Teaching DR/CR with Best Dose Practices

Similar documents
Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

The Exposure Index and Its Standardization

Digital radiography has become the norm in U.S.

Quality Control and Maintenance Programs

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

INTRODUCTION. A. Purpose

Best Practices in Digital Radiography

Performance testing for Precision 500D Classical R/F System

Page: 1 of 6 Page: 1 of 6

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Introduction. Digital Mammography Detector QC FFDM. What is FFDM QC and why is it. important? What to know before you start. Eric A. Berns, Ph.D.

Learning Objectives: Quality Assurance (QA) is. Quality Assurance Procedures for Digital Radiography. Alternate definition of Quality Assurance (QA)

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

Digital Breast Tomosynthesis QC Requirements

IAC Ch 41, p.1. Procedure means a stereotactically guided breast biopsy performed on a patient for diagnostic purposes.

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Comparing dose and image quality of a conventional 400 speed class film/screen system with a CR system by assessing pediatric chest examinations

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

A software tool for Quality Assurance of Computed / Digital Radiography (CR/DR) systems

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

Physics testing of image detectors

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques

Application of Digital Radiography for the Detection and Classification of Pneumoconiosis

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

ACR AAPM SIIM PRACTICE PARAMETER FOR DIGITAL RADIOGRAPHY

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Digital Mammography Update: Design and Characteristics of Current Systems

Radiation safety in dental radiography

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

Checklist for the Qualification of Digital Detector Array Systems

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

Acknowledgement. Diagnostic X-Ray Shielding. Nomenclature for Radiation Design Criteria. Shielding Design Goal (Air Kerma):

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries

Radiation safety in dental radiography

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

Diagnostic Exposure Tracking in the Medical Record

Required RS Training Info

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

THE ROYAL AUSTRALIAN AND NEW ZEALAND COLLEGE OF RADIOLOGISTS

Elements of required physical infrastructures: space, schielding, and patient flow..

Moving Forward What does this mean for the Medical Physicist and the Imaging Community?

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered

Digital radiography conquers the veterinary world

Understanding Digital Modalities: System Integration and Use

Digital radiography exposure indices: A review

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology

Bitewing Radiography B.E. DIXON. B.D.S., M.Sc., D.P.D.S.

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams

Update on ACR Digital Mammography QC Manual

I.7. SOFT TECHNIQUE STILL IN USE IN CHEST RADIOGRAPHY PROS AND CONS

Using Automatic Exposure Control in Digital Radiography

COMMUNICATING RADIATION RISKS IN PAEDIATRIC IMAGING

Quality Control of Full Field Digital Mammography Units

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

Digital Radiography Image Quality: Image Acquisition

Compliance Guidance for FLUOROSCOPIC QUALITY CONTROL

Easy Quality Control with - PTW Equipment. Code of Practice - Quality control of X-ray equipment in diagnostic radiology

QUALITY CONTROL IN DIAGNOSTIC RADIOLOGY

Dental Radiography Core Subject. Digital Radiography

Assessing Radiation Dose: How to Do It Right

Overview of Digital Detector Technology

Histograms& Light Meters HOW THEY WORK TOGETHER

A PACS-Aware DICOM Image Object

Computed Radiography: Acceptance Testing and Quality Control

Chapter 15. Creating the Digital Image. Objectives. Key Terms

Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999

X-ray Imaging Systems

The Fundamentals of MTF, Wiener Spectra, and DQE. Motivation

The Field. Radiologic technologists take x-rays and administer nonradioactive materials into patients' bloodstreams for diagnostic purposes.

Quality control tests of diagnostic radiology equipment in Hungary, and its radiation protection aspects

ADMINISTRATIVE RULES OF THE VERMONT BOARD OF RADIOLOGIC TECHNOLOGY

Recommendations for a technical quality control program for diagnostic X-ray equipment

ACR AAPM SIIM PRACTICE PARAMETER FOR DETERMINANTS OF IMAGE QUALITY IN DIGITAL MAMMOGRAPHY

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Radiation Safety Characteristics of the NOMAD Portable X-ray System

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

IAEA-TECDOC-1447 Optimization of the radiological protection of patients: Image quality and dose in mammography (coordinated research in Europe)

The Digital Dog. Exposing for raw (original published in Digital Photo Pro) Exposing for Raw

Mammography. For 35+ years, screenfilm has been the gold standard for breast cancer detection

Bergen Community College Division of Health Professions/ Radiography Program. Course Syllabus and Course of Study for Lecture

Purchasing a cardiac CT scanner: What the radiologist needs to know

Compliance Guidance for QUALITY ASSURANCE MANUAL (2 nd Edition)

Optimization of Digital Industrial Radiography (DIR) Techniques for Specific Applications: An IAEA Coordinated Research Project

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

What is a DSLR and what is a compact camera? And newer versions of DSLR are now mirrorless

Picture archiving and communication systems (PACS) and guidelines on diagnostic display devices

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

Transcription:

Teaching DR/CR with Best Dose Practices WCEC 2013 Dennis Bowman RT(R) Clinical Instructor/Staff Radiographer Community Hospital of the Monterey Peninsula (CHOMP) Cabrillo Clinical Instructor Speaker/Consultant Digital Radiography Solutions (DRS) & MTMI Discussion Topics 1. What is the new Optimum kv? 2. CR and DR Universal Technique Charts 3. DI ranges for different vendors 4. Old and new EI systems 5. How EI numbers are corrupted 6. Image Critique/ Automatic rescaling Stewart Bushong and the penguin 1

Low Flier I have 14 Low Flier s. Barry Burns the CR guru Barry Burns MS, RT(R), DABR Retired adjunct Professor of Radiologic Science, University of North Carolina School of Medicine in Chapel Hill, North Carolina, stipulates that when using CR everyone can increase 15 20 kv from film/screen techniques (except Konica which is 5 10 kv). 2

The following slides show a hand phantom exposed from 50 to 100 kv to demonstrate the minute differences visualized on an image using higher kv s with both CR and DR. CR 50 kv CR 60 kv 3

CR 70 kv CR 80 kv CR 90 kv 4

CR 100 kv DR 50 kv DR 60 kv 5

DR 70 kv DR 80 kv DR 90 kv 6

DR 100 kv These are the new digital Optimum kvs as developed by Barry Burns So what does kvp and mas do? Not what it did in the film world, that s for sure!! There is still an optimum kvp, but it now controls only subject contrast. To a huge extent, mas does not really control density/brightness any more. Density and brightness are now mainly controlled by processing algorithms. You just need enough mas or your image will have quantum noise (pixel starvation, mottle). 7

What does optimum kv mean? Optimum means the best!! Even though it s digital, you still have to stay in the optimum range, you can t start using 120 kv on everything. If you do use too much kv it will penetrate right through your patient and hit the IR because of incorrect attenuation. This will cause the image to be over penetrated, (saturated) causing a permanent loss in contrast. Or if too little mas is used it may cause mottle. Film/Screen Technique Chart Size of the Patient The techniques are of a small, medium and large male Small = 120 160 lbs. Medium = 160 200 lbs. Large = 200 240 lbs. Females would be approximately 10 lbs. lighter. 8

Film/Screen Technique Chart How can there be a Universal CR/DR technique chart? As we all well know, this would have been impossible in the film/screen processor days. All modern generators (25 years or newer) are high frequency, so if the tubes are in calibration they should all be shooting the same. Since the CR/DR manufacturers set their systems up to have the perfect Dose Exposure Indicator # appear when 1 mr hits the plate, then any given technique will work with all the vendors if the x ray tubes are all shooting the same. Universal CR Technique Chart & The Konica Chart (both) using the Most mas 9

Page 2 Universal CR Technique Chart & The Konica Chart (both) using the Most mas Universal CR Technique Chart Lowest mas Universal CR Technique Chart Lowest mas (Page 2) 10

Differences between the Lowest Dose, 33% More, 66% More and Most Dose technique charts For example: the 33% More chart uses 33% more mas than the Lowest Dose chart. This means that the Most Dose chart uses twice the mas (so twice the dose) of the Lowest Dose chart. So start with the Most Dose chart and then if possible go down to the 66% More chart. Speaking of How Low We Can Go Here is the CESIUM DR UNIVERSAL TECHNIQUE CHART. Page 2 of the CESIUM DR UNIVERSAL TECHNIQUE CHART. 11

Here is the GADOLINIUM DR UNIVERSAL TECHNIQUE CHART. Page 2 of the GADOLINIUM DR UNIVERSAL TECHNIQUE CHART. CR versus DR We discovered that most CR techniques used twice the mas of Cesium detectors. Gadolinium detectors need 25 50% more radiation over Cesium detectors to make a similar exposure. 12

This is the proof of how much dose you save your patient when you increase the kv and decrease the mas and/or decrease the EI #. How Low Can You Go? This is how I now teach ALARA. With the new optimum kvp s already in place, it s figuring out how low can you take the mas and get an image with no, or acceptable, mottle. I m hoping that everyone will make it a competition or goal to see what is the minimum dose they can use for any given view. Differences Between Digital And Film The concept of Agfa s 2.0 2.3 LgM range, Fuji s 400 100 S range, GE s (DR).2.6 (or.8 2.4) range and Siemens 200 900 range. Even with the range you should always be shooting for the best number in that range (which means the lowest dose). Lead shields and metal in the body will dramatically affect the EI number. If you are not able to use at least 33% of the IR you will probably have a corrupted EI number. 13

The new standards have 3 important definitions Exposure Index (EI) measure of the radiation in the region of interest (ROI) which may vary depending on manufacturer. Target Exposure Index (TEI) is the exposure index number when an image is optimally exposed. This will be determined by each facility depending on body part, view, procedure, image receptor and radiologist. Deviation Index (DI) quantifies how much the EI varies from the TEI. Standardized Exposure Index and Deviation Index International Electrotechnical Commission (IEC) 62494 1 published standards in 2008. American Association of Physicists in Medicine Task Group (AAPM TG) 116 issued report in 2009. 41 Deviation Index (DI) Repeat Underexposed Overexposed Excessive 3 2 1 0 +1 +2 +3 Deviation Index (DI) 20% 20% 20% +25% +25% +25% Perfect Exposure Toshiba Leading Innovation>>>> Here is what this system would look like with mas 3 2 1 0 +1 +2 +3 20% 20% 20% Perfect +25% +25% +25% repeat underexposed Perfect Overexposed Excessive 3 2 1 0 +1 +2 +3 15 mas 18.5 mas 24 mas 30 mas 38 mas 48 mas 60 mas 14

Here is the 4 color system I want to set up and what it looks like with mas. How to Fix an Incorrect mas for repeats Centering and the Dose Exposure Numbers These EI numbers are easily corrupted (but only up to 75% in most cases). The following slides show the elbow, chest and shoulder phantoms and how a change in centering and or collimation can affect (corrupt) the dose exposure number. 15

Perfect centering 4 sided collimation LgM 1.81 Kitty Corner touching at both corners LgM 1.81 0% change Long side touching edge LgM 1.85 13.3% change 16

Centered top side touching LgM 1.85 13.3% change Seimens portable detector in bucky Perfectly centered and collimated to 14 x14 125 kvp @ 2.7 mas EXI 356 Perfectly centered, no collimation 125 kvp @ 2.7 mas EXI 351 2.8% change 17

Centered 1 high 125 kvp @ 2.7 mas EXI 399 12.1% change Centered 2 Low 125 kvp @ 2.7 mas EXI 442 24.2% change Centered 1 low 125 kvp @ 2.7 mas EXI 313 24.2% change 18

Shoulder phantom with 3 sheets of Polyethylene to make it the thickness of a large adult male. These experiments will show the difference in EXI numbers when the collimation is left more and more open. GE built in detector (DEI range.42 1.27) 8 x8 DEI.60 0.0% change GE built in detector 9 x9 DEI.66 10.0% change 19

GE built in detector 10 x10 DEI.71 18.3% change GE built in detector 11 x11 DEI.80 33.3% change GE built in detector 12 x12 DEI.89 48.3 % change 20

GE built in detector 13 x13 DEI.96 60.0 % change To summarize the previous 16 corrupted dose exposure number slides. With all the examples, the technique always stayed the same. It was just the centering or collimation changes that corrupted the EI number. Even though the dose exposure number (EXI, S, LgM, DEI) has been corrupted up to 75%, the image is still perfectly passable in any facility. If your EI number is above 75% over what is considered perfect, this means you over exposed. Ways to Critique a Digital (DR or CR) Image You must use the EI numbers. You definitely need to use the magnification mode to check for noise and burn. You should always be able to Level and Window and make your image look well penetrated and contrasty. 21

Problems with critiquing digital images It is impossible to prove you used the ideal technique if all you are using is the finished image contrast and density as a gauge. Witness the awesome power of Automatic Rescaling Fuji 85 kvp @ 4 mas S# 357 22

85 kvp @ 8 mas S# 171 85 kvp @ 32 mas S# 38 85 kvp @ 200 mas S# 6 23

85 kvp @ 400 mas S# 3 85 kvp @ 500 mas S# 4 GE built in detector (.36 1.07) 85 kv @ 2 mas DEI.96 24

85 kv @ 4 mas DEI 1.97 85 kv @ 8 mas DEI 4.0 85 kv @ 16 mas DEI 7.72 25

85 kv @ 32 mas DEI 14.67 85 kv @ 64 mas DEI 27.41 Grid cut off with grid suppression software. Is usually very difficult to see. 26

No Angle 40 99 kv @ 63 mas Angled up 5 degrees Angled up 10 degrees Horizontal and short axis grids with a 10 degree caudad angle. The horizontal grid had a smaller LgM number, is brighter (lighter) and has less contrast. LgM 2.03 LgM 2.10 Siemens equipment with Canon detector. Grid landscape, tube parallel with floor. 117 kv @2.8 mas EXI 334 27

Grid landscape, tube angled 10 degrees to floor. 117 kv @2.8 mas EXI 205 Grid portrait, tube angled 10 degrees to floor. 117 kv @2.8 mas EXI 331 GE portable. Grid with handle up, tube parallel with floor. 120 kv @2 mas DEI.65 28

Grid with handle up, tube angled 10 degrees to floor. 120 kv @2 mas DEI.54 Grid with handle to the side, tube angled 10 degrees to floor. 120 kv @2 mas DEI.66 Post processing collimation (shuttering) for CR. Courtesy of Becky Daley, TCC 29

Agfa/Fuji/Carestream EI Comparisons Konica/Shimadsu/SwissRay EI Comparisons Radiographic Image Analysis by Kathy McQuillen Martensen Third Edition 30

Digital Radiography Solutions Specializing in Educational Conferences and Seminars Dennis Bowman Website: digitalradiographysolutions.com Email: drs@redshift.com Phone: 831 601 9860 31