Big Pipe Big Benefits

Similar documents
Royal Seal Gasketed Sewer Pipe

MANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE

PVC Gasketed & Solvent Weld Pipe

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Quality Products, People & Locations

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

PVC PIPE PERFORMANCE FACTORS

pvc well casing & drop pipe

SECTION POLYVINYL CHLORIDE (PVC) PIPE

INDEX. Sec. No. Items Page Nos.

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Shah Rahman Vice President Technical & Municipal Svcs. S&B Technical Products / Hultec Fort Worth, Texas

SECTION 5: SANITARY SEWER SYSTEM DESIGN

Ultra-Rib PVC Storm Sewer Pipe 8" - 30"

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

SANITARY SEWER SPECIFICATIONS

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

Fabricated Drainage Products

CHAPTER 11 STORM DRAINAGE

SECTION STORM DRAINAGE TABLE OF CONTENTS

SPR PE Steel Reinforced Liner

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

SECTION STORM DRAINAGE SYSTEM

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Introduction to Pressure Pipe Rehabilitation with CIPP

SECTION DUCTILE IRON PIPE AND FITTINGS

Product Guide Specification

725-R-599 PIPE LINING. (Revised ) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE

WATER SERVICE 2

Green Thread Product Data

City of Edmonton Page 1 of 5 Foundation Drain Discharge Collection System Guideline November, 2005

SECTION DUCTILE IRON PIPE AND FITTINGS

DIVISION 4300 STORM DRAINAGE

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

MEMORANDUM: RECOMMENDATIONS FOR PIPE MATERIAL SELECTION

SECTION NONREINFORCED CONCRETE SEWER PIPE

Series 4000 Fiberglass Pipe and Fittings

SECTION STORM DRAIN SYSTEM

WATER MAIN CONSTRUCTION TECHNIQUES DEPARTMENT OF PUBLIC WORKS WATER & WASTEWATER DIVISION

CHAPTER 6 - SANITARY SEWER

More inside :: Tackle even the toughest water treatment piping challenges with

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

SECTION 6A STORM DRAIN DESIGN Mar S E C T I O N 6A STORM DRAIN - DESIGN

CHAPTER 11 STORM DRAINAGE

ASTM D 1599 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings

Plastics TECHNICAL AND INSTALLATION MANUAL. (Updated June 10, 2016) TECHNICAL MANUAL TM-PL Charlotte Pipe and Foundry Co.

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

SANITARY GRAVITY SEWER LINE TESTING. B. Section CCTV Inspection of Gravity Sewer Lines

Application Data Important Safety Information

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

SECTION 603 SANITARY SEWER FORCE MAINS

ASTM C76, Class III, Wall B, except as modified herein. Clean natural sand, ASTM C33. Artificial or manufactured sand will not be permitted.

PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET

SECTION 200: STORM SEWER CONSTRUCTION STANDARDS

Wastewater Capital Projects Management Standard Construction Specification

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Section SEWER PIPE INSTALLATION AND TESTING

CIPP for Large Diameter Pressure Pipes. Water Research Foundation Large Diameter Pipe Rehabilitation Seminar 20 January 2016 George Bontus, P.Eng.

X Planning X Quality X Maintenance & Operations

Meets astm d3034 and astm f679. Building essentials for a better tomorrow

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

September 2012 Brunswick County Engineering Department Revision 1.0. Technical Specification GRAVITY SANITARY SEWER SYSTEM

Ductile Iron Pipe Couplings

San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS

BEST PRACTICE GUIDELINES FOR CULVERT LINER SELECTION

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *

SECTION POLYVINYL CHLORIDE (PVC) PIPE

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

SECTION 724 PIPE CULVERTS

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids

Carlon Bore-Gard and Boreable Multi-Gard Raceway

Standard Specifications, Standard Test Methods and Codes for PE (Polyethylene) Piping Systems

SECTION PVC PRESSURE PIPE AWWA C900

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS

PREDICTING THE RESIDUAL LIFE OF PVC SEWER PIPES.

SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

Flowtite Jacking Pipe

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer

Culvert Repair, Materials, and Structural Design 4.4-1

The Unique, Centrifugally Cast, Fiberglass-Reinforced, Polymer Mortar Pipe

Transcription:

Large Diameter PVC Water & Sewer Pipe 30 & 36 Big Pipe Big Benefits Large Diameter PVC Pipe Systems Offer: Corrosion and Abrasion Resistance for Long Service Life Replace High Resistance to Attack from Chemicals Typically Found in Water and Sewer Systems Hydraulic Efficiency for Optimal Fluid Transmission Durability and High Impact Resistance Leak-Free Joints for Low Maintenance Replace High Strength to Weight Ratio Relatively Lightweight for Easy Installation Cost Effectiveness AWWA C905 DR18, DR25, DR32.5, DR41 ASTM F679 PS46, PS115

Large Diameter PVC Water & Sewer Pipe 30 & 36 C905 CIOD Water Pipe Short Form Specifications: Royal Municipal Solutions Gasketed Pressure Pipe shall be manufactured with nominal sizes of 30 and 36 to CIOD dimensions. Dimension Ratios (DR) 18, 25, 32.5 and 41 shall meet the requirements of AWWA C905, Polyvinyl Chloride (PVC) Pressure Pipe and Fittings and be certified to NSF-14. Size DR18 DR25 DR32.5 DR41 30" 36" n/a Stock MTO F679 PS46 and PS115 Sewer Pipe Short Form Specifications: Royal Municipal Solutions Gasketed Sewer Pipe shall be manufactured with nominal sizes of 30 and 36 to CIOD dimensions. Pipe Stiffness 46 psi and 115 psi shall meet the requirements of ASTM F679, Type PSM Polyvinyl Chloride (PVC) Sewer Pipe and Fittings and be certified to NSF-14. Size PS46 PS115 30" 36" Stock MTO

Gasketed AWWA C905 CIOD Pressure Pipe C905 Pressure Specification Data Royal Municipal Solutions Gasketed Pressure Pipe shall be manufactured with nominal sizes of 30 and 36 with Dimension Ratios (DR) 18, 25, 32.5 or 41. Manufactured to meet the requirements of AWWA C905 and is certified to NSF-14. The PVC material used in the manufacture of our pipe meets the physical properties of PVC cell class 12454 as specified in ASTM D1784. Elastomeric gasket joints made for pipe meet or exceed the requirements of ASTM D3139. The steel-reinforced Double Seal Locked-In Rieber gaskets conform to the requirements of ASTM F477. Pipe Markings are as specified in AWWA C905 and NSF-14. Physical Properties of Cell Class 12454 Materials: Pipe shall be made of PVC plastic having a cell classification of 12454 as defined in ASTM D1784. ASTM Property: Test Minimum Tensile Strength, psi D638 7,000 Tensile Modulus, psi D638 400,000 IZOD Impact Strength D256.65ft-lbf/in. Deflection Temperature D648 158 F Pressure Ratings Pipe Psi DR18 235 DR25 165 DR32.5 125 DR41 100 Standard lay length is 20 feet

Gasketed AWWA C905 CIOD Pressure Pipe Gaskets The pipe utilizes a Double Seal Locked-In Rieber gasket system (DSLI) design which meets the requirements of ASTM D3139, Standard Specifications for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals. The gaskets are reinforced with a steel band and conform to the requirements of ASTM F477: Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe. Nominal Average Pipe Size Nominal Outside Pipe Size Diameter DR18 235 psi DR25 165 psi Wall DR32.5 (t) DR41 125 SDR psi 26 100 psi Average Bell Depth Insert Mark Line 30 32.000 1.778 1.280 0.985 0.780 14.775 14.075 36 38.300 n/a 1.532 1.178 0.934 15.825 15.075 SHORT FORM Specifications for Gasketed DR18, DR25, DR32.5 or DR41 Pressure Pipe Royal Municipal Solutions Gasketed Pressure Pipe shall be manufactured with nominal sizes of 30 and 36 to CIOD dimensions. Dimension Ratios (DR) 18, 25, 32.5 and 41 shall meet the requirements of AWWA C905 Polyvinyl Chloride (PVC) Pressure Pipe and Fittings and be certified to NSF-14. 2/1/15

Gasketed PS46 and PS115 Sewer Pipe F679 Sewer Specification Data Royal Municipal Solutions Gasketed Sewer Pipe shall be manufactured with nominal sizes of 30 and 36 to CIOD dimensions. Pipe Stiffness of 46 psi and 115 psi meet the requirements of ASTM F679 and are certified to NSF-14. The PVC material used in our pipe meets the physical properties of PVC cell class 12364 as specified in ASTM D1784. Elastomeric gasketed joints made for pipe meet or exceed the requirements of ASTM D3212, with internal hydrostatic pressure tested to 10.8 psi. The steel-reinforced Double Seal Locked-In Rieber gaskets conform to the requirements of ASTM F477. Pipe Markings are as specified in ASTM F679 and NSF-14. Physical Properties of Cell Class 12364 Materials: Pipe shall be made of PVC plastic having a cell classification of 12364 as defined in ASTM D1784. ASTM Property: Test Minimum Tensile Strength, psi D638 6,000 Tensile Modulus, psi D638 440,000 IZOD Impact Strength D256.65ft-lbf/in. Deflection Temperature D648 158 F Standard lay length is 14 feet

Gasketed PS46 and PS115 Sewer Pipe Gaskets The pipe utilizes a Double Seal Locked-In Rieber gasket system (DSLI) design which meets the requirements of ASTM D3212, Standard Specifications for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals. The gaskets are reinforced with a steel band and conform to the requirements of ASTM F477: Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe. Nominal Pipe Size Avg Outside Diameter PS46 PS115 Average Bell Depth Insert Mark Line 30 32.000 0.853 1.148 14.775 14.025 36 38.300 1.021 1.373 15.825 15.075 SHORT FORM Specifications for Gasketed PS46 and PS115 Sewer Pipe Royal Municipal Solutions Gasketed Sewer Pipe shall be manufactured with nominal sizes of 30 and 36 to CIOD dimensions. Pipe Stiffness 46 psi and 115 psi shall meet the requirements of ASTM F679, Type PSM Polyvinyl Chloride (PVC) Sewer Pipe and Fittings and be certified to NSF-14. 2/1/15

Large Diameter PVC Water & Sewer Pipe 30 & 36 Loading Information Gasketed PS 46 and PS 115 Sewer Pipe (F679) Nominal Item Bundle Truck Pipe Size Number Description Pcs Feet Load Feet Pieces 30" 5375725 DR26 HW GSK 30IN X 14FT SWR GN 3 42 6 252 18 36" 5375733 DR26 HW GSK 36IN X 14FT SWR GN 2 28 6 168 12 30" 5375776 DR35 GSK 30IN X 14FT SWR GN 3 42 6 252 18 36" 5375784 DR35 GSK 30IN X 14FT SWR GN 2 28 6 168 12 Gasketed AWWA CIOD Water Pipe (C905)* Nominal Item Bundle Truck Pipe Size Number Description Pcs Feet Load Feet Pieces 30" 5375750 C905 DR18 GSK 30IN X 20FT BL 3 60 4 240 12 30" 1468641 C905 DR25 GSK 30IN X 20FT BL 3 60 4 240 12 30" 1478874 C905 DR32.5 GSK 30IN X 20FT BL 3 60 4 240 12 30" 1468650 C905 DR41 GSK 30IN X 20FT BL 3 60 4 240 12 36" 1468676 C905 DR25 GSK 36IN X 20FT BL 2 40 4 160 8 36" 1468684 C905 DR32.5 GSK 36IN X 20FT BL 2 40 4 160 8 36" 1468692 C905 DR41 GSK 36IN X 20FT BL 2 40 4 160 8 * Also available in Green as MTO Made in USA 2/1/15