Universal Electric Water Level Control INSTALLATION, OPERATION & MAINTENANCE MANUAL

Similar documents
VOYAGER 570G. 744A Sprayer Control

All-Fiberglass Cooling Towers

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Oil and Coolant Circulating Heating System. Model - OCSM

Table Z. Troubleshooting Chart for Air Conditioners. Cause

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Why and How we Use Capacity Control

BERMAD Fire Protection

MAC-120HE-01 Air-Cooled Chiller

OPL BASIC. Dosing System for Professional Laundry machines. Contents

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump


BERMAD Fire Protection

Condensing unit type EPSILON-ECHOS LE Technical information manual

Fossil fuel heating equipment

G670 Intermittent Pilot Ignition Controls

! WARNING. Before using product, read and understand instructions.

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW


TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Technical Information

Please keep these operating instructions in a safe place.

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

MODEL INSTALLATION INSTRUCTIONS

Water Leak Detection System

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

TMS TANK MANAGEMENT SYSTEM

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

A99B Series Temperature Sensors

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Explosion-Proof Electric Unit Heaters

Overheating limit control

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Self Purging Liquid Trap (SPLT ) User s Manual

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

SELECTION, APPLICATION AND MAINTENANCE

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

HERZ-Thermal Actuators

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

1998½-2007 Dodge Ram 5.9L Cummins

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Operators manual Basic water heater

DKG 972 Gas Burner Safety Control

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

H41 Electrical Stage Aft Air Conditioner Unit Installation

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

SECTION MORTUARY REFRIGERATORS

Refrigeration System Installation & Operation Manual

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Technical Information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Digital inductive conductivity transmitter

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

, User s Manual

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Diesel Engine Driven Generators Page 1 of 6

Air Conditioner Water Heater Model ACWH18

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Evaluate, Clean, and Tune Guidance

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

High School Graduation years 2013, 2014, Unit/Standard Number

LOBOY 16 AIR CONDITIONERS

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Commercial Semi-Instantaneous Water Heaters

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual.

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

Electronically Controlled Clutchless or Variable Drive Compressors

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Transcription:

Universal INSTALLATION, OPERATION & MAINTENANCE MANUAL

Operation and Maintenance 1 Introduction 1 Parts Checklist 2 Installation 8 L.E.D. Status Codes Table of Contents 9 Operation and Maintenance 9 Specifications INSTALLATION, OPERATION & MAINTENANCE» UNIVERSAL ELECTRIC WATER LEVEL CONTROL

Introduction BAC s (EWLC) are state of the art, conductivity actuated, probe type liquid level controls. The hermetically sealed EWLC are engineered and manufactured specifically for use in evaporative cooling systems and are now equipped with a status code L.E.D. which illuminates to indicate status including when the water and/or probes are dirty. They have a universal mounting system designed to fit on any tower. Installation Operation and Maintenance Introduction Parts Checklist The EWLC-IM-3 is a three probe control used to maintain the proper operating level when connected to a normally closed (NC) solenoid valve. The EWLC-IM-4 control adds an additional probe for use as a low water cutout for basin heater protection, low water alarm, or high water alarm. The ELWC-IM-5 control adds a fifth probe. The two additional probes can be used for high alarm/low alarm, low alarm/heater cutout or as high alarm/heater cutout. The EWLC-IM-6 is supplied with six probes and the three additional probes are used for high alarm/low alarm/heater cutout. Parts Checklist See below for a parts checklist for the following electronic water level control models: 1. EWLC-IM-3, 3 Probe 2. EWLC-IM-4, 4 Probe 3. EWLC-IM-5, 5 Probe 4. EWLC-IM-6, 6 Probe Quantity Description 1 Stilling Chamber, 2 PVC Pipe 1 2 S x F PVC Coupling 2 Universal Mounting Bolts 2 2 U-Bolt 4 Plastic Wing Nut 1 Tank Fitting for Wiring Cable 8 Self Tapper, 5/16 x ¾ 8 Seal Washer, 5/16 8 Bolt 5/16 x 1 8 Nut, 5/16 UNC 8 Flat Washer, 5/16 8 Lock Washer, 5/16 1 Roll Sealer Tape NOTE: Parts are provided for universal installation. Not all parts will be required for installation. 1

Installation NOTE: Power wiring, disconnects, fusing, and auxiliary control wiring are by others and must comply with all applicable codes and ordinances. 1. Select a suitable mounting location in the tower. Mount near a door or access way for easy adjustment or cleaning. 2. Use mounting brackets and hardware as needed for installation. 3. Attach the stilling chamber, 2 S x F PVC Coupling, and probe assembly to the mounting bracket with 2 U-bolts and plastic wing nuts (see Typical Installation below). Do not glue any of these parts together. They are designed to be taken apart for easy, routine maintenance. 4. Set operating level. The water level set point (valve open) is 4 above the bottom of the stilling chamber. Check the unit Operation and Maintenance Manual for the proper operating level. 5. Drill a 7/8 hole in the tower casing to pass the wiring cable to the outside of the unit. Attach the water tight, through-the-wall, tank fitting. Leave adequate slack in the wiring inside the tower to allow the control assembly to be removed from the stilling chamber for cleaning. 6. Wire the control per the proper diagrams as shown on pages 3 through 7. 7. A normally closed (NC), slow closing, solenoid valve is required on the make-up line. Refer to the chart (page 9) for suggested valve sizing. These valves are available as an accessory from your local BAC Representative. 8. Hand fill the cooling tower until the water level is ½ below the overflow connection. 9. Energize the system. 10. Check the tower periodically during the first few hours of operation to ensure the control is working properly and the water level is set properly. 11. The water level may be adjusted by simply loosening the U-bolts and repositioning the control assembly. Typical Installation Wiring Cable Tank Fitting See Notes 3 & 4 NOTES: 1. Drill ¼ hole for tappers. 2. Drill 11/32 pilot for bolts. 3. Drill 7/8 hole for cable tank fitting. 4. Leave adequate slack in wiring cable to allow the control head to be lifted from the stilling chamber for inspection and cleaning. 5. Do not cut this end. The purpose of the slot at this end is to vent air. EWLC Do Not Glue Install This End At Top See Note 5 U-Bolt PVC Stilling Chamber PVC SxF Coupling Position Mounting Bracket(s) Using Hardware As Required See Notes 1 & 2 Plastic Wing Nut 1" Probes Stilling Chamber Longest Probe See Section A 4" Std. Operating (Refer to Product Specific O&M Manual) Section A 2 Side Of Unit 1" Section View

3-Probe Installation, Operation and Maintenance Installation Typical Installation 3-Probe 4-Probe, High Circuit Make-Up Circuit Solenoid Valve Power Supply 4-Probe, High Circuit High Circuit Make-up Circuit / Power Supply Solenoid Valve High H NOTE: A waterproof wire nut is provided on the end of each wire shown with an asterisk (). Do not remove these wire nuts. Do not use these wires. High () 3

4-Probe, Low Circuit / Low Circuit Make-up Circuit Low L Power Supply Solenoid Valve NOTE: A waterproof wire nut is provided on the end of each wire shown with an asterisk (). Do not remove these wire nuts. Do not use these wires. Low () 4-Probe, Cutout Disconnect Switch Circuit / Cutout Circuit Make-up Circuit Auxilliary Contact-N.C. Spray Pump (By Others See Note 6) Power Supply R Thermostat Solenoid Valve B Penn A19-ANC (By BAC-see Note 7) Y (See Table Below) Contactor L1 L2 L3 Recommended Wiring of Optional Package s Magnetic Contacts (Wire Multiple s In Parallel) Cutout () NOTE: A waterproof wire nut is provided on the end of each wire shown with an asterisk (). Do not remove these wire nuts. Do not use these wires. 4

5-Probe, High, Low Installation, Operation and Maintenance Installation / / / / Circuit Low Circuit Make-Up Circuit High Circuit Solenoid Valve Low L High H Power Supply 4-Probe, Low 4-Probe, Cutout 5-Probe, High, Low 5-Probe, Low, Cutout High () NOTE: A waterproof wire nut is provided on the end of each wire shown with an asterisk (). Do not remove these wire nuts. Do not use these wires. Low () 5-Probe, Low, Cutout Disconnect Switch Circuit Cutout Circuit Make-Up Circuit / / / / Low Circuit N.C. Pump Contacts Low L Power Supply Solenoid Valve B R Y Contactor Thermostat Penn A19-ANC (By BAC-see Note 7) (See Table Below) NOTE: A waterproof wire nut is provided on the end of each wire shown with an asterisk (). Do not remove these wire nuts. Do not use these wires. Low () Cutout () Recommended Wiring of Optional Package s Magnetic Contacts L1 L2 (Wire Multiple s In Parallel) 5 L3

5-Probe, High, Cutout Disconnect Switch Circuit Cutout Circuit Make-Up Circuit / / / / High Circuit Solenoid Valve N.C. Pump Contacts B R Y Contactor Thermostat Penn A19-ANC (By BAC-see Note 7) (See Table Below) H High Power Supply NOTE: A waterproof wire nut is provided on the end of each wire shown with an asterisk (). Do not remove these wire nuts. Do not use these wires. High () Cutout () Recommended Wiring of Optional Package s Magnetic Contacts L1 L2 L3 (Wire Multiple s In Parallel) 6

6-Probe, High, Low, Cutout Installation,Operation and Maintenance Circuit Cutout Circuit Disconnect Switch Installation 5-Probe, High, Cutout 6-Probe, High, Low, Cutout Make-Up Circuit / / / / High Circuit Low Circuit N.C. Pump Contacts Low L Power Supply Solenoid Valve B R Thermostat Penn A19-ANC (By BAC-see Note 7) Y (See Table Below) Contactor High H High () Low () Cutout () Recommended Wiring of Optional Package s Magnetic Contacts L1 L2 L3 (Wire Multiple s In Parallel) 7

Notes For All BAC Wiring Diagrams 1. Wiring and components indicated by dashed lines are to be supplied by firms other than BAC. All wiring must comply with applicable codes and ordinances. 2. The water level control board is wired in the inverse mode so that the solenoid makeup valve will close if there is a loss of power to the control board. When the water level rises to the bottom of the make-up valve off probe and maintains contact for at least 6 seconds, the control de-energizes the valve. The valve remains de-energized until the water level recedes below the bottom of the make-up valve on probe and remains at that level for at least 6 seconds. The control then energizes the valve. 3. Any incoming power source must have a 3A fuse for component protection. Using a fuse over 3A will void the BAC warranty. 4. The solenoid actuated make-up valve is rated at 6.1 watts, 16 VA holding, 30 VA inrush. 5. The normally closed solenoid valve has a slow closing feature which minimizes water hammer and is designed to operate at make-up water line pressures of 10 to 125 PSIG. To further minimize the potential for water hammer, make-up water line pressures at the higher end of the range should be avoided, and make-up piping should be well supported. 6. Interlok immersion heaters with circulating pump to de-energize heaters when pump is running. 7. thermostat is to be set for 40 F. Do not set thermostat lower than 40 F. 8. A strainer is required before the solenoid make-up valve. L.E.D. Status Codes 8 1. L.E.D. on steady: Indicates normal operation. 2. Steady one second flashing: Indicates dirty probes, reading in the capacitance mode. The unit will still operate but will give the following status code of 1 second on, 1 second off (steady 1 second flashing). This status code will continue until the probes are cleaned and the power has been reset. Note: No other status codes will be displayed until the dirty probes are cleaned. 3. Two flashes and off for 5 seconds: Indicates make-up valve ran for more than 1 hour. The unit will continue to fill, with the following status code of 1 second on, 1 second off, 1 second on and then off for 5 seconds before repeating. This status will continue until power has been reset. Possible causes: leaking tank, obstructed fill / defective valve or reduced flow rate. 4. Three flashes and off for 5 seconds: Indicates shorted probes or high conductive water. The unit will continue to operate but will give the following status code of 1 second on, 1 second off, 1 second on, 1 second off, 1 second on and then off for 5 seconds before repeating. This status will continue until the water is diluted or the short is removed from the probes and power is reset. 5. Four flashes and off for 5 seconds: Indicates black probe (P6) reads covered, but White probe (P5) does not read covered (White should also be covered because it is longer than the ). This will cause the fill solenoid valve to short cycle and lead to premature failure of the fill valve. The unit will short cycle and give the status code of 1 second on, 1 second off, 1 second on, 1 second off, 1 second on, 1 second off, 1 second on and then off for 5 seconds before repeating. The unit will continue short cycle until the condition has been corrected (clean white probe) and reset the power. 6. L.E.D. does not come on after power up or resetting power: Indicates unit inoperative.

Operation and Maintenance Make-up Solenoid Valve Selection Tower Size Nominal Tons Valve Size NPT BAC Part Number 0 150 ½ 310782 150 250 ¾ 310783 250 650 1 310784 650 1301 1½ 310785 Installation, Operation and Maintenance Installation Notes for all BAC Wiring Diagrams L.E.D. Status Codes Operation and Maintenance s Specifications The valve size is the minimum recommended size for a single cell cooling tower of the rated tonnage. Multiple cell cooling towers may require a larger size valve or multiple valves piped in parallel due to greater basin volumes. Operation and Maintenance The control/probe head is fully potted and sealed so there are no user serviceable electronic components. The only services that are required are: 1. Clean the stainless steel electrodes periodically to prevent accumulations of scale, corrosion, sludge or biological growth, which could interfere with the electrical circuit. 2. The water level is maintained at the recommended operating level regardless of the system thermal load. Therefore, it is not recommended that the operating level be adjusted. 3. During the start-up of units equipped with the electric water level control package, by-pass the control unit in order to fill the unit to the overflow connection. Specifications Enclosure Contact Rating Supply voltage Secondary Circuit Sensitivity Temperature Time Delay Probes Stilling Chamber Specifications 2 PVC Schedule 40 with Extra Long Coupling Spears 3 AMP. Resistive, +10%/-15%, 60 Hz 1V-5V, 10kHz-62kHz 26000 OHM -40 F to +150 F Ambient 6 Seconds ¼ Diameter Stainless Steel, Protected with a Plastic Sheath (except ground) 2 PVC Pipe NOTE: Recommended valve type is a slow closing, normally closed solenoid valve, designed to reduce water hammer. Mounting Universal Galvanized Bracket Assembly and Hardware 9

COOLING TOWERS CLOSED CIRCUIT COOLING TOWERS ICE THERMAL STORAGE EVAPORATIVE CONDENSERS HYBRID PRODUCTS PARTS & SERVICES w w w. B a l t i m o r e A i r c o i l. c o m 7600 Dorsey Run Road, Jessup, MD 20794 Telephone: (410) 799-6200 Fax: (410) 799-6416 2014 Baltimore Aircoil Company MEWLC/4-B