Transfer switch OTEC and OTECSE open transition

Similar documents
GTEC transfer switch open transition

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

Transfer switch BTPC open, closed or delayed transition

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Diesel generator set C22D5T series

ASCO SERIES 185 Power Transfer Switches

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

PowerCommand Paralleling System Digital MasterControl

Transfer Equipment Controls

Zenith Controls ISO R-1000C 5/99

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Bypass transfer switch mechanisms

Diesel Engine Driven Generators Page 1 of 6

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Continuous Power... Continuous Protection

CTS SERIES AUTOMATIC TRANSFER SWITCH

PowerCommand 3201 digital generator set control

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Grounding of AC generators and switching the neutral in emergency and standby power systems

Automatic transfer switches. International. Reliable, flexible and dependable

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

SECTION VARIABLE FREQUENCY DRIVES

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

Series TS Amp. Automatic Transfer Switches

Spark-ignited generator set

SUGGESTED SPECIFICATION for Service Entrance Automatic Transfer Switches

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Guidelines for ATS selection: How to choose the right transfer solution for your power application.

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

AUTOMATIC TRANSFER SWITCHES

SECTION LOW VOLTAGE LIGHTING CONTROLS

PowerCommand iwatch 100

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

ELECTRICAL: AUTOMATIC TRANSFER SWITCHES

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Gas Genset Controls. Genset Control Panel (GCP2) with PCS (PowerCommand Supervisor) Features. Description

Power Supplies 3. SDN-P DIN Rail Series

8146/5 Series Breaker Panelboards

Thyristor-controlled power supplies and battery chargers

OUTPUT CABLE CONNECTIONS:

PowerCommand 1.1 control system

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

MCC Ratings. Voltage Rating

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

Catalog January. Heavy industrial power applications Motor contactors and starters

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Owner's Manual. Automatic Transfer Switch. This manual should remain with the unit.

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Solid State Timers Type F

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Unified requirements for systems with voltages above 1 kv up to 15 kv

ADDENDUM #1(BID PACKAGE # 3)

FIREDEX Conventional Fire Panels

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Circuit Breakers. Next Generation of Protection Capabilities

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Sentron Series Circuit Breakers

Terminal Blocks & Power Distribution Terminal Blocks. Make your connection

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

PowerCommand iwatch 100 Remote Network Monitoring

POWER GENERATION.

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

How To Test A Power Switch On A Power Supply

User Manual for CH-PFC76810

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS

SURGE PROTECTIVE DEVICES

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

ELECTRICAL SAFETY RISK ASSESSMENT

32VFD Variable Frequency Drives for Centrifugal Chillers

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

ATC-300 Automatic Transfer Switch Controller

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Transcription:

Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They are suitable for use in emergency, legally required, and optional standby applications. The es monitor both power sources, signal generator set startup, automatically transfer power, and return the load to the primary power source once a stable utility is available. The fully integrated controller is designed for practical functionality, with LED indicators and digital pushbuttons for ease of operator use. The service entrance transfer meets UL 1008 standards for service entrance applications. The contains an UL-listed overcurrent disconnect device on the main incoming utility source. All es are UL 1008 Listed with UL Type Rated cabinets and UL Listed CU-AL terminals. NEC All es are certified to CSA 282 Emergency Electrical Power Supply for Buildings, up to 600 VAC. Equipment shall be suitable for use in systems compliant to 700, 701 and 702. All es comply with NFPA 70, 99 and 110. All es comply with NEMA ICS 10. All es comply with IEEE 446 Recommended Practice for Emergency and Standby Power Systems. This transfer is designed and manufactured in facilities certified to ISO9001. Features Microprocessor control - Easy-to-use, standard control. LEDs display transfer status; pushbuttons allow operator to activate control test, exercise timing and transfer mode. Overcurrent disconnect device (on SE models) Square D UL-Listed 489 molded case circuit breaker. Programmed transition Open transition timing can be adjusted to completely disconnect the load from both sources for a programmed time period, as recommended by NEMA MG-1 for transfer of inductive loads. Advanced transfer mechanism - Unique bi-directional linear actuator provides virtually frictionfree, constant force, straight-line transfer action during automatic operation. Manual operation - Manual operating handles, shielded termination, and over-center contact mechanisms allow effective manual operation under de-energized conditions. Positive interlocking - Mechanical and electrical interlocking prevent source-to-source connection through the power or control wiring. Main contacts - Heavy-duty silver alloy contacts with multi-leaf arc chutes are rated for 100% load interruption. They require no routine contact maintenance and provide 100% continuous current ratings. Easy service/access - Single-plug harness connection and compatible terminal markings simplify servicing. Access space is ample. Door-mounted controls are field-programmable; no tool is required. Complete product line - Cummins Power Generation offers a wide range of equipment, accessories and services to suit virtually any backup power application. Warranty and service - Products are backed by a comprehensive warranty and a worldwide network of distributors with factory-trained service technicians.

mechanism mechanism is electrically operated and mechanically held in the Source 1 and Source 2 positions. The transfer incorporates electrical and mechanical interlocks to prevent inadvertent interconnection of the sources. Independent break-before-make action is used for 3-pole es. This design allows control of the operating speed of the transfer for proper transfer of motor and rectifier-based loads (programmed transition feature). Electrical interlocks prevent simultaneous closing signals to normal and emergency contacts and interconnection of normal and emergency sources through the control wiring. High pressure silver alloy contacts resist burning and pitting. Separate arcing surfaces further protect the main contacts. Contact wear is reduced by multiple leaf arc chutes that cool and quench the arcs. Barriers separate the phases to prevent interphase flashover. A transparent protective cover allows visual inspection while inhibiting inadvertent contact with energized components. Switch mechanism, including contact assemblies, is third-party certified to verify suitability for applications requiring high endurance ing capability for the life of the transfer. Withstand and closing ratings are validated using the same set of contacts, further demonstrating the robust nature of the design. Specifications Arc interruption Neutral bar Auxiliary contacts Operating temperature Storage temperature Humidity Altitude Total transfer time (source-to-source) Manual operation handles Multiple leaf arc chutes cool and quench the arcs. Barriers prevent interphase flashover. A full current-rated neutral bar with lugs is standard on enclosed 3-pole transfer es. Two contacts (one for each source) are provided for customer use. Wired to terminal block for easy access. Rated at 10A continuous and 250 VAC maximum. -22 of (-30 oc) to 140 of (60 oc) -40 F (-40 C) to 140 F (60 C) Up to 95% relative, non-condensing Up to 10,000 ft (3,000 m) without derating Will not exceed 6 cycles at 60 Hz with normal voltage applied to the actuator and without delayed transition enabled. es are equipped with permanently attached operating handles and quick-break, quick-make contact mechanisms suitable for manual operation under de-energized conditions. Open transition/programmed Controls the time required for the device to from source to source, so that the load-generated voltages decay to a safe level before connecting to an energized source. Recommended by NEMA MG-1 to prevent nuisance tripping breakers and load damage. Adjustable 0-60 seconds, default 0 seconds. Open transition/in-phase Initiates open transition transfer when in-phase monitor senses both sources are in phase. Operates in a break-before-make sequence. Includes ability to enable programmed transition as a backup. If sources are not in phase within 120 seconds, the system will transfer using programmed transition.

Microprocessor control Simple, easy-to-use control provides transfer information and operator controls LED lamps for source availability and source connected indication, exercise mode, and test mode. LED status lamps also provided for control set-up and configuration. Pushbutton controls for initiating test, overriding time delays and setting exercise time. Field-configurable for in-phase open or programmed open transition. Integral exerciser clock Control is prototype-tested to withstand voltage surges per EN 60947-6-1. Gold-flashed generator start contacts Control functions Voltage sensing: All phases on the normal source and single phase on generator source. Normal Source Pickup: adjustable 90-95%, Dropout: adjustable 70-90% of nominal voltage; Generator Source Pickup: 90%, dropout: 75% of nominal voltage. Frequency sensing: Generator Source Pickup: 90% of nominal frequency; Dropout: 75% of nominal frequency. Exerciser clock: Switch is furnished with an integral engine exerciser configurable for operation on a 7, 14, 21, or 28-day cycle with a fixed exercise period duration of 20 minutes. A 12-hr exerciser time offset allows for the convenient setting of exercise time without the need to activate the timer at the exact time that you need to schedule the generator exercise for. Software selectable capability allows for the exercising of the generator with or without load. Time delay functions Engine start: Prevents nuisance genset starts due to momentary power system variation or loss. Adjustable: 0-10 seconds; default: 3 seconds. normal to emergency: Allows genset to stabilize before application of load. Prevents power interruption if normal source variation or loss is momentary. Allows staggered transfer of loads in multiple transfer systems. Adjustable 0-300 seconds, default 5 seconds. Retransfer emergency to normal: Allows the utility to stabilize before retransfer of load. Prevents needless power interruption if return of normal source is momentary. Allows staggered transfer of loads in multiple transfer systems. Adjustable 0-30 minutes, default 10 minutes. Genset stop: Maintains availability of the genset for immediate reconnection in the event that the normal source fails shortly after transfer. Allows gradual genset cool down by running unloaded. Adjustable 0-30 minutes, default 10 minutes. Delayed (programmed) transition: Controls the speed of operation of the transfer power contacts to allow load generated voltages from inductive devices to decay prior to connecting a live source. Adjustable 0-10 seconds, default 0 seconds. Options Available through Accessories specification sheet AC-170.

UL withstand and closing ratings The transfer es listed below must be protected by circuit breakers or fuses. Referenced drawings include detailed listings of specific breakers or fuse types that must be used with the respective transfer es. Consult with your distributor/dealer to obtain the necessary drawings. Withstand and Closing Ratings (WCR) are stated in symmetrical RMS s. MCCB protection Special circuit breaker protection WCR at volts max with specific manufacturers MCCBs Max MCCB rating Drawing reference With specific current limiting breakers (CLB) Max CLB rating Drawing reference 125 14,000 at 600 V 225 A 098-6885 200,000 @ 600 V 225 A 098-6918 225 30,000 at 600 V 400 A 098-6886 200,000 @ 600 V 400 A 098-6919 400, 600 65,000 at 600 V 1200 A 098-6887 200,000 @ 600 V 1200 A 098-6920 Fuse protection WCR at volts max. with current limiting fuses Max fuse, size and type Drawing reference 125 200,000 at 600 V 200 A Class, J, RK1, RK5, T 098-6885 225 200,000 at 600 V 1200 A Class L or T, or 600 A class J, RK1, RK5 098-6886 400, 600 200,000 at 600 V 1200 A Class L or T, or 600 A Class, J, RK1, RK5 098-6887 Enclosures The transfer and control are wall-mounted in a key-locking enclosure. Wire bend space complies with 2011 NEC. Dimensions transfer in UL type 1 enclosure 125 27.0 686 20.5 521 12.0 305 31.5 800 82 37 0310-0544 225 35.5 902 26.0 660 16.0 406 41.0 1042 165 75 0310-0414 400, 600 54.0 1372 25.5 648 18.0 457 42.0 1067 225 102 0310-1307 Dimensions transfer in UL type 3R enclosure Cabinet Outline type drawing 125 34.0 864 26.5 673 12.5 318 36.5 927 125 57 3R 0310-0453 225 42.5 1080 30.5 775 16.0 406 44.0 1118 215 97 3R 0310-0454 3R 0310-1315 400, 600 59.0 1499 27.5 699 16.5 419 41.5 1054 275 125 4 0310-1316 Dimensions for SE models transfer in UL type 1 enclosure 40, 70, 100, 45.8 1164 32.0 814 16.3 413.0 45.9 1165 300 136 0500-4721 125 150, 200, 225, 73.6 1869 32.3 820 19.7 499.0 49.6 1259 500 227 0500-4606 250 300, 400, 600 74.5 1892 34.4 873 20.1 510.4 50.9 1293 520 236 0500-4611 Dimensions for SE models transfer in UL type 3R or 12 enclosure 40, 70, 100, 45.8 1164 32.0 814 16.3 413.0 45.9 1165 340 154 0500-4721 125 150, 200, 225, 73.6 1869 32.3 820 19.7 499.0 49.6 1259 580 263 0500-4606 250 300, 400, 600 74.5 1892 34.4 873 20.1 510.4 50.9 1293 600 272 0500-4611

lug capacities All lugs accept copper or aluminum wire unless indicated otherwise. Cables per phase Size 125 1 #12 AWG-2/0 225 1 #6 AWG 300 MCM 400 1 3/0 600 MCM 400 2 3/0-250 MCM 600 2 250-500 MCM Submittal detail Amperage ratings 125 225 400 600 Voltage ratings R021 208 R023 240 R026 480 Pole configuration A028 Poles - 3 (solid neutral) Frequency A044 60 Hertz Application A035 Utility to genset System options A041 Single phase, 2-wire or 3-wire A042 Three phase, 3-wire or 4-wire Enclosure B002 Type 3R: intended for outdoor use, provides some protection from dirt, rain and snow (IEC Type IP34) Standards A046 UL 1008/CSA certification Control voltage M033 12V, Genset starting voltage M034 24V, Genset starting voltage Warranty G009 1 year comprehensive Accessories AC-170 Accessories specifications sheet (control options, battery chargers, aux relays, terminal blocks, guards) North America 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 2013 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand, AmpSentry, InPower and Our energy working for you. are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice. S-1639b (6/13)