TABLE OF CONTENTS. Specification... 2 Preperation for equipment.3 DP-3810 Indicator..6 Power Supply.6

Similar documents
BW-500 BED WEIGHER USER MANUAL

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

Operating Manual Electronic Wheelchair Scale with cable display M50610

AUPS-C20. User Manual MODEL: VESA Mount Intelligent UPS Module, 9 V ~ 28 V DC Input, 100 W Power Output, Network Remote Management Support

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Keep it Simple Timing

User Guide Reflow Toaster Oven Controller

AUPS Series. User Manual MODEL: VESA Mount Intelligent UPS Module 12 V DC Input or 9 V ~ 36 V DC Input Network Remote Management Support

1. SAFETY INFORMATION

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series

TP- 051 GPS RECEIVER

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

XP Series Balances Operation Manual

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

Physical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

USB-Blaster Download Cable User Guide

Contents. ST9612 Model WIC Printer. Get the original printer s information. Edited 11/04/15

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI

3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

PM1122 INT DIGITAL INTERFACE REMOTE

CYMAQ Marking System AS200 + DS7050 N-14

High precision counting scale. Operation Manual. l RCZ-A Series

User Manual. EtherUSB

Orbit PCI Mk 2 Network Card. User Manual. Part No Issue 4

Maintaining the Content Server

Product Regulatory Compliance Datasheet ediscovery 8200

User's Guide. Integrating Sound Level Datalogger. Model Introduction

GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G

Instruction Manual FL

telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR

FOR MORE INFORMATION or from a non-telstra phone and say pre-paid telstra.com/ppmbb visit a telstra store or partner

Pocket Tach 99 (PT99) Non-Contact Tachometer

User Guide. Temperature and Humidity Datalogger. Model 42280

POCKET READER AND POCKET READER EX MANUAL

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Product Regulatory Compliance Datasheet ediscovery 8100

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Dynatek 6080RS multimeter

M O D U L E - 7 E Model CS-Caliprompter Operator s Manual

GSM HOME SECURITY SYSTEM

OCSM Series. High Resolution Digital Crane Scale. User Guide

User's Guide DylosLogger Software Version 1.6

CASTON. Crane Scale. OWNER S MANUAL (BT Ver.) 9007-CT3-BT

BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide

How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip

Configuring the Siemens TC35 modems for use with the MI2292

MANUAL PC1000R

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Using the Parani SD1000U/SD1000 with Carlson SurvCE

Voice Over Internet Protocol (VoIP) Configuration

2» 10» 18» 26» PD »

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

User Manual. EtherUSB

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

How-To Set Custom Scale Format for FedEx Ship Manager

PT Mbps Powerline Adapter. User Guide

OCS-S High Resolution Digital Crane Scale

Troubleshooting and Diagnostics

Instruction Manual Crane Scales PCE-HS Series

Bluetooth to Serial Adapter

DUKANE Intelligent Assembly Solutions

Appearance and Buttons

Communication bridge Xcom-MS User Manual

LCD Drawer User Manual

GETTING TO KNOW YOUR NEW TELSTRA MOBILE WI-FI 4G

Communications Instructions for DOOSAN, FANUC Controls

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

STIM202 Evaluation Kit

3M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

GV-Keyboard. User's Manual V2.0

Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual

User Manual. Video Doorphone CDV-1020AQ

4-Channel Thermometer / Datalogger

My Weigh Ultraship Series User Manual

Product Information Sheet UH36 Hi Pot Tester

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Table of Contents. System Requirement of MP3 Player: Connection and Downloading Downloading DRM10 Files... 8.

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Manual & Technical Documentation V1.1

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

MagIC Installation Manual. Point of Sales Terminals TD06014B

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

POS Integration. Prepared by: Binh Nguyen

4-Port Pocket. USB KVM Switch with USB 2.0 Hub

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Transcription:

0

TABLE OF CONTENTS Specification... 2 Preperation for equipment.3 DP-3810 Indicator..6 Power Supply.6 Panel 7 Key Functions 7 LCD Symbol Description 8 Date & time setting procedure 9 Normal weighing procedure (patient on bed)... 100 How to use BMI feature... 111 How to use tare function... 122 How to use pre-set tare function... 133 Set up your device... 144 Printing function... 15 Error message... 177 Instruction of replacing battery pack..18 1

SPECIFICATION Model M-950 Capacity 600kg x 200g / 1000kg x 500g Accuracy ±300g Weight Unit 0.2kg / 0.5kg LCD Display 1.0 inch LCD display with 5 and 1/2 digits Dimension Weighing Area- 92 X 3.5 X12.5 cm Key Functions Power Supply Operation Temperature ON/OFF, ZERO, TARE, BMI, UNIT, HOLD, PRINT, 0-9 Rechargeable battery pack(7.2v 2000mA) 12V 2A switching adaptor 5 ~ 35 2

PREPARATION FOR MEASUREMENT 1. Using the handle of weigh beam 2. Place weigh beams under bed next to the bed casters. 3. Set the unit on a stable, level surface. When the bubble indicator is in the centre of the circle, M-950 is leveled correctly. Bubble indicator: Good Wrong All four feet must touch the surface to make sure that M-950 does not rock. 3

4. Connect the 4 weighing pads to the indicator via the colour coded cables. 5. Switch scale on, check at zero and push bed forward and onto the weigh beams. We strongly recommend two people to operate the procedure. 4

Before moving bed on the weigh beam, please turn on the scale!! You must make sure that the connecting cable is not caught under the measuring foot, otherwise faulty measurements may result. 6. Four bed casters are now placed well on weighing pads. 5

DP3810 Indicator 1. Make sure the battery pack is installed in the battery box of indicator, or, plug the connector of AC ADAPTER (12V 2A) in the indicator. 2. Plug the cable to the printer, and then connect its 9D connector to the indicator. POWER SUPPLY The INDICATOR uses a rechargeable battery pack, or an AC adaptor. When the indicator displays (low battery indication), please plug in the AC adaptor for operation and rechargeable batteries (where rechargeable batteries are installed) for at least 4.5 hours if batteries are fully charged. The battery should be recharged at least every 3 months regardless if it is used or not. After a long period in storage, e.g. over 3 months, the battery should run a full cycle (charge/discharge) to allow it to restore to full capacity. 6

PANEL KEY FUNCTIONS Key ON/OFF PRINT BMI Description Switching on/off the scale Data transmission via interface Determination of Body Mass Index HOLD ZERO TARE UNIT Hold function / determination of stable weighing value The scale is reset to 0.0kg display. It is possible to set max. up to 2% of maximal load for verified scales, and 2% or 100% of maximal load for common scales (possibility of selection in the menu) Taring the scale Press this key to select weight units (kg and lb). NOTE: only kg unit can be used in approval mode. 0-9 Entering digits 7

LCD SYMBOL DESCRIPTION Definitions Stable symbol: To indicate that the weight is stable. Minor weight: Weight under zero. Zero symbols: Weight is at zero point. Power Index: When the indicator show LO is means Battery need to charge. 8

DATE & TIME SETTING PROCEDURE Press HOLD key 3 sec into the TIME SETTING mode, beginning with the top row, in the flashing space. Press HOLD to change flashing space. EX: To input Dec 25, 2008, 8:00am Enter year. Press HOLD to change flashing space. Enter date. Ex: 12/25 enter 12.25 Press HOLD to change flashing space. Enter time. Display show YYYY MM.DD TT:SS 9

NORMAL WEIGHING PROCEDURE (patient on the bed) Turn On the scale using ON/OFF key. **(before moving bed on the weigh bridge) Setting the PRE-TARE value (bed weight), scale will automatically perform Tare function and the minus (-) sign will appear in front of Pre-Tare value. Setting Pre-Tare Function please refer HOW TO USE PRE-TARE FUNCTION (page.14) Place both the weigh bridges under the bed and push the bed on the scale. The upper display will show the net weight of the patient. Now if you want BMI also, simply long press BMI key, the middle display will show the last height of the patient and extreme digit will blink. Key in the height measurement of patient using 0~9 key and press ENTER key. The third display will show the BMI of the patient To print out the weighing result, press PRINT key. 10

HOW TO USE BMI FEATURE Use the instrument to calculate your BMI and understand your body condition. Please follow below procedure: In normal mode, press BMI key to enter into BMI mode. The display will show last height and the extreme left of figure will flicker. Enter the height by number key. (ex:170cm) Proceed to weigh as normal. The instrument will show the weight, height, and BMI value. At this time, the weight and height can be freely changed, and the BMI value will automatically calculated according to the changed weight and height. Presses HOLD key to lock the weight, height, and BMI value. Press HOLD key again to disable the lock function. Press BMI button to return normal mode and the person can now take off the scale. 11

HOW TO USE TARE FUNCTION In normal mode, place a target which you want to tare its weight (like clothes) on the scale platform. Press TARE to tare the weight of target. LCD will return to zero. Then client stand on the scale and weigh. The result shown is the net weight of client. The weight of his clothes has been tared at step 3. Disable the TARE function or setting tare range (50% or 100%) 12

HOW TO USE PRE-TARE FUNCTION Press ON/OFF to switch on device. Press TARE key 3sec to enable this function. The LCD shows 0.0kg and the Pre-tare arrow is flashing for input target s weight. Input the weight that you wish to deduct. Ex: 0.2kg. Press to finish input. Now you have 0.2kg as your deduction. Weigh 60.2kg and get 60kg as a net weight. For multi-interval model, the pre-tare range only possible to set to 50% of full capacity or equal to Max. 1. 13

SET UP YOUR DEVICE When the scale is switched on, hold the [ZERO] key pressed for about 3 seconds until the display shows successively the SETUP and A.OFF symbols. AUTO-OFF TIME SETUP This enables operator to setup period to shut off device with no operation automatically. BUZZER ON/OFF SETUP This enables operator to setup ON/OFF to the buzzer. When the End is selected, the setting can be finished with the [HOLD] key. 14

PRINTING FUNCTION Weight, BMI and Height results can be printed for records using RS232 interface cable (included in accessory kit). After weighing and calculating BMI simply press PRINT key to print out the results. The format presented below is the standard format of results printout and cannot be changed. Parameters of RS232 interface Set parameters of the scale interface on the connected device. It is not possible to change the scale parameters. Baud rate: 9600 bps Parity check: None Data length: 8 bits Stop bit: 1 bit Handshake: RTS/CTS Data code: ASCII 15

RS232 Pin out Connecting with PC 1. Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories Communication Hyper Terminal. 2. New Connection Description Give new connection a name then click OK. 3. Select Your COM Port Click Connect to select your COM port. Usually there s only one option for select. Then click OK. 4. Port Settings Click Bits per second to set up rate at 9600, Data bits at 8, Parity at None, Stop bits at 1 and Flow control at Hardware. Then click OK to complete your setting. 5. Output Data When the patient has been weighed and BMI calculated, simply press the PRINT key to output data from scale to PC or an Optional Printer. 16

ERROR MESSAGE 17

INSTRUCTION OF REPLACING BATTERY PACK 1. Open the battery door. 2. Disconnect the rechargeable battery pack then replace it. 3. Push the female and male connectors together. 18

4. Push the battery pack into the battery holder then locate the cable connector above the battery pack. 5. Replace and close the battery door. 19

ROHS COMPLIANCE EU Directive 2002/95/EC restrict the use of the 6 substances below in the manufacture of specified types of electrical equipment. The product does not contain any of the restricted substances in concentrations and applications banned by the directive; and for components, the product is capable of being worked on at higher temperatures required by lead-free soldering. The restricted substances and maximum allowed concentrations in the homogenous material are, by weight: Substance Concentration Lead 0.1% Mercury 0.1% PBB (Polybrominated Biphenyls) 0.1% PBDE (Polybrominated Diphenyl Ethers) 0.1% Hexavalant Chromium 0.1% Cadmium 0.01% PRODUCT CONFORMITY Harmonised Standards to Which Conformity is Declared EN60601-1-2 / EN60601-1 93/42/EEC Medical Devices Directive 2014/31/EU Non Automatic Weighing Instrument Directive 20

21