Reducing Radiation Dose by Using Pulse X-Ray Apparatus

Similar documents
Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered

Radiation Safety Characteristics of the NOMAD Portable X-ray System

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

Submitted to Radiation Measurements INVESTIGATION OF OSL SIGNAL OF RESISTORS FROM MOBILE PHONES FOR ACCIDENTAL DOSIMETRY

I.7. SOFT TECHNIQUE STILL IN USE IN CHEST RADIOGRAPHY PROS AND CONS

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

The photoionization detector (PID) utilizes ultraviolet

Calculating particle properties of a wave

7üVNORD. TÜV NORD Röntgentechnik

Portuguese Health Physics Society: Calibrating Pen Dosimeters with and without a Phantom

Introduction to Geiger Counters

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

X Ray Flourescence (XRF)

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

Ionizing Radiation, Czech Republic, CMI (Czech Metrology Institute)

USE OF IONIZING RADIATION IN THE TEACHING OF PHYSICS AND CHEMISTRY

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Atomic and Nuclear Physics Laboratory (Physics 4780)

Radiation safety in dental radiography

Manual for simulation of EB processing. Software ModeRTL

Introduction. Chapter 15 Radiation Protection. Regulatory bodies. Dose Equivalent. Regulatory bodies. Main Principles of Radiation Protection

DOSES TO EYES AND EXTREMITIES OF MEDICAL STAFF DURING INTERVENTIONAL RADIOLOGY PROCEDURES

Radiation Detection and Measurement

PERSONNEL MONITORING AND DOSIMETRY POLICIES

Development and Experimental Performance Evaluation of a Dose-Rate meter for Pulsed Beam.

Production of X-rays and Interactions of X-rays with Matter

Lectures about XRF (X-Ray Fluorescence)

Chemistry 1000 Lecture 2: Nuclear reactions and radiation. Marc R. Roussel

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

X-RAY FLUORESCENCE SPECTROSCOPY IN PLASTICS RECYCLING

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes

GAMMA-RAY SPECTRA REFERENCES

Vacuum Evaporation Recap

Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study

X-ray (Radiography) - Bone

X-ray Imaging Systems

Cyclotron Centre in Poland and 2D thermoluminescence dosimetry

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

Electricity. Investigating spontaneous gas discharge in air as a function of pressure. LD Physics Leaflets P Sel

Describing Sound Waves. Period. Frequency. Parameters used to completely characterize a sound wave. Chapter 3. Period Frequency Amplitude Power

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

Irradiation Field Size: 5cmX5cm 10cmX10cm 15cmX15cm 20cmX20cm. Focus-Surface Distance: 100cm. 20cm Volume of Ion Chamber : 1cmX1cmX1cm

ACCELERATORS AND MEDICAL PHYSICS 2

Radiation Strip Thickness Measurement Systems

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

Fundamentals of Cone-Beam CT Imaging

Raman Scattering Theory David W. Hahn Department of Mechanical and Aerospace Engineering University of Florida

X-ray Imaging Systems

INTENSIFYING SCREENS, CASSETTES AND SCREEN FILMS N. Serman & S. Singer

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

Symmetric Stretch: allows molecule to move through space

DOSIMETRIC CHARACTERIZATION OF DYED PMMA SOLID DOSIMETERS FOR GAMMA RADIATION

The Challenge of CT Dose Records

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

COLLATED QUESTIONS: ELECTROMAGNETIC RADIATION

EDXRF of Used Automotive Catalytic Converters

Sample Exercise 6.1 Concepts of Wavelength and Frequency

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

C1 Medical Imaging Modalities & Characteristics Linwei Wang

Reduction of Electron Contamination Using a Filter for 6MV Photon Beam

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

World-first Proton Pencil Beam Scanning System with FDA Clearance

General requirements. 1. Administrative Controls.

Selection, use and maintenance of portable monitoring instruments

X-ray (Radiography), Chest

Chemistry 102 Summary June 24 th. Properties of Light

Cutting Edge Digital Radiography Technology in Daily NDT Use

Qualitätsmanagement-Handbuch

Infrared Spectroscopy: Theory

The University of Southern Maine. XRF X-Ray Radiation Protection Program

6/2016 E&M forces-1/8 ELECTRIC AND MAGNETIC FORCES. PURPOSE: To study the deflection of a beam of electrons by electric and magnetic fields.

Quality control tests of diagnostic radiology equipment in Hungary, and its radiation protection aspects

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SOURCES AND EFFECTS OF IONIZING RADIATION

Using the Bruker Tracer III-SD Handheld X-Ray Fluorescence Spectrometer using PC Software for Data Collection

1. Orthovoltage vs. megavoltage x-rays. (AL) External beam radiation sources: Orthovoltage radiotherapy: kv range

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

RADIATION SAFETY STANDARD

Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

DETERMINATION OF THE EFFECTIVE VOLUME OF AN EXTRAPOLATION CHAMBER FOR X-RAY DOSIMETRY

How To Understand Light And Color

Nuclear Magnetic Resonance

Coating Thickness and Composition Analysis by Micro-EDXRF

Ultrasound Dose Calculations

Physics testing of image detectors

Exploring the Properties of the TV Monitor and Remote Control

X-ray (Radiography) - Chest

Gamma and X-Ray Detection

Upon completion of this lab, the student will be able to:

Transcription:

Journal of Biosciences and Medicines, 2014, 2, 17-21 Published Online April 2014 in SciRes. http://www.scirp.org/journal/jbm http://dx.doi.org/10.4236/jbm.2014.22003 Reducing Radiation Dose by Using Pulse X-Ray Apparatus A. A. Komarskiy 1,2, A. S. Chepusov 1,2, V. L. Kuznetsov 1, S. R. Korzhenevskiy 1, S. P. Niculin 1,2, S. O. Cholakh 2 1 Pulsed Radiation Sources Laboratory, The Institute of Electrophysics of the Ural Division of the Russian Academy of Science, Ekaterinburg, Russian Federation 2 Institute of Physics and Technology, Ural Federal University (Named after First President of Russia B.N. Yeltsin), Ekaterinburg, Russian Federation Email: aakomarskiy@gmail.com Received December 2013 Abstract Pulse X-ray diagnostics is capable of reducing the radiation exposure considerably. As for pulse X-ray diagnostic machines, which form pulses with the duration of 0.1 µs, using them one can get outstanding results in this area. This fact can be explained by the long period of luminophor persistence in intensifying X-ray luminescent screens. In this paper we present experimental data, comparing radiation doses, measured at pulse X-ray apparatus and apparatus of constant radiation. Keywords X-Radiation; Pulse X-Ray Tube; Pulse X-Ray Diagnostic; Ionizing Radiation 1. Introduction Medical radiation makes up a major portion of the radiation dose for population of the Earth. As for the Russian Federation this type of radiation takes the second place after natural sources of ionizing radiation in the total radiation doze. 98% of the radiation is taken by diagnostic and prophylactic X-ray examinations. Pulse X-ray diagnostics is capable of reducing the radiation exposure considerably. Generating X-ray radiation as a sequence of short X-ray flashes instead of continuous radiation is a distinguishing feature of this method. The pulse X-ray tube (pulse duration 5-20 ms, frequency 2-12 pulses per second), which is used during endoscopic diagnostic and therapeutic interventions of bile ducts, was described in paper [1]. The shorter the pulse and the less the frequency the less the radiation exposure of the patient and the personnel, but the quality of the images reduces accordingly. As for pulse X-ray diagnostic machines, which form pulses with the durations of 0.1 µs, the principle of reducing the absorbed dose is completely different. 2. Experiment In medical diagnostics intensifying X-ray luminescent screens are obligatory. Since X-ray film, which most How to cite this paper: Komarskiy, A.A., et al. (2014) Reducing Radiation Dose by Using Pulse X-Ray Apparatus. Journal of Biosciences and Medicines, 2, 17-21. http://dx.doi.org/10.4236/jbm.2014.22003

commonly used to absorbed radiation has coefficient of X-ray radiation 0.01, as for intensifying screens Gd2O2S:Tb the coefficient is 0.29 [2]. Luminophors, which are used in the intensifying screens, have a certain period of persistence [3]. To define the duration of persistence precisely timing data and fluorescence intensity of luminophors, used in diagnostics, Kodak lanex, EU-G3, EU-G300, EU-I4, were measured. Measuring was performed at a pulsed cathodoluminescence spectrometer. In Figure 1, you can see an oscillogram, picturing the process of luminophor persistence EU-G3, typical for all the group of intensifying screens under investigation. The persistence duration of level 2.7 is 500 µs when pulse duration is 0.1 µs. The final results as persistence duration of the intensifying screens of level 0.1 are given in Figure 2. Measuring amplitude-time characteristics of persistence show, that all luminophors under investigation are characterized by the persistence at level of a millisecond, which is by an order of magnitude greater than radiation pulse duration of a nanosecond X-ray unit, as shown in Figure 3. X-ray quanta irradiate luminophor the X-ray photo detector luminophor with the intensity I r, and the luminophor radiation intensity is T I () t = I e (1) l 0 τ Figure 1. The persistence X-ray intensifying screen EU-G3. Persistence duration, µs 1600 1400 1200 1000 800 600 400 200 0 Kodak Lanex EU-G300 EU-G3 EU-I4 Figure 2. Persistence duration of the intensifying screens of level 0,1. 18

Figure 3. An oscillogram of voltage and current of the X-ray tube RIA1-120. Voltage amplitude 110 kv, current amplitude 450 А, scale 10 ns/ point, repetition rate 850 Hz. where I l (t) is the radiation intensity at the time t, τ is the average time during which the excited state of luminophor atoms or molecules persists, T is period, I 0 is radiation intensity at the time when excitation of luminescence stops I0 (0.2 0.01) Ir (2) when using a constant X-radiation source, luminophor generates light radiation with the intensity I 0 and a persistence fall after X-ray exposure in е times within (1 1.5)*10 3 (s) during the whole time of exposure from hundreds of milliseconds and higher. At pulse radiation after X-ray pulse exposure luminophor persistence corresponds to е times during the same time, but this process repeats after each pulse. In the result of X-ray film accumulating light sum of the X-radiation, converted by luminophor, after X-ray pulse stops, the great difference in duration of the X-ray pulse and the luminophor persistence fall makes it possible to reduce the exposure dose. At the Institute of Electrophysics of the Ural Division of the Russian Academy of Science we invented the pulse X-ray diagnostic portable apparatus 01 (XDPA 01) [4], which was based on the described effect. Then we upgraded the X-ray apparatus and created the pulse X-ray diagnostic portable apparatus Yasen-01 [5] [6]. We performed dosimetric tests, comparing the pulse X-ray diagnostic portable apparatus Yasen-01 (maximum voltage is 110 kv, the tube s current is 150 A, pulse duration is 30 ns, repetition rate is 5 khz) with the X-ray diagnostic apparatus Siemens Axiom Iconos R200 (maximum voltage is 125 kv), using a direct current tube. Measuring dosimetric parameters was carried out with the help of the dosimeter PTW UNIDOS 10001 with 30 cm 3 cylindrical ionization chamber of 23361 kinds. Several standard modes of the tested machines for medical diagnostics of different body organs were chosen. The main criterion for the comparison was the diagnostic quality of the X-ray photographs, as shown in Figure 4. Water phantom was used behind the ionization chamber to imitate a human body (as a scattered radiation source). Phantom thickness was 20 cm, focal distance to the ionization chamber was 80 cm. The results of investigations are shown in Table 1. Then we performed tests, comparing the pulse X-ray apparatus Yasen-01 with the X-ray portable diagnostic apparatus Definium AMX 700 (maximum voltage is 105 kv) and with stationary X-ray complex Evolution HV which was created by STEPHANIX (maximum voltage is 40-150 kv). We compared the following parameters: effective doses, the quality of the X-ray images and usability. Calculating the effective doses of patients was made using the results of measuring radiation output of the apparatus with the help of the following measuring devices: the wide-range device for dosimetry of continuous and pulse X-rays and gamma rays DKS-AT1123, the all-mode dosimeter for controlling characteristics of X-ray apparatus-unfors Xi RF&MAM detector. In Table 2, effective doses of patient irradiation are presented. Three proficient roentgenologists carried out independent estimation of the X-ray images quality and the apparatus usability. 19

(a) Figure 3. Elbow arthrogram using by a) X-ray diagnostic apparatus with direct current tube; b) pulse X-ray diagnostic portable apparatus Yasen-01. Table 1. Test results of Siemens Axiom Iconos R200 and Yasen-01. (b) Object, projection Siemens Axiom Iconos R200 Yasen-01 Voltage, kv Exposition, mas Dose, µgy Voltage, kv Exposition, mas Dose, µgy Lungs, direct 57 3.6 200 110 1.4 70 Skull, side 60 8 505 110 3.7 185 Thigh, direct 55 8 410 110 3.4 170 Knee, direct 47 6.3 215 100 1.8 86 Ankle, direct 48 4.5 160 100 1.0 48 Table 2. Effective doses of patient irradiation. Name Projection Effective dose, msv Yasen-01 Chest (direct) 0.027 Definium AMX 700 Chest (direct) 0.570 Evolution HV Chest (direct) 0.721 3. Discussion As follows from the Table 1, the radiation dose of Yasen-01 is 2.5-3 times lower than the one of Siemens Axiom Iconos R200 and 20-25 times lower compared with Definium AMX 700, Evolution HV. The fact is that with the help of the pulse X-ray we can decrease the dose more significantly can be explained by the higher value of anode current (Yasen-01 150 A), since luminophor radiation intensity I l is proportional to X-ray quantum intensity I r hence it proportional to the X-ray tube current I e. Moreover, decreasing dose is explained by pulse duration: the Yasen-01 apparatus generates X-ray pulses of shorter duration (30 ns). Therefore the Yasen-01 apparatus has a more homogeneous radiation spectrum and greater effective energy (42.5 kev), i.e. it 20

creates harder radiation. The X-ray tube s performance in good conditions in terms of maximum acceptable heat load of the anode should be considered as one of the machines advantages. At present the operating mode of constant radiation machines is limited to 0.3-0.01 A. This limitation is subject to maximum acceptable heat load of the anode, since exceeding this value causes anode destruction. However the pulse tube current reaches the peak value of 150 А, which increases luminescence intensity I l by dozens of times. For example, if repetition rate is f = 1 khz and pulse durations is τ = 10 8 s, duty factor Q = equals Q = 10 5, and the tube average current < I > (when current pulse is I e = 100 А) is inversely proportional to pulse duty factor, 1 f τ (3) I e < I >= (4) Q and equals just < I > = 1 10 3 А. The chest X-Ray direct projection images, which were obtained at the pulse X-ray diagnostic portable apparatus Yasen-01, are the same as to the quality of the images, which were obtained by the X-ray portable diagnostic apparatus Definium AMX 700 and are insignificantly inferior compared with the images obtained by the stationary X-ray complex Evolution HV which was created by STEPHANIX. Roentgenologist point out that thanks to the compact size and low weight (about 45 kg) the Yasen-01 apparatus can be used in confined space and is easily transported. 4. Conclusions In conclusion, the conducted investigation demonstrates that X-ray radiation dose is decreased by several times thanks to using pulsed nanosecond X-ray machines as opposed to using relative conventional X-ray units. The dose of radiation was reduced so significantly thanks to the fact that persistence duration of X-ray radiation converters (luminophor) is several times higher than X-ray pulse duration. Further decreasing radiation dose is possible owing to increasing current pulse amplitude I e, shortening pulse duration τ and increasing duty factor Q. The quality of the X-Ray images which were obtained at the pulse X-ray diagnostic portable apparatus Yasen-01 is the same as at constant X-radiation apparatus. Thanks to its small size and weight Yasen-01 apparatus can be used in confined space and easily transported in narrow corridors and elevators. References [1] Doroshko, M. V. (1998) New Capabilities in Reducing of Radiation Dose лучевой нагрузки. News of Radiodiagnostics, 3, 13-15. [2] Blinov, N.N., Bikov, R.E. and Kozlovskiy, E.B. (1989) Engineering Tools of Medical Introscopy. Leonov B.I., Moskow. [3] Kazgikin, O.N., Markovskiy, L.Y., Mironov, I.A., Pskerman, F.M. and Petoshina, L.N. (1975) Inorganic Phosphor. Leningrad. [4] Filatov, A.L., Korzhenevskiy, S.R., Kuznetsov, V.L., Ananin, M.V. and Motovilov, V.A. (2004) The Nanosecond PP X-ray Apparatus. Procedings of the 15th International Conference on High-Power Particle Beams, Saint-Petersburg, 1-7 April 2004, 552-554. [5] Filatov, A.L., Bastrikov, V.L., Korzhenevskiy, S.R., Kuznetsov, V.L. and Ponikaravskih, A.E. (2007) Universal Portable X-Ray Apparatus. Russian Federation Patent No. 2005503167. [6] Mozharova I.E. and Kuznetsov V.L. (2011) The Pulse X-Ray Diagnostic Portable Apparatus Yasen 01. Medical business, 9, 84-85. 21