CUSTOM DURAMARK PIPE MARKERS CRAFTMARK PIPE MARKERS SINCE Product MasterSpec CRAFTMARK U.S.A EDITION

Similar documents
A. Shop Drawing submittals shall include, but not be limited to, the following:

IDENTIFICATION FOR PIPING AND EQUIPMENT

Facility Operations Physical Safety Guidance Document

FIRING RANGE PHASE 1 DESIGN

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

EMERGENCY PLUMBING FIXTURES

CRAFTMARK CABLE MARKING PRODUCTS. SINCE 1959 The SNAP ON Marker Experts. CRAFTMARK U.S.A EDITION CMF-9

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

B. Types of mechanical insulation specified in this section include the following:

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

Walmart 4th Wall. Advertising and Lease Line Guidelines. June Customerexperience

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

DIN 2403 Identification of pipelines according to the fluid conveyed. Marking of pipes according to fluid transported

MECHANICAL PIPING PAINTING & IDENTIFICATION REQUIREMENTS

4 Installation Requirements

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

SECTION COMMERCIAL PLUMBING FIXTURES

Element D Services Plumbing

Industry s leader in labeling, graphics & identification CALL (847)

TABLE OF CONTENTS INTERIOR BANNER DISPLAYS 2-4 LIGHT BOX DISPLAYS 5 EXTERIOR SIGN DISPLAYS 6 HARDWARE 7-9

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

SECTION MORTUARY REFRIGERATORS

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Food Safety Starts with Workplace Safety Workplace Safety Products For Food and Beverage Processing Facilities

Window Installation Instructions

Autobody/Collision and Repair Technology/Technician CIP Task Grid

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Automatic Door Selection Guide

Packaged Terminal Air Conditioner Wall Sleeve Installation

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

PART 1 GENERAL 1.1 SECTION INCLUDES

presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13

Product Guide Specification

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Building Code Clarifications - 7. Fire Resistance

B. Shop Drawings: Diagram power, signal, and control wiring.

3M Dual Lock Reclosable Fastener

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

CLEAR-DIVISIONS CENTERFOLD

Reflective Safety Products. Home Automotive Commercial

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

General Fire Code Requirements Within Commercial Tenant Spaces

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

9300BC SERIES Light Commercial Door Closer

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

PUBLIC RESTROOMS, DESIGN INTENT

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

SECTION FACILITY STORM DRAINAGE PIPING

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

2.9 WINDOW & DOOR BUCKS

COMMISSIONING OF HVAC SYSTEMS

Mobile Home Pre-Inspection Checklist

Bafl-Sorb Sound Absorbing Ceiling Baffles

SECTION HVAC INSULATION

Printed carriers and labels

Pipe Temperature Sensors

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

Confort 26. Sliding Systems. Sapa Building System

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

SECTION GENERAL PROVISIONS FOR HVAC WORK

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

RMF Engineering

Acumen Enterprises, Inc.

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Before installation it is important to know what parts you have and what the capabilities of these parts are.

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

HOSE & CABLE PROTECTION

Introduction... 3 Setting the Combination... 4 Securing the DEFCON CL... 5 Locking the DEFCON CL to your Notebook Computer...

The Anatomy of a Label

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cooktop Low-Profile Ventilation Hoods

SECTION FIRE HYDRANTS

CHALKBOARDS, MARKERBOARDS, TACKBOARDS, DISPLAY CASES, AND BULLETIN BOARD CABINETS

Irvinton Village Apartments 2901 Fulton Houston, Texas Houston Housing Authority J. Allen Management Managing Agent

CLEAR-DIVISIONS VARIOFOLD

Pre-Cut Sauna Specifications

1805 Series Relief Valves

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

SECTION STANDING SEAM METAL ROOFING

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Transcription:

CUSTOM DURAMARK PIPE MARKERS CRAFTMARK PIPE MARKERS SINCE 1959 Product MasterSpec 230553 CRAFTMARK U.S.A. 2012 EDITION

This Product MasterSpec Section is licensed by ARCOM to Craftmark Pipe Markers ("Licensee"). This Product MasterSpec Section modifies the original MasterSpec text, and does not include the full content of the original MasterSpec Section. Revisions made to the original MasterSpec text are made solely by the Licensee and are not endorsed by, or representative of the opinions of, ARCOM or The American Institute of Architects (AIA). Neither AIA nor ARCOM are liable in any way for such revisions or for the use of this Product MasterSpec Section by any end user. A qualified design professional should review and edit the document to suit project requirements. For more information, contact Craftmark Pipe Markers, 3212 S. Cravens Rd., Fort Worth, TX 76119; Phone: (800) 627-5255; Fax: (800) 889-3147; Website: www.craftmarkpipemarkers.com; Email: sales@craftmarkpipemarkers.com. For information about MasterSpec contact ARCOM at (800) 424-5080 or visit www.masterspec.com. SECTION 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Equipment labels. 2. Warning signs and labels. 3. Pipe labels. 4. Duct labels. 5. Stencils. 6. Valve tags. 7. Warning tags. 1.3 ACTION SUBMITTALS A. Product Data: For each type of product indicated. B. Samples: For color, letter style, and graphic representation required for each identification material and device. C. Equipment Label Schedule: Include a listing of all equipment to be labeled with the proposed content for each label. IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553-1

D. Valve numbering scheme. E. Valve Schedules: For each piping system to include in maintenance manuals. 1.4 COORDINATION A. Coordinate installation of identifying devices with completion of covering and painting of surfaces where devices are to be applied. B. Coordinate installation of identifying devices with locations of access panels and doors. C. Install identifying devices before installing acoustical ceilings and similar concealment. PART 2 - PRODUCTS 2.1 EQUIPMENT LABELS A. Metal Labels for Equipment: 1. Basis-of-Design Product: Craftmark Pipe Markers; [Anodized Aluminum Nameplates] [Stainless Steel Engraved Nameplates] [Brass Engraved Nameplates]. 2. Subject to compliance with requirements, provide the Basis-of-Design Product or comparable product by one of the following: a. Brady, Inc. b. Seton, Inc. c. <Insert manufacturer's name>. 3. Material and Thickness: [Brass, 0.036-inch (0.9-mm)] [Stainless steel, 0.025-inch (0.64- mm)] [Aluminum, 0.032-inch (0.8-mm)] [or] [anodized aluminum, 0.032-inch (0.8-mm)] minimum thickness, and having predrilled or stamped holes for attachment hardware. 4. Minimum Label Size: Length and width vary for required label content, but not less than 2-1/2 by 3/4 inch (64 by 19 mm). 5. Minimum Letter Size: 1/4 inch (6.4 mm) for name of units if viewing distance is less than 24 inches (600 mm), 1/2 inch (13 mm) for viewing distances up to 72 inches (1830 mm), and proportionately larger lettering for greater viewing distances. Include secondary lettering twothirds to three-fourths the size of principal lettering. 6. Fasteners: Stainless-steel [rivets] [rivets or self-tapping screws] [self-tapping screws]. 7. Adhesive: Contact-type permanent adhesive, compatible with label and with substrate. B. Plastic Labels for Equipment: 1. Basis-of-Design Product: Craftmark Pipe Markers; Craftflex Multilayer, Multicolor Plastic Nameplates. 2. Subject to compliance with requirements, provide the Basis-of-Design Product or comparable product by one of the following: IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553-2

a. Brady, Inc. b. Seton, Inc. c. <Insert manufacturer's name>. 3. Material and Thickness: Multilayer, multicolor, plastic labels for mechanical engraving, [1/16 inch (1.6 mm)] [1/8 inch (3.2 mm)] <Insert dimension> thick, and having predrilled holes for attachment hardware. 4. Letter Color: [Black] [Blue] [Red] [White] [Yellow] [Green]. 5. Background Color: [Black] [Blue] [Red] [White] [Yellow] [Green]. 6. Maximum Temperature: Able to withstand temperatures up to 180 deg F (82 deg C). 7. Minimum Label Size: Length and width vary for required label content, but not less than 2-1/2 by 3/4 inch (64 by 19 mm). 8. Minimum Letter Size: 1/4 inch (6.4 mm) for name of units if viewing distance is less than 24 inches (600 mm), 1/2 inch (13 mm) for viewing distances up to 72 inches (1830 mm), and proportionately larger lettering for greater viewing distances. Include secondary lettering twothirds to three-fourths the size of principal lettering. 9. Fasteners: Stainless-steel [rivets] [rivets or self-tapping screws] [self-tapping screws]. 10. Adhesive: Contact-type permanent adhesive, compatible with label and with substrate. C. Label Content: Include equipment's Drawing designation or unique equipment number, Drawing numbers where equipment is indicated (plans, details, and schedules), plus the Specification Section number and title where equipment is specified. D. Equipment Label Schedule: For each item of equipment to be labeled, on 8-1/2-by-11-inch (A4) bond paper. Tabulate equipment identification number and identify Drawing numbers where equipment is indicated (plans, details, and schedules), plus the Specification Section number and title where equipment is specified. Equipment schedule shall be included in operation and maintenance data. 2.2 WARNING SIGNS AND LABELS A. Basis-of-Design Product: Craftmark Pipe Markers; Warning Signs and Labels. B. Subject to compliance with requirements, provide the Basis-of-Design Product or comparable product by one of the following: 1. Brady, Inc. 2. Seton, Inc. 3. <Insert manufacturer's name>. C. Material and Thickness: [Adhesive-backed vinyl 0.005inches (0.13 mm)] [Aluminum 0.04 inch (1.02 mm)] [Polystyrene 0.060 inch (1.524-mm)] thick, and having predrilled holes for attachment hardware. D. Letter Color: [Black] [Blue] [Red] [White] [Yellow] [Green] <Insert color>. E. Background Color: [Black] [Blue] [Red] [White] [Yellow] [Green] <Insert color>. F. Fasteners: Stainless-steel [rivets] [rivets or self-tapping screws] [self-tapping screws]. G. Adhesive: Contact-type permanent adhesive, compatible with label and with substrate. IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553-3

H. Label Content: Include [Caution] [Danger] [Notice] [Warning] information, plus emergency notification instructions. 2.3 PIPE LABELS A. General Requirements for Manufactured Pipe Labels: Preprinted, color-coded, with lettering indicating service, and showing flow direction. Manufacturers standard legends and colors should be used whenever possible. Pipe marker color field and legend height shall comply with ASME/ANSE A 13.1 specifications. B. Pretensioned Pipe Labels: Precoiled, semirigid plastic formed to [partially cover] [cover full] circumference of pipe and to attach to pipe without fasteners or adhesive. 1. Basis-of-Design Product: Craftmark Pipe Markers; Specmark Snap-on Markers. 2. Subject to compliance with requirements, provide the Basis-of-Design Product or comparable product by one of the following: a. Brady, Inc. b. Seton, Inc. c. <Insert manufacturer's name>. 3. For pipe sizes NP5 5 (DN125) and smaller including pipe insulation: semi-rigid plastic wraparound pipe markers that extend 360 degrees around pipe at each marker location. Include legend (pipe content) and arrows to indicate direction of flow. 4. For pipe sizes NP5 5 (DN125) and larger including pipe installation: Semi-rigid plastic strap-on pipe markers. Include legend (pipe content), and arrows to indicate direction of flow. Include at least 2 nylon straps to secure marker to pipe. C. Self-Adhesive Pipe Labels: Printed plastic with contact-type, permanent-adhesive backing. 1. Basis-of-Design Product: Craftmark Pipe Markers; Duramark Self-Stick Markers. 2. Subject to compliance with requirements, provide the Basis-of-Design Product or comparable product by one of the following: a. Brady, Inc. b. Seton, Inc. c. <Insert manufacturer's name>. D. Exterior Pretensioned Pipe Labels: Pre-coiled, semi-rigid plastic formed to [partially cover] [cover full] circumference of pipe and to attach to pipe without fasteners or adhesive. 1. Basis-of-Design Product: Craftmark Pipe Markers; Specmark HT Extreme Environmental Markers. 2. Subject to compliance with requirements, provide the Basis-of-Design Product or comparable product by one of the following: a. Brady, Inc. IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553-4

b. Seton, Inc. c. <Insert manufacturer's name>. 3. For pipe sizes NP5 6 (DN150) or smaller including pipe insulation: Semi-rigid plastic wraparound pipe markers. Include legend (pipe content) and arrows to indicate direction of flow. Include at least 2 nylon straps to secure marker to pipe. 4. For pipe sizes NPS 6 (DN150) or larger: rigid 0.090 inches (2.3 mm) fiberglass carrier with high temp adhesive back pipe marker attached to surface. Include legend (pipe content) and arrow to indicate direction of flow. Include at least 2 nylon straps to secure marker to pipe. E. Pipe Label Contents: Include identification of piping service using same designations or abbreviations as used on Drawings, pipe size, and an arrow indicating flow direction. 1. Flow-Direction Arrows: Integral with piping system service lettering to accommodate both directions, or as separate unit on each pipe label to indicate flow direction. 2. Lettering Size: At least 1-1/2 inches (38 mm)high. 2.4 DUCT LABELS A. Basis-of-Design Product: Craftmark Pipe Markers; Engraved Craftflex Plastic Nameplate. B. Subject to compliance with requirements, provide the Basis-of-Design Product or comparable product by one of the following: 1. Brady, Inc. 2. Seton, Inc. 3. <Insert manufacturer's name>. C. Material and Thickness: Multilayer, multicolor, plastic labels for mechanical engraving, [1/16 inch (1.6 mm)] [1/8 inch (3.2 mm)] <Insert dimension> thick, and having predrilled holes for attachment hardware. D. Letter Color: [Black] [Blue] [Red] [White] [Yellow] [Green]. E. Background Color: [Black] [Blue] [Red] [White] [Yellow] [Green]. F. Maximum Temperature: Able to withstand temperatures up to 180 deg F (82 deg C). G. Minimum Label Size: Length and width vary for required label content, but not less than 2-1/2 by 3/4 inch (64 by 19 mm). H. Minimum Letter Size: 1/4 inch (6.4 mm) for name of units if viewing distance is less than 24 inches (600 mm), 1/2 inch (13 mm) for viewing distances up to 72 inches (1830 mm), and proportionately larger lettering for greater viewing distances. Include secondary lettering two-thirds to three-fourths the size of principal lettering. I. Fasteners: Stainless-steel [rivets] [rivets or self-tapping screws] [self-tapping screws]. J. Adhesive: Contact-type permanent adhesive, compatible with label and with substrate. IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553-5

K. Duct Label Content: Include identification of duct service using same designations or abbreviations as used on Drawings, duct size, and an arrow indicating flow direction. 1. Flow-Direction Arrows: Integral with duct system service lettering to accommodate both directions, or as separate unit on each duct label to indicate flow direction. 2. Lettering Size: At least 1-1/2 inches (38 mm) high. 2.5 STENCILS A. Basis-of-Design Product: Craftmark Pipe Markers; Plastic Stencils. B. Subject to compliance with requirements, provide the Basis-of-Design Product or comparable product by one of the following: 1. Seton, Inc. 2. <Insert manufacturer's name>. C. Stencils: Prepared with letter sizes according to ASME A13.1 for piping; minimum letter height of 1-1/4 inches (32 mm) for ducts; and minimum letter height of 3/4 inch (19 mm) for access panel and door labels, equipment labels, and similar operational instructions. 1. Stencil Material: [Aluminum] [Brass] [Fiberboard] [Fiberboard or metal] [Polyester 0.02 inch (0.51 mm)] <Insert material>. 2. Stencil Paint: Exterior, gloss, [alkyd enamel] [acrylic enamel] <Insert paint type> black unless otherwise indicated. Paint may be in pressurized spray-can form. 3. Identification Paint: Exterior, [alkyd enamel] [acrylic enamel] <Insert paint type> in colors according to ASME A13.1 unless otherwise indicated. 2.6 VALVE TAGS A. Basis-of-Design Product: Craftmark Pipe Markers; Valve Tags. B. Subject to compliance with requirements, provide the Basis-of-Design Product or comparable product by one of the following: 1. Brady, Inc. 2. Seton, Inc. 3. <Insert manufacturer's name>. C. Valve Tags: Stamped or engraved with 1/4-inch (6.4-mm) letters for piping system abbreviation and 1/2-inch (13-mm) numbers. 1. Tag Material: [Brass, 0.036-inch (0.9-mm)] [Stainless steel, 0.025-inch (0.64-mm)] [Aluminum, 0.032-inch (0.8-mm)] [or] [anodized aluminum, 0.032-inch (0.8-mm)] [0.125- inch (3.175 mm)] [Plastic engraved 0.062 inch (1.57 mm)] <Insert thickness> minimum thickness, and having predrilled or stamped holes for attachment hardware. 2. Fasteners: [Brass #16 jack chain, #6 beaded chain; or S-hook] [Stainless steel #16 jack chain, #6 beaded chain, or S-hook]. IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553-6

D. Valve Schedules: For each piping system, on 8-1/2-by-11-inch (A4) bond paper. Tabulate valve number, piping system, system abbreviation (as shown on valve tag), location of valve (room or space), normal-operating position (open, closed, or modulating), and variations for identification. Mark valves for emergency shutoff and similar special uses. 1. Valve-tag schedule shall be included in operation and maintenance data. 2.7 WARNING TAGS A. Basis-of-Design Product: Craftmark Pipe Markers; Accident Prevention Tags. B. Subject to compliance with requirements, provide the Basis-of-Design Product or comparable product by one of the following: 1. Brady, Inc. 2. Seton, Inc. 3. <Insert manufacturer's name>. C. Warning Tags: Preprinted or partially preprinted, accident-prevention tags, of polystyrene material with matte finish suitable for writing, and with grommeted hole. 1. Warning Tag Material: 0.20 inch (0.51 mm) polystyrene. 2. Fasteners: [6 inch (152 mm) nylon tie] [8 inch (203 mm)]. 3. Nomenclature: Large-size primary caption such as "DANGER," "CAUTION," "WARNING", or "DO NOT OPERATE." 4. Color: [Red/Black on white background] [Yellow/Black on white background] [Orange/Black on white background] <Insert color>. PART 3 - EXECUTION 3.1 PREPARATION A. Clean piping and equipment surfaces of substances that could impair bond of identification devices, including dirt, oil, grease, release agents, and incompatible primers, paints, and encapsulants. 3.2 EQUIPMENT LABEL INSTALLATION A. Install or permanently fasten labels on each major item of mechanical equipment. B. Locate equipment labels where accessible and visible. 3.3 PIPE LABEL INSTALLATION A. Piping Color-Coding: Painting of piping is specified in [Section 099123 "Interior Painting"] [Section 099600 "High Performance Coatings"] IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553-7

B. Stenciled Pipe Label Option: Stenciled labels may be provided instead of manufactured pipe labels, at Installer's option. Install stenciled pipe labels [with painted, color-coded bands or rectangles] [, complying with ASME A13.1,] on each piping system. 1. Identification Paint: Use for contrasting background. 2. Stencil Paint: Use for pipe marking. C. Locate pipe labels where piping is exposed or above accessible ceilings in finished spaces; machine rooms; accessible maintenance spaces such as shafts, tunnels, and plenums; and exterior exposed locations as follows: 1. Near each valve and control device. 2. Near each branch connection, excluding short takeoffs for fixtures and terminal units. Where flow pattern is not obvious, mark each pipe at branch. 3. Near penetrations through walls, floors, ceilings, and inaccessible enclosures. 4. At access doors, manholes, and similar access points that permit view of concealed piping. 5. Near major equipment items and other points of origination and termination. 6. Spaced at maximum intervals of [50 feet (15 m)] <Insert dimension> along each run. Reduce intervals to [25 feet (7.6 m)] <Insert dimension> in areas of congested piping and equipment. 7. On piping above removable acoustical ceilings. Omit intermediately spaced labels. D. Pipe Label Color Schedule: 1. Chilled-Water Piping: 2. Condenser-Water Piping: 3. Heating Water Piping: 4. Refrigerant Piping: 5. Low-Pressure Steam Piping: 6. High-Pressure Steam Piping: IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553-8

7. Steam Condensate Piping: 3.4 DUCT LABEL INSTALLATION A. Install [plastic-laminated] [self-adhesive] duct labels with permanent adhesive on air ducts in the following color codes: 1. [Blue] <Insert color>: For cold-air supply ducts. 2. [Yellow] <Insert color>: For hot-air supply ducts. 3. [Green] <Insert color>: For exhaust-, outside-, relief-, return-, and mixed-air ducts. 4. ASME A13.1 Colors and Designs: For hazardous material exhaust. B. Stenciled Duct Label Option: Stenciled labels, showing service and flow direction, may be provided instead of plastic-laminated duct labels, at Installer's option, if lettering larger than 1 inch (25 mm) high is needed for proper identification because of distance from normal location of required identification. C. Locate labels near points where ducts enter into concealed spaces and at maximum intervals of [50 feet (15 m)] <Insert dimension> in each space where ducts are exposed or concealed by removable ceiling system. 3.5 VALVE-TAG INSTALLATION A. Install tags on valves and control devices in piping systems, except check valves; valves within factory-fabricated equipment units; shutoff valves; faucets; convenience and lawn-watering hose connections; and HVAC terminal devices and similar roughing-in connections of end-use fixtures and units. List tagged valves in a valve schedule. B. Valve-Tag Application Schedule: Tag valves according to size, shape, and color scheme and with captions similar to those indicated in the following subparagraphs: 1. Valve-Tag Size and Shape: a. Chilled Water: [1-1/2 inches (38 mm)] [2 inches (50 mm)], [round] [square] <Insert shape>. b. Condenser Water: [1-1/2 inches (38 mm)] [2 inches (50 mm)], [round] [square] <Insert shape>. c. Refrigerant: [1-1/2 inches (38 mm)] [2 inches (50 mm)], [round] [square] <Insert shape>. d. Hot Water: [1-1/2 inches (38 mm)] [2 inches (50 mm)], [round] [square] <Insert shape>. e. Gas: [1-1/2 inches (38 mm)] [2 inches (50 mm)], [round] [square] <Insert shape>. f. Low-Pressure Steam: [1-1/2 inches (38 mm)] [2 inches (50 mm)], [round] [square] <Insert shape>. IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553-9

g. High-Pressure Steam: [1-1/2 inches (38 mm)] [2 inches (50 mm)], [round] [square] <Insert shape>. h. Steam Condensate: [1-1/2 inches (38 mm)] [2 inches (50 mm)], [round] [square] <Insert shape>. 2. Valve-Tag Color: a. Chilled Water: [Natural] [Green] <Insert color>. b. Condenser Water: [Natural] [Green] <Insert color>. c. Refrigerant: [Natural] [Green] <Insert color>. d. Hot Water: [Natural] [Green] <Insert color>. e. Gas: [Natural] [Yellow] <Insert color>. f. Low-Pressure Steam: [Natural] [Yellow] <Insert color>. g. High-Pressure Steam: [Natural] [Green] <Insert color>. h. Steam Condensate: [Natural] [Green] <Insert color>. 3. Letter Color: a. Chilled Water: [Black] [White] <Insert color>. b. Condenser Water: [Black] [White] <Insert color>. c. Refrigerant: [Black] [White] <Insert color>. d. Hot Water: [Black] [White] <Insert color>. e. Gas: [Black] [White] <Insert color>. f. Low-Pressure Steam: [Black] [White] <Insert color>. g. High-Pressure Steam: [Black] [White] <Insert color>. h. Steam Condensate: [Black] [White] <Insert color>. 3.6 WARNING-TAG INSTALLATION A. Write required message on, and attach warning tags to, equipment and other items where required. END OF SECTION 230553 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553-10

R CRAFTMARK PIPE MARKERS SINCE 1959 U.S. WORLD HEADQUARTERS 1.800.627.5255-Phone 1.800.889.3147-Fax www.craftmarkpipemarkers.com INTERNATIONAL SALES 011.817.457.5162-Phone 011.817.498.9659-Fax U.S.A. Canada ASIA ENGLAND DUBAI EUROPE MIDDLE EAST MEXICO S. AMERICA S. AFRICA www.craftmarkid.com www.craftmarkcanada.com www.craftmarkasia.com www.craftmarkengland.com www.craftmarkdubai.com www.craftmarkeurope.com www.craftmarkmiddleeast.com www.craftmarkmexico.com www.craftmarksa.com www.craftmarksouthafrica.com 3212 S. Cravens Fort Worth, Texas 76119 NET 30