FRP Repair Methods for Unreinforced Masonry Buildings Subject to Cyclic Loading

Size: px
Start display at page:

Download "FRP Repair Methods for Unreinforced Masonry Buildings Subject to Cyclic Loading"

Transcription

1 SP FRP Repair Methods for Unreinforced Masonry Buildings Subject to Cyclic Loading by P.B. Foster, J. Gergely, D.T. Young, W.M. McGinley, and A. Corzo Synopsis: Unreinforced masonry building specimens were evaluated under cyclic lateral loading. Various fiber reinforced polymer (FRP) composite configurations were used to repair and retrofit the masonry structures. In the first phase, three different composite systems were used to repair pre-damaged masonry structures. These systems included: a wet lay-up woven glass fabric; a near surface mounted (NSM) extruded carbon FRP plate; and a glass FRP grid attached via a high elongation polyurea resin. Retesting of the repaired structures revealed increases as much as 700% in terms of energy dissipation and 300% in terms of pseudo-ductility. The second phase involved retrofitting similar undamaged building specimens with FRP composites. Significant increases in strength, ductility and energy dissipation were observed. The seismic performance of each structure was increased with the addition of a minimal amount of composite material as compared to the unreinforced structures. Keywords: FRP; near surface mounted; repair; retrofit techniques; seismic loading; unreinforced masonry; wet lay-up 289

2 290 Foster et al. Peter B. Foster is a doctorate research assistant at the University of North Carolina at Charlotte. His Masters Thesis involved load testing a novel type of steel connection and has been involved in a multitude of research projects which included load testing bridges, structural insulated panels, FRP applications for concrete and masonry systems, as well as finite element studies. Janos Gergely is an associate professor at the University of North Carolina at Charlotte. He has worked extensively with FRP composites, and their applications to concrete and masonry structures and components. He has also been involved in studies focused on bridge performance and analysis. David T. Young is the chair of the Department of Civil Engineering at the University of North Carolina at Charlotte. He has been involved in a wide variety of research project involving masonry and concrete, FRP composites and structural insulated panels. His interests are in forensic engineering and NDE. W. Mark McGinley is a professor in the Department of Architectural Engineering at North Carolina A & T State University. His interests are in the use of FRP composites to enhance the performance of masonry structures. He has conducted a number of research investigations on masonry materials, components and systems. Anna Corzo is a graduate research assistant at North Carolina A & T State University and is working with Mark McGinley in developing an analytical model to predict the behavior of FRP reinforced masonry systems. RESEARCH SIGNIFICANCE The research presented herein describes a methodology for the repair and retrofit of unreinforced masonry (URM) buildings using fiber reinforced polymer (FRP) composites. This methodology can be directly applied to structures that have been damaged due to significant lateral loading or structures that are substandard and need to be retrofitted and, as seen in this paper, can significantly enhance the strength and performance characteristics of these structures. As compared to traditional repair/retrofit methods, this new methodology is appreciably more cost-effective as well as less intrusive. INTRODUCTION Fiber reinforced polymer (FRP) composites have been extensively investigated in the last decade and a half throughout the world. The interaction of FRP materials with concrete and masonry has been studied under a variety of loading conditions. With regard to masonry, FRP composites have been used to strengthen unreinforced masonry shear and flexural walls with resounding success. The extent of this research has been limited, with few exceptions, to component testing. The seismic capacity of unreinforced masonry (URM) shear walls is minimal. Experimental studies (Eshani et al., 1996) proved that using FRP composites could

3 FRPRCS enhance the seismic performance of unreinforced masonry shear walls. The dynamic response of URM shear walls has been investigated as well (Al-Chaar et al., 1999). In another study, the performance of URM shear walls subjected to cyclic lateral loads were greatly enhanced when CFRP composite laminates were used to retrofit the masonry components (Gergely et al., 2000). The capacity of unreinforced masonry flexural walls has been shown to have drastically increased by using FRP composites (Albert, Elwi and Cheng 2001). In this investigation, both glass and carbon FRP laminates were used. In a similar investigation, flexural walls strengthened with FRP materials resulted in significantly increased flexural capacities, provided that shear was controlled at the support (Hamoush et al., 2001). In a similar study, the capacities of GFRP flexural walls were compared to design equations that resulted in an overprediction of no more than 20% (Hamilton and Dolan, 2001). The performance of unreinforced masonry infill walls has been explored as well. The capacity and performance of these infill walls can be significantly enhanced by FRP composite retrofit (Silva et al., 2001). Infill walls, subjected to both on and off-axis loading, were shown to have moderate to significant strength increases when retrofitted with glass FRP (Hamid et al., 2005). However, few investigations focused on the entire masonry building system subjected to quasi-static lateral loading. One such project evaluated a full-scale masonry building system with flexible diaphragms, that utilized several different FRP composite laminates, as well as post-tensioning, to enhance the performance of the system (Moon et al., 2002). It was found that the system-wide performance was greatly enhanced under cyclic lateral loading. It has also been shown that the dynamic capacity of URM walls reinforced with FRP composites can be significantly improved with failure occurring in the masonry units, rather than the mortar joints (Marshall, Sweeney and Trovillion, 1999). In general, the experimental evaluation of full scale building models is quite expensive and testing of individual components seems to be a much more cost-effective solution. The results of these component tests, however, may be somewhat skewed in some instances and there may exist idiosyncrasies that may not be accurately captured by component testing. In a full scale building model, redistribution of lateral forces and changes in end conditions (i.e. fixed to cantilever) can be achieved when cracking occurs. These cannot be captured accurately with component testing. Also, with component testing, out-of-plane rotations may occur that would not normally occur in a full scale building model. It may be that component testing is applicable for obtaining general performance characteristics of a particular FRP system but, ultimately, the system must be implemented on a full scale structure to attain an accurate response. The goal of the present research was to investigate several repairs and retrofit methods for existing unreinforced masonry structures, with rigid diaphragms, subjected to quasi-static lateral loading. In support of this effort, large-scale structural tests were performed at UNC Charlotte, and the small component tests were performed at NC A&T.

4 292 Foster et al. EXPERIMENTAL DESIGN Several full-scale unreinforced masonry buildings were constructed. Due to size constraints that existed within the load frame, each structure was constructed with the dimensions 2.48 m (8 ) in height, 3.25 m (10 8 ) in width, and 4.47 m (14 8 ) in length (see Figure 1). The shear walls on each side were perforated with two 82 cm (32 ) wide standard doorway openings in two structures, resulting in a symmetric structural configuration. An asymmetric configuration was also tested, and in this case only one shear wall was perforated with the standard doorway opening. A rigid roof diaphragm, designed as a deep beam, was used to prevent any independent movement that may occur in the walls with a flexible diaphragm. This roof diaphragm was placed atop a mortar bed and secured to the structure utilizing 32 anchorage points evenly spaced around the perimeter of the bond beam. Dywidag Threadbar reinforcing bars were used to transfer the applied lateral load through the roof panel via a hydraulic piston. A gravity load simulator was used to apply a 667 kn (150 Kips) vertical load to the structure, simulating the weight of two additional floors. The loading mechanism was comprised of wide-flange steel members, and this simulator was designed such that the gravity load would be maintained under an applied cyclic lateral load, i.e. the entire gravity load system was allowed to translate, together with the building, under lateral load while maintaining the applied gravity load. This vertical load was monitored throughout the test both by the hydraulic system pressure transducer and by strain measuring instruments. Each masonry building was constructed atop reusable concrete foundations. These foundations had removable dowel bars that extended 41 cm (16 ) above the top of the foundation, and these bars were grouted in the masonry wall. The dowel bars were used to prevent any overturning or sliding that may have occurred at the foundation level, and forced the failure to occur in the shear wall panels. In addition to the bottom 41 cm (16 ), the top 20 cm (8 ) bond beam was also grouted with a 27.6 MPa (4000 psi) grout. This was done to allow anchorage for the roof diaphragm and foundation elements. The remainder of the masonry walls was ungrouted. The testing procedure for each structure was identical: after the 667 kn (150 Kips) gravity load had been applied, the lateral load was applied at a rate of 3.5 kn (800 pounds) per second, with a load step of 44.5 kn (10 Kips). Each load step was comprised of three push-pull cycles. In the first phase, after failure of the URM building was achieved, the lateral load was removed, followed by the release of the gravity load. Following the removal of the instrumentation, the structure was evaluated and an appropriate FRP composite repair technique was selected. Following the FRP repair, the structure was retested. In the case of the retrofitted structures (Phase II), the FRP composite was applied without pre-testing the building. During the loading process, an array of instrumentation was used, which included displacement transducers, strain transducers, strain gages, linear potentiometers, pressure transducers and load cells.

5 EXPERIMENTAL RESULTS FRPRCS CMU-Configuration I Two symmetric CMU structures were fabricated and tested in this configuration. Both structures, as previously stated, were unreinforced. One structure was damaged and subsequently repaired using a glass FRP composite system and retested. The second structure was retrofitted using an identical composite system, although the layout was altered. The performance of the unreinforced (baseline) structure remained linear until a lateral load level of approximately 267 kn (60 Kips) (see Figure 2). At this point, microcracking began to occur in the bed and head joints, which developed into a more extensive diagonal step cracking pattern as the load was increased. The cracking in the large pier was limited to the mortar joints, while in the small pier diagonal tension cracking was observed in the masonry units and the mortar joints. Failure occurred at an applied lateral load level of 400 kn (90 kips) with an associated lateral displacement of 6.35 mm (0.25 ). The damage associated with this load level and displacement was not catastrophic, and the structure continued to withstand the gravity load at failure. For both testing phases, the composite system used to strengthen the symmetric CMU building specimens was SikaWrap Hex 100G glass fiber woven fabric in conjunction with Hexcel 306 resin. This is an externally applied wet lay-up GFRP composite system that can be applied to one or both surfaces of a wall, depending on the site conditions and the performance requirements. In this project, all the FRP systems were applied only to the exterior surface of the shear walls. The composite layout for the repaired structure was determined using a strutand-tie model. The strut and tie model was developed from a simple free body diagram (FBD) as seen in Figure 3. In this figure, only the FBD for the large pier is shown. The axially applied load, P, and the applied lateral load, V, are known and this allows for the determination of the internal forces of the pier. The axial load, P, as previously specified was 667 kn (150 Kips) distributed evenly along the length of the shear walls. The applied lateral load was set to a level of kn (175 kips) with an equal dispersion between the two shear walls. Distribution factors, based on rigidity calculations, were used to determine the lateral force applied to each pier. The internal shear forces, V1 and V2, characterize the shear strength of the GFRP laminate as determined through small component testing and the additional shear capacity achieved through friction and the applied axial load, respectively. The tensile forces, T and T2, represent solely the tensile strength of the GFRP laminate as the damaged unreinforced masonry substrate cannot hold significant tensile forces. From this, the quantity of GFRP composite needed to maintain rotational equilibrium was determined and yielded the number of 30 cm (12 ) layers needed to repair the structure. It was determined that two mm (0.04 ) thick layers would be used throughout the majority of the structure, with the exception of the flexure-dominated small piers, where three vertical layers were used (see Figure 4), in addition to the diagonal laminates. The composite layout for the retrofitted symmetric CMU structure was determined using a similar procedure although the laminate

6 294 Foster et al. configuration differed. It was comprised of only vertical layers, a somewhat less efficient but simpler layout to implement. The layout called for three 25 cm (10 ) strips in the large piers, evenly spaced across the pier, and two in the small piers. Each laminate was comprised of two layers of glass fiber. As expected, the performance of the repaired structure was far superior to the unreinforced test. The lateral load reached a maximum level of 667 kn (150 kips), and the associated displacement in the push cycle had a magnitude of mm (0.88 ). At failure, the FRP laminate received little to no damage. The majority of the damage occurred in the large pier and was localized to the bottom of the doorway, as anticipated. The mode of failure was masonry substrate failure. The nature of the composite layout was such that significant forces from the flexural and shear reinforcement were transmitted through this region in a pull cycle, during which the structure failed. The tensile forces in the diagonal and vertical composite laminates created a moment about the dowel bar embedded with the CMU, a load which the masonry units could not withstand. A possible way to avoid this would be to wrap this region with the same fabric, or provide some other anchoring means to prevent the splitting that occurred. Later tests proved that when this region is protected, the structure will likely reach higher lateral loads. The retrofitted CMU structure shown in Figure 5 performed well under the cyclic lateral load. The structure resisted approximately 35% more load than the URM baseline building, with a maximum applied load of 547 kn (123 kips). The displacement accompanying that load level was 12.2 mm (0.48 ) in push. Surprisingly, the stiffness of the structure did not significantly degrade until the lateral load reached a level of 400 kn (90 kips). The mode of failure observed was diagonal tension cracking in all piers. Hysteretic and backbone curves were developed for the undamaged, repaired and retrofitted tests using guidelines set forth be the Federal Emergency Management Agency Document 356 (FEMA, 2000). The envelope created defines the general behavior of the structure in terms of applied load versus displacement. A comparison of the backbone curves from the unreinforced and the repaired tests shows that the FRP reinforced system had significantly more lateral capacity, but also had an increased pseudo-ductility (see Figure 6). Repairing the damaged CMU building with the glass FRP laminate increased the strength of the system by 67% beyond the capacity of the URM baseline building, and increased the energy dissipation (strain energy) of the system by nearly 550%, based on the compression quadrant of the curve. The repair of the damaged URM building with the GFRP laminate resulted in not only a stronger system, but also a much more ductile one as well. The performance of the retrofitted structure (using less composite material with a different layout), although not as spectacular as the repaired structure, did show remarkable increases in terms of both strength and energy dissipation. A 35% increase in strength and a 220% increase in energy dissipation were observed. The maximum tensile strain in the GFRP laminate measured during the test of the repaired structure and had a magnitude of approximately 0.54%. This value was

7 FRPRCS recorded in the flexure-dominated pier at the location of the lintel. The maximum strain measured in the retrofitted structure was approximately 0.8%. This occurred in the small pier at the level of the grouted section at the base of the structure. These strain levels are significantly less than the ultimate tensile strain of 2.1% of the GFRP laminate. Again, this indicates that the failure mode was based on the masonry substrate rather than the capacity of the composite laminate. Brick-Configuration I Similar to the previously discussed buildings, two symmetric two-wythe brick structures were evaluated for seismic performance. Near-surface mounted (NSM) systems were used for the brick buildings, provided by Hughes Brothers, Inc. Aslan 500 #2 carbon FRP bars were used in the repaired structure, while Aslan 100 #3 glass FRP rods was used in the retrofitted structure. The epoxy resin used in both structures was Unitex Pro-Poxy 300, as recommended by the NSM system developer. The installation of the NSM rods involved cutting a vertical groove into the shear walls at the desired locations, placing an epoxy bed into the groove, placing the coated rod/bar into the groove and filling the remaining void with epoxy resin. The grooves were cut such that they passed through head joints, and from a short distance, the composite application resembled expansion joints. The baseline brick building depicted a well-balanced behavior between the push and pull cycles. Also, the linear portion of the curve was seen until a lateral load level of 222 kn (50 Kips). At the peak failure load, the damage to the masonry system was nearly catastrophic (see Figure 7). The large piers exhibited massive diagonal tension cracks as well as bed joint sliding in several locations. The entire front half of the structure moved away from the remaining portions, leaving the structure in two pieces. As a result, the lateral stiffness of the structure was near zero, although the gravity load was maintained at failure. Due to the damage incurred, it was debated whether there is a good reason to spend the effort repairing the structure. In a real repair project these walls would have been demolished, and rebuilt. However, for research purposes, it was decided to repair the building and retest it. Due to the extent of the movement, the mortar joints were repointed before the CFRP composite NSM bars were installed. A total of sixteen bars were placed vertically in the shear walls, with 5 rods installed in each of the large piers, and the remainder divided between the small piers. The response of the repaired structure to the laterally applied load was similar to the unreinforced test (see Figure 8). The stiffness of the structure began to diminish at the load level of 222 kn (50 kips). At the load level of 400 kn (90 kips), the original failure surface of the unreinforced building had reappeared and the CFRP NSM bars then carried the lateral load, mostly through tension and dowel action. Failure occurred at a load level of 490 kn (110 kips) with an associated lateral displacement of mm (0.65 ). The peak load level was nearly identical to the URM brick results, and the energy dissipation for the repaired building was significantly improved. This was a remarkable result, considering the fact that the URM building was catastrophically damaged and only minimal NSM reinforcement was used.

8 296 Foster et al. The retrofitted clay masonry structure received GFRP NSM rods, as compared to the CFRP bars used for the repaired building. Based on the results of small component tests performed, it was decided to use only fourteen rods in the retrofitted configuration, with four rods in each of the large piers and three in each of the small piers. Fewer rods were used to promote cracking in the shear walls and thereby increase ductility. The lateral load level achieved was 534 kn (120 kips), which represents an increase of approximately 10% over the unreinforced structure. The associated lateral displacement was 5.11 mm (0.201 ), which represented only a nominal increase as compared to the URM building results. There was a notable increase in the energy dissipation of the repaired system as compared to the unreinforced test, especially in the pull cycle. The added CFRP composite bars embedded within the shear walls not only fully returned the capacity of the shear walls, but the energy dissipation of the repaired structure were far superior to the unreinforced structure. The amount of energy that could be dissipated was increased by a factor of nearly 3, as compared to the baseline structure which had a calculated strain energy of 1652 Nm (14.62 kip-in) based on the tension quadrant of the backbone curve. The presence of the CFRP bars provided an increase in the ductility and also greatly enhanced the performance of the structure. The retrofitted structure showed increases in terms of ductility and energy dissipation. As previously mentioned, the GFRP composite system used was based on small component testing as was anticipated to provide nominal gains. Despite this, a 70% increase in ductility and 100% increase in strain energy, based on the tension quadrant of the backbone curve. The strain measured during the tests of both the repaired and retrofitted structures were such that the ultimate tensile strain of the GFRP rods and CFRP bars was reached at failure. Prior to failure, the strain measurements were approximately 0.5% and 0.3% in the CFRP bars and GFRP rods, respectively. The strain levels are below the ultimate capacities of 1.5% and 1.9% for the CFRP bars and GFRP rods, respectively. In the case of the repaired structure, the strain level of 0.5% was maintained, while the structure was degrading and a clear slip plane had developed. Significant dowel action was observed in the CFRP bars. The mode of failure for the retrofitted structure was shearing of the GFRP rods (see Figure 9). CMU-Configuration II-Phase I The asymmetric CMU structure was repaired with a GFRP grid system. One layer of TechFab MeC-Grid G15000-BX1 glass grid, with an opening size of roughly 12.7 mm x 6.35 mm (0.5 x 0.25 ), was placed in a polyurea matrix provided by Bondo Corporation on each shear wall. The layout of the GFRP grid system was of a strut-andtie configuration. The undamaged, unreinforced structure failed under an applied lateral load of 445 kn (100 kips). The associated lateral displacement was 6.35 mm (0.25 ). Due to the asymmetry of the structure, torsion was induced. The torsional displacement was 3.81

9 FRPRCS mm (0.15 ) with a of 2.5 mm (0.1 ) displacement variant between the shear walls. The failure mechanism for the structure was diagonal tension cracking that occurred in all piers starting at an applied lateral load of 89 kn (20 kips). The tension failure was primarily localized in the mortar joints. The GFRP grid system drastically enhanced the performance of the damaged structure. At the point of failure, the lateral displacement was three times higher and the lateral load had increased by 25%. The flexible nature of the polyurea resin allowed the structure to achieve even more rotation under the applied lateral load. At failure, extensive diagonal tension cracking occurred in a push cycle (see Figure 10). Composite failure was observed in one of the diagonal elements, where the diagonal tension force clearly exceeded the capacity of the glass FRP grid system. A comparison of the backbone curves, for both the unreinforced and the repaired structures (see Figure 11) reveals that the repaired structure significantly outperformed the unreinforced structure with respect to both strength and deformation. The energy associated with the cyclic lateral force was drastically increased with only one layer of the GFRP composite grid system. The associated strain energies are quite impressive, with an increase of approximately 425%, based on the compression quadrant of the hysteretic curve. SUMMARY OF EXPERIMENTAL RESULTS Several masonry structures were load tested under a constant gravity load and increasing cyclic lateral load. It has been shown that a minimal amount of FRP composite can drastically improve the performance of unreinforced masonry systems in both repair and retrofit applications. GFRP wet lay-up, GFRP and CFRP near surface mounted rods and bars, and GFRP grid systems were tested. An increase in strength, pseudo-ductility and energy dissipation were observed in all cases. Due to the predamaged (and significantly cracked) nature of the repaired buildings, these structures outperformed the retrofitted ones in terms of energy dissipation. It is important to note that, although substantial damage was produced in all building specimens, the gravity load was not lost during any testing. Since the applied gravity load modeled two additional floors, it was imperative that it be maintained, even at failure. The externally applied GFRP wet lay-up composite applied to the symmetric CMU structures resulted in a more ductile and stronger system, as compared to the unreinforced configuration. The addition of the GFRP laminate resulted in a 67% increase and a 541% increase in strength and energy dissipation calculated by integration of the backbone curves, respectively (see Table 1). Failure modes in all cases were diagonal tension cracking in all piers. Since masonry substrate failure governed in all cases, the level of strain measured was much lower than the ultimate tensile of the GFRP laminate, ranging from 0.5% to 0.8% and resulting in a safety factor of 3-4 against composite rupture. The catastrophically damaged symmetric brick structure was repaired using

10 298 Foster et al. CFRP NSM bars and regained 100% of the strength of the system. The addition of the composite bars increased the lateral displacement of the system by a factor of nearly 3.5 (see Table 2), resulting in a 300% increase in strain energy dissipation. The retrofitted structure received GFRP NSM rods, which also increased the performance of the building specimen, although not to the same degree. As with the previous structure, the method of failure was diagonal tension cracking, present in all piers of the structure. The measured strain values in both the CFRP bars and GFRP NSM rods ranged from 0.3% for retrofitted system to 0.5% for the repaired system prior to masonry failure. Similar results were observed for the asymmetric CMU structure as compared with symmetric CMU structure. Increases of 420% in energy dissipation and 270% were measured during the test of the repaired structure. The degree of rotation of the structure was increased due to the application of the polyurea-gfrp grid composite system. Similar to the other structures, diagonal tension was the observed failure mode. At failure, composite rupture was observed at one location where the tension force exceeded the capacity of the GFRP grid. Future research may include optimization of the FRP systems used and exploration of new systems. Since only two building configurations were examined, the possibility for a broader investigation exists as well as development of an anchoring methodology, if a positive foundation connection does not exist. CONCLUSIONS The experimental program has shown that FRP composite laminates can restore and significantly enhance the seismic performance of unreinforced masonry structures, in a damaged and undamaged configuration. Multiple FRP systems were utilized and all were well below ultimate strain values for each respective laminate at failure of the masonry building specimens. ACKNOWLEDGEMENTS The authors would like to thank the National Science Foundation (Award Number CMS ) for funding this project. Also, the authors would like to thank their composite and masonry industry partners, who have made significant material and labor contributions to the project. These included the Carolina Concrete Masonry Association (CCMA), the Brick Industry Association (BIA), the North Carolina Masonry Contractors Association (NCMCA), Sika and Unitex Chemicals. REFERENCES Albert, M., Elwi, A. and Cheng, J.J., 2001, Strengthening of Unreinforced Masonry Walls Using FRPs, Journal of Composites for Construction, May, V. 5, No. 2, pp Al-Chaar, G.K. and Hassan, H.A., 1999, May 10-12, Seismic Testing and Dynamic

11 FRPRCS Analysis of Masonry Bearing and Shear Walls Retrofitted with Overlay Composite, Proceeding of ICE 99, Cincinnati, OH, 1999 (Session 4-B), pp Ehsani, M.R. and Saadatmanesh, H., 1996, Seismic Retrofit of URM Walls with Fiber Composites, The Masonry Society, December, V. 14, No. 2, pp Federal Emergency Management Agency, November 2000, Prestandard and Commentary for the Seismic Rehabilitation of Buildings, FEMA 356, Section pg 2-28, Washington, D.C. Gergely, J., and Young, D.T., October 2001, Masonry Wall Retrofitted with CFRP Materials, Proceedings of the 1 st International Conference on Composites in Construction, Porto, Portugal, 2001, Figueiras et al (eds), Swets and Zeitlinger, pp Hamid, A.A., El-Dakhakni, W.W., Hakam, Z.H. and Elgaaly, M., 2005, Behavior of Composite Unreinforced Masonry Fiber-Reinforced Polymer Wall Assemblages Under In-Plane Loading, Journal of Composite for Construction, V. 5, No. 1, pp Hamilton III, H.R. and Dolan, C.W., 2001, Flexural Capacities of Glass FRP Strengthened Concrete Masonry Walls, Journal of Composites for Construction, V. 5, No. 3, pp Hamoush, S., McGinley, M., Mlakar, P., Scott, D. and Murray, K., 2001, Out-of-plane Strengthening of Masonry Walls with Reinforced Composites, Journal of Composites for Construction, August, V. 5, No. 2, pp Marshall, O.S, Sweeney, S.C. and Trovillion, J.C., 1999, Seismic Rehabilitation of Unreinforced Masonry Walls, Proceedings of the Fourth International Symposium on Fiber Reinforcement for Reinforced Concrete Structures, Batlimore, MD, 1999 (SP188-26), American Concrete Institute, pp Moon, F.L., Yi, T., Leon, R.T. and Kahn, L.F., 2002, September 9-13, Seismic Strengthening of Unreinforced Masonry Structures with FRP Overlays and Posttensioning, Proceeding of the 12 th European Conference on Earthquake Engineering, London, England, 2002 (Paper Reference 123), pp. 10. Silva, P., Myers, J., Belarbi, A., Tumialan, G., El-Domiaty, K., and Nanni, A., 2001, July 4-6, Performance of Infill URM Wall Systems Retrofitted with FRP Rods and Laminates to Resist In-Plane and Out-of-Plane Loads, Proceeding of Structural Faults and Repairs, London, UK, 2001, pp

12 300 Foster et al. Figure 1 Plan view of the symmetric configuration (asymmetric not shown).

13 FRPRCS Figure 2 Hysteretic curve for the unreinforced, symmetric CMU structure. Figure 3 Free body diagram from determination of composite layout using a strut and tie configuration.

14 302 Foster et al. Figure 4 GFRP composite layout for the repaired symmetric CMU structure. Figure 5 Damage sustained during experimental load testing of the symmetric retrofitted CMU structure.

15 FRPRCS Figure 6 Idealized backbone curve for the unreinforced, repaired and retrofitted symmetric CMU structures. Figure 7 Damaged incurred during experimental testing of the symmetric unreinforced brick structure.

16 304 Foster et al. Figure 8 Backbone curves for unreinforced, repaired and retrofitted symmetric brick structures. Figure 9 Diagonal tension failure and GFRP NSM rod rupture of the symmetric retrofitted brick structure.

17 FRPRCS Figure 10 Damaged induced by an applied 556 kn (125 kips) lateral force to a repaired asymmetric CMU structure. Figure 11 Backbone curve comparison for asymmetric CMU structure in unreinforced and repaired condition.

18 306 Foster et al.

Rehabilitation of Unreinforced Brick Masonry Walls Using Composites

Rehabilitation of Unreinforced Brick Masonry Walls Using Composites Rehabilitation of Unreinforced Brick Masonry Walls Using Composites Mohamed AbdelMonem ElGawady, Pierino Lestuzzi, Marc Badoux Swiss Federal Institute of Technology at Lausanne EPFL, Switzerland Introduction

More information

Technical Notes 3B - Brick Masonry Section Properties May 1993

Technical Notes 3B - Brick Masonry Section Properties May 1993 Technical Notes 3B - Brick Masonry Section Properties May 1993 Abstract: This Technical Notes is a design aid for the Building Code Requirements for Masonry Structures (ACI 530/ASCE 5/TMS 402-92) and Specifications

More information

APE T CFRP Aslan 500

APE T CFRP Aslan 500 Carbon Fiber Reinforced Polymer (CFRP) Tape is used for structural strengthening of concrete, masonry or timber elements using the technique known as Near Surface Mount or NSM strengthening. Use of CFRP

More information

bi directional loading). Prototype ten story

bi directional loading). Prototype ten story NEESR SG: Behavior, Analysis and Design of Complex Wall Systems The laboratory testing presented here was conducted as part of a larger effort that employed laboratory testing and numerical simulation

More information

The Original Carbon Fiber Reinforced Polymer System

The Original Carbon Fiber Reinforced Polymer System Infrastructure The Original Carbon Fiber Reinforced Polymer System Phone: 52.292.39 Toll Free: 866.38.269 Fax: 52.48.5274 282 E. Fort Lowell Rd. Tucson, AZ 8576 www.dowaksausa.com Test results are supported

More information

In-situ Load Testing to Evaluate New Repair Techniques

In-situ Load Testing to Evaluate New Repair Techniques In-situ Load Testing to Evaluate New Repair Techniques W.J. Gold 1 and A. Nanni 2 1 Assistant Research Engineer, Univ. of Missouri Rolla, Dept. of Civil Engineering 2 V&M Jones Professor, Univ. of Missouri

More information

Aseismic retrofitting of unreinforced masonry walls using FRP

Aseismic retrofitting of unreinforced masonry walls using FRP Composites: Part B 37 (26) 148 162 www.elsevier.com/locate/compositesb Aseismic retrofitting of unreinforced masonry walls using FRP Mohamed A. ElGawady*, Pierino Lestuzzi, Marc Badoux Swiss Federal Institute

More information

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS 1 th Canadian Masonry Symposium Vancouver, British Columbia, June -5, 013 DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS Vladimir G. Haach 1, Graça Vasconcelos and Paulo

More information

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS Fracture Mechanics of Concrete Structures Proceedings FRAMCOS-3 AEDIFICA TIO Publishers, D-79104 Freiburg, Germany SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS H.

More information

ASSESSMENT AND PROPOSED STRUCTURAL REPAIR STRATEGIES FOR BRIDGE PIERS IN TAIWAN DAMAGED BY THE JI-JI EARTHQUAKE ABSTRACT

ASSESSMENT AND PROPOSED STRUCTURAL REPAIR STRATEGIES FOR BRIDGE PIERS IN TAIWAN DAMAGED BY THE JI-JI EARTHQUAKE ABSTRACT ASSESSMENT AND PROPOSED STRUCTURAL REPAIR STRATEGIES FOR BRIDGE PIERS IN TAIWAN DAMAGED BY THE JI-JI EARTHQUAKE Pei-Chang Huang 1, Graduate Research Assistant / MS Candidate Yao T. Hsu 2, Ph.D., PE, Associate

More information

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California 94103. Prepared By

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California 94103. Prepared By Project Structural Conditions Survey and Seismic Vulnerability Assessment For SFCC Civic Center Campus 750 Eddy Street San Francisco, California 94109 Prepared For San Francisco Community College District

More information

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1 Chapter 5 Bridge Deck Slabs Bridge Engineering 1 Basic types of bridge decks In-situ reinforced concrete deck- (most common type) Pre-cast concrete deck (minimize the use of local labor) Open steel grid

More information

What is Seismic Retrofitting?

What is Seismic Retrofitting? What is Seismic Retrofitting? SEISMIC RETROFITTING A Seismic Retrofit provides existing structures with more resistance to seismic activity due to earthquakes. In buildings, this process typically includes

More information

Seismic Retrofit of Reinforced Concrete Beam- Column T-Joints in Bridge Piers with FRP Composite Jackets

Seismic Retrofit of Reinforced Concrete Beam- Column T-Joints in Bridge Piers with FRP Composite Jackets SP-258 1 Seismic Retrofit of Reinforced Concrete Beam- Column T-Joints in Bridge Piers with FRP Composite Jackets by C.P. Pantelides and J. Gergely Synopsis: The research described encompasses laboratory

More information

beams columns blast walls slabs pipes protective coatings polymer concrete Solutions Looking for Problems...

beams columns blast walls slabs pipes protective coatings polymer concrete Solutions Looking for Problems... beams columns blast walls slabs pipes protective coatings polymer concrete Solutions Looking for Problems... CarbonWrap Solutions Services Turnkey Innovative Solutions and Products CarbonWrap Solutions,

More information

SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP

SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 3279 SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP Yuming DING 1, Bruce HAMERSLEY 2 SUMMARY Vancouver

More information

Retrofitting By Means Of Post Tensioning. Khaled Nahlawi 1

Retrofitting By Means Of Post Tensioning. Khaled Nahlawi 1 Retrofitting By Means Of Post Tensioning Khaled Nahlawi 1 Abstract An analytical program was prepared to retrofit the Holy Cross Church in Santa Cruz, California. An inelastic analysis was perfonned on

More information

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety

More information

SEISMIC RETROFITTING OF STRUCTURES

SEISMIC RETROFITTING OF STRUCTURES SEISMIC RETROFITTING OF STRUCTURES RANJITH DISSANAYAKE DEPT. OF CIVIL ENGINEERING, FACULTY OF ENGINEERING, UNIVERSITY OF PERADENIYA, SRI LANKA ABSTRACT Many existing reinforced concrete structures in present

More information

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training Foundations 65 5 FOUNDATIONS by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. 66 Foundations Foundations 67 FOUNDATIONS Let's assume that the retrofit has been done correctly from the roofline

More information

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION TECHNICAL NOTE On Cold-Formed Steel Construction 1201 15th Street, NW, Suite 320 W ashington, DC 20005 (202) 785-2022 $5.00 Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006

More information

4B-2. 2. The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

4B-2. 2. The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections. Shear Walls Buildings that use shear walls as the lateral force-resisting system can be designed to provide a safe, serviceable, and economical solution for wind and earthquake resistance. Shear walls

More information

METHOD OF STATEMENT FOR STATIC LOADING TEST

METHOD OF STATEMENT FOR STATIC LOADING TEST Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents

More information

Methods for Seismic Retrofitting of Structures

Methods for Seismic Retrofitting of Structures Methods for Seismic Retrofitting of Structures Retrofitting of existing structures with insufficient seismic resistance accounts for a major portion of the total cost of hazard mitigation. Thus, it is

More information

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading: SEISMIC DESIGN Various building codes consider the following categories for the analysis and design for earthquake loading: 1. Seismic Performance Category (SPC), varies from A to E, depending on how the

More information

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE A.Rito Proponte, Lda, Lisbon, Portugal J. Appleton A2P Consult, Lda, Lisbon, Portugal ABSTRACT: The Figueira da Foz Bridge includes a 405 m long cable stayed

More information

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile J. Sherstobitoff Ausenco Sandwell, Vancouver, Canada P. Cajiao AMEC, Vancouver, Canada P. Adebar University of British

More information

Performance of Existing Reinforced Concrete Columns under Bidirectional Shear & Axial Loading

Performance of Existing Reinforced Concrete Columns under Bidirectional Shear & Axial Loading Performance of Existing Reinforced Concrete Columns under Bidirectional Shear & Axial Loading Laura M. Flores University of California, San Diego REU Institution: University of California, Berkeley REU

More information

BEHAVIOR OF WELDED T-STUBS SUBJECTED TO TENSILE LOADS

BEHAVIOR OF WELDED T-STUBS SUBJECTED TO TENSILE LOADS BEHAVIOR OF WELDED T-STUBS SUBJECTED TO TENSILE LOADS R.A. Herrera 1, G. Desjouis 2, G. Gomez 2, M. Sarrazin 3 1 Assistant Professor, Dept. of Civil Engineering, University of Chile, Santiago, Chile 2

More information

Validation of Cable Bolt Support Design in Weak Rock Using SMART Instruments and Phase 2

Validation of Cable Bolt Support Design in Weak Rock Using SMART Instruments and Phase 2 Validation of Cable Bolt Support Design in Weak Rock Using SMART Instruments and Phase 2 W.F. Bawden, Chair Lassonde Mineral Engineering Program, U. of Toronto, Canada J.D. Tod, Senior Engineer, Mine Design

More information

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination Structural Effective Beginning with the April 2011 The structural engineering exam is a breadth and exam examination offered in two components on successive days. The 8-hour Vertical Forces (Gravity/Other)

More information

Experimental assessment of concrete damage due to exposure to high temperature and efficacy of the repair system

Experimental assessment of concrete damage due to exposure to high temperature and efficacy of the repair system MATEC Web of Conferences 6, 06002 (2013) DOI: 10.1051/matecconf/20130606002 C Owned by the authors, published by EDP Sciences, 2013 Experimental assessment of concrete damage due to exposure to high temperature

More information

Strengthening of a Bridge Using Two FRP Technologies. Paolo Casadei, Nestore Galati, Renato Parretti and Antonio Nanni

Strengthening of a Bridge Using Two FRP Technologies. Paolo Casadei, Nestore Galati, Renato Parretti and Antonio Nanni Strengthening of a Bridge Using Two FRP Technologies Paolo Casadei, Nestore Galati, Renato Parretti and Antonio Nanni Synopsis This paper reports on the use of externally bonded fiber reinforced polymers

More information

STRENGTHENING AND LOAD TESTING OF THREE BRIDGES IN BOONE COUNTY, MO

STRENGTHENING AND LOAD TESTING OF THREE BRIDGES IN BOONE COUNTY, MO STRENGTHENING AND LOAD TESTING OF THREE BRIDGES IN BOONE COUNTY, MO S. Schiebel 1, R. Parretti 1, A. Nanni 2, and M. Huck 3 ABSTRACT Three bridges in Boone County, Missouri (Brown School Road Bridge, Coats

More information

Detailing of Reinforcment in Concrete Structures

Detailing of Reinforcment in Concrete Structures Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For

More information

SECTION 7 Engineered Buildings Field Investigation

SECTION 7 Engineered Buildings Field Investigation SECTION 7 Engineered Buildings Field Investigation Types of Data to Be Collected and Recorded A field investigator looking at engineered buildings is expected to assess the type of damage to buildings.

More information

Numerical modelling of shear connection between concrete slab and sheeting deck

Numerical modelling of shear connection between concrete slab and sheeting deck 7th fib International PhD Symposium in Civil Engineering 2008 September 10-13, Universität Stuttgart, Germany Numerical modelling of shear connection between concrete slab and sheeting deck Noémi Seres

More information

REPAIR AND STRENGTHENING OF HISTORICAL CONCRETE BRIDGE OVER VENTA RIVER IN LATVIA

REPAIR AND STRENGTHENING OF HISTORICAL CONCRETE BRIDGE OVER VENTA RIVER IN LATVIA 1 REPAIR AND STRENGTHENING OF HISTORICAL CONCRETE BRIDGE OVER VENTA RIVER IN LATVIA Verners Straupe, M.sc.eng., Rudolfs Gruberts, dipl. eng. JS Celuprojekts, Murjanu St. 7a, Riga, LV 1024, Latvia e-mail:

More information

6 RETROFITTING POST & PIER HOUSES

6 RETROFITTING POST & PIER HOUSES Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This

More information

SEISMIC RETROFITTING OF EARTHQUAKE-DAMAGED CONCRETE COLUMNS BY LATERAL PRE-TENSIONING OF FRP BELTS. K. Nasrollahzadeh Nesheli 1 and K.

SEISMIC RETROFITTING OF EARTHQUAKE-DAMAGED CONCRETE COLUMNS BY LATERAL PRE-TENSIONING OF FRP BELTS. K. Nasrollahzadeh Nesheli 1 and K. Proceedings of the 8 th U.S. National Conference on Earthquake Engineering April 18-22, 26, San Francisco, California, USA Paper No. 841 SEISMIC RETROFITTING OF EARTHQUAKE-DAMAGED CONCRETE COLUMNS BY LATERAL

More information

Section 5A: Guide to Designing with AAC

Section 5A: Guide to Designing with AAC Section 5A: Guide to Designing with AAC 5A.1 Introduction... 3 5A.3 Hebel Reinforced AAC Panels... 4 5A.4 Hebel AAC Panel Design Properties... 6 5A.5 Hebel AAC Floor and Roof Panel Spans... 6 5A.6 Deflection...

More information

Seismic Risk Prioritization of RC Public Buildings

Seismic Risk Prioritization of RC Public Buildings Seismic Risk Prioritization of RC Public Buildings In Turkey H. Sucuoğlu & A. Yakut Middle East Technical University, Ankara, Turkey J. Kubin & A. Özmen Prota Inc, Ankara, Turkey SUMMARY Over the past

More information

Use of Strain Gauge Rosette to Investigate Stress concentration in Isotropic and Orthotropic Plate with Circular Hole

Use of Strain Gauge Rosette to Investigate Stress concentration in Isotropic and Orthotropic Plate with Circular Hole Use of Strain Gauge Rosette to Investigate Stress concentration in Isotropic and Orthotropic Plate with Circular Hole Mr.V.G.Aradhye 1, Prof.S.S.Kulkarni 2 1 PG Scholar, Mechanical department, SKN Sinhgad

More information

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14 Draft Table of Contents Building Code Requirements for Structural Concrete and Commentary ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318 14) Chapter 1 General 1.1 Scope of ACI 318

More information

Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE

Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE To satisfy the performance goals of the NEHRP Recommended Seismic Provisions, a number of characteristics are important to the

More information

PERFORMANCE BASED SEISMIC EVALUATION AND RETROFITTING OF UNSYMMETRICAL MEDIUM RISE BUILDINGS- A CASE STUDY

PERFORMANCE BASED SEISMIC EVALUATION AND RETROFITTING OF UNSYMMETRICAL MEDIUM RISE BUILDINGS- A CASE STUDY Paper No. 682 PERFORMANCE BASED SEISMIC EVALUATION AND RETROFITTING OF UNSYMMETRICAL MEDIUM RISE BUILDINGS- A CASE STUDY Jimmy Chandra, Pennung Warnitchai, Deepak Rayamajhi, Naveed Anwar and Shuaib Ahmad

More information

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS 1.0 DESIGN 1.1 Scope of Work 1.1.1 This work shall consist of furnishing Isolation Bearings and installing Isolation Bearing Assemblies at the locations

More information

PRESTRESSED CONCRETE. Introduction REINFORCED CONCRETE CHAPTER SPRING 2004. Reinforced Concrete Design. Fifth Edition. By Dr. Ibrahim.

PRESTRESSED CONCRETE. Introduction REINFORCED CONCRETE CHAPTER SPRING 2004. Reinforced Concrete Design. Fifth Edition. By Dr. Ibrahim. CHAPTER REINFORCED CONCRETE Reinforced Concrete Design A Fundamental Approach - Fifth Edition Fifth Edition PRESTRESSED CONCRETE A. J. Clark School of Engineering Department of Civil and Environmental

More information

Expected Performance Rating System

Expected Performance Rating System Expected Performance Rating System In researching seismic rating systems to determine how to best classify the facilities within the Portland Public School system, we searched out what was used by other

More information

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete Ming-Gin Lee 1,a, Yi-Shuo Huang 1,b 1 Department of Construction Engineering, Chaoyang University of Technology,Taichung

More information

A Decade of Performance of FRP-Repaired Concrete Structures

A Decade of Performance of FRP-Repaired Concrete Structures A Decade of Performance of FRP-Repaired Concrete Structures Shamim A. Sheikh and S. Mukhtar Homam Department of Civil Engineering University of Toronto Toronto, Canada ABSTRACT During the last ten years,

More information

Prestressed Concrete Pipe Fitness for Service and Repair

Prestressed Concrete Pipe Fitness for Service and Repair Prestressed Concrete Pipe Fitness for Service and Repair Rasko Ojdrovic [email protected] 781-907-9231 IAEA - EPRI 15 October 2014 www.sgh.com SGH Pipeline Experience More than 25 years of research, analysis,

More information

Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied

Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied Stress and strain fracture or engineering point of view: allows to predict the

More information

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars Report on Wind Resistance of Signs supported by Glass Fiber Reinforced Concrete (GFRC) Pillars Prepared for US Sign and Fabrication Corporation January, 2006 SUMMARY This study found the attachment of

More information

STRENGTHENING OF RC BRIDGE WITH MECHANICALLY FASTENED-FRP FRP STRIPS

STRENGTHENING OF RC BRIDGE WITH MECHANICALLY FASTENED-FRP FRP STRIPS May 5 th 4 STRENGTHENING OF RC BRIDGE WITH MECHANICALLY FASTENED-FRP FRP STRIPS Andrea Rizzo (Graduate Research Assistants) Dr. Nestore Galati (Research Engineer) Dr. A. Nanni (Faculty Advisors) Meramec

More information

Seismic Retrofit of Existing Buildings: Innovative Alternatives

Seismic Retrofit of Existing Buildings: Innovative Alternatives Seismic Retrofit of Existing Buildings: Innovative Alternatives Moe Cheung and Simon Foo Public Works & Government Services Canada Hull, Quebec, Canada Jacques Granadino Public Works & Government Services

More information

Reinforced Concrete Design

Reinforced Concrete Design FALL 2013 C C Reinforced Concrete Design CIVL 4135 ii 1 Chapter 1. Introduction 1.1. Reading Assignment Chapter 1 Sections 1.1 through 1.8 of text. 1.2. Introduction In the design and analysis of reinforced

More information

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following.

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following. MECHANICS OF SOLIDS - BEAMS TUTOIAL 1 STESSES IN BEAMS DUE TO BENDING This is the first tutorial on bending of beams designed for anyone wishing to study it at a fairly advanced level. You should judge

More information

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing 1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize

More information

Shear Strengthening. Sika CarboDur Composite Systems

Shear Strengthening. Sika CarboDur Composite Systems Solutions with Sika Systems Shear Strengthening Sika CarboDur Composite Systems Long term tested and approved systems High strength composite systems Corrosion resistant Easy application No maintenance

More information

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning May 7th 2013: Dominique Deschamps Scope of the paper Presentation of the project Cause of cracks

More information

Stress Strain Relationships

Stress Strain Relationships Stress Strain Relationships Tensile Testing One basic ingredient in the study of the mechanics of deformable bodies is the resistive properties of materials. These properties relate the stresses to the

More information

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar, Volume, Special Issue, ICSTSD Behaviour of Steel Bracing as a Global Retrofitting Technique Miss S. S. Nibhorkar M. E (Structure) Scholar, Civil Engineering Department, G. H. Raisoni College of Engineering

More information

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials. Lab 3 Tension Test Objectives Concepts Background Experimental Procedure Report Requirements Discussion Objectives Experimentally determine the yield strength, tensile strength, and modules of elasticity

More information

Type of Force 1 Axial (tension / compression) Shear. 3 Bending 4 Torsion 5 Images 6 Symbol (+ -)

Type of Force 1 Axial (tension / compression) Shear. 3 Bending 4 Torsion 5 Images 6 Symbol (+ -) Cause: external force P Force vs. Stress Effect: internal stress f 05 Force vs. Stress Copyright G G Schierle, 2001-05 press Esc to end, for next, for previous slide 1 Type of Force 1 Axial (tension /

More information

EAST LYME HIGH SCHOOL

EAST LYME HIGH SCHOOL Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed

More information

Rehabilitation of Existing Foundation Building to Resist Lateral and Vertical Loads

Rehabilitation of Existing Foundation Building to Resist Lateral and Vertical Loads International Journal of Current Microbiology and Applied Sciences ISSN: 2319-7706 Volume 3 Number 12 (2014) pp. 950-961 http://www.ijcmas.com Original Research Article Rehabilitation of Existing Foundation

More information

Seismic performance evaluation of an existing school building in Turkey

Seismic performance evaluation of an existing school building in Turkey CHALLENGE JOURNAL OF STRUCTURAL MECHANICS 1 (4) (2015) 161 167 Seismic performance evaluation of an existing school building in Turkey Hüseyin Bilgin * Department of Civil Engineering, Epoka University,

More information

Design and Construction of Cantilevered Reinforced Concrete Structures

Design and Construction of Cantilevered Reinforced Concrete Structures Buildings Department Practice Note for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers APP-68 Design and Construction of Cantilevered Reinforced Concrete Structures

More information

REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:

REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for: HANDOUT REINFORCED CONCRETE Reinforced Concrete Design A Fundamental Approach - Fifth Edition RETAINING WALLS Fifth Edition A. J. Clark School of Engineering Department of Civil and Environmental Engineering

More information

ICC-ES Evaluation Report

ICC-ES Evaluation Report ICC-ES Evaluation Report ESR-2369 Reissued May 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

Using StrongPIPE Hybrid FRP for PCCP Rehab in Miami-Dade System

Using StrongPIPE Hybrid FRP for PCCP Rehab in Miami-Dade System Using StrongPIPE Hybrid FRP for PCCP Rehab in Miami-Dade System Luis Aguiar Miami-Dade Water & Sewer Department Anna Pridmore, PhD Structural Technologies PROJECT BACKGROUND Miami-Dade Water & Sewer Department

More information

Advanced Retrofitting Methods and Techniques for RC Building: State of an Art

Advanced Retrofitting Methods and Techniques for RC Building: State of an Art Advanced Retrofitting Methods and Techniques for RC Building: State of an Art Miss. Swati Sanjay Nibhorkar * M. E (Structure) Scholar, Civil Engineering Department, G. H. Raisoni College of Engg and Management,

More information

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER

More information

THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS

THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS Technical Innovation Consultancy Emeritus Professor of Civil Engineering Kingston University, London.

More information

Strengthening and Repair of Reinforced Concrete Structures. Ian Wienholt Business Development Manager

Strengthening and Repair of Reinforced Concrete Structures. Ian Wienholt Business Development Manager Strengthening and Repair of Reinforced Concrete Structures Ian Wienholt Business Development Manager 34 years of Concrete Repair and Strengthening Experience Over 12,000 Repair Project Over 25,000 PT Projects

More information

Seismic Assessment and Retrofitting of Structures: Eurocode8 Part3 and the Greek Code on Seismic Structural Interventions

Seismic Assessment and Retrofitting of Structures: Eurocode8 Part3 and the Greek Code on Seismic Structural Interventions Working Group 7: Earthquake Resistant Structures Geneva, 25 September 2015 Seismic Assessment and Retrofitting of Structures: Eurocode8 Part3 and the Greek Code on Seismic Structural Interventions Prof.

More information

SEISMIC REHABILITATION OF COLUMN TO PIER CAP ACCELERATED BRIDGE CONSTRUCTION CONNECTIONS AND ACOUSTIC EMISSION MONITORING ASSESSM ENT

SEISMIC REHABILITATION OF COLUMN TO PIER CAP ACCELERATED BRIDGE CONSTRUCTION CONNECTIONS AND ACOUSTIC EMISSION MONITORING ASSESSM ENT SEISMIC REHABILITATION OF COLUMN TO PIER CAP ACCELERATED BRIDGE CONSTRUCTION CONNECTIONS AND ACOUSTIC EMISSION MONITORING ASSESSM ENT by Joel Edgar Parks A thesis submitted to the faculty of The University

More information

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major

More information

Lessons 6 and 7 Foam Bridge Experiment- Forces and Stresses Lab

Lessons 6 and 7 Foam Bridge Experiment- Forces and Stresses Lab Lessons 6 and 7 Foam Bridge Experiment- Forces and Stresses Lab 1. Background All industrial and building materials undergo forces that they must withstand to function as designed. Concrete is strong under

More information

Hardened Concrete. Lecture No. 14

Hardened Concrete. Lecture No. 14 Hardened Concrete Lecture No. 14 Strength of Concrete Strength of concrete is commonly considered its most valuable property, although in many practical cases, other characteristics, such as durability

More information

The International Journal Of Science & Technoledge (ISSN 2321 919X) www.theijst.com

The International Journal Of Science & Technoledge (ISSN 2321 919X) www.theijst.com THE INTERNATIONAL JOURNAL OF SCIENCE & TECHNOLEDGE Retrofitting of Fire Affected Structural Member in Multistorey Buildings Chandrakant PG Scholar, Department of Civil Engineering S.D.M. College of Engineering

More information

BRIDGE REHABILITATION TECHNIQUES

BRIDGE REHABILITATION TECHNIQUES BRIDGE REHABILITATION TECHNIQUES Yogesh Chhabra, General Manager, The D S Brown Company, 57 Pioneer Road, Singapore 628508 Web www.dsbrown.com E-Mail [email protected] Ph. +6598444104, +6565588111

More information

Chapter. Earthquake Damage: Types, Process, Categories

Chapter. Earthquake Damage: Types, Process, Categories 3 Chapter Earthquake Damage: Types, Process, Categories Earthquakes leave behind a trail of damage and destruction. People s lives are affected by the loss of loved ones, destruction of property, economic

More information

NUMERICAL ANALYSIS OF GLULAM BEAMS WITHOUT AND WITH GFRP REINFORCEMENT

NUMERICAL ANALYSIS OF GLULAM BEAMS WITHOUT AND WITH GFRP REINFORCEMENT 10th International Conference on Composite Science and Technology ICCST/10 A.L. Araújo, J.R. Correia, C.M. Mota Soares, et al. (Editors) IDMEC 2015 NUMERICAL ANALYSIS OF GLULAM BEAMS WITHOUT AND WITH GFRP

More information

Construction. Structural Strengthening with SikaWrap Fabric Systems

Construction. Structural Strengthening with SikaWrap Fabric Systems Construction Structural Strengthening with SikaWrap Fabric Systems Strengthening Fibers, SikaWrap Fabrics and Sikadur Resins Strengthening Fiber Types Three different main types of fibers are suitable

More information

2009-12-23 ICS: 93.160. Strengthening retrofitting of reinforced concrete structures by gluing of fibre reinforced polymeric fabrics (FRP fabrics)

2009-12-23 ICS: 93.160. Strengthening retrofitting of reinforced concrete structures by gluing of fibre reinforced polymeric fabrics (FRP fabrics) 36888 ежглеяис тгс йубеямгсеыс (теувос еутеяо) 20091223 ICS: 93160 150114010801:2009 H HELLENIC CHNICAL SPECIFICATION (FRP ) Strengthening retrofitting of reinforced concrete structures by gluing of fibre

More information

Optimum proportions for the design of suspension bridge

Optimum proportions for the design of suspension bridge Journal of Civil Engineering (IEB), 34 (1) (26) 1-14 Optimum proportions for the design of suspension bridge Tanvir Manzur and Alamgir Habib Department of Civil Engineering Bangladesh University of Engineering

More information

FLEXURAL BEHAVIOUR OF HYBRID FRP-UHPC GIRDERS UNDER STATIC LOADING

FLEXURAL BEHAVIOUR OF HYBRID FRP-UHPC GIRDERS UNDER STATIC LOADING Proceedings of 8 th International Conference on Short and Medium Span Bridge Niagara Falls, Canada 21 FLEXURAL BEHAVIOUR OF HYBRID FRP-UHPC GIRDERS UNDER STATIC LOADING Donna S. M. Chen Department of Civil

More information

HIGH LEVEL SEISMIC UPGRADE COST ESTIMATE FOR CENTRE BLOCK, PARLIAMENT HILL

HIGH LEVEL SEISMIC UPGRADE COST ESTIMATE FOR CENTRE BLOCK, PARLIAMENT HILL HIGH LEVEL SEISMIC UPGRADE COST ESTIMATE FOR CENTRE BLOCK, PARLIAMENT HILL Prepared for: Public Works and Government Services Canada Parliamentary Precinct Branch Prepared by: Halsall Associates 210 Gladstone

More information

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab, DESIGN OF SLABS Dr. G. P. Chandradhara Professor of Civil Engineering S. J. College of Engineering Mysore 1. GENERAL A slab is a flat two dimensional planar structural element having thickness small compared

More information