Product Data and Specifications. Spiral Duct Systems For all HVAC Requirements

Similar documents
SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

FINAL December 2012 SECTION DUCTWORK

FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS

SECTION STANDING SEAM METAL ROOFING

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Section SEWER PIPE INSTALLATION AND TESTING

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Section 402. STORM SEWERS

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

SECTION PIPE HANGERS AND SUPPORTS

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Zero peel strength of acrylic pressure sensitive adhesive is at about 45 C (-50 F).

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

DIVISION 4300 STORM DRAINAGE

B. Types of mechanical insulation specified in this section include the following:

SECTION FIRE HYDRANTS

2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61

GUIDELINE SPECIFICATIONS

INDEX. Sec. No. Items Page Nos.

SECTION STORM DRAINAGE SYSTEM

Section 2100-Trenching and Tunneling

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

HVAC Duct Construction. Bob Wasilewski Project Manager, Technical Resources SMACNA

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

Heating, Ventilation & Air Conditioning

Quick response concealed horizontal sidewall sprinkler

Wastewater Capital Projects Management Standard Construction Specification

PART 1 GENERAL 1.1 SECTION INCLUDES

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

SECTION POLYVINYL CHLORIDE (PVC) PIPE

CHAPTER 7: Building Systems ROOFING SYSTEMS

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

Fire Barrier Duct Wrap 15A

HexWeb CR III Corrosion Resistant Specification Grade Aluminum Honeycomb

James M. Pleasants Company

Roof Curbs, Extensions and Equipment Supports

SECTION UNDERGROUND ELECTRIC SERVICE

SECTION 1 GENERAL REQUIREMENTS

Guide Specifications for Maple Flooring Systems

SANITARY SEWER SPECIFICATIONS

Bafl-Sorb Sound Absorbing Ceiling Baffles

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

Please read the entire document before purchasing and installing any of these products

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

TARIFF CODE and updates standard

Series 4000 Fiberglass Pipe and Fittings

CULVERT AND STORM SEWER PIPE MATERIAL POLICY ON FEDERALLY FUNDED LOCAL AGENCY PROJECTS UPDATED March 2013

COATING & WRAPPING OF UNDERGROUND PIPING

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

SECTION PREFORMED METAL STANDING SEAM ROOFING

Exhaust Calculation Booklet

Phosphoric Acid Anodized Aluminum Honeycomb

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

The EDGE Self-Sealing Round Duct System

Product Guide Specification

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Air-side Systems: Air Duct Design

SECTION STORM DRAIN SYSTEM

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

4 Installation Requirements

SUBMITTAL 10 FEET. Cast Iron Soil Pipe Products Hubless Pipe & Fittings HUBLESS PIPE 10 FEET*

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

security products metric sizes Redefine your comfort zone.

STOCK LIST & BUYER S GUIDE

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

Scepter PVC Molded Junction Boxes

Product Guide Specification

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

INSTALLATION GUIDE. americanwick.com WICK (9425)

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

X Planning X Quality X Maintenance & Operations

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

DESIGN GUIDELINES FOR LTCC

SECTION GROUND WATER STORAGE TANKS

SECTION 724 PIPE CULVERTS

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

During severe flood events, such as those

Mechanical arms, belts and sheets

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Transcription:

Product Data and Specifications Spiral Duct Systems For all HVAC Requirements

STANDARDS FINISHES/ OPTIONS/ SIZES COST RATIO RELATED CONFORMANCE COLORS ACCESSORIES INDEX DATA - Galvanized steel. - Satin coat steel (see below) - Stainless steel (Type 304-2B or 316-2B finish). - Aluminum (Alloy 3003- H14) - P.V.S. (Polyvinyl Steel). White is standard. - Other finishes available upon request. - Galvanized steel. - Recommended that exposed systems that are to be painted be fabricated using satin coat material (saves expense of etching galvanized material before painting). - All associated metal fittings. - Top grade U.L.C. sealers and tapes. - Insulation liner with perforated metal inner wall (see Acoustic- Thermal Duct below for liner specifications). - As above - Available 3 to 80 diameter in all common sizes. - 10-0 length is standard. Other lengths available upon request. - Gauges conform to and standards. - Available 3 to 80 diameter in all common sizes. - 10 0 length is standard. Other lengths available upon request. - 28 gauge thickness is standard (26 gauge optional). - 100% - 70% - Insulation conforms to U.L.C. 181 and NFPA 90A- 1985. - U.L.C. Listed - As above - All associated metal fittings. - Top grade U.L.C. sealers and tapes. - As above - 250% - For acoustical/thermal data, refer to guides. - U.L.C. Listed for Class A duct system (Nonflammable). - White is standard - All associated metal fittings. - Top grade sealers and tapes as per P.V.S. supplier s recommendations. - Flat P.V.S. sheet also available for custom fabrication e.g. rectangular duct, etc. - Available 3 to 60 diameter in all common sizes. - 10-0 length is standard. Other lengths available upon request. - Gauges conform to and standards. - 300% - Substantially lower than stainless steel which is commonly used for exhaust systems. Maximum Hydrostatic Pressures Limited by Seam Failure (psi) Dia. 3 4 5 6 7 8 9 10 12 14 16 18 20 22 24 26 28 30 32 26 Ga. 420 308 238 199 169 145 127 113 93 76 68 24 Ga. 535 392 303 252 216 186 161 144 118 100 86 75 66 60 22 Ga. 650 475 369 308 262 224 196 177 145 120 103 91 81 72 66 61 55 51 47 *Cost Ratio Index based on 100% for Free Flow Spiral Duct with galvanized steel finish. Relative cost of all other duct products are either above or below this figure.

FITTINGS Alpha Free Flow manufactures a complete line of fittings in gauges to match the spiral duct application and are designed especially for use with spiral duct. Jobsite conditions may require fittings other than those shown below however any type of fitting is available upon request. The inner shell of Acoustic-Thermal double walled duct fittings are 2 longer at all openings to allow for easy assembly. C2-90 90 Cross D, A, B L=Larger tap diameter + 3 CROSSES CR2-90 90 Cross With Reducer Dimensions to be listed in ordering D, A, B, O L=Larger tap diameter + ( D-O ) + 3 Length of all on center reducing sections are (D-O) with a minimum length of 4 inches. C4-90 90 Double Branch Cross D, A, B, C, E L=A+B (whichever is larger) + 5 or C+E CR2-180 180 Cross With Reducer D, A, B, O L=Larger tap diameter + ( D-O ) + 3 CR4-180 180 Double Branch Cross With Reducer D, A, B, C, E, O L=A+B (whichever is larger) + ( D-O ) + 5 or C+E C4-180 180 Double Branch Cross D, A, B, C, E L=A+B (whichever is larger) + 5 or C+E C2-180 180 Cross D, A, B L=Larger tap diameter + 3 T2-90 90 Double Branch Tee D, A, B L = A+B+5 TT1-90 90 Tangential Tee D, A, L= A+3 TEES TR1-90 90 Tee With Reducer D, A, O L= A+ ( D-O ) + 3 TR2-90 90 Double Branch Tee With Reducer D, A, B, O L = A+ B+ ( D-O ) + 5 T1-90 90 Tee D, A L= A+3

ELBOWS E1-90 90 2-Piece Elbow D R=1.5 x D E1-45 45 2-Piece Elbow D Center-line radius = 1.5 x D E5-90 90 Elbow D Center-line radius = 1.5 x D E3-45 45 Elbow Dimension to be listed in ordering: D Center-line radius = 1.5 x D 45 LATERALS L2-45 45 Double Lateral D, A, B L = 1.414 ( A+B) + 5 LR2-45 45 Double Lateral With Reducer D, A, B, O L = 1.414 (A+B) + ( D-O ) + 5 CLR2-45 45 Double Lateral Cross With Reducer D, A, B, O L = 1.414 (Larger tap diameter) + ( D-O ) + 3 L1-45 45 Lateral D, A L = A(1.414) + 3 CL2-45 45 Double Lateral Cross D, A, B L = 1.414 (Larger tap diameter) + 3 LR1-45 45 Lateral With Reducer L = A(1.414) + ( D-O ) + 3 Y2-45 45 Two-Way Y D, A, B MISCELLANEOUS Con T1-90 90 Conical Tee D, A L = A +5 Con TR1-90 90 Conical Tee With Reducer D, A, O L = A + ( D-O ) + 5 Con C2-180 180 Conical Cross D, A, B L = Larger tap diameter + 5 Con CR2-180 180 Conical Cross With Reducer D, A, B, O L = Larger tap diameter + ( D-O ) + 5 CR Equal Change Reducer D, O L = (D-O) imum length SC Pipe Coupling D EC-1 End Cap (for duct) EC-2 End Cap (for fittings) (Specify which is necessary) D SR Straight Side Reducer D, O L = 2(D-O) imum length

SPIRAL DUCT SELECTION GUIDE PRODUCT DESCRIPTION RECOMMENDED USES SPECIAL FEATURES Free-flow Spiral Duct Section through strip width - Single wall round duct of helicoidal 4-ply spiral lockseam construction with tightly closed joints to provide smooth interior. - Made from G60 galvanized steel conforming to ASTM A525-83. - Matching fittings available. - Available insulated with interior metal liner (perforated or unperforated). See Acoustic-Thermal Duct below. - Uses slip type transverse joint or Spirmir Self Sealing System. Companion angle flanged joint recommended for ducts over 60 diameter. institutional projects. - For high negative pressures - For all static pressure classes (1/2 to +10 w.g.). - Specify P.V.S. (Polyvinyl Steel) for under-slab air duct and for corrosive fumes. See below. - For agricultural use. - May also be used for culverts, drains, and dust collection systems. - Round duct can be used to great advantage over rectangular duct due to round duct structural strength and rigidity, important factors in avoiding noise generation, external damage and duct collapse. - Round duct is normally offered in longer lengths and fewer joints, resulting in reduced friction losses, leakage at joints and installation costs. - Available in a wide variety of materials. Multi-rib Spiral Duct Section through strip width - Single wall round duct of helicoidal 4-ply spiral lockseam construction with 3 intermediate standing ribs. Also available 1 or 2 ribs at nominal extra cost. - Made from G60 galvanized steel conforming to ASTM A525-83. - Matching fittings available. - Available insulated with or without perforated metal liner. - Uses slip type transverse joint. Companion angle flanged joint recommended for ducts over 60 diameter. institution projects wherever a low pressure duct system is required. - Maximum 2 w.g. static positive. - Best quality for least expense in systems that have less than 2 w.g. static pressure. - See round duct features above. Acoustic Thermal Duct Section through strip width - Double walled round duct with fiberglass insulation liner. Consists of outer skin of Free-Flow Spiral Duct as described above, 1 or 2 thickness 3/4 lb. density fiberglass, and standard interior liner of 26-24 guage G60 galvanized steel Multi- Rib Spiral Duct (as described above) perforated with 3/32 diameter holes staggered 3/16 o.c. (available unperforated for thermal use only). - Low pressure duct (2 w.g. or less) can be supplied with outer skin of Free-Flow spiral duct and interior duct liner insulation only (no interior metal liner) if desired. - Matching fittings available. - Uses slip type transverse joint or Spirmir Self Sealing System. Companion angle flanged joint recommended for ducts over 60 diameter. institutional projects. - For all static pressure classes (1/2 to 10 w.g.). - For maximum noise control and/or thermal efficiency. - See Multi-Rib Spiral Duct above. - Provides high STL (Sound Transmission Loss) through duct walls. - Minimizes noise and sound transmission in duct system. - Minimizes heat loss and provides positive vapour barrier. - Provides double fire protection. - Provides uniform insulation thickness. P.V.S. Spiral Duct (For Under-slab And Corrosive Fumes) Type 1 Smooth Wall Type 2 External Corrugations Section through strip widths - Patented single wall round duct of helicoidal 4-ply spiral lockseam construction with tightly closed joints. - P.V.S. consists of a prime quality G90 galvanized steel with a 4 mil thickness pvc coating fused to both sides using a patented process. - Available unreinforced (Type 1) or with external reinforcing corrugations (Type 2) which increases rigidity of duct by approximately 300%. - Smooth glass-like interior surface of Type 1 (uninreinforced) duct reduces air flow friction to near zero. - Weighs only 1/3 as much as traditional materials such as concrete; reduces labor costs. - Uses slip type transverse joint or Spirmir Self Sealing System. institutional projects. - For all static pressure classes (1/2 to 10 w.g.). - Under-slab air duct. - Ducting for corrosive fumes. - Load limits* - (Type 1-Smooth Wall) 4-8 dia. = 400 lbs. / lin. ft. 10-36 dia. = 800 lbs. / lin. ft. (Type 2 Reinforcing Ribs) 4-8 dia. = 1200 lbs. / lin. ft. - Above weights apply when P.V.S. is installed as recommended with equal compaction in back filling. - Will not rust, chip crack, peel, corrode or produce odors. U.L.C. Tested and labeled. - Light in weight possesses high crushing strength and will not collapse with weight of concrete when poured equally - Can be stacked outdoors without cover, in any weather. - Unaffected by concrete and normal back filling materials. Reagents and test data available upon request. P.V.S. has also passed thousands of hours of accelerated salt spray, humidity cabinet, and water immersion tests with no loss of adhesion or corrosive action. - May be exposed to continuous temperatures ranging from -40 F to 200 F. - Does not need to be encased in concrete, or propped up or tied down. Only a shallow trench is required. No encasement means substantial savings over poured concrete.

1080 Meyerside Drive, Mississauga, ON TF: 1.800.268.3873 T: 905.670.1164 F: 905.670.7914 MEMBER: (Sheet Metal and Air Conditioning Ontario Sheet Metal and Air Handling Group (Spiral Duct Manufacturers Association) Contractors National Association, Inc.