Floodlight Motion Detector Installer's Guide. Floodlight Motion Detector PHS01

Similar documents
LED MOTION ACTIVATED FLOOD LIGHT

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

5W LED Energy Saver PIR Bulkhead

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

LED MOTION ACTIVATED FLOOD LIGHT

LED Security Spotlight User Manual

LOS 2500 SUPER CEILING SENSOR. Installation Manual

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

PIR Motion Detector INSTALLER GUIDE E-700. SF-SA-140 -B.qxd 16/05/ :19 Page 1

PIR Motion Detector INSTALLER GUIDE E-806. SF-SA-360-CS-W.qxd 12/04/ :34 Page 1

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

Your safety and the safety of others are very important.

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Die-Cast Metal, Motion- Activated Post Light

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225

60W Security Twinspot. 754HB2/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

PIR Motion Detector E-808

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Laserlyte-Flex Alignment System

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

Page 1. Description

This section gives you some helpful information and tips on running your home and the equipment in it.

Operating Instructions. Room temperature controller

GE Wireless Devices Battery Replacement

Generator Transfer Switch Model # HTS15-AUTO

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Control Box Wiring For PRSstandard Tool

Troubleshooting Guide for Dispenser Model #900172

FIRERAY 2000 Installation Guide

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Ceiling Fan Installation Instructions

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Portable Air Conditioner

Installation Instructions For Slider Casement Air Conditioners

3 IN 1 BATHROOM HEATER

Cooktop Low-Profile Ventilation Hoods

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

REDWALL-V adjustment procedures guide

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Dual Technology Ceiling Mount Sensor

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

DIGITAL WARMING CABINETS

Operating instructions IV / 2007

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

CARING FOR YOUR WATER HEATER

Your safety and the safety of others are very important.

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

Installation Instructions

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Wireless Home Security Alarm System AM 500

EBDSPIR-PRM, EBDSPIR-PRM-IP

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

INFRARED QUARTZ WALL HEATER

FOXAIR 60/50 ALL MODELS

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

24 Wide Screen LED Monitor with HDMI

Mini Timer Owner's Manual. Model MT13A

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Infrarot-Bewegungsmelder IP44

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

HERZ-Thermal Actuators

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

Operating Instructions

Wireless Indoor/ Outdoor Thermometer

SWIMMING POOL HEAT PUMP Owners Manual

Installation Instructions

RC HELICOPTER INSTRUCTION MANUAL

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

For Models #6-5001, #6-7501, # & #10-12K1

15GAL STEEL OIL DRAIN WITH 110V PUMP

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

Digi-Motor Installation Guide

Serial ATA to Serial ATA

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

INSTALLATION & OPERATING INSTRUCTIONS

16/32 Channel 1U Rack Mount CCTV Power Supply

INSTALLATION INSTRUCTION Touch Panel Switch with Occupancy Sensor

High kw Electric Tankless Water Heater Troubleshooting Guide

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Air Conditioner B B

Transcription:

Installer's Guide PHS01

Installation Locating the Motion Detector The Motion Detector mounting plate is designed to fit a standard round outdoor electrical junction box (not included). The detector should be mounted around 6-8ft above the ground in a location so that a moving object will cut across it's beams. Installation Installing the Motion Detector Poor location (movement directly toward sensor may not be detected) Consider the following points when locating the sensor: Good location (movement on any path will cross sensor beams and be detected) The Motion Detector must be at least 6-8ft above the ground and be parallel to the ground. Existing floodlights must be aimed away from the sensor. Direct sunlight must not fall on the sensor lens. The sensor must not face reflective surfaces such as a swimming pool or large windows. You must not mount the sensor over heat producing vents or air conditioning units. The sensor cannot 'see' through glass. Note: The sensor 'sees' a moving object by detecting a change in temperature. If you install and set up the Motion Detector on a very hot day, it will be difficult for the sensor to detect the difference between the heat from your body and the background temperature. (At 98.6 F you are invisible to the sensor). In very hot weather it is recommended that you make test adjustments in the evening when it is cooler. Screw the base of each lamp holder into the outer holes of the mounting plate and secure them with the locking rings. Screw the sensor head into the center hole of the mounting plate and lock it into place with the locking ring. Connect the white wire from each of the lamp holders to one of the white wires from the sensor head using one of the wire nuts provided. Connect the black wire from each of the lamp holders to the blue wire from the sensor head using one of the wire nuts provided. Install the supplied gasket on the junction box and route the house wiring through the gasket. Connect the black wire and the remaining white wire from the sensor head to the house wiring. Black to Live and White to Neutral. Do not connect the Black to a switched Live as from a wall switch. The PHS01 requires uninterrupted power at all times. Screw the motion sensor to the wall box and align the sensor head and floodlights as desired. Note: The Motion Detector has a special lens that 'looks' downwards. It must therefore be mounted to face outwards horizontally, i.e. do not 'aim' the sensor downwards. 2 3

Control Panel The control switches for the Motion Detector are located underneath the sensor head. Open the control panel cover by turning the knurled screw. Adjusting the Motion Detector Sensor Coverage Set the DUSK control fully clockwise to LIGHT. Set the RANGE control fully clockwise to MAX. Set the TIME DELAY to 0.1 minutes (approx. 6 seconds) using a flathead screwdriver. Swivel the sensor head toward the area you want to cover. Be sure the sensor head remains level from side-to-side and level with the ground. Aim the floodlights at the area you wish to light. Turn on the power and wait for one minute. Walk around the covered area. Whenever the sensor 'sees' you the floodlights come on and remain on for six seconds after you stop moving. If necessary, reorient the sensor head so normal road traffic does not activate the Motion Detector. 4 5

Dusk control The default setting for the dusk control is indicated by the index mark. This setting should be tried before making any further adjustments. The setting of the dusk control is quite sensitive, so only make small adjustments each time. Note: When you change the setting of this control, or when the light level changes, the new setting does not take effect until 10 minutes after the setting was changed or the light level changed. If movement is detected just after an adjustment was made, you will need to wait until 10 minutes after the delay time you set on the Motion Detector. Turn the control toward DARK if the Motion Detector comes on too early. Turn the control toward LIGHT if the Motion Detector comes on too late. Turn the control all the way to LIGHT to activate the Motion Detector all the time. Range control Turn towards MAX to increase range. Turn towards MIN to avoid traffic, pets or small animals triggering the Motion Detector. Time Delay switch Set to desired time for lights to stay on when no further motion has been detected. This Unit switch Set to SENSOR to have floodlights turn on when motion is detected. Set to DUSK to have floodlights turn on at dusk and off at dawn. House Code Set the House Code to match other X-10 modules which are to be controlled by the Motion Detector. Start Code This is the House Code for the Motion Detector. The Motion Detector floodlights can be switched on and off from an X-10 controller using the same House Code and Unit Code. The Start Code is also the number which is added to the slide switch numbers to set the Unit Codes for other modules controlled by the Motion Detector. Note: When the floodlights are switched on using an X-10 controller, they will stay on until they are turned off again using an X-10 controller. Sensor switches These switches determine which other modules will be switched on when motion is sensed. The number next to the switch (+1 to +4) is added to the Start Code to determine the Unit Code for a module. (For example, if the Start Code is set to 3 and the Sensor Switch labelled '2' is set to 'IN', the module with unit code 5 and the same House Code as the Motion Detector will switch on). i.e. Start code (3) plus In/Out switch (+2) = 5. Set the module inside the house (having the same House Code) to unit 5 and when motion is detected after dark, the module unit 5 will also cycle with the floodlights. Dusk switches These switches determine which other modules will be switched on at dusk and off at dawn. The number next to the switch (+5 to +8) is added to the Start Code to determine the Unit Code for a module. (For example, if the Start Code is set to 3 and the Sensor Switch labelled '6' is set to 'IN', the module with unit code 9 and the same House Code as the Motion Detector will switch on). Example: see above sample, changing values for +5 through +8. Caution: To avoid the risk of fire or injury ensure that potentially hazardous appliances such as portable heaters or fans will not be accidentally controlled by the Motion Detector. Choose controlled Unit Codes carefully. Troubleshooting Problem: The floodlights are on constantly and will not shut off. Solution: Make sure that the power supplied to the PHS01 is un-interrupted as with a wall switch. Rewire the Power to maintain constant power, then send an Off command to the PHS01 from an X-10 PRO controller, (such as the PHC01 Mini Controller), returning the PHS01 to cycling. Also, a flood light accidentaly powered off during a time delay will stay locked on. After dark, (see position of light/dark setting) trigger the sensor by a motion, after the delay time they will return to normal cycling. Problem: I want to have the lights on for a couple hours for a party, what do I do? Solution: Once again, using the X-10 PRO PHC01 Mini Controller, you can send an ON command to the PHS01 start code, and it will stay on until an Off command is sent. Problem: I have an X-10 PRO wall switch inside the house that is set to match one of the Sensor switches (+1 to +4) on the PHS01and some times it does not respond to the command sent by the PHS01. Solution: You may have crossed over the electrical phase of the breaker panel to the opposite side. Install an XPCP Passive Coupler in the breaker panel to solve this. Another possibility is the occurence of electrical noise on the power line generated by an electronic device plugged into the power of the house. An X-10 PRO XPPF Plug-in Filter will isolate the noise from the offending device. Plug the offending device into the Filter and plug the Filter into the power outlet. 6 7

8