Summit Series Integrated ozone Systems

Similar documents
GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

Power consumption (kw)

API Marine. BMS Presentation. Ballast Measurement Systems

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MC4-50 Feeding System

Sanitary Type Electronic Flow Switches

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

Electronic Flow Switches

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

In-Line Electronic Flow Switches

MUELLER FALLING FILM CHILLERS

Centro-Matic Automatic Lubrication Systems System Controls

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

HYDROSTATIC TEST PUMPS

4 Posiflow Proportional Solenoid Valves

How To Clean Up A Reactor Water Cleanup

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

In-Line Electronic Flow Switches

Designed for multi-injector endurance testing, the

Ammonia Detection System Codes and Design Specifications

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Electric Flow Boiler

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

The First Step in Effluent Treatment

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

REGULATORS 175/153 Series

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Heating Water by Direct Steam Injection

Ingersoll Rand. Heat-Of-Compression Air Dryers

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Emergency Response Guide

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Fire Pump Plan Review March 2010

Medical Air Systems: Scroll

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration

Nirvana. Cycling Refrigerated Dryers

Some Criteria for Choosing a Steam Boiler for a Microbrewery

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

CRAC Precision climate control units for data centres

Cooling kw Heating kw

G234X-55 Conventional Gas Boiler

Element D Services Plumbing

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Battery Powered Thermal Mass Flow Meters for Gases

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

SUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers.

REFRIGERATED COMPRESSED AIR DRYERS

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

HL Series - Commercial Heaters Tankless Water Heating Solutions

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

COMBIMASS. Technical Data COMBIMASS eco-bio +

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Commercial Semi-Instantaneous Water Heaters

In-Line Air Separators

NAVIEN AMERICA INC FITCH AVENUE

1805 Series Relief Valves

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

RECON WATER HEATER INSTALLATION FORM

BB-18 Black Body High Vacuum System Technical Description

OEM-EP Pressure Controllers

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

300 Series PA Pump and Cooler Assemblies

Battery Powered Thermal Mass Flow Meters for Gases

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

LG Electronics AE Company, Commercial Air Conditioning

Galvanic Parts Per Million Dissolved Oxygen Systems

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Open channel & partially filled pipe Ultrasonic flow meters

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Light Duty Commercial Electric Water Heater

ECOCIAT. Domestic hot water heat recovery unit

Marine after-treatment from STT Emtec AB

Battery Powered Digital Mass Flow Meters for Gases

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

Rackmount Intelligent Pressure Scanners

Air Eliminators and Combination Air Eliminators Strainers

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Fisher 377 Trip Valve

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Reliability Accuracy Performance

Installing a Probe. Typical Installation

VSO MAX HP High Flow Proportional Valve

D. Open hydronic systems, including [condenser] [fluid-cooler spray] water, shall have the following water qualities:

Refrigeration Compressed Air Dryer Buran Ultrapulse

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Transcription:

Summit Series Integrated ozone Systems Features Modular Ozone Chassis Design Stainless Steel Frame and Enclosures Air-Cooled Ceramic and Titanium Reactor Cell Over-Temperature Protection Optional Degas Separator Redundant Backflow Prevention Complete Systems The Summit Series integrated ozone systems eliminate the complexity of integrating the four critical elements of ozone systems: feed gas preparation/ oxygen concentration, ozone generation, mass transfer, and process control. All Summit Series systems are complete and fully integrated ozone systems that seamlessly combine these elements into sanitary, splash-resistant, stainless steel skid-based packages. The performance and simplicity of Pacific Ozone s integrated ozone systems make them ideal platforms Controls 4-20mA or 0-10VDC Input Variable Output Control Programmable PID Controller Dissolved Ozone Sensor Ambient Ozone Detector with Safety Interlock Remote On/Off Control Reactor Pressure Control Feed Gas Flow Control for countless ozone processes, including: Beverage industry Bottled water Food processing Industrial water treatment and more High Performance Model: Summit with 150 Gallon Vessel Summit Series systems are available for a variety of flow rates and process requirements: 5-200 gallon per minute water flow rates at 0.5-10 pounds per day ozone production. This range of performance allows Pacific Ozone systems to be configured to address the finest application of ozone at a small food processing plant to high ozone production for a large industrial Complete Integrated Solutions. Single Trusted Source. water treatment facility.

A Strong Foundation The Summit Series integrated ozone systems are built on the strong foundation of Pacific Ozone s patented ozone technology. Five standard models are available producing 0.6 to 3.2 pounds per day ozone utilizing high-quality plant air. If plant air is unavailable or insufficient, three models with onboard oil-less air compression are available providing 0.5 to 1.3 pounds of ozone per day. Custom, highoutput systems producing up to 10 pounds of ozone per day are also available. Enhanced Mass Transfer Model: Summit with Fat Pipe Mass Transfer System The Summit Series systems are equipped with Pacific Ozone s unique Enhanced Mass Transfer ozone injection and off-gas destruction system. To ensure consistent supply of ozone-injected water to the process, applications with periodic stops and starts should generally include a mass transfer vessel. Standard stainless steel mass transfer vessels are available at 50 and 150 gallons. Larger mass transfer vessels are also available. Processes that operate continuously with few interruptions are typically best served with the tank-less Fat Pipe mass transfer system, providing complete ozone injection and off-gas destruction without a conventional tank.

Standard Features and Option Packages Standard Summit Series systems include a host of standard features including Remote On/Off ozone control and Remote Lockout, as well as a PID controller and one or two channels of dissolved ozone detection for accurate and reproducible ozone control. An ambient ozone detector with safety interlock is also provided as standard. The ambient ozone detector alarms if the ambient ozone gas concentration reaches the OSHA long-term exposure limit and shuts down ozone production if ambient ozone exceeds the OSHA short-term exposure limit. Standard Summit systems may be augmented with the PLUS option package, which adds the Degas Separator option. The Degas Separator reduces unwanted ozone off-gas at the site of application by collecting undissolved ozone gas from the water stream and shunting it to the system ozone destruct. Additional optional features are also available, including process pumps and process inputs, and DirectDrive Control. Optional air compressor packages are also available, if needed. Options Standard Features PLUS Option Package Additional Options 4-20mA/0-10 VDC Inputs Remote On/Off Remote Lockout PID Controller Dissolved Ozone Detection (One or Two Channels) Ambient Ozone Detector Degas Separator Process Pumps Additional Process Inputs DirectDrive Control System Air Compressor Built to Last The Summit Series integrated ozone systems are engineered to meet ozone process requirements found in the most demanding applications; yet they are easy to install, simple to operate, and will provide years of trouble-free operation. www.pacificozone.com

Model: Summit Series with 50 Gallon Mass Transfer Vessel 53.00 1346 PROCESS INLET 10.33 262 30.00 762 34.66 880 8.17 208 55.14 1401 57.50 1461 70.93 1802 PROCESS OUTLET 24.36 619 69.00 1753 13.50 343 14.36 365 Dimensions: inches [mm] Note: Drawings of other Summit Series models are available upon request.

Model: Summit Series with 150 Gallon Mass Transfer Vessel.75 19 53.00 1346 PROCESS INLET 30.00 762 34.66 880 1.75 44 55.14 1401 97.75 2483 PROCESS OUTLET 69.00 1753 82.67 2100 16.00 406 12.85 327 12.85 327 Dimensions: inches [mm] Note: Drawings of other Summit Series models are available upon request. www.pacificozone.com

Model: Summit Series with Fat Pipe Mass Transfer System 7.68 195 15.83 402 34.66 880 31.00 787 1.99 51 66.00 1676 PROCESS INLET PROCESS OUTLET 23.98 609 17.66 449 31.00 787 2.19 56 2.56 65 Dimensions: inches [mm] Note: Drawings of other Summit Series models are available upon request.

Technical Specifications Model/ Part Number* Ozone Generator Model** Max. Ozone Production lbs/day (grams/hour) Performance (at 2 ppm O 3 ) Power Consumption Water Inlet/Outlet Compressed Air Inlet Fitting gpm (lpm) watts inches (mm) inches (mm) Summit A11/ R-SA11XXY R-SA11XXYP SGA11 0.6 (12) (95) 00 Summit A21/ R-SA21XXY R-SA21XXYP SGA21 1.0 (18) 40 (151) 00 Summit A22/ R-SA22XXY R-SA22XXYP SGA22 1.6 (30) 65 (246) 00 Summit A23/ R-SA23XXY R-SA23XXYP SGA23 2.4 (45) 100 (379) 00 Summit A24/ R-SA24XXY R-SA24XXYP SGA24 3.2 (60) 130 (492) 00 Summit C11/ R-SC11XXY R-SC11XXYP SGC11 0.5 (10) 20 (76) 00 N/A Onboard Air Compressor Summit C21/ R-SC21XXY R-SC21XXYP SGC21 0.8 (16) 35 (132) 00 N/A Onboard Air Compressor Summit C22/ R-SC22XXY R-SC22XXYP SGC22 1.3 () 55 (208) 00 N/A Onboard Air Compressor Notes: * The value of XX in the part number indicates the mass transfer vessel size (Fat Pipe = 00, 50 gal. = 05, 150 gal. = 15, etc.). The value of Y indicates the number of channels dissolved ozone detection (1 or 2). The letter P indicates the PLUS option package. ** See ozone generator cut sheets for additional specifications pertaining to the generators. Typical system water flow rate at 2 ppm dissolved ozone concentration. Performance as tested with municipal water at 70 F (21 C). Ozone Mass Transfer System Injection Pump: Stainless steel, sized to system requirements Venturi: MIC natural Kynar injector Back Flow Prevention: Stainless steel check valve and proprietary backflow prevention system Mass Transfer Vessel: Fat Pipe, 50 gal., or 150 gal. standard Larger vessels available Inlet/Outlet: 1.5 stainless steel sanitary connections Larger fittings available Pump Protection: Tank level switch, interlocked Assembly: Stainless steel frame Ozone Destruct System Catalyst: Manganese Dioxide/Copper Oxide Destruct Potential: Sized to application requirements Air Relief Valve: Stainless steel air relief vent Operating Temperature: 130º-140º F (54º-60º C), electronically controlled www.pacificozone.com

Operational Requirements Model Compressed Air Flow Compressed Air Pressure Water Pressure Electrical Requirement scfm (lpm) psig (bar) psig (bar) volts, Hz Summit A11 6 (170) 30 (2.07) 20-30 (1.4-2.1) 230V 50/60Hz, 1 phase 30A Circuit Summit A21 6 (170) 30 (2.07) 20-30 (1.4-2.1) 230V 50/60Hz, 1 phase 30A Circuit Summit A22 6 (170) 30 (2.07) 20-30 (1.4-2.1) 230V 50/60Hz, 1 phase 30A Circuit Summit A23 12 (340) 30 (2.07) 20-30 (1.4-2.1) 230V 50/60Hz, 1 phase 30A Circuit Summit A24 12 (340) 30 (2.07) 20-30 (1.4-2.1) 230V 50/60Hz, 1 phase 30A Circuit Summit C11, C21, C22 N/A* N/A* 20-30 (1.4-2.1) 230V 50/60Hz, 1 phase 30A Circuit * Not Applicable - All Summit C-Line models (C11, C21, and C22) include onboard air compression. 6160 Egret Court Benicia, California 94510 p: (707) 747.9600 f: (707) 747.9202 www.pacificozone.com Copyright 2008 Pacific Ozone Technology, Inc. All rights reserved. The Pacific Ozone logo and Floating Plate Technology are trademarks of Pacific Ozone Technology, Inc. CS-SUM-002/1108