Carbon Fiber Reinforced Polymer (CFRP) Laminates - Aslan

Similar documents
APE T CFRP Aslan 500

The Original Carbon Fiber Reinforced Polymer System

Fiberglass Rebar (GFRP Rebar)

ICS: Strengthening retrofitting of reinforced concrete structures by gluing of fibre reinforced polymeric fabrics (FRP fabrics)

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

USE OF CFRP LAMINATES FOR STRENGTHENING OF REINFORCED CONCRETE CORBELS

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

Strengthening of a Bridge Using Two FRP Technologies. Paolo Casadei, Nestore Galati, Renato Parretti and Antonio Nanni

Shear Strengthening. Sika CarboDur Composite Systems

Technical Notes 3B - Brick Masonry Section Properties May 1993

BEHAVIOR OF SHORT CONCRETE COLUMNS REINFORCED BY CFRP BARS AND SUBJECTED TO ECCENTRIC LOAD

SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP

beams columns blast walls slabs pipes protective coatings polymer concrete Solutions Looking for Problems...

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

STRENGTHENING AND LOAD TESTING OF THREE BRIDGES IN BOONE COUNTY, MO

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

CA-48 TECHNICAL SPECIFICATION

REVIEW OF STRENGTHENING TECHNIQUES USING EXTERNALLY BONDED FIBER REINFORCED POLYMER COMPOSITES

CFRP STRENGTHENING OF CIRCULAR CONCRETE SLAB WITH AND WITHOUT OPENINGS

FM FILM ADHESIVE

Construction. Structural Strengthening with SikaWrap Fabric Systems

Bonding Agents: The Good, the Bad, and What Works. Bond with Your Concrete

FLEXURAL BEHAVIOUR OF HYBRID FRP-UHPC GIRDERS UNDER STATIC LOADING

Rolla, Rolla, MO 65409, USA

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete

Repair of Fatigued Steel Bridge Girders with Carbon Fiber Strips

Condition assessment and repair of antenna towers concrete foundations

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

Strengthening and Repair of Reinforced Concrete Structures. Ian Wienholt Business Development Manager

SPECIAL NOTE FOR ASPHALT WATERPROOFING MIX FOR BRIDGE-DECK OVERLAYS AND ADJACENT APPROACHES

BRIDGE REHABILITATION TECHNIQUES

Matrix system with enhanced mechanical performance: new infusion system for wind energy applications enables lighter, longer, lower cost rotor blades

Stress Strain Relationships

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Product Data. HexPly 8552 Epoxy matrix (180 C/356 F curing matrix)

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Prestressed Concrete Pipe Fitness for Service and Repair

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Fire Damage Evaluation. Concrete Garage. Vehicular fires in parking garages are not an

Overview of Topics. Stress-Strain Behavior in Concrete. Elastic Behavior. Non-Linear Inelastic Behavior. Stress Distribution.

MATERIALS AND MECHANICS OF BENDING

ADHESIVE BONDING PERFORMANCE OF GA COATED 590 MPa TENSILE STRENGTH STEELS

SECTION 3 DESIGN OF POST- TENSIONED COMPONENTS FOR FLEXURE

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

Assistant Professor of Civil Engineering, University of Texas at Arlington

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

INVESTIGATION OF VISCOELASTICITY AND CURE SHRINKAGE IN AN EPOXY RESIN DURING PROCESSING

A JACKET FOR ALL OCCASIONS Newly developed system offers unique solution for quick retrofit of deteriorated columns

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

PRESTRESSED CONCRETE. Introduction REINFORCED CONCRETE CHAPTER SPRING Reinforced Concrete Design. Fifth Edition. By Dr. Ibrahim.

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps

Composite Design Fundamentals. David Richardson

Seismic Retrofit of Reinforced Concrete Beam- Column T-Joints in Bridge Piers with FRP Composite Jackets

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

September 1, 2003 CONCRETE MANUAL CONCRETE PAVEMENT REHABILITATION

The ACI 562 Repair Code

How To Repair A Steel Pier With A Watertight Frame

Rehabilitation of corroded pipelines and pipes with FibaRoll

NUMERICAL ANALYSIS OF GLULAM BEAMS WITHOUT AND WITH GFRP REINFORCEMENT

Concrete Repair. Applications and Procedures

Use of Strain Gauge Rosette to Investigate Stress concentration in Isotropic and Orthotropic Plate with Circular Hole

Methods for Seismic Retrofitting of Structures

Green Thread Product Data

ANALYSIS FOR BEHAVIOR AND ULTIMATE STRENGTH OF CONCRETE CORBELS WITH HYBRID REINFORCEMENT

SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR FLEXURE

How To Repair A Damaged Fiberglass

Section 5A: Guide to Designing with AAC

CHAPTER I. INTRODUCTION

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

Phosphoric Acid Anodized Aluminum Honeycomb

FIBERGLASS REINFORCED PLASTIC (FRP) PIPING SYSTEMS DESIGNING PROCESS / FACILITIES PIPING SYSTEMS WITH FRP

Experimental assessment of concrete damage due to exposure to high temperature and efficacy of the repair system

CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

Numerical modelling of shear connection between concrete slab and sheeting deck

A Decade of Performance of FRP-Repaired Concrete Structures

CYCOM 2040 EPOXY PREPREG

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

PRODUCT DATA SHEET PRODUCT DESCRIPTION. Compressive Strength (0 ) ETW (1) ASTM D ksi 1210 MPa

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

SC2000 CEMENT BONDING PROCEDURES

Index Series Prestressed Florida-I Beams (Rev. 07/12)

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

CARBON/DYNEEMA INTRALAMINAR HYBRIDS: NEW STRATEGY TO INCREASE IMPACT RESISTANCE OR DECREASE MASS OF CARBON FIBER COMPOSITES

Type of Force 1 Axial (tension / compression) Shear. 3 Bending 4 Torsion 5 Images 6 Symbol (+ -)

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

FRP Repair Methods for Unreinforced Masonry Buildings Subject to Cyclic Loading

HexWeb CR III Corrosion Resistant Specification Grade Aluminum Honeycomb

Structural Retrofitting Process and Techniques

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

Specification for Pipe Coating Repairs Offshore

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

Technical Data Sheet February 2014

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

Detailing of Reinforcment in Concrete Structures

Transcription:

Carbon Fiber Reinforced Polymer (CFRP) Laminates - Aslan 400 series November 10, 2011

Aslan 400 Carbon FRP Laminates are used to structurally strengthen existing concrete, wood, or masonry members in flexure and shear. The CFRP Laminate is a pre-cured plate with a surface texture on one face, which helps improve bond with the structural adhesives. Structures that are deficient due to either a structural flaw, deterioration or because of a change in use can often be brought to a useful capacity using. Externally bonded FRP strengthening is analogous to steel plate bonding. Successful implementation of CFRP plate bonding is dependent on proper surface preparation, leveling and bond of the structural adhesive to the concrete and CFRP plate interfaces. Externally bonded work best in overhead applications for flexural strengthening where sufficient bond and development lengths can be achieved. Since 1993, Hughes Brothers has been at the forefront of worldwide academic and industry efforts to define consensus FRP standards and methods. Hundreds of structures have extended service lives due to. Externally Bonded Structural Strengthening Flexural Strengthening of: - Bridge Decks - Parking Garages - Floor slabs Shear Strengthening Change of Use Situations Higher Loads Return Deteriorated Members to Capacity Additional Structural Capacity Without Additional Dead Weight Masonry Strengthening In Plane and Out of Plane Strengthening of Masonry Shear Walls Event Loading of Masonry Blast, & Seismic Restore Capacities of Cracked Masonry Benefits of Carbon FRP Laminate Furnished with guaranteed properties based on measured results. is manufactured in a controlled environment and not subject to vagaries of field wet lay-up systems. Furnished with one face prepared for bonding to adhesive. Much lighter weight than steel plate bonding Will not rust or corrode Can be used with multiple commercially available high strength adhesives. 2

Mechanical Properties Tensile, Modulus & Strain Width -in Width - mm Dimensions Thickness - in Thickness - mm Nominal Area Guaranteed Tensile Strength Ultimate Tensile Load Tensile Modulus of Elasticity Ultimate Strain mm 2 in 2 MPa ksi kn kips GPa psi 10 6 % 2 50 0.055 1.4 70 0.1102 2400 350 168 38.57 131 19 1.87% 4 100 0.055 1.4 140 0.2204 2400 350 336 77.14 131 19 1.87% Hughes Brothers reserves the right to make improvements in the product and/or process which may result in benefits or changes to some physical-mechanical characteristics. The data contained herein is considered representative of current production and is believed to be reliable and to represent the best available characterization of the product as of July 2011. Tensile tests per ASTM D3039. Design Tensile & Modulus Properties Tensile and Modulus Properties are measured per ASTM D3039, Standard Test Method for Tensile Properties of Polymer Matrix Composite Materials. The ultimate tensile load is measured and the tensile modulus is measured at approximately 10% to 50% of the ultimate load. The slope of the stressstrain curve is determined as the tensile modulus. Ultimate Strain is extrapolated from the ultimate load divided by the nominal area and modulus. The area used in calculating the tensile strength is the nominal cross sectional area. The Guaranteed Tensile Strength, f * fu is as defined by ACI 440.1R as the mean tensile strength of a given production lot, minus three times the standard deviation or f * fu = f u,ave 3σ. The Design or Guaranteed Modulus of Elasticity is as defined by ACI 440.1R as the mean modulus of a production lot or E f = E f,ave. Net Fiber Area vs. Measured Material Properties There is a great deal of confusion and debate over reporting material properties of FRP strengthening materials. The two methods used are: 1) Net Fiber Area and 2) Gross Laminate Area. Net Fiber Area is often used with field wet lay-up systems where the amount of fiber in an un-cured fabric mat is known but the final thickness of the cured composite with impregnated resin is unknown. The resin is thus excluded from the composite. The strands or fibers are impregnated with resin, cured and then tested in tension. The properties are calculated using the area of the fibers and the area of the resin is ignored. The Gross Laminate Area of an FRP system is calculated using the total cross sectional area of the cured composite including all fibers and resin. This gives the appearance that the material has a lower tensile strength. It is important to recognize that the stress is lower but with the larger area the loads are similar. Hughes Brothers reports all material properties based on the Gross Laminate Area method using actual production lot tests per ASTM D3039. Since the design procedures in consensus guides such as the ACI 440.2R limit the strain in the FRP material, the full nominal strength of the FRP is NOT used and should not be the basis of comparison between two FRP systems (from ACI 440.2R section 15.2, pg 43) 2011 3

Density Size Designation Unit Weight / length Size mm kg / m lbs / ft 2 50 0.1637 0.11 4 100 0.2976 0.20 Material Certs Material test certs are available for any production lot of Laminate. Transition Temperature of Resin - T g Known as the glass transition temperature or the temperature at which the resin changes from a glassy state and begins to soften. Tg = 230 F (110 C) Laminates with extensometer and after valid tensile test 4

Design Guidance h d b c ε c β 1 c γ fc neutral axis As h - c d - c ε s fs fs Af = n tf wf Reinforced Concrete Section ACI 440.2R Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures - Provides authoritative, consensus guidelines for the use of. ε fe ε bi Strain Distribution ffe = Ef ε fe Stress Distribution (Non-linear Concrete Stress Distribution) ffe = Ef ε fe Stress Distribution (Equivalent Fictitious Concrete Stress Distribution) ACI 440.7R Guide for the Design and Construction of Externally Bonded Fiber-Reinforced Polymer Systems for Strengthening Unreinforced Masonry Structures An ACI Emerging Technology Series document provides state of the art guidance for masonry strengthening with. FIB Task Group 9.3 bulletin 14 Externally bonded FRP reinforcement for RC Structures In Europe, the Federation Internationale du Beton FIB Task Group 9.3 has published a technical report Bulletin 14, which is a thorough guide for the design and installation of. CSA S-806 Design and Construction of Building Structures with Fibre-Reinforced Polymers The Canadian guideline includes provisions for externally bonded structural strengthening. 2011 5

Bond Critical Efficacy The effectiveness of externally bonded FRP strengthening is directly related to the bond interfaces between the concrete, adhesive and FRP. The typical failure mode is generally de-bonding rather than rupture of the FRP. For this reason, surface preparation, leveling of the substrate and caliber of the workmanship has much more influence on a successful outcome than with the NSM method. From ACI 440.2R-08 Handling and Installation is furnished in continuous coils that are 250ft in length. Do Not Shear FRP Laminates. When field cutting of Aslan 400 is necessary, use a grinder, carborundum or diamond blade. Carbon FRP is semiconductive and NOT appropriate for non-magnetic applications or in direct contact with dissimilar materials. 6

Installation of After assessment of the existing structure and design by a competent professional, installation of Aslan 400 is performed according to the following general outline. Concrete, masonry or wood surfaces must be sound and free of scale, mill or other surface contaminates. Externally Bonded Installation instructions Step #1: Surface preparation by sand or water blasting is performed to expose course and fine aggregate surfaces. Surface preparation should be in accordance with ACI 546R and ICRI 0370. Step #2: Perform bond pull-off tests of the concrete substrate soundness per engineers guidelines. Step #3: Measure evenness or levelness of the prepared surface. An uneven surface will result in premature peeling of the laminate under load. This is measured by placing a straight edge against the prepared surface. Uneven areas should be leveled with an appropriate leveling mortar or putty. Step #4: Before applying structural adhesive to the CFRP Laminate, the sanded or roughened side of the laminate is wiped with acetone or other solvent until any excess residue is removed from the carbon plate. Inadequate surface leveling Step #5: Prior to application of the structural adhesive to the substrate and laminate, appropriate climatic conditions are measured to ensure they are within the tolerance required by the structural adhesive. Step #6: Structural adhesive is applied to both the carbon and substrate surfaces. Step #7: The Laminate is carefully positioned and pressed in place using a hard rubber roller to achieve a void free bond line thickness between 0.07 (2mm) to 0.11 (3mm). Excess adhesive is then removed from the sides of the before it can cure. 2011 7

Step #8: If specified, the is coated with an epoxy coating or decorative elastic polymer. Step #9: To facilitate quality control inspection, test patches adjacent to the area being strengthened should be prepared simultaneously to each of the above operations. Bond pulloff tests can then be performed to validate proper installation. System ~ Approved Adhesives The following high strength structural adhesives are recommended for use. Pilgrim EM 5-2 Gel DeNeef Enforce CFL Gel SikaDur 30 Hughes Brothers Factory 8