Basic Concepts of Ventilation Design



Similar documents
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

AIR SYSTEM BASICS. form the groundwork for the design, installation, operation, troubleshooting of these systems. Air duct Manometer

Fan Applications & System Guide

HVAC Calculations and Duct Sizing

Building Performance Solutions HVAC Design Guide, 2007

VAV Laboratory Room Airflow The Lowdown on Turndown

Chapter 3.5: Fans and Blowers

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

HVAC - How to Size and Design Ducts

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Chapter 12 Industrial Ventilation

Balancing of a water and air system

Principles of Ventilation. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

TABLE OF CONTENT

Duct Design. Presented by Dave Janquart

IDES-EDU. Educational Package Ventilation. Lecture 8: Sizing mechanical ventilation systems IEE/09/631/SI

Ventilation Standard For Health Care Facilities

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

Fan Performance By: Mark Stevens AMCA International Deputy Executive Director Technical Affairs

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation

Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program

How to Measure HVAC System Airflow

A P P L I C A T I O N S G U I D E. Duct Application Smoke Detectors

NFPA Combustible Dust Compliance and the Industrial Ventilation System

Averaging Pitot Tubes; Fact and Fiction

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

OSHA and Welding Exhaust

Dual Maximum VAV Box Controls

SAM HOUSTON STATE UNIVERSITY

Essam E. Khalil

Characteristics of Evaporators

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Technical Information

HVAC Basic Science - System Capacity

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

CONTROL VALVE PRESSURE DROP AND SIZING

PANDA SPRAY BOOTH FILTER INFORMATION

Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Air Conditioning Clinic

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Design Calculation or Analysis Cover Sheet. Complete only applicable items M8C-VCTO B

ANSI/AHRI Standard 880 (I-P) with Addendum Standard for Performance Rating of Air Terminals

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

SPECIAL APPLICATIONS

Duct Smoke Detectors

The New Data Center Cooling Paradigm The Tiered Approach

Not All 3A Recovery Wheels Limit Contaminant Transfer

THE PSYCHROMETRIC CHART AND ITS USE

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

CO MPa (abs) 20 C

Kitchen Ventilation Systems: Part 2 Providing Adequate Makeup Air

Exhaust Calculation Booklet

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Flexibility, Efficiency In San Antonio Arena

HVAC FORMULAS. TON OF REFRIGERATION - The amount of heat required to melt a ton (2000 lbs.) of ice at 32 F. 288,000 BTU/24 hr. 12,000 BTU/hr.

AABC Specifications for Testing and Balancing HVAC Systems

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

How To Design A Gas Dryer

Acoustical Design Guidelines for HVAC Systems in Schools

Geismar Site Reviewed: 07/05/16 Effective: 07/05/16 Supersedes: 08/04/14 Preparer: Owner: Approver: S/IH Team Leader S/IH Team Leader Manager LA Hub

= 800 kg/m 3 (note that old units cancel out) J 1000 g = 4184 J/kg o C

HVAC Systems: Overview

Welcome. Green HVAC Ductwork Done Right! John Reints, PE Eugene Smithart, PE

Flow Measurement Options for Pipeline and Open Channel Flow

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

STEAM TURBINE 1 CONTENT. Chapter Description Page. V. Steam Process in Steam Turbine 6. VI. Exhaust Steam Conditions, Extraction and Admission 7

Centrifugal Fans and Pumps are sized to meet the maximum

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

Pump Formulas Imperial and SI Units

Mechanical and Natural Ventilation

A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW ASME Fluids Engineering Division Summer Meeting

85 F 80 F 50% 75 F 70 F 73.0/ F 10% Figure 1

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice

High Altitude HVAC. Silvertip Integrated Engineering Consultants

Appendix 4-C. Open Channel Theory

HVAC Systems in Schools & Commercial Buildings and Radon

Healthcare Solutions Room Pressure Monitors and Controls

FIRE DAMPER APPLICATION GUIDE

Air Filtration for. Indoor Firing Ranges

Experiment 3 Pipe Friction

Sustainable Smart Laboratories

DESIGN OF GREASE FILTER EQUIPPED KITCHEN EXHAUST SYSTEMS

High Efficiency Particulate Air (HEPA) Filter Velocity Reduction Study

HVAC Air Systems. Recirculation Air System Types

Transcription:

Building Design and Engineering Approaches to Airborne Infection Control Basic Concepts of Ventilation Design Jack Price

General Principles of Ventilation Introduction Need for ventilation: Comfort Contamination Control both maintain healthy work environment

General Principles of Ventilation Office buildings ----- In-door air quality Occupational exposure ---- OSHA Environmental releases ---- EPA

General Principles of Ventilation Regulatory Agencies (compliance concerns) Federal State Local Good Practice Standard of care (industry standards ANSI, ASME, etc.) Work productivity Process control

Types of Systems Supply Temperature & Humidity Replacement (make-up air) Return (recirculated air) Exhaust General (dilution) Local Control (hoods)

HVAC Systems Air Handling System with Economizer Air Balance in a Conditioned Space

Design Concerns Temperature Pressure Air Contaminants Work Practices Product Protection Worker Protection Building Codes Equipment Selection Energy Conservation Maintenance Security Expansion

Patient Isolation Room with HEPA Exhaust Filtration

Air Conditioning System Water and Refrigeration Circuits

Factors in the Perception of Air Quality

Conversion Factors Quantity To Convert Into Multiply By: Volumetric cubic feet/minute cubic meters/second 4.719 x 10-4 Flow (ft 3 /min) (m 3 /sec) Velocity feet/minute meters/second 0.00508 (fpm) (m/s) Pressure inches water Pascals 249.1 (in w.g.) (Pa)

Conservation of Mass 1 velocity = 50 FPM Hood 2 velocity = 3000 fpm Air Flow Duct Flow rate at point 1 is called Q 1 and is equal to Q = V. A Where flow rate at point 2 which is called Q 2 Q = Volumetric Flow Rate, ft 3 /min V = Air Velocity, ft/min or fpm A = Cross Sectional Area, ft 2 or SF

Conservation of Mass Q = V. A 8 inch duct 1 12 inch duct 3 6 inch duct 2 Q 1 + Q 2 = Q 3 V 1 A 1 + V 2 A 2 = V 3 A 3

AIR FLOW At standard temperature and pressure (STP): * 1 atmosphere & 70 o F * The density of air is 0.075 lb m /ft 3 Air will flow from a higher pressure region to a lower pressure region Three Different Types of Pressure Measurements * Static * Velocity * Total *

Types of Pressure Measurements Static Pressure (S P ) potential energy can be + or bursting or collapsing measured perpendicular to flow Velocity Pressure (V P ) kinetic energy accelerates from 0 to some velocity Exerted in direction of flow always + Total Pressure (T P ) combined static & velocity components can be + or - measure of energy content of air stream Always decreasing as flow travels downstream thru a system only rising when going across a fan

TP = SP + VP TP _ + SP _ + VP +

Conservation of Energy TP = SP + VP or T P = S P + V P Energy losses: Acceleration of air Hood entry Duct losses: friction (function of system materials & design) Fitting losses: contractions & expansions T P1 = T P2 + h L now substitute T P = S P + V P S P1 + V P1 = S P2 + V P2 + h L

Hood Bench Grinder Pressure Graphs for TP, SP, and VP

Velocity Pressure & Velocity V = 1096 (V P /p) 0.5 where p = air density @ STP p = 0.075 lb m /ft 3 V = 4005 (V P ) 0.5 Velocity pressure is a function of the velocity and fluid density. Velocity pressure will only be exerted in the direction of air flow and is always positive.

Bench Grinder Exhaust Ventilation 1 Duct diameter = 3 inches Area = 0.0668 ft 2 2 3 Q 1 = Q 2 If Q desired is 300 cfm Then Q = V A V = Q A V = (300) / (0.0068) V = 4490 fpm If there are no losses from the grinder hood entry then: SP 1 + VP 1 = SP 2 + VP 2 but: SP 1 = 0 and VP 1 0 we then have: 0 = SP 2 + VP 2 or -VP 2 = SP 2

Bench Grinder Exhaust Ventilation 1 Duct diameter = 3 inches Area = 0.0668 ft 2 V = 4490 fpm 2 3 If there are no losses from the grinder hood entry then: SP 1 + VP 1 = SP 2 + VP 2 but: SP 1 = 0 and VP 1 0 we then have: 0 = SP 2 + VP 2 or SP 2 = (-VP 2 ) from V = 4005 (VP) 0.5 VP 2 = (4490/4005) 2 VP 2 = 1.26 in w.g. then: SP 2 = (-VP 2 ) SP 2 = -1.26 in w.g.

Bench Grinder Exhaust Ventilation 1 SP h Duct diameter = 3 inches Area = 0.0668 ft 2 V = 4490 fpm 2 3 However there are losses thru the grinder hood entry SP 2 = - (VP 2 + h e ) where h e is the energy loss of the hood entry Static pressure (SP) must decrease due to acceleration of air up to the duct velocity F h is defined as the energy loss factor (for that hood design) Energy losses will be measured as a function of the velocity pressure in the system h e = (F h ) (VP) Now we define the static pressure at the hood as SP h SP h is also called the hood static suction and is the absolute value of SP 2

Bench Grinder Exhaust Ventilation 1 S Ph Duct diameter = 3 inches Area = 0.0668 ft 2 V = 4490 fpm Now add the hood entry loss: 2 3 SP h = VP 2 + h e = VP 2 + (F h ) (VP 2 ) Assume that the hood energy loss factor for this hood is 0.40 SP h = 1.26 + (0.40) (1.26) = 1.76 in w.g.

Flanged Inlet with Fd = 0.49

Flanged Inlet with F d = 0.49

Hood Entry Coefficients Actual Flow C e = Hypothetical Flow no losses (4005) (VP) 0.5 (A) (VP) 0.5 C e = = (4005) (SP h ) 0.5 (A) (SP h ) 0.5 C e = (VP/SP h ) 0.5

Hood Entry Coefficients C e = (VP/SP h ) 0.5 Typical values for C e are known for some hoods. For the bench grinder hood with a straight take-off : C e = 0.78

Example Problem What static pressure (SP h ) should be set at the bench grinder hood to maintain a duct velocity of 4000 fpm if the take-off duct size is 4 inch diameter? What is the volumetric flow rate?

Example Problem V = 4000 fpm Q = VA = 4005(A)(VP) 0.5 Q = VA = 348 cfm A for 4 inch duct diameter = 0.087 ft 2 C e bench grinder hood = 0.78 C e = (VP/SP h ) 0.5 = 0.78 (VP/SP h ) = (0.78) 2 V = 4005 (VP) 0.5 (VP) 0.5 = (4000)/(4005) VP = 0.998 in w.g. SP h = VP/(0.78) 2 = (0.998)/(0.608) = 1.64 in w.g. 1.64 in w.g.

Air Flow Characteristics See Industrial Ventilation Manual notes Blowing vs. Exhausting

Air Flow Characteristics Exhaust Hoods Capture Velocity From Dalla Valle s empirical work V (x) = Q/ (10 x 2 + A)

Capture Velocity V (x) = Q/ (10 X 2 + A) Capture velocity is only effective in the immediate vicinity of the hood Room supply air (makeup air) discharge can influence effectiveness of hood capture

Questions?

In-Place Filter Testing Workshop Ventilation Systems: Operation and Testing

HVAC Systems

HVAC Systems Air Handling System with Economizer Air Balance in a Conditioned Space

Questions?