TSA - Swirl Diffuser. Halton TSA. Swirl Diffuser



Similar documents
WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

DSRQ - DSRSQ - DSRSQ-THERM

How To Make A Supply Air Ceiling

Swirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:

Basic Selection & Proper Application of Overhead Air Distribution Devices

Laminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) Telefax +44(0)

Supply air diffuser ROKA/RPKA

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

plenum slot diffusers

HVAC air curtains. Type InduAir

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

Installation, operation and maintenance manual TX 35A

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

Operating Instructions. Room temperature controller

HDA

Radiant Temperature Sensor TY7321

HERZ-Thermal Actuators

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

IH E Sigma Island 90

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Under sill units. Type FSL-B-ZAS

Grilles & Diffusers Series LFP Incorporating

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles

CELO5. User & Installation Manual.

SERVER ROOM CABINET INSTALLATION CONCEPTS

UDSA - UDSBD unit heater

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

PIEZOMETER AIRFLOW MEASURING RING

Butterfly Valves PN 6/10/16 for flanged connection

Technical catalogue convectors POLAND 2012

RY2 miniature industrial relays

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

CONTROL/SLAVE Zone. Zone damper for Swegon s WISE System for demand-controlled ventilation

HVAC Systems: Overview

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

LAMINAR FLOW CABINETS

ELECTRIC CENTRAL HEATING FLOW BOILER

Zehnder Focus 200. Ventilation device

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

Section 5: Machine Overview

Displacement ventilation

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

AMD-33 Air Measuring Station with VCD-33 Control Damper

How To Drive A Compact Serie 1

SERIES L. Fineline & Broadline. Linear Strip Grilles GRILLES 12

Cooktop Low-Profile Ventilation Hoods

SECTION EG. Engineering Guide Air Distribution. Please refer to the Price Engineer s HVAC Handbook for more information on Air Distribution.

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

How To Install A Perfect 16 Id Series Filter System

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

Miniatur Radial Gebläse mit integrierter Elektronik Miniature Radial Blower with integrated electronic

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

General Information... 2

SMS 4 / SMS 5 safety mat Product information

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Air Comfort. Technical Catalogue > Roof Fan STOF

Operating Instructions Bedienungsanleitung Mode d emploi

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

CE6500 Energy Recovery Ventilator

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

Telefon (+45) Telefax (+45) Installation and operating manual

Direct steam injection humidifiers

Physics 101 Hour Exam 3 December 1, 2014

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

POWER TRIM 5 F AUTO TRIM AND AUTO TRIM

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Development of Ventilation Strategy in Diesel Engine Power Plant by Using CFD Modelling

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Type overview. Technical data

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

INSTALLATION AND SERVICE MANUAL

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

Operating Instructions Air Conditioner

INFRARED QUARTZ WALL HEATER

User s Manual. Copyright 2014 Trick Technologies Oy

DUCT SYSTEM DESIGN CONSIDERATIONS Part 1

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

GF SERIES 1-TANK/2-TANK ELECTRIC FRYER USER S MANUAL

Transcription:

Halton TSA Swirl Diffuser Horizontal radial or alternatively vertical compact swirl jet air supply, also suitable for heating applications Also well suited to large and high spaces Supply air pattern can be adjusted either manually or controlled by actuator High induction swirl jet ensures efficient mixing and fast reduction of air velocity Installation using plenum or directly to ductwork Accessories Balancing plenum with adjustment function (PLC) or also with measurement function (TRI) Actuator (with 24 VAC power supply and proportional 0 10 VDC control signal or alternatively selfactuating wax-bulb) for the direction of airflow pattern MATERIAL AND FINISHING PART MATERIAL NOTE Casing Steel Deflector ring or cylinder Steel Front vane panel Steel Finishing Painted White RAL 9010 Special colours available 1

QUICK SELECTION Pa 1200 1440 1800 2160 2640 3240 4200 5400 7200 9000 10800 13200 16800 qv l/s 100 120 150 180 220 270 350 450 600 750 900 1100 1400 m 3 /h 360 432 540 648 792 972 1260 1620 2160 2700 3240 3960 5040 TSA-250(R) LpA 23 29 37 45 54 DPst 19 27 42 60 90 DPtot 21 30 47 68 102 Ld 2,2 2,4 2,6 3,0 3,4 Lmin 2,6 3,4 4,8 6,2 8,0 L0.2 2,3 2,8 3,4 4,2 5,2 TSA-315(R) LpA 23 28 35 43 55 DPst 14 20 30 46 77 DPtot 16 23 35 53 89 Ld 2,4 2,6 3,2 3,4 4,2 Lmin 3,4 4,4 6,0 7,8 10,6 L0.2 2,8 3,4 4,2 5,2 6,8 TSA-400(R) LpA 25 34 43 55 DPst 16 27 45 79 DPtot 19 32 52 93 Ld 3,0 3,6 4,2 5,0 Lmin 5,6 8,0 10,8 15,0 L0.2 5,0 6,4 8,2 11,0 TSA-500(R) LpA 26 36 45 52 DPst 17 30 47 68 DPtot 20 36 56 80 Ld 3,2 4,0 4,8 5,4 Lmin 8,2 11,6 15,0 18,4 L0.2 6,0 8,2 10,2 12,2 TSA-600(R) LpA 22 29 35 42 52 DPst 11 17 25 37 60 DPtot 13 21 30 45 73 Ld 3,0 3,6 4,2 5,0 5,8 Lmin 8,8 11,4 14,2 17,8 23,2 L0.2 6,4 8,0 9,6 11,8 15,0 LpA values presented with room attenuation 4 db (red 10m 2 - sab). When using room attenuation 8 db (red 25m 2 - sab): LpA - 4dB. Pa LpA DPst Supply air cooling capacity, W A-weighted sound pressure level, reduced by total equivalent absorption surface of 10m 2, db(a) red 10m 2 - sab Static pressure drop, Pa DPtot Ld Lmin Total pressure drop, Pa Distance from the supply unit, at which air jet detaches from ceiling, m Minimum distance between central lines of two supply units, m (V3 = 0,25m/s at 1.8m height) L0.2 Isotermal throw length, m when residual velocity of supply air jet 0,2 m/s Room temperature (Tr) = 24 C Supply air temperature (Ta) = 14 C Room height = 2,8 m 2

QUICK SELECTION Pa 1440 1800 2160 2640 3120 3600 4200 4800 5400 6000 7200 9000 10800 13200 15600 qv l/s 120 150 180 220 260 300 350 400 450 500 600 750 900 1100 1300 m 3 /h 432 540 648 792 936 1080 1260 1440 1620 1800 2160 2700 3240 3960 4680 TSA-250(C) LpA 22 30 37 46 53 DPst 22 35 50 75 104 DPtot 26 40 58 87 121 L0.2 2,8 3,6 4,4 5,6 6,8 TSA-315(C) LpA 17 22 28 34 39 44 49 53 DPst 12 17 26 36 48 65 85 108 DPtot 14 20 30 43 57 77 101 128 L0.2 2,4 3,0 4,0 4,8 5,6 6,8 8,0 9,0 TSA-400(C) LpA 19 23 28 33 37 42 49 DPst 12 16 22 28 36 44 64 DPtot 15 19 26 34 44 54 78 L0.2 3,0 3,6 4,2 5,0 5,8 6,6 8,2 TSA-500(C) LpA 21 24 28 33 41 48 DPst 10 13 16 23 35 51 DPtot 12 16 20 28 44 63 L0.2 2,8 3,2 3,8 4,6 6,2 7,6 TSA-600(C) LpA 22 29 34 41 47 DPst 9 14 20 30 42 DPtot 11 17 25 37 52 L0.2 2,6 3,4 4,2 5,2 6,4 LpA values presented with room attenuation 4 db (red 10m 2 - sab). When using room attenuation 8 db (red 25m 2 - sab): LpA - 4dB. Pa LpA DPst Supply air cooling capacity, W A-weighted sound pressure level, reduced by total equivalent absorption surface of 10m 2, db(a) red 10m 2 - sab Static pressure drop, Pa DPtot Ld Total pressure drop, Pa Distance from the supply unit, at which air jet detaches from ceiling, m L0,2 Isotermal throw length, m when residual velocity of supply air jet 0,2 m/s Room temperature (Tr) = 24 C Supply air temperature (Ta) = 14 C Room height = 2,8 m DIMENSIONS NS ØD ØW H Ø D 250 249 382 221 315 314 475 233 176 H 400 399 593 246 10 500 499 735 264 630 629 917 286 Ø W TSA with electrical actuator Ø D NS ØD ØW H H3 250 249 382 221 430 315 314 475 233 459 H3 400 399 593 246 486 500 499 735 264 499 176 H 630 629 917 286 524 10 Ø W TSA with wax-bulb actuator Ø D NS ØD ØW H H2 250 249 382 221 273 315 314 475 233 302 H2 176 H 400 399 593 246 329 500 499 735 264 342 10 630 629 917 286 367 Ø W 3

Compact jet Radial Jet Function The TSA is a high induction swirl diffuser with an adjustable flow pattern. The horizontal radial swirl jet is used mainly in cooling applications that use cool supply air or for ventilation with isothermal supply air. The vertical compact swirl jet with warm supply air is used in heating applications. Adjustment of the supply air pattern is effected by moving the internal adjustment element (cylinder). It is also possible to change from cooling mode to heating mode by adjusting the flow pattern using an electric or wax bulb actuator. The recommended maximum temperature differences between room and supply air temperatures are +15 C for heating and -15 C for cooling applications. Product models TSA with electric actuator Siemens GDB161.2E/HA actuator with 24 VAC power supply and proportional 0 10 VDC control signal TSA with wax-bulb actuator TSA can be equipped with a wax-bulb actuator, which work without any power supply. The cylinder position changes according to the temperature of supply air. The temperature range of the wax-bulb actuator is about 20 C to 27 C. The time taken to change from radial to compact jet (or the other way around) is 10-20 minutes. When warm air is supplied the piston of the wax bulb actuator keeps moving until the TSA supply air pattern is vertical. When cold air is supplied, the TSA supply air pattern is changed back to horizontal by means of a spring. 4

Installation The diffuser is connected either directly to the duct by screwing or riveting or alternatively to TRI or PLC balancing plenum. The front vane panel can be reattached Remove the screws through the front vane panel (sizes 250 and 315) or between the cylinder and casing (sizes 400, 500 and 630), turn and hold the front vane panel to remove. Installation with plenum TSA with TRI plenum TSA ØD1 TRI H1 ØW1 250 200 TRI-200-250 390-535 310 315 250 TRI-250-315 465-610 400 400 315 TRI-315-400 525-670 500 TSA with PLC plenum Take care during installation to ensure that the cylinder can move freely and that the actuator has adequate installation space. There should be at least 50 mm clearance space above the top of the device when the cylinder is in the lowest position. The connection and fixing rivets or screws may not be located more than 50 mm below the upper edge of the diffuser. TSA ØD1 PLC H1 ØW1 500 500 PLC 500 810-950 620 630 630 PLC 630 850-990 785 It is recommended that the distance between the PLC plenum and TSA sizes 500 and 630 is at least 1xD to ensure proper diffuser operation. A minimum safety distance upstream of the diffuser of 3xD is recommended. Ensure that the actuator has adequate installation space when installed in TRI plenum. It is recommended to install the collar outwards. H1 H The technical performance for the combination of supply air diffuser and TRI plenum is presented separately for the two different installations. See HIT Design software. 0 10 Ø W1 Wiring and DIL switches DIL switches: 1. Automatic adaptation of limited movement length to 0-10 VDC control signal 2. Direction of shaft movement based on 0-10 VDC control signal 3. Feedback signal 5

Adjustment CODE DESCRIPTION 1 Control knob 2 Casing 3 Front vane panel 4 Cylinder Throw pattern adjustment The supply air jet is adjusted by changing the position of the cylinder. When you turn the knob clockwise the throw pattern is changes from radial to compact. Pass the tubes and control spindle through the front vane panel. Measure the differential pressure using a manometer. The flow rate is calculated using the formula below. q v = k * p m Adjust the airflow rate by rotating the control spindle until the desired setting is achieved. Replace the tubes and spindle in the plenum. Airflow adjustment It is not possible to adjust the airflow in TSA itself. In order to enable airflow adjustment and measurement of airflow rate it is recommended that you connect the diffuser TSA 250, 315 and 400 to the TRI balancing plenum. The supply flow rate is determined by using the measurement and adjustment module MSM. 6

Pressure drop, throw pattern and sound data Supply, radial jet, ceiling installation flush to the ceiling TSA-250, TSA-315, TSA-400 TSA-500, TSA-630 Selection example : Requirements : qv = 350 l/s Selection : TSA-400 LpA < 35 db(a) LpA = 34 db(a) L0,2 < 8,0 L0,2 = 8,0 Horizontal jet DPtot = 27 Pa SOUND LEVEL DATA Note : For exposed installation horizontal the throw pattern can be reduced by approximately 30 %, of the value given in the diagram. With isothermal air, the throw pattern can be calculated for other terminal velocity by using correction factor : L0.3 = L0.2 x 0.67 L0.4 = L0.2 x 0.5 With non-isothermal air, the throw pattern changes due to air density. Please refer to next page or to the Halton HIT. CD-rom calculation program. Radial Jet qv DPst DPtot F (Hz) LpA NR NC (l/s) (m 3 /h) (Pa) (Pa) 125 250 500 1000 2000 4000 8000 [db(a)] TSA-250(R) 108 389 21 24 29 26 26 26 19 15 15 25 22 20 124 446 28 32 32 29 29 31 26 20 18 30 27 25 141 508 37 42 36 32 32 36 33 25 21 35 32 31 160 576 47 54 39 35 35 41 39 30 23 40 38 36 TSA-315(R) 163 587 17 19 29 27 28 25 17 13 14 25 21 19 189 680 22 26 32 30 31 31 24 17 17 30 27 25 217 781 30 34 36 33 34 36 31 22 21 35 32 31 248 893 39 45 39 35 36 41 38 26 24 40 37 36 TSA-400(R) 271 976 16 19 28 26 29 24 15 14 15 25 21 19 316 1138 22 26 33 30 32 31 22 19 18 30 27 25 364 1310 29 34 37 33 36 37 28 24 22 35 33 31 414 1490 38 44 41 36 39 42 34 28 25 40 38 37 TSA-500(R) 433 1559 16 18 29 26 28 25 17 13 14 25 21 19 505 1818 21 25 33 29 31 31 24 19 18 30 27 25 583 2099 28 33 37 32 34 36 31 24 21 35 32 31 664 2390 37 44 40 35 37 41 38 29 24 40 37 36 TSA-630(R) 660 2376 13 16 29 26 28 25 16 12 14 25 21 19 776 2794 19 22 34 30 31 31 24 18 18 30 27 25 896 3226 25 30 37 33 34 36 31 23 21 35 32 31 1029 3704 33 39 41 36 37 41 37 28 24 40 37 36 LpA values presented with room attenuation 4 db (red 10m 2 - sab). When using room attenuation 8 db (red 25m 2 - sab): LpA - 4dB. NR/NC noise criteria 7

Pressure drop, throw pattern and sound data Supply, compact jet, ceiling installation TSA-250, TSA-315, TSA-400 TSA-500, TSA-630 Selection example : Requirements : qv = 350 l/s Selection : TSA-400 LpA < 35 db(a) LpA = 33 db(a) L0,2 < 16,0 L0,2 = 15,0 DPtot = 28 Pa Note : With non-isothermal air, the throw pattern changes due to air density. Please refer to next page or to the Halton HIT software. SOUND LEVEL DATA Compact Jet qv DPst DPtot F (Hz) LpA NR NC (l/s) (m 3 /h) (Pa) (Pa) 125 250 500 1000 2000 4000 8000 [db(a)] TSA-250(C) 130 468 26 30 29 26 26 23 22 18 17 25 21 19 149 536 34 40 32 29 29 29 28 22 18 30 28 25 170 612 45 52 35 32 33 34 34 26 20 35 34 31 192 691 57 66 37 35 36 39 40 30 22 40 39 37 TSA-315(C) 199 716 21 25 30 27 27 23 21 16 14 25 21 18 232 835 29 34 31 31 32 29 27 19 15 30 27 24 270 972 39 46 33 34 36 34 33 22 16 35 33 30 311 1120 51 61 35 37 40 39 39 25 17 40 38 36 TSA-400(C) 319 1148 18 22 29 26 29 22 20 17 17 25 20 19 370 1332 24 30 32 30 32 29 26 21 20 30 25 23 425 1530 32 39 34 33 35 35 32 25 22 35 31 30 481 1732 41 50 37 36 38 41 37 29 25 40 37 36 TSA-500(C) 458 1649 13 16 30 26 28 23 20 16 16 25 20 18 539 1940 18 23 33 29 31 30 26 21 19 30 26 24 628 2261 25 31 35 32 35 36 31 25 22 35 32 30 726 2614 33 41 38 35 38 41 37 29 25 40 37 36 TSA-630(C) 663 2387 11 14 30 26 28 23 20 15 16 25 20 18 783 2819 15 19 33 29 32 30 26 20 19 30 26 24 918 3305 21 26 36 32 35 36 31 25 22 35 32 30 1065 3834 28 35 38 36 38 41 37 29 25 40 37 36 LpA values presented with room attenuation 4 db (red 10m 2 - sab). When using room attenuation 8 db (red 25m 2 - sab): LpA - 4dB. NR/NC noise criteria 8

Servicing Remove the front vane panel and clean the diffuser by wiping it with a damp cloth, instead of immersing it in water. Option with balancing plenum Remove the measurement and adjustment module by pulling gently the shaft; (not the control spindle or measurement tubes!). Wipe the parts with a damp cloth, instead of immersing them in water. Remount the measurement and adjustment module by pushing the shaft until the module meets the stopper. Suggested specifications Product code TSA-D D = Connection size 250, 315, 400, 500, 630 Specifics and accessories CO = Colour W White X Special colour MO = Actuator type NA No actuator M2 24 VAC actuator, 0...10 VDC control signal M3 Wax-bulb actuator The diffuser shall consist of a frame with fixed internal profiled vane rings and a movable cylinder for throw pattern selection. The front vane panel, the movable cylinder and the frame shall be made of powder painted steel, with a white (RAL 9010) as standard colour. Code example TSA-250, CO=W,MO=NA Sub products The airflow pattern shall be adjustable automatically using an electrical or wax-bulb actuator, (in applications where both heating and cooling are required.) PLC TRI Plenum (Ceiling diffusers) Plenum (Diffusers) 9