP examination protocols are: ABR (auditory brainstem response) MLR (middle latency response) SVR (slow vertex response) EcochG (electrocochleogram) Motor NCS/Sensory When measuring with the MEB there is no need to manually pick the stimulation site before starting the recording. The software does this automatically for you and, if necessary, it can be easily changed. Side comparisons and combined motor and sensory tests can be shown in one waveform screen and also have their own dedicated evaluation tables. Normative data are shown on the same screen. Repetitive Stim The amplitude of each sequence is displayed as a bar graph on the same screen. You can see the summary of the repetitive stimulation study at a glance. The waveform of each sequence can be displayed by clicking the corresponding bar graph. Up to 12 sequences of stimulation patterns can be set for one automatic measurement (automatic sequence function). Stimulation can be done with either high or low frequency or combined Standard VEP examination protocols are: Pattern-VEP Goggle-VEP Flash-VEP ERG (electroretinogram) EOG (electrooculogram) Flexible pattern stimulations VEP protocol requires a VEP monitor. Pattern reversal stimulation can be selected from full, half, and quarter visual field. 4 to 128 horizontal divisions can be selected for patterns. Three types of auditory stimulation Click, tone burst, and tone pip stimulation are available. ABR auto marking In the ABR protocol, automatic waveform marking allows time-saving measurement of latency, amplitude, and interval. Side comparison Split screen display allows for side comparisons at a glance. The superimposed waveform in real in the same protocol. time is shown at the same time, so you can easily compare the amplitudes of all stimulation sites and thus judge the quality of your stimulation.

Specifications Amplifier Number of channels: JB-942: 2, JB-944: 4 Input impedance: >200 MΩ (differential mode), 1000 MΩ (common mode) Noise: <0.6 µvrms or less at 1 Hz to 10 khz with input shorted Sensitivity: 1, 2, 5, 10, 20, 50, 100, 200, 500 µv/div, 1, 2, 5, 10 mv/div ±5% High cut filter: 10, 20, 50, 100, 200, 500 Hz, 1, 1.5, 2, 3, 5, 10, 20 khz at 12 db/oct (±20%) AC interference notch filter: 50 or 60 Hz (rejection ratio: <1/2-0) Amplitude calibration: 1, 10, 100 µv, 1, 10mV (within ±5%) Skin-electrode contact impedance check: 2, 5, 10, 20 kω indication (within ±20%) Low cut filter: 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 3 khz 6 db/oct (±20%) Dimensions and Weight Main unit: 350 (W) x 62 (H) x 395 (D) mm, 3.0 kg PC Unit depends on the model selected JB-942 amplifier: 217 (W) x 174 (H) x 34 (D) mm,.71 kg JB-944 amplifier: 217 (W) x 174 (H) x 34 (D) mm,.74 kg Power Requirements Line voltage: 100 to 240 V AC ±10% Line Frequency: 50/60 Hz Power input: 75 VA (DC-110B) Environment Operating temperature: 10 to 35 C (50 to 95 F) Operating humidity: 30% to 80% Operating atmospheric pressure: 70 to 106 kpa Storage temperature: -20 to +65 C (-4 to 149 F) Storage humidity: 20 to 80% Storage atmospheric pressure: 70 to 106 kpa us.nihonkohden.com NMLB 047 [G]-CO-0467 NeuroReport is a trademark and, NeuroNavi and NeuroWorkbench are registered trademarks of Nihon Kohden Corporation.