Inter-System handover test (WCDMA GSM) Model only. Software upgrade from model or model to Dual tester, (Model )

Similar documents
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

GSM Testers for Rent and Sale

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

PXI. GSM/EDGE Measurement Suite

Agilent E6832A W-CDMA Calibration Application

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

How To Use A Sound Card With A Subsonic Sound Card

R&S ZVA Vector Network Analyzer Specifications

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters

Application. Benefits. Contact us. Solution for Indoor TETRA coverage. TETRA/TETRAPOL Repeater RF/OF High Power. To ensure TETRA coverage everywhere

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

R&S ZNC Vector Network Analyzer Specifications

RADIUS. Brief brochure. Product Purpose

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

DSA800 Series Spectrum Analyzer

Product Specifications

Telephone- and leased line modem for industrial applications TD-36

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

MANUAL PC1000R

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Continuous, remote monitoring and logging of electromagnetic fields

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

HUAWEI F688 Fixed Wireless Terminal

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

LOW COST GSM MODEM. Description. Part Number

DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender

1. SAFETY INFORMATION

How To Sell A Talan

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

AXIS 262+ Network Video Recorder

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Agilent 8753ET/8753ES Network Analyzers

Rayson. Bluetooth Module

Avionics. IFR 4000 Nav/Comm Test Set

GSM Voice Auto Dialer & SMS Sender JC-999

GOOD WILL Instrument Co., Ltd. All rights reserved.

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Continuous, remote monitoring and logging of electromagnetic fields

R&S ZNBT8 Vector Network Analyzer Specifications

Unidirectional Transmitter/ Receiver Units Introduction

LT-82 Stationary IR Transmitter

Rack mounted telephone- and leased line modem for industrial applications

Agilent E5100A Network Analyzer

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

General Specifications

Frequency selective monitoring and logging of environmental electromagnetic fields

TS-770 SERIES CONFERENCE SYSTEM

Physical Specifications (Custom design available.)

USER MANUAL VS92A / VS94A / VS98A

Sympodium Interactive Pen Display

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

iva Cable & Antenna Analyzer

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

iva Cable & Antenna Analyzer

Agilent Technologies 3000 Series Oscilloscopes

User Manual. EtherUSB

WLAN Protocol Tester PTW 70

HDO700 P FIBRE OPTIC TRANSMITTER

PRImaGate Switch RACK 3U

SMART Podium Interactive Pen Display

FREJA 300 Relay Testing System

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Wi-Fi Router Huawei E5. User Guide

Voltech DC1000. Precision DC Bias Current Source

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

NC-12 Modbus Application

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Using R&S FSW for Efficient Measurements on Multi- Standard Radio Base Stations Application Note

RX-AM4SF Receiver. Pin-out. Connections

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Remarkable achievements

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

USB Smart Power Sensor

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Turbo X channel UHF true diversity

R&S ZCxxx Millimeter-Wave Converters Specifications

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

Manual Serial PCI Cards

NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS

2.4G Bluetooth Datalink & ipad Ground Station User Guide V1.02

2014 GSM SHIELD COMPATIBLE WITH ARDUINO GSM SHIELD USING SIMCOMM (SIM900A)

Terminal and Dimension

G3 Fax. SKIPPER 150 FleetBroadband (FB) Ver : 1.0

LwLVision-USB 2.0. Installation Guide

LCD Drawer User Manual

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

GSM GATEWAY PRI / E1 RACK 3U

Transcription:

Bulletin 7330-15E

Inter-System handover test (WCDMA GSM) Model 733015 only Software upgrade from model 733013 or model 733014 to Dual tester, (Model 733015) Simple operation (one button test mode) Auto Test and Manual Test TxRx tester mode for non-call processing evaluation of components(modules) Automatic data saving in HDD Printing out test result files by a external printer Language : English, Chinese, Japanese 01 02

The Auto mode provides a fast Go/No-Go test with simple operation. Everybody can judge Pass or Fail without mistakes. Simple operation in Auto mode By only pressing the START button each of the items are automatically judged according to the test script which is selected in advance. The test result files are saved to the Hard Disc Drive. Autol Mode display Easy test script editing The test script files for each mobile phone or each test condition can be stored in HDD. The test script file is edited by a Web browser. No special software is required. The test script files can be transferred to or from an external PC. Test result print Case 1 By connecting the USB printer to the VC200, the test result files in HDD can be printed. Using a network printer is also available. Case 2 Free PC software Result Viewer has the capability for printing and editing the result files. Network Capability Through Ethernet the administrator can unify management of the test result files or the test script files held on each VC200 HDD. 03

Manual Control or PC Control The Manual mode provides for more detailed test conditions. Selected test items are measured repeatedly. Each test condition can be modified during the test by mouse operation or external PC control. Stand-alone solution All test conditions can be set without a PC. Remote Control The VC200 series allows users to control every function via Ethernet interface. Users can use the VC200 series with other GPIB products. Burst timing Inner loop power control The Tx/Rx Test mode does not use a call processing sequence. This is Non-Signaling mode. The VC200 series can test RF parameters - RF signal generator - RF power measurement - EVM - Frequency error - Phase error only for GSM - Burst timing only for GSM P-SCH S-SCH P-CCPCH CPICH Downlink Uplink Circuit Module WCDMA GSM 04

The VC230 supports Inter-RAT handover. Total test time is reduced by this function. All test items are completed without a Location update. WCDMA GSM Handover The latest firmware is located on the Yokogawa Web site (www.yokogawa.com/tm). The VC200 update is done through the USB Interface. Model 733013 (GSM tester) and Model 733014 (WCDMA tester) can be upgraded to Model 733015 (GSM/WCDMA tester) for an additional charge by the option upgrade license software key. Download latest version file File Copy USB Memory Stick CD-R/ USB CD Drive USB Maximum downlink signal generation is -10 dbm Minimum uplink signal measurement is -70 dbm START key Hard disc lamp POWER lamp RF input/output connector Reference input connector USB port Clock output connector Ethernet port Power switch STOP key DISPLAY OFF key USB port Serial (RS-232) port Timing signal output connector 05

<WCDMA part> Model 733014 and 733015 W-CDMA Test Functions Call Processing Frequency Switch Maximum Output Power Measurement Minimum Output Power Measurement Open Loop Power Control Inner Loop Power Control EVM / Frequency Error Reference Sensitivity (BER) Maximum Input (BER) Sound loop back Transmission frequency Band I (2110.0 to 2170.0MHz) Band II (1930.0 to 1990.0MHz) Band III (1805.0 to 1880.0MHz) Band VI (875.0 to 885.0MHz) Transmission power Range: -110.0 to -10.0 dbm (resolution : 0.1dBm) Absolute Accuracy: ±1.5dB (> -60dBm), ±2.0dB (< -60dBm) Reception frequency Band I (1920.0 to 1980.0MHz) Band II (1850.0 to 1910.0MHz) Band III (1710.0 to 1785.0MHz) Band VI (830.0 to 840.0MHz) Reception power (Tx power measurement) Maximum input level: +35dBm Measurement range: -70 to +35dBm Absolute accuracy: ±1.5dB Frequency error measurement Range: 0 to ±10kHz Residual error: ±0.01ppm EVM measurement Residual EVM: approx 4% General specifications Display: Color LCD VGA Interface: 100BASE-TX, USB, RS-232 Language: English, Japanese, Chinese Operating ConditionsTemperature: +5 to +35 C Humidity : 20 to 80%RH Rated supply voltage100 to 120VAC / 200 to 240VAC Allowable supply voltage 48 to 63Hz frequency range Maximum power150va or less consumption External dimensionsapprox. 283(W) 176(H) 303(D) mm WeightApprox. 6.5kg <GSM part> Model 733013 and 733015 GSM Test Functions Call Processing Frequency switch Power measurement Phase and Frequency error Rx Quality Rx Level Loop back BER / FER Burst timing Sound loop back GSM Band GSM850, P-GSM, E-GSM, R-GSM, DCS1800, PCS1900 Transmission power Range: -110.0 to -10.0 dbm (resolution: 0.1dBm) Absolute accuracy: ±1.5dB (> -60dBm), ±2.0dB (< -60dBm) Reception power (Tx power measurement) Maximum input level: +40dBm(GSM Burst), +35dBm(CW) Range: -40 to +35dBm Absolute accuracy: ±1.5dB Phase error measurement Range: peak 0.5 to 45deg, rms 0.5 to 20deg Residual error: Approx 1.4deg (rms) Frequency error measurement Range: 0 to ±10kHz Residual error: ±0.02ppm Models & Suffix Code Model Suffix Code Description 733013 VC210 GSM Tester 733014 VC220 WCDMA Tester 733015 VC230 GSM/WCDMA Tester Power Code -D UL/CSA standard -F VDE standard -Q BS standard -R AS standard -H GB standard Connection -N Type N RF Connector Type -T Type TNC RF Connector Accessory Model Suffix Code Description 733065 Test USIM card -D01 For Japanese phones -E02 For UMTS 06

Shield Box Frequency : 800 to 2500MHz Shield Characteristic : < -60dB Antenna Coupler (for air connection) Frequency : 800 to 2500MHz Coupling Loss : < 20dB* Impedance : 50 Ohm Maximum Input Power : 0.25W RF Connector : Type N * Best case of antenna position RF Cable Interface (for coaxial cable connection) Frequency : 800 to 2500MHz Cable Loss : < 0.3dB ( from External connector to Internal connector) Impedance : 50 Ohm External RF Connector : Type N Internal RF Connector : SMA General Specification Operating conditions Temperature : +5 +35 C Humidity : 20 80%RH Storage conditions Temperature : -20 +60 C Humidity : 20 80%RH External dimensions : Approx. 280(W) 280(H) 117(D) mm Weigh : Approx. 2.6kg Standard accessories : N-TNC cable 0.7m Models & Optional accessories Model Description 733061 VC-SHIELD Shield Box USB Interface External USB Connector : Type B Receptacle Internal USB Connector : Type A Receptacle UE Power Interface External Power Connector : D-sub 9pin Plug Internal USB Connector : D-sub 9pin Receptacle Maximum voltage : 5V Maximum current : 2A YOKOGAWA CORPORATION OF AMERICA YOKOGAWA EUROPE B.V. YOKOGAWA MEASUREMENT TECHNOLOGIES AB YOKOGAWA MEASUREMENT TECHNOLOGIES Ltd. YOKOGAWA MEASUREMENT TECHNOLOGIES GmbH YOKOGAWA IBERIA S.A. YOKOGAWA ITALIA S.r.l. YOKOGAWA ENGINEERING ASIA PTE.LTD. YOKOGAWA SHANGHAI TRADING CO., Ltd. YOKOGAWA MEASURING INSTRUMENTS KOREA Corp Phone: (1)-301-916-0409 Fax: (1)-301-916-1498 Phone: (31)-33-4641858 Fax: (31)-33-4641859 Phone: (46)-8-477-1900 Fax: (46)-8-477-1999 Phone: (44)-1628-535830 Fax: (44)-1628-535839 Phone: (49)-81-5293-100 Fax: (49)-81-5293-1060 Phone: (34)-91-7713150 Fax: (34)-91-7713180 Phone: (39)-2-662411 Fax: (39)-2-6455702 Phone: (65)-62419933 Fax: (65)-62412606 Phone: (86)-21-6880-0303 Fax: (86)-21-6880-4987 Phone: (82)-2-551-0660 Fax: (82)-2-551-0665 Represented by : YOKOGAWA ELECTRIC CORPORATION Communication & Measurement Business Headquarters 2-9-32 Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Phone: (81)-422-52-5869, Fax: (81)-422-52-6154 E-mail: tm@csv.yokogawa.co.jp Subject to change without notice. [Ed : 01/b] Printed in Japan, 510(KP) All Rights Reserved, Copyright 2005, Yokogawa Electric Corporation.