City of Margate, Florida Building Department. Minimum Permit Requirements For Roofing

Similar documents
SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

CITY OF FLORIDA CITY Building and Zoning Department 404 West Palm Drive Florida City, FL ROOFING PERMIT APPLICATION

Building Permit Application

RESIDENTIAL ROOF PERMITTING A REFRESHER WORKSHOP September 11, 2014

CODE IN EFFECT: 2010 FLORIDA BUILDING CODE PERMIT APPLICATIONS MUST BE FILLED OUT COMPLETELY

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Wind Mitigation Inspection

Bay County Builders Services Main Office FAX: (850) PHONE: (850)

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

The Florida Building Code

Larry Haight's Residential Roofing Co, Inc NE 95th Street Redmond, Washington Phone: (425) Fax: (425)

Georgia State University. Urban Life Building Roof Replacement

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

The Florida Building Code

ROOF INSPECTION REPORT

Asphalt Shingle Application Requirements

Preventing Ice Dams on Roofs

Dollars & Sense of Compliance!

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

TARRANT COUNTY DETAIL STANDARDS

Residential Roofing Guide

NRCA s steep-slope manual is thoroughly revised for 2013

Mark Cramer Inspection Services, Inc.

CITY OF BELL PROFESSIONAL CONSULTING SERVICES FOR ROOF REPAIRS TO CITY OWNED FACILITIES

Who Can Apply (A or B)

CHAPTER 7: Building Systems ROOFING SYSTEMS

CITIZENS PROPERTY INSURANCE CORPORATION. STREET ADDRESS: Gulf Blvd, Maderia Beach, FL Six story masonry residence

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

Metal Roof Systems in High-Wind Regions

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

PERMIT APPLICATION. PLEASE PRINT LEGIBLY INCLUDE STREET NUMBER/NAME, CITY & STATE 1 Job Name:

Detached accessory structures that contain no conditioned floor area are exempt.

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

Protecting YOUR NEW HOME FROM Wind Damage

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

CITIZENS PROPERTY INSURANCE CORPORATION BUILDING TYPE II AND III MITIGATION VERIFICATION AFFIDAVIT

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Estimated Cost of Repair

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Sample Drawing Package for One and Two Family Dwelling Applications

Materials and Colors

Roof Inspection. Summary Report

C. Remove all existing asphalt shingles, underlayment and any loose debris into contractor provided dumpsters.

Commercial Roof Management

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:

ROOF ASSEMBLIES CHAPTER 9

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

Pre-Drywall Inspection Report

ELIGIBILITY CHECKLIST:

RB271 06/07 R807.1 RB272 06/07 R Public Hearing: Committee: AS AM D Assembly: ASF AMF DF. Proponent: Rick Davidson, City of Hopkins, MN

SOLAR ENERGY PERMIT. 1. Two (2) page Building Permit Application (signed and notarized); 2. Disclosure Affidavit (signed and notarized);

Appendix B Florida Building Code Building Section Public Shelter Design Criteria

Claridge Condominium Association, Inc Pelican Bay Blvd. Naples, FL 34108

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

Florida Building Code Advanced Training: Residential Roofing Shingles

BUILDING PERMIT RESIDENTIAL BASEMENT FINISH

SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE NOTICE TO PROPERTY OWNER

High Wind & Hail Standards

Residential Building Permits Information

Who Can Apply (A or B)

October 5, 2015 Dear Client,

Excerpts from the Canadian National Building Code (NBC)

SUBSTANTIAL IMPROVEMENT/DAMAGE NOTICE TO PROPERTY OWNERS

ROOFING CONTRACTORS QUESTIONNAIRE

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Inspection Item COMMENTS

Shed Application Package

HCD DSA OSHPD 1 2 1/AC AC SS

Sheet A-1 KEY SHEET A-1. Football Roof Plan SHEET A-2 SHEET A-3 SHEET A-4. LaCross Roof Plan. Soccor 2 Roof Plan 88' 45' 87' 46' 45' 45' 10' 3' 25'

Retrofitting an Insulated Cold Roof

REQUIREMENTS FOR OBTAINING A THORNBURY TOWNSHIP, DELAWARE COUNTY PERMIT

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

City of Beacon Building Department

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

ELIGIBLE REPAIR PROJECT PARAMETERS

VENDOR INFORMATION. Company Name: Billing Address: Telephone #: Fax #: Contact Name: Cellphone #: Address: Secondary Contact:

Commercial Roof Inspection Form

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

metal Duil~ing manufacturers Association

Right-of-Way Use Permit Application Instructions

Fence Application Package

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

SECTION STANDING SEAM METAL ROOFING

ISO Types 1-6: Construction Code Descriptions

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

Transcription:

City of Margate, Florida Building Department Minimum Permit Requirements For Roofing PERMIT APPLICATION COMPLETELY FILLED OUT, SIGNED AND NOTARIZED HOMEOWNER S ASSOCIATION NOTIFICATION FORM HOMEOWNER S AFFIDAVIT (when obtaining an Owner/Builder Permit) THE FOLLOWING DOCUMENTS MUST BE SUBMITTED IN DUPLICATE NOTICE OF COMMENCEMENT, WHEN OVER $2500.00 IN VALUE. UNIFORM ROOF PERMIT COMPLETELY FILLED OUT. WIND LOAD CALCULATIONS, SIGNED AND SEALED BY ENGINEER. HURRICANE PREPAREDNESS & PRECAUTIONS, SIGNED BY OWNER AND CONTRACTOR. HURRICANE PRECAUTIONS, SIGNED BY OWNER AND CONTACTOR. FIRE CLASSIFICATION PAGE (UL LISTING) NOTICE OF ACCEPTANCES HIGHLIGHTED. THE PERMIT APPLICATION WILL NOT BE ACCEPTED WITHOUT THE ABOVE MINIMUM DOCUMENTATION OTHER DOCUMENTS MAY BE REQUIRED DEPENDING UPON THE JOB CONDITIONS

Building Department High Velocity Hurricane Zones Required Owners Notification for Roofing Considerations Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics-workmanship: The workmanship provisions of Chapter 15 (High-Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High-Velocity Hurricane Zones) of the Florida Building Code, Building. (The roof deck is usually concealed prior to removing the existing roof system.) 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a buildup of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida-licensed engineer or registered architect to eliminate the attic venting, venting shall not be required. Owner's/Agent's Signature Date Contractor's Signature Date

City of Margate, Florida BUILDING DEPARTMENT HURRICANE PREPAREDNESS & PRECAUTIONS HURRICANE SEASON: JUNE 1 UNTIL NOVEMBER 30 PURSUANT TO SECTION 109.14.2.5 OF THE FLORIDA BUILDING CODE; IT SHALL BE A VIOLATION OF THIS CODE FOR AN OWNER OF REAL PROPERTY UPON WHICH CONSTRUCTION IS OCCURRING, OR ANY CONTRACTOR RESPONSIBLE FOR SAID CONSTRUCTION, TO HAVE ON THE PROPERTY LOOSE CONSTRUCTION MATERIALS THAT ARE NOT FASTENED OR SECURED TO THE GROUND OR ANY PERMANENT STRUCTURE. MATERIALS STOCK PILED ON TOP OF ANY STRUCTURE UNDER CONSTRUCTION SHALL BE PERMANENTLY INSTALLED BY THE PROPERTY OWNER OR CONTRACTOR UPON A HURRICANE WATCH, PROVIDED, HOMEOWNER, IN THE EVENT SUCH INSTALLATION CANNOT BE TIMELY COMPLETED, THEN THE PROPERTY OWNER OR CONTRACTOR SHALL: BAND TOGETHER THE CONSTRUCTION MATERIALS AND FASTEN THEM TO THE TOP OF THE STRUCTURE IN SUCH A MANNER SO AS NOT PRESENT A THREAT OF THEIR BECOMING AIRBORNE DURING SEVER WEATHER, OR REMOVE THE CONSTRUCTION MATERIALS FROM THE TOP OF THE STRUCTURE AND FASTEN DOWN TO THE GROUND, OR REMOVE THE CONSTRUCTION MATERIALS FROM THE JOB SITE, OR STORE THE CONSTRUCTION MATERIALS INSIDE AN ENCLOSED STRUCTURE. SECTION 109.14.3 OF THE FLORIDA BUILDING CODE: FROM JUNE 1 TO NOVEMBER 30 OF EACH CALENDAR YEAR (NATIONAL WEATHER SERVICE DESIGNATED HURRICANE SEASON), BUILDING MATERIALS SHALL BE LOADED ON A ROOF NO EARLIER THAN TWENTY (20) WORKING DAYS PRIOR TO THE PERMANENT INSTALLATION OF THOSE MATERIALS. NOTICES ISSUED BY THE NATIONAL WEATHER SERVICE OF A HURRICANE WATCH ARE DEEMED SUFFICIENT NOTICE TO THE OWNER OF REAL PROPERTY UPON WHICH CONSTRUCTION IS OCCURRING, OR ANY CONTRACTOR RESPONSIBLE FOR SAID CONSTRUCTION TO SECURE LOOSE CONSTRUCTION DEBRIS AND LOOSE CONSTRUCTION MATERIALS AGAINST THE EFFECTS OF HURRICANE FORCE WINDS. SECTION 101.3.1 OF THE FLORIDA BUILDING CODE: VIOLATIONS AND PENALTIES; ANY PERSON, FIRM OR CORPORATION WHO SHALL VIOLATE A PROVISION OF THIS CODE OR FAIL TO COMPLY THEREWITH, OR WITH ANY OF THE REQUIREMENTS THEREOF, SHALL BE GUILTY OF A MISDEMEANOR. EACH SUCH PERSON SHALL BE DEEMED GUILTY OF A SEPARATE OFFENCE FOR EACH AND EVERY DAY OR PORTION THEREOF DURING WHICH ANY VIOLATION OF ANY PROVISIONS OF THIS CODE IS COMMITTED OR CONTINUED, AND UPON CONVICTION OF ANY SUCH VIOLATIONS, SUCH PERSON SHALL BE PUNISHABLE BY A FINE OF NOT LESS THAN FIFTY (50) DOLLARS, OR BY IMPRISONMENT NOT EXCEEDING SIXTY DAYS, OR BY BOTH SUCH FINE AND IMPRISONMENT. I AM HEREBY NOTIFY EVERY ROOFING CONTRACTOR IN THE CITY OF MARGATE, THAT DURING HURRICANE SEASON, ROOFING CONTRACTORS ARE NOT ALLOWED TO LOAD ROOF TILES ON MORE BUILDINGS THAN THEY WOULD BE ABLE TO OFF LOAD IN A FORTY-EIGHT (48) HOUR PERIOD. IF, AT ANYTIME YOU HAVE LOADED MORE THAN THREE (3) ROOFS, YOU MUST NOTIFY THE BUILDING DEPARTMENT. TILES OFF LOADED MUST BE SECURED TO THE GROUND (STACK WIRED) OR PLACE IN THE GARAGE OF THE HOME. ALL JOB SITES MUST BE POLICED FOR LOOSE OBJECTS, AND DEBRIS MUST BE HAULED AWAY OR SECURED AS PER ABOVE. OWNER S NAME: OWNER S SIGNATURE: DATE: BY SIGNING THIS, I ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE ABOVE INFORMATION AND WILL COMPLY WITH THE FLORIDA BUILDING CODE REQUIREMENTS. CONTRACTOR S NAME: CONTRACTOR S SIGNATURE: DATE: BY SIGNING THIS, I ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE ABOVE INFORMATION AND WILL COMPLY WITH THE FLORIDA BUILDING CODE REQUIREMENTS.

Chapter 15 Section 1525 - HIGH-VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION SECTION 1525 HIGH-VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code Edition 2014 High-Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Attachments Required Permit Application Form See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation

Florida Building Code Edition 2014 High-Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Master Permit No. Process No Contractor's Name Job Address ROOF CATEGORY Low Slope Asphaltic Shingles Mechanically Fastened Tile Metal Panel/Shingles Mortar/Adhesive Set TiIe Wood Shingles/Shakes Prescriptive BUR-RAS 150 ROOF TYPE New Roof Reroofing Recovering Repair Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly Identify dimensions of elevated pressure zones and location of parapets.

Florida Building Code Edition 2014 High Velocity Hurricane Zone Uniform Permit Application Section C (low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as NA ) System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 or Calculations: P1: P2: P3: Max. Design Pressure, from the specific Product Approval system: Deck: Type: Gauge/Thickness: Slope: Anchor/Base Sheet & No. of Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Field: oc @ Lap, # Rows @ oc Perimeter: oc @ Lap, # Rows @ oc Corner: oc @ Lap, # Rows @ oc Number of Fasteners Per Insulation Board: Field Perimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter-Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or submit Manufacturers details that comply with RAS 111 and Chapter 16 Insulation Base Layer: Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s) & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: FT. FT. Parapet Height Mean Roof Height

Florida Building Code Edition 2014 High-Velocity Hurricane Zone Uniform Permit Application Section D (Steep Sloped Roof System) Roof System Manufacturer : Notice of Acceptance Number : Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): P1 : P2: P3: _ Steep Sloped Roof System Description Deck Type: Roof Slope: : 12 Type Underlayment: Insulation: Fire Barrier: Ridge Ventilation? Fastener Type & Spacing: Adhesive Type: Type Cap Sheet: Mean Roof Height: Roof Covering: Type & Size Drip Edge:

Florida Building Code Edition 2014 High Velocity Hurricane Zone Uniform Permit Application Section E (Tile Calculations) For Moment Based tile systems, choose either Method 1 or 2. Compare the values for M r with the values from M ƒ. If the M ƒ values are greater than or equal to the M r values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "'Moment Based Tile Calculations Per RAS 127 (P1: xλ = )I-Mg: =M r1 Product Approval M ƒ (P2: xλ = )I-Mg: =M r2 Product Approval M ƒ (P3: xλ = )I-Mg: =M r3 Product Approval M ƒ Method 2 Simplified Tile Calculations Per Table Below Required Moment of Resistance (M r ) From Table Below Product Approval M ƒ M r, required Moment Resistance * Mean Roof Height Roof Slope 15 20 25 30 40 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals For Uplift based tile systems use Method 3. Compare the values for F 1 with the values for F r. If the values for F 1 values are greater than or equal to the F r values, for each area of the roof, then the tile attachment method is acceptable. Method 3 Uplift Based Tile Calculations Per RAS 127 (P1: x L =x w:= )-W: x cos ᶱ = Fr1 Product Approval F1 (P2: x L =x w:= )-W: x cos ᶱ = Fr2 Product Approval F1 (P3: x L =x w:= )-W: x cos ᶱ = Fr3 Product Approval F1 Where to obtain information Design Pressure P1 or P2 or P3 RAS 127 Table 2 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope Job Site Aerodynamic Multiplier λ Product Approval Restoring Moment due to Gravity M g Product Approval Attachment Resistance M f Product Approval Required Moment Resistance M g Calculated Minimum Attachment Resistance F 1 Product Approval Required Uplift Resistance F r Calculated Average Tile Weight W Product Approval Tile Dimensions L= length W=width Product Approval All calculations must be submitted to the building official at the time of permit application. ᶱ

HURRICANE MITIGATION AFFIDAVIT Permit # Address Lot _ Block _Subdivision State of Florida: County of Broward: BEFORE ME, The undersigned authority, personally appeared Who, being duly sworn, deposes and says: (NAME OF Certifying Individual) I the undersigned certified individual for the re-roofing and Hurricane Mitigation, as prescribed in HB 7057 and FS 553.884, do hereby certify that I have personally inspected: The re-nailing of the roof sheeting and installed the secondary water barrier covering all joints in the roof sheeting with a minimum of a 4 wide strip of self-adhering polymer modified bitumen tape prior to covering with the approved underlayment. The installation of the metal connectors, clips, straps, fasteners, and additional structural elements using the prescriptive methods specified in sections 201.3.1 to 201.3.4 I fully understand that, by the Building Department s acceptance of this certification, which I am totally responsible for the correction of any problems which may arise at any time in the future. I further understand that, if any violations are discovered due to this certification, the Building Department may file an action against my certification with the appropriate licensing board. I agree to indemnify, and hold harmless, the City of Margate, Florida from any and all claims, judgments, costs, liabilities, damages, and expenses, including attorney fees, whatsoever arising in connection with the missed inspection. I hereby acknowledge that the statements herein contained are true and correct. Further, affiant sayeth naught. PRINT NAME OF CERTIFYING INDIVIDUAL On this, the day, of,, before me the undersigned Notary Public of the State of Florida, personally appeared SIGNATURE NAME OF CERTIFYING INDIVIDUAL CERTIFICATION NUMBER. Whose name is subscribed to the within instrument, and he acknowledges that he executed it LICENSE TYPE NOTARY PUBLIC, STATE OF FLORIDA SEAL

City of Margate, Florida Building Department Homeowner s Association Notification Form Name Address Unit number Association: PLEASE CHECK ALL THAT APPLY I live in a residential community with a homeowners association I have notified my homeowners association of proposed improvements I live in a condominium with a homeowners association I have notified my homeowners association of proposed improvements I do not live in a residential community with a homeowners association Your permit application will not be accepted without this information Owner Signature Date Owner Signature Date Print name Print Name

City of Margate, Florida Building Department DURING A HURRICANE WATCH & BEFORE THE ONSET OF HURRICANE VELOCITY WINDS YOU ARE REQUIRED TO SECURE THIS JOB IN ACCORDANCE WITH THE BROWARD COUNTY ADMINISTRATIVE PROVISIONS OF THE FLORIDA BUILDING CODE SECTION 109.12 All loose objects In exposed outdoor locations shall be lashed to rigid construction or shall be stored in buildings. Florida Building Code Broward County Administrative Provisions Section 109.14.2.4 NOTICES ISSUED BY THE NATIONAL WEATHER SERVICE OF A HURRICANE WATCH ARE DEEMED SUFFICIENT NOTICE TO THE OWNER OF REAL PROPERTY UPON WHICH CONSTRUCTION IS OCCURRING, OR ANY CONTRACTOR RESPONSIBLE FOR SAID CONSTRUCTION, TO SECURE LOOSE CONSTRUCTION DEBRIS AND LOOSE CONSTRUCTION MATERIALS AGAINST EFFECTS OF HURRICANE FORCE WINDS This includes but not limited to: 109.14.2.1 Road Right-of-Way shall remain clear of construction waste and trash 109.14.2.2 Waste and Trash Enclosures Temporary Toilets 109.14.2.3 Loose Construction Debris Forms and Construction Materials 109.14.2.5 Roofing Tile and Materials Construction Shacks 109.14.3 Loading of Roof Tile Temporary Electric Service Poles AND PROTECT ALL GLASS AREAS