INSTRUCTIONS FOR EMS 550X SPUTTER COATING DEVICE

Similar documents
Balzers Sputter Coater SCD 050

VCR Ion Beam Sputter Coater

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

Measurement of Specific Heat Capacity Using Differential Scanning Calorimeter

BAL-TEC SCD 005. Scientist in charge: Lhoussaine Belkoura 07/14/06. softcomp soft matter composites 1

K550X Sputter Coater Instruction Manual

Boiler Preparation, Start-Up and Shutdown

Quick Guide to Floor Grinding

Installation Instructions S

Troubleshooting Guide for Jacks Down LED Lights

Disposable Insulin Delivery Device User Manual

SunMor SM-V30 Solar Water Heater Installation Manual

Ion Beam Sputtering: Practical Applications to Electron Microscopy

San josé OWNER S MANUAL

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

K500X Manual Sputter Coater Instruction Manual

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

Standard Operating Procedure

PA 9117 FSAMP. Lilly. Prefilled Insulin Delivery Device User Manual

Front brakes (FN- 3), servicing

Lab 3 - DC Circuits and Ohm s Law

Model 43AP Pneumatic Controller, Style B

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

K575X Sputter Coater Instruction Manual

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Installation Instructions

Nexus FS Point of Use Installation Guide

Lab Activity on Air Pressure, Wind and Air Circulation Caused by Heating of the Atmosphere

The Krasnogorsk-3. Operating Instructions. Sold by NCS Products, New York

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

Magnetic Deburring & Polishing Machine

SC 7000 and SC 9000XL Patient Monitors SC 9000XL Monitor 12in (30.5cm) Display Service Manual Supplement Two

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

MAINTENANCE & TROUBLESHOOTING

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Written By: Walter Galan

Operator: Save these instructions for future use!

HUMULIN 70/30 KwikPen

5CHAPTER. Setting Up the Polling Place. IMPORTANT: The electronic poll book MUST be set up first and you MUST begin the update by 5:15 am.

Super Cool Sputter Coater

Vacuum Tube Solar Water heater Non-pressure. User manual

FLOWMETER INSTALLATION INSTRUCTIONS

Instructions for Use. Components of the GENOTROPIN PEN 12

Diesel Fuel Systems. Injection Nozzles

In addition to information on preventing jams and what causes a paper jam, this section includes instructions for clearing the following jams:

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

Belt Sander. Given a properly adjusted belt sander, accessories, instruction and demonstration of use, each student will be able to:

Name: Due: September 21 st Physics 7230 Laboratory 3: High Resolution SEM Imaging

ACCUMULATOR INSTALLATION

INSTALLATION AND SERVICE MANUAL

Wooden Shipping Crate is Available to Protect Your UV Light Source. 11 X " diameter tubes 120 VAC Amps Watts

5800 Temperature Sensor Cable Assembly

National- Spencer Inc.

B/S/H/ Error codes and service programmes PH

WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential Control Panels

SC, FC and ST * Hot Melt Fiber Optic Connectors

1R / 4-BUTTON SERIES

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Digital Photo Picture Frame. Operation Manual

GENUINE PARTS INSTALLATION INSTRUCTIONS

WINDOW ROOM AIR CONDITIONER

Installation Instructions

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Vacuum drying oven for non-flammable solvents

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

A Remote Plasma Sputter Process for High Rate Web Coating of Low Temperature Plastic Film with High Quality Thin Film Metals and Insulators

The Basics of Scanning Electron Microscopy

Recharge Procedure for Telemark TVP-2000 and TVP-3500

HEAT PUMP PROGRAMMABLE THERMOSTAT

Sport Ice Elektro 124

PHOTOSYNTHESIS AND RESPIRATION

Equipment Manual. for. Operation of Automatic Polishing Plate Control on the PM5 Precision Lapping & Polishing Machine.

Operating Manual Color Changing Fountains

DUBOX TM LOOSE PIECE HAND TOOL

UV100A Ultraviolet Air Treatment System

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

Your safety and the safety of others are very important.

TrūShine Gel Enamel FAQs

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

SHOT BLAST CABINET MODEL NO: CSB20B

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

Operator Quick Guide EC SENSOR

INSTALLATION INSTRUCTIONS

COMMON LABORATORY APPARATUS

not appearance. ADHESIVE SYSTEMS CORIAN As an integral part of its sheet and shape products, DuPont has developed a special adhesive.

PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790

REMOTE TRANSMITTER LAYOUT

KEYPAD LOCK RETROFIT KIT

The RIDZ 8x2 Audio Switcher

SLP 1.85 Ratio Offset Rocker Arms with Valve Springs, LS3

Ceramic Glass Electric Galley Ranges

Cooling system components, removing and installing

Transcription:

INSTRUCTIONS FOR EMS 550X SPUTTER COATING DEVICE I. SPECIMEN PREPARATION A. Dry specimen. This can be done by either air drying, with HMDS, or by critical point drying. B. Mount sample onto a specimen support stub: 1. The most common type of stub is composed of aluminum. If you intend to do elemental x-ray micro-analysis (or EDS) on your specimen you might consider using a carbon/graphite stub instead. 2. In most cases, the use of double-stick carbon tape is sufficient. If another solventbased adhesive is used (e.g. nail polish, silver colloidal paint, etc), allow it to dry out thoroughly before sputter coating. 3. Pre-pump any large porous or gaseous samples in another vacuum chamber ahead of time to reduce the length of pumping time required on these types of specimens. II. SPUTTER COATER OPERATION A. Place specimen/support stub into the chamber: 1. Gently raise the sputtering head and carefully remove the glass chamber. 2. Place your specimen/support stub(s) into one of the holes on the holder. 3. Carefully replace the glass chamber making sure it is seated properly on the lower side of the chamber. 4. With two hands, carefully close the top sputtering head. Again, make sure the sputtering head is seated properly onto the glass chamber. B. Switch power ON with switch located on right rear of instrument. The STOP button and the L.E.D display window should be illuminated. Appearance of display window at this step: Press ENTER to change parameters Press START to run when ready Settings: 25mA, 00:02:00 H:M:S C. OPEN the argon tank using the main tank valve only. DO NOT adjust the regulator setting. D. Press the STOP button. This will purge the chamber with argon gas for 30 seconds as indicated on the display window shown below: Bleeding Gas into Chamber Time Remaining 00:00:30 H:M:S Vacuum : 2x10-1 mbar Page -1-

E. When the display has returned to the initial layout (see display in step II B), press the START button. Watch the vacuum reading. Vacuum values should decrease. If they do not, check the glass chamber seal for leaks or simply apply gentle pressure to the sputtering head to help seat it properly on to the glass chamber. F. With the Pump Hold feature enabled, the instrument will pump to 1 x 10-1 mbar (bleed point) as normal, then the Pump Hold feature will activate. Pump Hold time is set for 10 minutes. The display should look like this: Pump Holding, Press a key to continue Time Remaining 00:10:00 H:M:S Vacuum : 1x10-1 mbar G. Allow the vacuum reading to drop to 7x10-2 mbar and then push the Enter button to override any remaining pump hold time. Should the enter button not be pushed, the sputter coating cycle will begin after the pump hold time has expired. H. After pushing the enter button or after the pump hold time has expired, argon gas will bleed in to the chamber causing a slight increase in the vacuum reading. After approx. 15 seconds, the sputter coating process will begin and a violet plasma should be visible inside the chamber. The vacuum reading should show 1 or 2 x 10-1 mbar. If necessary, you may need to adjust the needle valve at the left rear of the instrument to achieve a stable vacuum of 1 or 2 x 10-1 mbar. Appearance of display window at this step: Coating Sample at 25 milliamps Vacuum Current Time Remaining 1x10-1 mbar 25 ma 00:01:38 H:M:S I. Allow the sputter coating process to finish. After sputter coating, the chamber will vent automatically to atmosphere with argon. Venting will take 30 seconds to complete. J. Remove specimen support stubs: 1. After chamber reaches atmosphere, gently lift sputtering head off of glass chamber and remove the glass chamber. 2. Remove your stub(s) with the SEM forceps. DO NOT use your fingers. 3. Carefully replace the glass chamber making sure it is seated properly on the lower side of the chamber. 4. With two hands, carefully close the top sputtering head. Again, make sure the sputtering head is seated properly onto the glass chamber. K. CLOSE argon main tank valve. L. Turn sputter coater OFF. M. Be Sure to Record Your Sputter Coating Time in the Log Book. Page -2-

III. ADDITIONAL INFORMATION A. To Check or Modify Parameters 1. From the main display menu (see display in step II B) press ENTER to select the change parameters menu. The screen below should appear in the window: UP and DOWN key to ALTER ENTER to accept, STOP to return Variable Name Current Value 2. For most parameters, the value is shown along with the variable name. Us the UP and DOWN arrow keys to change the values as required. When the desired value is shown in the window, press the ENTER key to accept that selection. To exit from the parameter editing menu, press the STOP key. B. Setting Operating Parameters 1. There are a number of user programmable options that can be altered by the front panel keys. When these parameters are modified, they will be save and in force the next time that the instrument is turned on. Parameter Allowable Value Description of Parameter Coating Current 0-50 ma in 5 ma steps Plasma current, default value is 25 ma Coating Time 0-4 min in 1 second steps Time of coating, default value is 2 min. FTM Enabled yes or no Film Thickness Monitor, default is NO FTM Type external or internal default is External FTM Mode automatic or manual default is Automatic Material gold or other default is Gold, density = 19.32g/cm 3 FTM Terminate default is 005.nm FTM Tool Factor default is 1.0 Pump Hold Enabled Yes / No Extra pumping time is enabled or disabled. Default setting is YES Pump Hold Time 0-8 hr in 5 sec steps 00:00:00 H:M:S Set amount of extra pumping time, default time is 00:10:00 (10 minutes) Stage Rotate Enabled Yes / No Rotate stage during coating, default setting is YES C. Pump Hold Feature 1. The Pump Hold feature is used for one of two reasons: a. If it required to outgas a specimen more than would be possible during the normal automatic cycle, then select Pump Hold Enabled in the parameter menu. This will prevent the cycle from continuing until either a key is pressed or the stored Pump Hold Time elapses, whereby the cycle will continue in the normal Page -3-

manner. The vacuum should eventually achieve better than 7 x 10-2 mbar. b. If it is required to use the EMS 250 Carbon Coating Attachment (see Instructions for EMS 250 Carbon Coating Attachment). If this is the case, then select Pump Hold Enabled and select a fairly long Pump Hold Time, perhaps longer than 30 minutes. The EMS 550X is now used as a vacuum chamber for the carbon evaporation head. 2. When Pump Hold is enabled, the instrument will pump to 1 x 10-1 mbar (bleed trip point) as normal, then the Pump Hold feature becomes active. The display should look like this: Pump Holding, Press a key to continue Time Remaining 00:04:36 H:M:S Vacuum : 8x10-2 mbar 3. The Pump Hold time has a default value of 10 minutes but it can be programmed for up to 8 hours. As stated above, the instrument will continue pumping until either the time elapses or a key is pressed. The cycle will continue as normal. Page -4-

INSTRUCTIONS FOR USING THE EMS 250 CARBON COATING ATTACHMENT I. SPECIMEN PREPARATION A. Dry specimen. This can be done by either air drying, with HMDS, or by critical point drying B. Mount sample onto a specimen support stub: 1. The most common type of stub is composed of aluminum. If you intend to do elemental x-ray micro-analysis (or EDS) on your specimen you might consider using a carbon/graphite stub instead. 2. In most cases, the use of double-stick carbon tape is sufficient. If another solventbased adhesive is used (e.g. carbon colloidal paint), allow it to dry out thoroughly before coating. 3. Pre-pump any large porous or gaseous samples in another vacuum chamber ahead of time to reduce the length of pumping time required on these types of specimens. II. COATER OPERATION A. Place specimen/support stub into the chamber: 1. Gently raise the sputtering head and carefully remove the glass chamber. 2. Place your specimen/support stub(s) into one of the holes on the holder. 3. Carefully replace the glass chamber making sure it is seated properly on the lower side of the chamber. 4. DO NOT close the top sputtering head. For carbon coating, leave sputtering head open or in the upright position. B. Load carbon in to carbon coating head: 1. Unit is stored behind sputter coater under a large plastic beaker. 2. Stand carbon head on sputter coater while loading. Rubber feet should be down right now. 3. Carefully load a small section of braided carbon rope in to electrodes and trim off excess with scissors. 4. Carefully invert carbon coater and place on top of glass vacuum chamber. Rubber feet should now be pointing upward. C. Switch power ON with rocker switches located on right rear of BOTH units. The STOP button and the L.E.D display window should be illuminated on the EMS 550X unit (left-hand unit) and the 12V ac light and the 12V dc light should be lit on the EMS 250 unit (right-hand unit). Appearance of 550X display window at this step: Press ENTER to change parameters Press START to run when ready Settings: 25mA, 00:02:00 H:M:S Page -5-

D. OPEN the argon tank using the main tank valve only. DO NOT adjust the regulator setting. E. If you want the stage to rotate during carbon coating, make sure the coating time on the 550X display window reads 6 minutes or more. If you don t want the stage to rotate, leave the coating time at 2 minutes and then make sure the Pump Hold feature is enabled and is set for at least 15 minutes. See the Section III: Additional Information if you need help locating or changing these settings. F. Press the START button. Watch the vacuum reading. Vacuum values should decrease. If they do not, check the glass chamber seal for leaks or simply apply gentle pressure to the sputtering head to help seat it properly on to the glass chamber. G. At a vacuum reading of 1 x 10-1 mbar, outgas the carbon rope by doing the following: 1. Rotate heat shield over your sample (if desired) 2. Push the Outgas button 3. Slowly turn the Outgas Current Knob clockwise until the rope begins to glow a good orange color and hold for approximately 60 seconds. Keep watching the rope while you are doing this. You will need to make constant adjustments to the current knob during this 60 seconds in order to maintain this orange glow. Otherwise, it tends to get brighter over time. Reduce the current knob if necessary. While you are doing this, the vacuum reading will go up (e.g. maybe 3 or 4 x 10-1 mbar). 4. After ~60 seconds, turn Outgas Current Knob down and push the Outgas Button again to disengage. 5. Remove the heat shield from your sample while the system continues to pump down. H. At 7 x 10-2 mbar evaporate the carbon rope. For quick evaporation, do step 1. For slow and controlled evaporation, complete steps 2 through 6. 1. For quick evaporation, push and hold the Evaporate Button until bright glow stops. 2. For slow evaporation, first push the Outgas Button 3. Slowly increase current with the Outgas Current Knob until the rope is bright white (~35-40 Amps). The goal here is to keep it as bright as possible with minimal amount of sparking. If the carbon rope begins to spark, reduce current slightly but try to maintain a bright carbon source at all times. 4. Hold at this level for as long as possible (~15 seconds to 1 min). After this, increase the current to the maximum to finish off the rope. 5. Once the rope is finished, reduce the current to zero with the Outgas Current Knob. 6. Push the Outgas Button again to disengage. I. Push the STOP button twice and allow the chamber to vent. Venting will take 30 seconds to complete. J. Remove specimen support stubs: 1. After chamber reaches atmosphere, gently lift carbon coating head off of glass chamber and stand coating head rubber feet down on to sputter coater unit. 2. Carefully remove glass chamber. 3. Remove your stub(s) with the SEM forceps. DO NOT use your fingers. 4. Carefully replace the glass chamber making sure it is seated properly on the lower Page -6-

side of the chamber. 5. With two hands, carefully close the top sputtering head. Again, make sure the sputtering head is seated properly onto the glass chamber. 6. Clean up coating head by removing any unused carbon rope from electrodes and brushing off any carbon debris. CAUTION: ELECTRODES MAY BE HOT!! 7. Place carbon coating head back behind sputter coater and cover unit with large beaker K. If you made changes to the sputter coating time in the beginning, please reset this to 2 min. L. CLOSE argon main tank valve. M. Turn OFF both sputter coating units. N. Be Sure to Record Your Sputter Coating Time in the Log Book. III. ADDITIONAL INFORMATION A. To Check or Modify Parameters 1. From the main display menu (see display in step II B) press ENTER to select the change parameters menu. The screen below should appear in the window: UP and DOWN key to ALTER ENTER to accept, STOP to return Variable Name Current Value 2. For most parameters, the value is shown along with the variable name. Us the UP and DOWN arrow keys to change the values as required. When the desired value is shown in the window, press the ENTER key to accept that selection. To exit from the parameter editing menu, press the STOP key. B. Setting Operating Parameters 1. There are a number of user programmable options that can be altered by the front panel keys. When these parameters are modified, they will be save and in force the next time that the instrument is turned on. Parameter Allowable Value Description of Parameter Coating Current 0-50 ma in 5 ma steps Plasma current, default value is 25 ma Coating Time 0-4 min in 1 second steps Time of coating, default value is 2 min. FTM Enabled yes or no Film Thickness Monitor, default is NO FTM Type external or internal default is External FTM Mode automatic or manual default is Automatic Page -7-

Material gold or other default is Gold, density = 19.32g/cm 3 FTM Terminate default is 005.nm FTM Tool Factor default is 1.0 Pump Hold Enabled Yes / No Extra pumping time is enabled or disabled. Default setting is YES Pump Hold Time 0-8 hr in 5 sec steps 00:00:00 H:M:S Set amount of extra pumping time, default time is 00:10:00 (10 minutes) Stage Rotate Enabled Yes / No Rotate stage during coating, default setting is YES C. Pump Hold Feature 1. The Pump Hold feature is used for one of two reasons: a. If it required to outgas a specimen more than would be possible during the normal automatic cycle, then select Pump Hold Enabled in the parameter menu. This will prevent the cycle from continuing until either a key is pressed or the stored Pump Hold Time elapses, whereby the cycle will continue in the normal manner. The vacuum should eventually achieve better than 7 x 10-2 mbar. b. If it is required to use the EMS 250 Carbon Coating Attachment (see Instructions for EMS 250 Carbon Coating Attachment). If this is the case, then select Pump Hold Enabled and select a fairly long Pump Hold Time, perhaps longer than 30 minutes. The EMS 550X is now used as a vacuum chamber for the carbon evaporation head. 2. When Pump Hold is enabled, the instrument will pump to 1 x 10-1 mbar (bleed trip point) as normal, then the Pump Hold feature becomes active. The display should look like this: Pump Holding, Press a key to continue Time Remaining 00:04:36 H:M:S Vacuum : 8x10-2 mbar 3. The Pump Hold time has a default value of 10 minutes but it can be programmed for up to 8 hours. As stated above, the instrument will continue pumping until either the time elapses or a key is pressed. The cycle will continue as normal. Page -8-