Understanding Intrinsically Safe Fire Detection

Similar documents
Making sense of Intrinsic Safety and Intrinsically Safe Tools

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Hazardous Locations Training

Explosion Protected White Paper Series #1: Imaging Challenges in Explosive Environments

INTERNATIONAL STANDARD

Design of intrinsically safe systems

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.

How To Protect An Explosion

Flame detection across the spectrum. Range Brochure

EXPLOSION SAFETY DOCUMENT FOR THE ATEX 137 DIRECTIVE NEW NAME FOR A FIRE AND EXPLOSION HAZARD ASSESSMENT?

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Products Solutions Services. CompEx training From the process safety experts

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

Variable speed drives for synchronous and asynchronous motors

Controlling fire and explosion risks in the workplace

distributing & controlling system solutions

Safety instructions VEGADIS DIS81.CEIA/V****

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Terminal Box. Specifications TNCN

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Inductive slot sensor

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

Understanding European versus U.S. temperature code ratings for solenoidoperated. A White Paper From ASCO

By: Santiago Consunji American Industrial Systems, Inc.

Zone Hazardous Location

Installation Instructions for Alarm Module Kit A043F059

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

HAZARDOUS AREA TECHNICAL GUIDE

Technical Data. Dimensions

Wilkins Safety Group

Triple Waveband Infra-Red Flame Detection

99/92/EC (ATEX 137) USE

Explosion proof enclosures

Fire Alarm System Accessories

Basics of Explosion Protection

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Hazardous Area Classifications and Protections

IECEX CERTIFICATION SCHEMES VERSUS ATEX DIRECTIVES

JOINT CBA AND SIA GUIDANCE FOR THE STORAGE OF FLAMMABLE LIQUIDS IN SEALED PACKAGES IN SPECIFIED EXTERNAL STORAGE AREAS

SAFETY CLASS, Program

ATEX Fans 08/02/2008. Data subject to change without prior notice

An Introduction to ATEX -

Instructions for Safe Use

AN A Users Guide to Intrinsic Safety

Hazardous location. Definitions

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Inductive sensor NI10-M18-Y1X-H1141

Technical data sheet TDS0070

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

AS/NZS 3000:2007 Amendment 2

Hazardous Area Classifications and Protections

Analogue addressable devices

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

TABLE OF CONTENT

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

FIRE DETECTION AND ALARM SYSTEMS

Site and Storage Conditions for Class 3.1 Flammable Liquids

CONSULTING Training Courses

ATEX GUIDELINES (FIRST EDITION)

CompactLogix Power Supplies Specifications

Take care with oxygen Fire and explosion hazards in the use of oxygen

REVISION NO : 3 August 2010

Magnetic Starter - 30A, 120/240V Coils

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Lockout Specification BW Clip Maintenance-free single gas detector

Design, testing, certification, installation & maintenance

A Tradition of Fire Detection Innovation

ISpac isolators. the perfect system

Thermocoax Isopad Heating Solutions for Hazardous Areas

Class/Division Hazardous Location

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Fig. 2 Option 1 Integrated Design using Physical Separation. Fig. 1 Standard Modular Process Skid Design Concept

This leaflet provides information on

Explosion Protected Electrical Apparatus in the Russian Federation

IGEM/UP/16 Communication 1756

Your Boiler Room: A Time Bomb?

Fire Resistance and Safety in Case of Fire

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Fire detection equipment

What is ATEX? The European Regulatory Framework for Manufacture, Installation and Use of Equipment in Explosive Atmospheres

Presented by: Rich Perry Marsh Risk Consulting

Operating instructions

Explosion Protection. Industrial Automation and Drive Technologies. Products and systems for use in hazardous areas. Brochure November 2010

PLAN REVIEW GUIDE FOR FIRE ALARM

Today's world of increasing

Fire safety in buildings and implementation of European fire test standards

Area Classification Why? Where? How? Who? When?

Service Bulletin SA-008. DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances

Safety Storage Cabinets

Industrial trucks for use in potentially explosive areas - placing on the market in compliance with Directive 94/9/EC and EN

FGM 160 ATEX EC type examination certificate

No. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974

Transcription:

Understanding Intrinsically Safe Fire Detection +44 (0)1634 260133 info@hochikieurope.com www.hochikieurope.com @HochikiEurope Understanding Intrinsically Safe Fire Detection >1

What is Intrinsic Safety? For an electrical product to be Intrinsically Safe it must be incapable of igniting an explosive atmosphere by either spark or heat. This is achieved by ensuring only low currents and voltages enter the hazardous area, and therefore the whole circuit must be considered, not just the device in isolation. An Intrinsically Safe Circuit therefore must restrict the electrical and thermal energy such that ignition of a hazardous atmosphere (explosive gas or dust) cannot occur. Understanding Hazardous Areas The Dangerous Substances and Explosive Atmospheres Regulations 2002 (DSEAR), defines a hazardous area as: any place in which an explosive atmosphere may occur in quantities such as to require special precautions to protect the safety of workers. 2< Understanding Intrinsically Safe Fire Detection

EN60079-10-1 explains that Hazardous areas can be classified into zones based on the amount of time explosive gases, vapours and mists can be found in the atmosphere; 0 An area in which an explosive gas atmosphere is present continuously or for long periods 1 An area in which an explosive gas atmosphere is likely to occur in normal operation 2 An area in which an explosive gas atmosphere is not likely to occur in normal operation and, if it occurs, will only exist for a short time. There is also zone classification for combustible dust: 20 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is present continuously, or for long periods or frequently. 21 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally. 22 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only. Understanding Intrinsically Safe Fire Detection >3

Intrinsically Safe Device Categories When selecting an intrinsically safe device, installers must ensure that the product has the appropriate certification for the zone required. Equipment categories are different to zones; please refer to how the zones and categories correspond below: 0 or 20 = category 1 equipment 1 or 21 = category 2 equipment 2 or 22 = category 3 equipment Please note: Category 1 equipment is also suitable for zones 1, 2, 20 and 22. Category 2 equipment is also suitable for zones 2 and 22. For example, Hochiki s SLR-E-IS and DCD-1E-IS are certified for use in Category 1. This means they are suitable for zones 0, 1, 2, 20, 21 and 22. 4< Understanding Intrinsically Safe Fire Detection

The differences between a standard device and an Intrinsically Safe device Aesthetically, the shape and size of an intrinsically safe smoke detector, heat detector or multi sensor can be very similar to standard devices, however, you will notice additional warning information and zone information printed on an intrinsically safe device. You might find that some devices are non-pulsing, meaning that the LED will not flash when polled. This is primarily because an intrinsically safe device needs to operate at lower voltage than a standard device in order to eliminate any possibility of igniting the explosive atmosphere. It is important that there is no chance of ignition in normal operation or in fault conditions. The low power levels also mean that there is no chance of receiving an electric shock due to excess thermal energy and arcing. And remember, when installing an intrinsically safe device, it is crucial that an intrinsically safe mounting base is used. Understanding Intrinsically Safe Fire Detection >5

The difference between flame proof and intrinsically safe Flameproof Flameproof equipment must be contained in a box strong enough to contain an internal explosion without damage to the box or transmittance outside of the box. The surface must also remain cool enough, not to be able to ignite the explosive atmosphere. In addition, when flameproof equipment is interconnected, flame proof wiring must be used. Flameproof wiring is acceptable if high power is unavoidable, however it is not acceptable to use this method in zone 0 hazardous areas. Intrinsically Safe Intrinsically safe devices operate at much lower power; even the quiescent current is much lower. This therefore means that, depending on the certification, an intrinsically safe device can be used in all classifications of hazardous area. 6< Understanding Intrinsically Safe Fire Detection

Barriers and Modules We have established that standard devices cannot be used in hazardous areas as there is a risk of ignition; therefore low current intrinsically safe devices must be used instead. Of course, buildings do not tend to be completely hazardous; they will have safe areas that require standard devices and hazardous areas that require intrinsically safe devices. Therefore, an intrinsically safe compatible module is designed to interface between the two. Some modules also provide line monitoring for open or short circuits on the wiring connected to both the safe and hazardous areas. It is important to note that a module does not reduce the current in any way, a module is simply used to interface between standard devices and intrinsically safe devices. This means that you must also use an intrinsically safe barrier; it is the barrier that reduces the power that enters the hazardous area. Both the module and the barrier must therefore be installed in the safe area. Understanding Intrinsically Safe Fire Detection >7

SIL Approved Products It is important to note that SIL approved products are not the same as Intrinsically Safe Products. SIL approved products are for use in high risk industries, Intrinsically Safe products are for use in classified hazardous areas. However you may find that some manufacturers, such as Hochiki, offer products that have both SIL and IS certification. SIL is the acronym for Safety Integrity Level. This is a system used to quantify and qualify the requirements for safety instrumented systems. There are four different SIL levels; SIL1, SIL2, SIL3 and SIL4. The international Electro-technical Commission (IEC) introduced the following industry standards to assist operators with quantifying the safety performance requirements for hazardous operations: IEC 61508 Functional Safety of Electrical/ Electronic/ Programmable Electronic Safety-Related Systems IEC 61511 Safety Instrumented Systems for the Process Industry Sector These standards have been widely adopted in the hydrocarbon, oil and gas, petrochemical, transport and process controlled industries as a means of improving safety and availability of Safety Instrumented Systems. As such, these industries are increasingly specifying the requirement for SIL approved fire detection equipment. 8< Understanding Intrinsically Safe Fire Detection

Compliance There are a number of Intrinsically Safe fire detection products on the market. To remain legally compliant, please ensure that the products you select have been certified under the following directives: EU 305/2011 ATEX Directive 94/9/EC* IECEx For further information about intrinsically safe certification, you can visit the following websites: www.baseefa.com www.brecertification.com www.iecex.com *Please note, The new ATEX directive (2014/34/EU) has been published - this will come into force on 20/04/16 and 94/9/EC will be repealed. Understanding Intrinsically Safe Fire Detection >9

Other Resources The HSE website contains some very useful information about hazardous areas: Further information about hazardous areas can be found in BS EN 60079 part 10, please visit the British Standards website for more information: To learn more about Hochiki s intrinsically safe products visit our I.S. product pages on our web site: To learn more about Hochiki s SIL approved range, please visit our SIL2 landing page: Hochiki have a number of free fire safety guides and documents that can be downloaded from the website and our brochure app. Download now by clicking the relevant icon. Hochiki Europe are also an approved supplier of CPD seminars. 10< Understanding Intrinsically Safe Fire Detection