SMA Medium Voltage Power Platforms Medium Voltage Transformers - 4-Winding Design

Similar documents
Sunny Boy Accessories SMA POWER BALANCER

Multi-tap Transformers

S. C. Electric Cooperative s Specification for a Three-Phase, Padmounted URD Transformer (Revised 12/2014)

Technical Information Requirement for MV transformers and transformer for internal power supplies for SUNNY CENTRAL

Distribution Transformers

Medium Voltage Electrical Distribution

SECTION SUBSTATION TRANSFORMERS

Step Voltage Regulators

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Secondary Unit Substations

Medium-voltage Transformers

This section applies to the design and installation of transformers.

TRANSFORMER DICTIONARY

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Primary and Secondary Electrical Distribution Systems

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

WINDING RESISTANCE TESTING

Distribution Voltage Regulators

Table of Contents. TransformerIQ FAQs 1

Instructions for Secondary Unit Substation Transformers KVA, Three Phase

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Diesel Engine Driven Generators Page 1 of 6

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Technical Specification for Oil insulated Transformers U m < 24 kv up to 1250 kva

Unified requirements for systems with voltages above 1 kv up to 15 kv

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

Presentation of the France Transfo factories

Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS)

Transformer Design & Design Parameters

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

16300 MEDIUM VOLTAGE DISTRIBUTION

SECTION VARIABLE FREQUENCY DRIVES

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Data Center Solutions. Envirotran HDC Transformers Deliver Superior Reliability and Efficiency for Substantial Savings Everyday

Lightning Arresters P KVA P KVA. Description & Installation

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

Explosion-Proof Electric Unit Heaters

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Mini Power-Zone Unit Substation

Heat Tracing is the use of an externally applied heat source to a pipeline to compensate for heat losses through the thermal insulation.

Customer Substation Manual 08/05/02

Sample - No Commercial Use

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

SECTION DRY-TYPE TRANSFORMERS

Fronius IG Plus. The next generation grid-connected PV inverter

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

Power Plant Electrical Distribution Systems

SECTION ELECTRICAL ACCEPTANCE TESTS

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications

Distribution Dry Type Transformers

Short Circuit Current Calculations

600 Volt Class Transformers

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

SPECIFICATIONS OF STATCOM TRANSFORMER (FOR 2.5 MVAR STATCOM)

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Specifying a Variable Frequency Drive s

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

CAS 36 Ring Main Unit

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

ADDENDUM #1(BID PACKAGE # 3)

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Power transformers. Special transformers Railway

Low Voltage Transformers Sealed, General Purpose, Dry Type

INTERNATIONAL STANDARD

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

TERMINATION ENCLOSURE OPTIONS

MCC Ratings. Voltage Rating

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

, User s Manual

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Hyperlinks are Inactive

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Thyristor-controlled power supplies and battery chargers

Liquid Filled Transformers Load Tap Changing Transformers Three-Phase Voltage Regulators

Evaluating Water-Damaged Electrical Equipment

HL Series - Commercial Heaters Tankless Water Heating Solutions

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Transcription:

SMA Medium Voltage Power Platforms Medium Voltage Transformers - 4-Winding Design Technical Description SC_MVPP_4w_Trafo-TD-en-10 Version 1.0 CA US

Legal Restrictions SMA America, LLC Copyright 2012 SMA America, LLC. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photographic, magnetic or otherwise, without the prior written permission of SMA America, LLC. Neither SMA America, LLC nor SMA Solar Technology Canada Inc. makes no representations, express or implied, with respect to this documentation or any of the equipment and/or software it may describe, including (with no limitation) any implied warranties of utility, merchantability, or fitness for any particular purpose. All such warranties are expressly disclaimed. Neither SMA America, LLC nor its distributors or dealers nor SMA Solar Technology Canada Inc. nor its distributors or dealers shall be liable for any indirect, incidental, or consequential damages under any circumstances. (The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exclusion may not apply.) Specifications are subject to change without notice. Every attempt has been made to make this document complete, accurate and up-to-date. Readers are cautioned, however, that SMA America, LLC and SMA Solar Technology Canada Inc. reserve the right to make changes without notice and shall not be responsible for any damages, including indirect, incidental or consequential damages, caused by reliance on the material presented, including, but not limited to, omissions, typographical errors, arithmetical errors or listing errors in the content material. All trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by SMA America, LLC and SMA Solar Technology Canada Inc. is under license. SMA America, LLC 3801 N. Havana Street Denver, CO 80239 U.S.A. SMA Solar Technology Canada Inc. 2425 Matheson Blvd 8th Floor Mississauga, ON L4W 5K5 Canada 2 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC Table of Contents Table of Contents 1 Scope and Summary... 5 1.1 General... 5 1.2 Summary of Design... 5 1.3 Power Classes and Option Codes... 6 1.3.1 Options Descriptions...7 1.3.2 Example Option Code...8 2 Compliance... 9 2.1 List of Standards... 9 3 Mechanical Design... 11 3.1 General Construction... 11 3.1.1 Components of the MV Transformer... 11 3.2 Accessories... 12 3.2.1 Gages and Alarm Contacts... 12 3.2.2 LV Fuse Block... 13 3.2.3 Sampler Valve... 13 3.2.4 Medium Voltage Switch... 13 3.2.5 Grounding... 13 3.3 Mechanical Properties... 14 4 Routine Testing... 15 Technical Description SC_MVPP_4w_Trafo-TD-en-10 3

Table of Contents SMA America, LLC 5 Electrical Data... 16 5.1 General Design... 16 5.2 Datasheet of 1MVA Transformer using SC500HE-US Inverters... 17 5.3 Datasheet of 1MVA Transformer using SC500CP-10 / SC500CP-US Inverters... 19 5.4 Datasheet of 1.26 MVA Transformer using SC630CP-10 / SC630CP-US Inverters... 21 5.5 Datasheet of 1.5 MVA Transformer using SC720CP-10 / SC720CP-US / SC760CP-10 / SC750CP-US Inverters... 23 5.6 Datasheet of 1.6 MVA Transformer using SC800CP-10 / SC800CP-US Inverters... 25 6 Contact... 27 4 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC 1 Scope and Summary 1 Scope and Summary 1.1 General This document serves as the general Technical Desription for the Medium Voltage step-up Transformers (henceforth MVT) integrated in SMA s Medium Voltage Power Platforms. 1.2 Summary of Design The MVTs described herein are of a padmount design, using a four-winding, double story construction, providing galvanic isolation between the inverter ourput circuits, as shown below. They are constructed with two individual low voltage windings, and two medium voltage windings, with the medium voltage windings paralled to the output bushings. For reference only, Dy1y1 vector group shown with 5 position tap changer SMA has established a configurable product, harmonized to the Medium Voltage Power Platform product portfolio. The MVTs are designed for a minimum service life of 25 years, and are suitable for outdoor applications. Technical Description SC_MVPP_4w_Trafo-TD-en-10 5

1 Scope and Summary SMA America, LLC 1.3 Power Classes and Option Codes A unique SMA Material Number represents the MVT power class, and inverter application, which mirrors the Medium Voltage Power Platform product portfolio. SMA Material Number TR-1000HE-US TR-1000CP-10 TR-1260CP-10 TR-1500CP-10 TR-1600CP-10 Power Class / Inverter Type 1000kVA / SC500HE-US 1000kVA / SC500CP-10, SC500CP-US 1260kVA / SC630CP-10, SC630CP-US 1500kVA / SC720CP-10, SC720CP-US, SC760CP-10, SC750CP-US 1600kVA / SC800CP-10, SC800CP-US Furthermore, the parameters of the transformers are defined by selection of Option Codes, summarized as follows. Option Name Option Description Option Identifier Design Spare option Fuse protection aux. power Protection Dy1y1, 12.47kV, 4-winder A no 0 no (External MVPP Control Power) 0 Temperature 0 Dy1y1, 13.8kV, 4-winder B 80 A (Internal MVPP Control Power) 1 Temp. Pressure Fluid Level 1 Dy1y1, 20.6kV, 4-winder C Dy1y1, 24.9kV, 4-winder D Dy1y1, 27.6kV, 4-winder E Dy1y1, 34.5kV, 4-winder F 6 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC 1 Scope and Summary Option Name: Describes the option category, further defined by the Option Description Option Description: Explains the option identified by the Option Identifier Option Identifier: Defines which option is selected 1.3.1 Options Descriptions Design: Describes the MVT vector group, medium voltage level, and winding design Spare: Not used Fuse Protection Aux Power: Identifies if the MVT includes the fuse block providing overcurrent protection to the Medium Voltage Power Platform s low voltage auxiliary services. Protection: Identifies if the MVT includes a temperature gage and alarm contacts only, or if it includes gages and alarm contacts for Temperature, Pressure, and Liquid Level. Technical Description SC_MVPP_4w_Trafo-TD-en-10 7

1 Scope and Summary SMA America, LLC 1.3.2 Example Option Code Transformer Material Number: Transformer Option Code: TR-1500CP-10 A 0 1 1 Explanation: TR-1500CP-10 A 1500 kva power class, for use with SC720CP-10, SC720CP-US, SC760CP10, or SC750CP-US inverters. Delta Primary Windings, Wye Secondary Windings, 30 phase angle, Primary voltage of 12.47 kv 0 Not used. 1 Fuse block with 80A fuses included; auxiliary services suppied by PV generated power 1 Gages and Alarm contacts included for Temperature, Pressure, and Liquid Level 8 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC 2 Compliance 2 Compliance 2.1 List of Standards The MVTs are compliant to the following Norms and Standards. Standard Revision Description NEMA TR 1-1993 1993 (R2000) Transformers, Regulators and Reactors ANSI C57.12.00 2010 IEEE Standard for Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers ANSI C57.12.34 2004 Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers (2,500 kva and smaller) - High-Voltage: 34500 GrdY/19920 Volts and Below; Low-Voltage: 480 Volts and Below ANSI C57.12.28 2005 IEEE Standard for Pad-Mounted Equipment-Enclosure Integrity ANSI C57.12.70 2000 (R2006) Standard for Terminal Markings and Connections for Distribution and Power Transformers ANSI C57.12.80 2002 Standard for Terminology for Power and Distribution Transformers ANSI C57.12.90 2006 Test Code for liquid-immersed distribution, power, and regulating transformers ANSI C57.12.91 2006 Guide for Loading Mineral-Oil-Immersed Transformers ANSI C57.12.29 American National Standard Pad-Mounted Equipment - Enclosure Integrity ANSI C37.47 2008 Design Tests for High Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fused Disconnect Switches, and Accessories ANSI/IEEE 386 2006 Standard for separable insulated connector systems for Power Distribution Systems above 600 V UL XPLH - Classification of compliance to ANSI standards UL EOUV - Certification category for Dielectric Mediums UL EOVK - Certification category for Transformer Fluids ASTM A666 2003 Standard Specification for annealed or cold worked austenitic stainless steel sheet, strip, plate, and flat bar Technical Description SC_MVPP_4w_Trafo-TD-en-10 9

2 Compliance SMA America, LLC ASTM D877 - Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids using Disk Electrodes ASTM D924 - Standard Test Method for Dissipation Factor (or Power Factor) and Relative Permittivity (Dielectric Constant) of Electrical Insulating Liquids ASTM D92 - Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester ASTM D6871-03 - Standard Specification for Natural (Vegetable Oil) Ester Fluids Used in Electrical Apparatus OECD 203 - OECD GUIDELINE FOR TESTING OF CHEMICALS - Fish, Acute Toxicity Test OECD 420 - OECD GUIDELINE FOR TESTING OF CHEMICALS - Acute Oral Toxicity Fixed Dose Procedure 10 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC 3 Mechanical Design 3 Mechanical Design 3.1 General Construction The Medium Voltage Transformers are of a pad mount design, with enclosure integrity in accordance to ANSI C57.12.28. The High Voltage and Low Voltage compartments are side by side, and separated by a steel barrier. The HV compartment is on the left side, and the LV compartment to its right. 3.1.1 Components of the MV Transformer (Example; specific components and locations can vary depending upon the ordered configuration) Technical Description SC_MVPP_4w_Trafo-TD-en-10 11

3 Mechanical Design SMA America, LLC Item Description 1 Primary (MV) Bushings 2 Secondary (LV) Bushings 3 Fuse Holders / Fusess, oil immersed expulsion (for MV<23kV) 4 Medium Voltage Load Break Switch 5 Liquid Level Gage and Alarm Contacts 6 Pressure Relief Valve 7 Vaccuum Switch with Alarm Contacts 8 Liquid Temperature Gage with Alarm Contacts 9 Pressure Switch with Alarm Contacts 10 Pressure Vaccuum Gage 11 Tap Changer 12 Seismic Tie Down Bracket 13 Drain Valve in Padlockable Enclosure 14 Alarm Contact Terminations 15 Grounding Bus Bar 16 Fuse Block (for LV distribution) The transformer is RAL9016 (white) in color, with natural convection cooling. 3.2 Accessories 3.2.1 Gages and Alarm Contacts The transformers include as standard accessories, gages with form C, dry alarm contacts, for Overtemperature (8). The Overtemperature alarm contacts are preset for 105 C (Alarm) and 115 C (Trip). As an available option, additional gages and alarm contacts can be provided for Over-pressure (7,9,10), and Liquid Level (8). The gages are located in a NEMA 1 enclosure mounted to the left hand side of the transformer tank. The enclosure is able to be locked with a customer-supplied LOTO hasp and lock. The contacts are rated for 230 VAC. The terminal blocks for the alarm contacts are located in a separate, NEMA 3R control box (14) on the left hand side of the transformer tank. 12 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC 3 Mechanical Design 3.2.2 LV Fuse Block The transformer, if ordered with option 3_1: 80A Internal MVPP Control Power, will include a 100 A fuse block with 80A, Class J fuses (16). This fuse block is tapped from one set of low voltage bushings, and provides the overcurrent protection for the supply conductors to the low voltage power distribution of the Medium Voltage Power Platform. 3.2.3 Sampler Valve A sampling valve for the dielectric fluid is included in a separate external enclosure on the lower left hand side of the High Voltage side of the transformer tank (13). 3.2.4 Medium Voltage Switch The transformer includes a three phase, under oil, two position load break switch (4). The switch is located in the same NEMA 1 external cabinet as the gages, on the left hand side of the High Voltage side of the transformer tank. 3.2.5 Grounding A grounding bus bar of tin plated copper is included in the low voltage compartment of the transformer (15). It is mounted to the lower left hand side of the sidewall of the low voltage compartment. This grounding bus receives the equipment grounds of the components on the Medium Voltage Power Platform (MVPP), and has terminations for the conductors which connect to the exterior ground pads of the MVPP, as detailed in the MVPP circuit diagrams. Technical Description SC_MVPP_4w_Trafo-TD-en-10 13

3 Mechanical Design SMA America, LLC 3.3 Mechanical Properties Item Description Value 1 Cabinet 30 inch deep cabinet 2 Cabinet Hardware Penta-head cabinet door bolts 3 Coatings RAL9016 White topcoat 4 Cover Bolted cover with handhole 5 Strain Relief Removable supports are provided for each set of low voltage bushings in the low voltage compartment, to provide strain relief for the incoming conductors. 6 Equipment Door Grounding The doors of the HV compartment, LV compartment, and Gage Enclosure are grounded with grounding conductors, to the compartment wall. 7 Nameplate Conforming to ANSI C57.12.00 14 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC 4 Routine Testing 4 Routine Testing In addition to robust design type tests, every Medium Voltage Transformer undergoes end-of-line production testing. Routine testing is in accordance to ANSI / IEEE C57.12.00 and C57.12.90. These tests include: Item Test 1 Impulse Test 2 Resistance Measurement 3 Ratio Test 4 Polarity and Phase Relation 5 No-load losses @ 20C 6 Losses @ 85C 7 Impedance Voltage 8 Applied Voltage (hi-pot) Test 9 Induced Voltage Test 10 Continuity Test 11 Leak Test Technical Description SC_MVPP_4w_Trafo-TD-en-10 15

5 Electrical Data SMA America, LLC 5 Electrical Data 5.1 General Design The MVTs are suitable for operation with pulsed inverters. The MVTs are designed for voltages on the low voltage windings, that can exhibit a voltage gradient du/dt of up to 500 V/µs to ground. A shield winding is included between the low voltage and high voltage windings, grounded to the tank, which serves as an additional du/dt filter. The MVTs are designed to tolerate the voltages that arise during pulsed operation of the inverters. These voltages can exceed the RMS voltages, and are considered in the design of the insulation. 16 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC 5 Electrical Data 5.2 Datasheet of 1MVA Transformer using SC500HE-US Inverters Item Description Value 1 Output Power Nominal apparent power of 1,000 kva 2 Overload Capacity No 3 Primary Voltage (kv) 12.47 / 13.8 / 20.6 / 24.9 / 27.6 / 34.5 4 Primary Taps 2% 2.5% taps above and 2% 2.5% taps below nominal 5 Nominal Current, Primary (A) 46.3 / 41.9 / 28.1 / 23.2 / 21 / 16.8 6 Secondary Voltage (V) 200Y : 200Y 7 Secondary Current (A) 1,444 8 Primary BIL (kv) 95 / 95 / 125 / 125 /150 / 150 9 Secondary BIL (kv) 30 10 Vector Group Dy1y1 11 Frequency (Hertz) 60 12 Impedance Voltage Z HV-(LV1 + LV2) (%) 5.0 10.0 13 Impedance Voltage Z HV-LV1 (%) 4.0 6.6 14 Impedance Voltage Z HV-LV2 (%) 4.0 6.6 15 Impedance Voltage Z LV1-LV2 (%) > 9.0 16 No Load Losses (Watts, @20C) 1,100 ± 10% 17 Short Circuit Losses (Watts, @85C) 9,000 ± 10% 18 Tap Changer No load, 5 position tap changer 19 Primary Bushings Qty (6) deadbreak, one piece bushings, 600 A 20 Primary Configuration Dead Front Loop Feed 21 Secondary Configuration Live front 22 Load Break Switching Three phase, 2-position loadbreak switch (200 A at 34.5 kv) 23 Cooling Class KNAN Technical Description SC_MVPP_4w_Trafo-TD-en-10 17

5 Electrical Data SMA America, LLC 24 Dielectric Fluid Biodegradable Fluid 25 Ambient Temperature Range 20 C +50 C ( 40 C available upon request) 26 Temperature Rise 65 degree average winding rise 27 Duty Cycle 100% continuous operation; designed for step-up operation 28 Coil Material Aluminum or Copper 29 Electrostatic Shield Winding Between Pri & Sec Windings 30 Elevation 1,000 m above sea level 31 Sound Level NEMA TR1 Standard 32 Secondary bushings Qty (6) integral aluminum 6-hole spade bushings, plus (1) low voltage bushing for the electrostatic shield winding. 1,500 A rated each 33 Gages and Fittings Thermometer, Dial Type, with Alarm Contacts (optional) Liquid Level Gage with Alarm Contact (optional) Pressure/Vaccuum Gage with Contacts Schrader Valve Pressure Relief Device, 50 SCFM Drain Valve with Sampler Nitrogen Blanket 34 Overcurrent Protection Overload and current limiting fuses in series 35 Arresters Not Included 36 Certifications UL Listed 37 Coil Type 4-winding 18 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC 5 Electrical Data 5.3 Datasheet of 1MVA Transformer using SC500CP-10 / SC500CP-US Inverters Item Description Value 1 Output Power Nominal apparent power of 1,000 kva 2 Overload Capacity Nominal +10% up to 25 C Nominal +4% up to 40 C 3 Primary Voltage (kv) 12.47 / 13.8 / 20.6 / 24.9 / 27.6 / 34.5 4 Primary Taps 2% 2.5% taps above and 2% 2.5% taps below nominal 5 Nominal Current, Primary (A) 46.3 / 41.9 / 28.1 / 23.2 / 21 / 16.8 6 Secondary Voltage (V) 270Y : 270Y 7 Secondary Current (A) 1,070 (+10% up to 25 C) 8 Primary BIL (kv) 95 / 95 / 125 / 125 /150 / 150 9 Secondary BIL (kv) 30 10 Vector Group Dy1y1 11 Frequency (Hertz) 60 12 Impedance Voltage Z HV-(LV1 + LV2) (%) 5.0 10.0 13 Impedance Voltage Z HV-LV1 (%) 14 Impedance Voltage Z HV-LV2 (%) 15 Impedance Voltage Z LV1-LV2 (%) 4.0 6.6 4.0 6.6 > 9.0 16 No Load Losses (Watts, @20C) 1,100 ± 10% 17 Short Circuit Losses (Watts, @85C) 9,000 ± 10% 18 Tap Changer No load, 5 position tap changer 19 Primary Bushings Qty (6) deadbreak, one piece bushings 20 Primary Configuration Dead Front Loop Feed 21 Secondary Configuration Live front 22 Load Break Switching Three phase, 2-position loadbreak switch rated 200 A at 34.5 kv 23 Cooling Class KNAN Technical Description SC_MVPP_4w_Trafo-TD-en-10 19

5 Electrical Data SMA America, LLC 24 Dielectric Fluid Biodegradeable Fluid 25 Ambient Temperature Range 20 C to +50 C ( 40 C available upon request) 26 Temperature Rise 65 degree average winding rise 27 Duty Cycle 100% continuous operation; designed for step-up operation 28 Coil Material Aluminum or Copper 29 Electrostatic Shield Winding Between Pri & Sec Windings 30 Elevation 1,000 m above sea level 31 Sound Level NEMA TR1 Standard 32 Secondary bushings Qty (6) integral aluminum 6-hole spade bushings, plus (1) low voltage bushing for the electrostatic shield winding. 33 Gages and Fittings Thermometer, Dial Type, with Alarm Contacts (optional) Liquid Level Gage with Alarm Contact (optional) Pressure/Vaccuum Gage with Contacts Schrader Valve Pressure Relief Device, 50 SCFM Drain Valve with Sampler Nitrogen Blanket 34 Overcurrent Protection Overload and current limiting fuses in series 35 Arresters Not Included 36 Certifications UL Listed 37 Coil Type 4-winding 20 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC 5 Electrical Data 5.4 Datasheet of 1.26 MVA Transformer using SC630CP-10 / SC630CP-US Inverters Item Description Value 1 Output Power Nominal apparent power of 1,260 kva 2 Overload Capacity Nominal +10% up to 25 C Nominal +4% up to 40 C 3 Primary Voltage (kv) 12.47 / 13.8 / 20.6 / 24.9 / 27.6 / 34.5 4 Primary Taps 2% 2.5% taps above and 2% 2.5% taps below nominal 5 Nominal Current, Primary (A) 58.4 / 52.8 / 53.4 / 29.3 / 26.4 / 21.1 6 Secondary Voltage (V) 315Y : 315Y 7 Secondary Current (A) 1,155 (+10% up to 25 C) 8 Primary BIL (kv) 95 / 95 / 125 / 125 /150 / 150 9 Secondary BIL (kv) 30 10 Vector Group Dy1y1 11 Frequency (Hertz) 60 12 Impedance Voltage Z HV-(LV1 + LV2) (%) 5.0 10.0 13 Impedance Voltage Z HV-LV1 (%) 4.0 6.6 14 Impedance Voltage Z HV-LV2 (%) 4.0 6.6 15 Impedance Voltage Z LV1-LV2 (%) > 9.0 16 No Load Losses (Watts, @20C) 1,350 ± 10% 17 Short Circuit Losses (Watts, @85C) 11,000 ± 10% 18 Tap Changer No load, 5 position tap changer 19 Primary Bushings Qty (6) deadbreak, one piece bushings 20 Primary Configuration Dead Front Loop Feed 21 Secondary Configuration Live front Technical Description SC_MVPP_4w_Trafo-TD-en-10 21

5 Electrical Data SMA America, LLC 22 Load Break Switching Three phase, 2-position loadbreak switch rated 200 A at 34.5 kv 23 Cooling Class KNAN 24 Dielectric Fluid Biodegradeable Fluid 25 Ambient Temperature Range 20 C +50 C ( 40 C available upon request) 26 Temperature Rise 65 degree average winding rise 27 Duty Cycle 100% continuous operation; designed for step-up operation 28 Coil Material Aluminum or Copper 29 Electrostatic Shield Winding Between Pri & Sec Windings 30 Elevation 1,000 m above sea level 31 Sound Level NEMA TR1 Standard 32 Secondary bushings Qty (6) integral aluminum 6-hole spade bushings, plus (1) low voltage bushing for the electrostatic shield winding. 33 Gages and Fittings Thermometer, Dial Type, with Alarm Contacts (optional) Liquid Level Gage with Alarm Contact (optional) Pressure/Vaccuum Gage with Contacts Schrader Valve Pressure Relief Device, 50 SCFM Drain Valve with Sampler Nitrogen Blanket 34 Overcurrent Protection Overload and current limiting fuses in series 35 Arresters Not Included 36 Certifications UL Listed 37 Coil Type 4-winding 22 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC 5 Electrical Data 5.5 Datasheet of 1.5 MVA Transformer using SC720CP-10 / SC720CP-US / SC760CP-10 / SC750CP-US Inverters Item Description Value 1 Output Power Nominal apparent power of 1,500 kva 2 Overload Capacity Nominal +10% up to 25 C Nominal +4% up to 40 C 3 Primary Voltage (kv) 12.47 / 13.8 / 20.6 / 24.9 / 27.6 / 34.5 4 Primary Taps (4)-2.5% taps above and (2)-2.5% taps below nominal 5 Nominal Current, Primary (A) 69.5 / 62.8 / 42.1 / 34.8 / 31.4 / 25.1 6 Secondary Voltage (V) 342Y : 342Y 7 Secondary Current (A) 1,267 (+10% up to 25 C) 8 Primary BIL (kv) 95 / 95 / 125 / 125 /150 / 150 9 Secondary BIL (kv) 30 10 Vector Group Dy1y1 11 Frequency (Hertz) 60 12 Impedance Voltage Z HV-(LV1 + LV2) (%) 5.0 10.0 13 Impedance Voltage Z HV-LV1 (%) 4.0 6.6 14 Impedance Voltage Z HV-LV2 (%) 4.0 6.6 15 Impedance Voltage Z LV1-LV2 (%) > 9.0 16 No Load Losses (Watts, @20C) 1,600 ± 10% 17 Short Circuit Losses (Watts, @85C) 13,000 ± 10% 18 Tap Changer No load, 5 position tap changer 19 Primary Bushings Qty (6) deadbreak, one piece bushings 20 Primary Configuration Dead Front Loop Feed 21 Secondary Configuration Live front Technical Description SC_MVPP_4w_Trafo-TD-en-10 23

5 Electrical Data SMA America, LLC 22 Load Break Switching Three phase, 2-position loadbreak switch rated 200 A at 34.5 kv 23 Cooling Class KNAN 24 Dielectric Fluid Biodegradeable Fluid 25 Ambient Temperature Range 20 C +50 C ( 40 C available upon request) 26 Temperature Rise 65 degree average winding rise 27 Duty Cycle 100% continuous operation; designed for step-up operation 28 Coil Material Aluminum or Copper 29 Electrostatic Shield Winding Between Pri & Sec Windings 30 Elevation 1,000 m above sea level 31 Sound Level NEMA TR1 Standard 32 Secondary bushings Qty (6) integral aluminum 6-hole spade bushings, plus (1) low voltage bushing for the electrostatic shield winding. 33 Gages and Fittings Thermometer, Dial Type, with Alarm Contacts (optional) Liquid Level Gage with Alarm Contact (optional) Pressure/Vaccuum Gage with Contacts Schrader Valve Pressure Relief Device, 50 SCFM Drain Valve with Sampler Nitrogen Blanket 34 Overcurrent Protection Overload and current limiting fuses in series 35 Arresters Not Included 36 Certifications UL Listed 37 Coil Type 4-winding 24 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC 5 Electrical Data 5.6 Datasheet of 1.6 MVA Transformer using SC800CP-10 / SC800CP-US Inverters Item Description Value 1 Output Power Nominal apparent power of 1,600 kva 2 Overload Capacity Nominal +10% up to 25 C Nominal +4% up to 40 C 3 Primary Voltage (kv) 12.47 / 13.8 / 20.6 / 24.9 / 27.6 / 34.5 4 Primary Taps 2% 2.5% taps above, 2% 2.5% taps below, +7.5%, +10.0% nominal 5 Nominal Current, Primary (A) 74.1 / 67 / 44.9 / 37.1 / 33.5 / 26.8 6 Secondary Voltage (V) 360Y : 360Y 7 Secondary Current (A) 1,283 (+10% up to 25 C) 8 Primary BIL (kv) 95 / 95 / 125 / 125 /150 / 150 9 Secondary BIL (kv) 30 10 Vector Group Dy1y1 11 Frequency (Hertz) 60 12 Impedance Voltage Z HV-(LV1 + LV2) (%) 5.0 10.0 13 Impedance Voltage Z HV-LV1 (%) 14 Impedance Voltage Z HV-LV2 (%) 15 Impedance Voltage Z LV1-LV2 (%) 4.0 6.6 4.0 6.6 > 9.0 16 No Load Losses (Watts, @20C) 1,700 ± 10% 17 Short Circuit Losses (Watts, @85C) 14,000 ± 10% 18 Tap Changer No load, 5 position tap changer 19 Primary Bushings Qty (6) deadbreak, one piece bushings 20 Primary Configuration Dead Front Loop Feed 21 Secondary Configuration Live front 22 Load Break Switching Three phase, 2-position loadbreak switch rated 200 A at 34.5 kv Technical Description SC_MVPP_4w_Trafo-TD-en-10 25

5 Electrical Data SMA America, LLC 23 Cooling Class KNAN 24 Dielectric Fluid Biodegradeable Fluid 25 Ambient Temperature Range 20 C +50 C ( 40 C available upon request) 26 Temperature Rise 65 degree average winding rise 27 Duty Cycle 100% continuous operation; designed for step-up operation 28 Coil Material Aluminum or Copper 29 Electrostatic Shield Winding Between Pri & Sec Windings 30 Elevation 1,000 m above sea level 31 Sound Level NEMA TR1 Standard 32 Secondary bushings Qty (6) integral aluminum 6-hole spade bushings, plus (1) low voltage bushing for the electrostatic shield winding. 33 Gages and Fittings Thermometer, Dial Type, with Alarm Contacts (optional) Liquid Level Gage with Alarm Contact (optional) Pressure/Vaccuum Gage with Contacts Schrader Valve Pressure Relief Device, 50 SCFM Drain Valve with Sampler Nitrogen Blanket 34 Overcurrent Protection Overload and current limiting fuses in series 35 Arresters Not Included 36 Certifications UL Listed 37 Coil Type 4-winding 26 SC_MVPP_4w_Trafo-TD-en-10 Technical Description

SMA America, LLC 6 Contact 6 Contact If you have technical problems with our products, please contact our Serviceline. We require the following information in order to provide you with the necessary assistance: Inverter type Serial number of the Sunny Central Type and number of modules connected Event number or display message of the Sunny Central Type of communication, if applicable Type of fault signaling contact connected, if applicable SMA Solar Technology America, LLC 6020 West Oaks Blvd, Ste 300 Rocklin, CA 95765 Tel. +1 916 625 0870 Tel. +1 877-MY SMA TECH Tel. +1 877 697 6283 (Toll free, available for USA, Canada and Puerto Rico) Fax +1 916 625 0871 Service@SMA-America.com www.sma-america.com SMA Solar Technology Canada Inc. 2425 Matheson Blvd, 8th Floor Mississauga, ON L4W 5K5, Canada Tel. +1 877 506 1756 (Toll free, available for Canada) Service@SMA-Canada.ca www.sma-canada.ca Technical Description SC_MVPP_4w_Trafo-TD-en-10 27

SMA Solar Technology www.sma-solar.com SMA America, LLC www.sma-america.com