CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

Similar documents
INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

STORED PRESSURE STAINLESS STEEL

Morrison Bros. Co. General Product Specifications

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

System Accessories Pricing. Page 0 Effective 7/02

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

TECHNICAL DATA. Dry 122a. November 12, 2013

Stainless Steel Valves For the Sanitary Industries

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

Baumann Flexsleev Sanitary Control Valve

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Stainless Steel Single and Dual Circulation Kits

Baumann Mikroseal Control Valve

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

RESERVDELSLISTA NORMFINISH DP14

Many Products...One Source

4 Posiflow Proportional Solenoid Valves

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

KNC Model 3666 Automatic Pressure Calibration System

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Self Purging Liquid Trap (SPLT ) User s Manual

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Nordson Automatic Spray Gun Support Kits

MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC

Certificate of Conformity Certificate num. Registration date Version Valid until

MODEL T200-F18 MODEL T125-F18 Finish Nailers

POWERS Controls No. 4 Pneumatic Damper Actuator

ROUGHNECK II Pumpless Drain

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Quick response concealed horizontal sidewall sprinkler

NITROUS TRANSFER PUMP INSTRUCTIONS

KELGATE BRAKES - price list for 2014 Page 1

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Multipurpose Ball Valves

Micro Motion Model D and DL Coriolis Flow and Density Meters

167D Series Switching Valves

Screw Plug Immersion Heaters

1/29/2008 DR125 / DR150. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PARTS AND PRICES ARE SUBJECT TO CHANGE 1 of 55

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

James M. Pleasants Company

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Model 5600SE Downflow

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

VALVES FOR REFRIGERATING SYSTEMS

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

PRESSURE REDUCING CONTROL VALVE

HOSE, TUBE, AND PIPE CLAMPS

Midwest Industrial Tanks

IOM SERIES 820-E/P Electro-Pneumatic Positioner

Cylinders Series 40. Double acting, cushioned, magnetic ø (DIN/ISO 6431)

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

needle valves Needle Valves Index At a Glance 1

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

SHOWERS SHOWERS

Standard Bills of Materials Commonly Ordered Models Only

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Rated Burst Pressure 200 Series: 2.5 : 1 H200 Series: 4 : 1

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Valve systems Base plates, according to standard ISO Brochure

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

AUTOMATIC CHANGEOVER MANIFOLD Series 915

relief valves 500 Series Adjustable Popoff & Inline Relief Valves 0.5 to 150 psig (10 bar)

kymanual or Automatic - it s your Choice

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Working Pressure up to 630 bar / 9135 PSI

Automated Lubrication Systems Parts & Accessories

Scraper Passage Indicator. Electrical Indicator. Features

P/N 90-FM200M FM-200 ECS

TBi Industries. MIG / MAG Welding torches TBi Expert 0. 1

Parts. Ultra 395/495/595t Ultra Max II 490/495/595t V 120 VAC psi (228 bar, 22.8 MPa) Maximum Working Pressure.

1/29/2008 DR50. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 45

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Baumann Way Bronze or Stainless Steel Control Valve

Number Wheeler P/N Description Set Rex P/N Notes Base 1 J Support, Right 1 J Support, Left 1 J Nut (M8)

WD600 STEAM TRAPS. Thermodynamic Steam Trap

Valves dimension of pressure (lbs) ANSI2500 ANSI1500 ANSI900 ANSI600 ANSI300 ANSI150. Inch. from 1/2 up to 6

REPAIR AND MAINTENANCE MANUAL

SERVICE MANUAL NO for AMEREX HALOTRON I HAND PORTABLE CLEAN AGENT FIRE EXTINGUISHERS (FOR NON-RESIDENTIAL APPLICATIONS)

Complete Systems & Parts Automatic Oiler & Grease Bank

Cooling system components, removing and installing

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

Transcription:

The technical data described herein is for components of the Minimax Fire Products MX 30 Clean Agent System. For design, installation, and operation instructions, refer to the latest edition of the original source documents: Installation and Service Manual (Part No. 88937), Design Manual (Part No. 889334), and Operation Manual (Part No. 88935). Page of 6. DESCRIPTION The Minimax MX 30 Fire Extinguishing System uses 3M TM Novec TM 30 extinguishing fluid that is stored in the system s extinguishing agent container(s) until system activation. The container assembly includes a welded or seamless steel cylinder filled with Novec TM 30 fluid, assembled with the following components: Cylinder valve with burst disc, pressure gauge, protective neck ring, protective cylinder cap and valve cap. Five cylinder sizes available for 360 psi (5 bar): 60, 40, 80, 390, and 500 lbs. (, 5, 06, 47, and 80 l). Three cylinder sizes are available for 75 psi (50 bar): 0, 390, and 500 (80, 40, and 80 l) 80, 390, and 500 lbs. (06, 47, and 80 l) cylinders are available with Liquid Level Indicators for the 360 psi (5 bar) system. Cylinders are designed, manufactured, and labeled in accordance with the US Dept. of Transportation Standard DOT 4BW-500, DOT 3AA-90, and TC (Transportation Canada - 360 psi (5 bar) system only). Cylinders can only be installed in the upright position. To create the pressure necessary for the agent to be released, the extinguishing agent container is superpressurized with nitrogen at a pressure of 360 psi (5 bar) or 75 psi (50 bar). Cylinder fill density is dependent on the area of protection size. Agent concentration varies due to the expected class of fire (A, B, or C). Each cylinder is equipped with a special high-speed opening cylinder valve: Operates according to the differential pressure principle and has a piston and a brass housing. Includes a burst disc to protect from excessive pressure. Includes a pressure gauge for indication of the filling pressure. The valve is appropriate for high discharge rates and makes the extinguishant discharge possible within 0 seconds. Available in the nominal sizes -/ for the 60 lb and 40 lb. cylinder, and for 0, 80, 390, and 500 lb. cylinders. An optional manual release assembly with pneumatic discharge pressure switch can be ordered separately for installation in the piping: The pneumatic discharge pressure switch is required with manual release installation per NFPA 00. The status of the pressure switch can be monitored by the fire agent release control panel. A cylinder nameplate label is attached to the extinguishing agent container: Contains maintenance and filling information, as well as information about the filling quantity. A UL Listing label and FM Approval label are also attached to the cylinder. Protective caps are used to protect sensitive components (e.g. valves) of the extinguishing agent containers: Protects the valves from damage during transport. NOTE: The protective valve caps must be attached before each transport. An installation clamp is required to be ordered with each container assembly (available separately): The cylinder must be attached to a wall using the designated installation clamp. NOTE: System detection is controlled by an approved system release control panel with compatible detections. LISTINGS AND APPROVALS UL Listed: Clean Agent Extinguishing System Unit FM Approved: Clean Agent Fire Extinguishing System Minimax Technical Data may be found on Minimax Fire Products Web site at http://www.minimaxfp.com/. The Web site may include a more recent edition of this Technical Data Page. Form No. F_004 6.04.4 Rev 6. Replaces Form No. F_004 Rev 4. (Replaced part no.s 9 454, 9 455, & 88930 in Table )

Page of 6 3. technical data Minimum and Maximum Agent Storage Temperatures: 0 F to F (-8 C to 50 C) Minimum and Maximum Temperatures of Protected Spaces per UL and FM: 60 F to 80 F (5.6 C to 6.7 C) Cylinder Specifications Fill Density: Min. 5 lb/ft 3 (400 kg/m 3 ), Max. 74.9 lb/ft 3 (00 kg/m 3 ) at 69.8 F ( C) NOTE: The accurate filling quantity depends on the necessary extinguishant quantity and the layout of the piping. Valve Specifications Working Pressure: 360 psi (5 bar) or 75 (50 bar) at 70 F ( C) Max. Working Pressure: 508 psi (35 bar) or 870 (60 bar) at F (50 C) Response Pressure at Bursting Disc for 360 psi (5 bar) System: 900 psi (6 bar ) at 68 F (0 C) Response Pressure at Bursting Disc for 75 psi (50 bar) System: 76 psi (88 bar) for valves, 9 psi (89 bar) for -/ valves at 68 F (0 C) Gauge Specifications Agent: FK-5-- (Novec TM 30) 360 psi (5 bar) system: Maximum Pressure: 75 psi (50 bar) Indicating Range: 0 to 508 psi (35 bar) 75 psi (50 bar) system: Maximum Pressure: 60 psi (80 bar) Indicating Range: 0 to 870 psi (60 bar) Gauge Nominal Size: (50 mm) Accuracy Class:.6 Material Standards Cylinder: Welded Steel, Powder Coated Red, DOT Standard 4BW-500 or Seamless Steel, Powder Coated Red, DOT Standard 3AA-90/TPED Protective Neck Ring: AISI 05 Hot Rolled Steel, Powder Coated Black Cylinder Valve: Housing, Adapter, Screws: Brass Seal Retainer: Brass O-ring/Seal of Seat: NBR Bursting Disk: Nickel Spring: Steel Gauge: Aluminum Liquid Level Indicator Stem: Brass O-Ring: Buna N Float: Ceramic Protective Cap: PVC Tape: Painted Steel Protective Cylinder Cap: AISI 06, Hot Rolled Steel, Powder Coated Black Installation Clamp: Steel Ordering Information The cylinders are filled according to the ordering designations. Extinguishant cylinders are completely assembled and filled. For a complete Single Container System, the following must be ordered separately: release devices, optional manual release assembly with pneumatic discharge pressure switch, discharge nozzles, hose or NPT connections, installation clamp, and warning signs. An approved release control panel with compatible detection system is also required. Gauge Indicating Range: I. Pressure at minimum temperature 0 F (-8 C) II-III. Pressure from 90% to 0% from charging pressure at 70 F ( C) IV. Pressure at max. temperature F (50 C) Gauge Color Marked: 0 to I...Recharge I to II...Red II to III...Green III to IV...Red IV to max...overcharge Figure : Pressure Gauge Markings

Page 3 of 6 4 6 7 8 6 TABLE : MX Fire Extinguishing System Components Item No. Description Part No. Pressure Gauge 360psi (5 bar) 9 097 75psi (50 bar) 9 099 3 5 3 0 9 8 9 5 4 7 Contact Pressure Gauge / Low 360psi (5 bar) NO 88 9300 pressure Switch (Optional) 75psi (50 bar) NO 88 930 Hose -/ 90º Bend 9 075 90º Bend 9 076 3 Swivel Adaptor -/ NPT 756 NPT 7563 4 Check Valve 9 07 5 Electric Release Device 88 933 6 Pneumatic Release Device 88 7669 7 Pneumatic/Manual Release Device 88 7670 8 Manual Release Device 88 7668 4 88 7834 9 Pilot Hose 39 88 7835 59 88 7836 0 Pilot Hose Adaptor 88 7644 Pressure Malfunction Safety Assembly 600 Screw Reset Tool 7096 Clamp for 60lb / 40lb 9368 3 Extinguishing 80lb / 390lb / 0lb Agent Cylinder / 500lb 88 7639 4 Hex. Nut DIN934-M-B-GAL ZN/B 8 386 5 Washer DIN5-B3ST GAL ZN/B 0 9886 6 Protection Cap 7 Ring-Protection Cap 8 Extinguishing Agent Cylinder 9 Siphon Tube Figure

Page 4 of 6 Figure 3 Pressure at 70º F (0º C) 360 PSI (5 bar) 75 PSI (50 bar) Nominal Volume With Liquid Level Indicator 360 PSI (5 bar) TABLE : MX 30 Cylinder Part Numbers and Dimensions Part No. Valve Type A / A5 A B C D E Amount Filled Min. Max. Empty Weight 60 lb 9 447 40.8 3. 5.8 0 4.75 0 lbs 58 lbs 88 lbs 40 lb 88 909 65.4 47.8 7.5 0 4.75 46 lbs 37 lbs 08 lbs 80 lb 88 9 6.4 40.9 7.5 6 6 94 lbs 80 lbs 90 lbs 390 lb 88 93 74.5 54.0 4. 6 6 30 lbs 388 lbs 9 lbs 500 lb 9 050 86.0 65.5 5. 6 6 59 lbs 476 lbs 33 lbs 0 lb 88 859 55.4 34.9 3.6 6 6 7 lbs lbs 8 lbs 390 lb 88 8593 74.3 53.8 4.4 6 6 4 lbs 370 lbs 89 lbs 500 lb 88 8595 88.0 67.5 5. 6 6 59 lbs 476 lbs 395 lbs 80 lb 9 45 6.4 40.9 7.5 6 6 94 lbs 80 lbs 0 lbs 390 lb 9 45 74.5 54.0 4.4 6 6 30 lbs 388 lbs 5 lbs 500 lb 9 453 86.0 65.5 5. 6 6 59 lbs 476 lbs 86 lbs Extinguishing agent cylinder complete with valve, ciphon tube, ring and protection cap, without extinguishing agent. All dimensions are appoximate, variations due to manufacturing tolerances are possible.

Page 5 of 6 9 7 0 8 6 5 4 3 Example of a Complete MX 30 Fire Extinguishing Single Container System Figure 4 Item No. TABLE 3: SYSTEM COMPONENTS FOR A COMPLETE MX 30 Single Container System with Electric Release Device Extinguishing Agent Container Installation Clamp** 3 Pressure Gauge 4 Cylinder Valve with Burst Disc 5 Release Device, Electric** Description 6 Release Device, Manual (optional, also see Item 9)** 7 Pneumatic Discharge Pressure Switch (optional)** 8 Hose (90 Shown)** 9 Pipeline** 0 Discharge Nozzle** **Ordered separately. Required if manual release device is installed (available as part of the manual release assembly). NOTE: Additional components are required for a Multi Container System.

Page 6 of 6 5 3 4 Figure 5: Example of a Complete MX 30 Fire Extinguishing Multi Container System Item No. Pneumatic Release Device Check Valve 3 Pilot Line TABLE 4: ADDITIONAL SYSTEM COMPONENTS REQUIRED FOR A MX 30 Multi Container System*** Description 4 Pilot Line Adapter (one required for connecting each pilot line end and for connecting each pilot line safety valve) 5 Pressure Malfunction Safety Assembly ***Components required in addition to the items indicated in Figure 3 for a Single Container System. Form No. F_004 6.04.4 Rev 6. Replaces Form No. F_004 Rev 4. (Replaced part no.s 9 454, 9 455, & 88930 in Table )