MAIN STAGE TECHNICAL SPECS - HALL #1



Similar documents
Schouwburg & Filmtheater Agnietenhof Venue: 4000 AN Tiel. info@agnietenhof.nl techniek@agnietenhof.nl

HEBDEN BRIDGE PICTURE HOUSE TECHNICAL INFORMATION FOR HIRERS UPDATED OCTOBER CAPACITY. Stalls: 257 Seats per row: 22(Max)

SHUBERT THEATER 247 College Street, New Haven, CT

STAGE SPECIFICATIONS. Newberry Opera House

PRODUCTION SPECIFICATIONS

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

TECHNICAL RIDER

Théâtre de Suresnes JEAN VILAR presents RAYAHZONE

TECHNICAL SPECIFICATIONS.

Event Planner/Venue Specialist Phone:

Reynolds Performance Hall Facility Regulations and Fee Schedule

Art Basel Miami Beach Dec Booth Design Regulations

TECHNICAL SPECIFICATIONS Paramount website: Paramount

Contacts. The Space. Lx Kit List. Sound Kit List. Stage Management. Health & Safety Policy

UCLA Department of World Arts and Cultures Glorya Kaufman Dance Theater (Room 200) Technical Information

Les Docks / Av. de Sévelin Lausanne! Technical Rider

Douglas J. Cardinal Performing Arts Centre. Information and Technical Specifications

Technical Specifications Lyric Theatre Belfast Danske Bank Stage

Stadsschouwburg Amsterdam Rabozaal website technical rider - 13th of may 2011

Ministry of the Environment Decree on accessible building

Introduction. Pre-Arrival. Arrival & Car Parking Facilities. Main Entrance, Reception & Ticketing Area

Technical Specifications Version

Lower Level (Level L) Exhibit Halls A, B & C

ADA HOTEL SITE INSPECTION CHECKLIST

Access Statement for Wood View Guest House

Theater De Meervaart Amsterdam Red Hall (Rode Zaal) and Blue Hall (Blauwe zaal)

Hotel Accessibility Pack

TECHNICAL INFOS CAPACITY 2 STAGE 2 TECHNICAL ROOF GRID (NOT YET AVAILABLE) 2 STAGE CURTAINS 3 FOLLOWSPOTS PLATFORM 3 ELECTRIC INSTALLATIONS 3

Hotel Accessibility Pack

The Theatre Dictionary

L ORATORIO D AURELIA. Technical Rider. Administration: Didier Bendel Cell phone:(0049) (0) didierbendel@gmx.

Horizontal Cable Systems

TELESCOPE Motorized Lighting Suspension

FOOTHILL COLLEGE FINE ARTS FACILITIES OFFICE

Production Services Department

Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.

J. W. ENNIS AUDITORIUM CENTENNIAL SECONDARY SCHOOL WELLAND, ONTARIO THEATRE TECHNICAL INFORMATION MARCH 29, 2013

Access Statement Atlantic Tower Liverpool ( )

1 STAR HOTELS. Caballero Errante Europa Ibis Budget Madrid Vallecas Ibis Madrid Valentín Beato Sancho

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION SECURITY SYSTEMS

ACCESSIBILITY STANDARD

MEETING PACKAGES 400 LEVEL

Challacombe Close Hutton Mount, Brentwood.

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Planning Information. Passenger and Freight Elevators.

Hotel accessibility pack

How to secure your property after a disaster

Aluminium systems profile selection

Visual guidelines for student charges

Disabled Access Guide

Rental Control During and After Las Vegas Events

CORONET LONDON / Technical Information Pack (Updated - 1 st January 2015)

Artist: Michael and Amy Rider: Corporate - Grand Pianos

Rack Installation Instructions

Blair School of Music

New York, Dean. Price 182,500

Achat 208 HL / 208 HR passive mid-range speaker. user manual

TECHNICAL SPECIFICATIONS

Sweet Adelines Microphone and Sound System Guidelines

Laboratory Construction Guidelines Vicon MX Systems

Residential Decks. Planning and Development Services Department

CDG 10 X 20 Tradeshow Booth Exhibit Setup Instructions

31 Linden Lane Kirby Muxloe Leicestershire LE9 2EG

Service Level Agreement

3rd Annual Design Drafting Contest

The White House 15 Whirlow Park Road, Sheffield. Park Estates

accessibility standard

PRO PANELS the artist s choice in display designed by artists, for artists. voice: fax:

A1.5 Classroom Standards

GenStore Archive Cabinet

SIMULATION PRE-INSTALLATION GUIDELINES CONTRACTOR REQUIREMENTS FOR ROOM PREPARATION

THEATRE USER INFORMATION GUIDE

Community Usher Handbook

SERVER ROOM CABINET INSTALLATION CONCEPTS

OFFERING THE SELF-BUILDER NEW CHOICE

Client of Colvin Houston 27 The Shores, Skelmorlie PA17 5AZ

AlonA Hotel Access Statement

V1504 Vertical Platform Lift OWNER S MANUAL

Adress: Teatertorvet DK Horsens Denmark. Postal adress: P.O.Box DK 8700 Horsens. Phonenr, etc..

Walking and Working Surface Checklist:

BLADE S-MAX Cabinet for Blade Server

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Introduction. Meeting Spaces. Hynes Audio Services

OCFRD TENT STANDARD This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations

Theater One (Upper level)

CENTER THEATER TECHNICAL SPECIFICATIONS 404 SEAT PROSCENIUM THEATER WITH FLY LOFT

Site Plan. Parking. Main Auditorium. Large Auditorium. Lobby. Parking. Small Meeting Room. Dock & Broadcast Truck Bay

DE Frame with C Series Sidelight

ITEM DESCRIPTION SPECIFICATION TENDER OFFER

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

The Swingle Singers RIDER PART 1: TECHNICAL REQUIREMENTS A Cappella Show

Transcription:

MAIN STAGE TECHNICAL SPECS - HALL #1 Proscenium: Apron: Stage: Fly bars : - Height:...28' (08.23m) - Width:...45' 11"(13.45m) - Depth:...8' 11" (02.72m) - Width:...52' 2" (15.90m) - Height:...3' (00.91m) - Distance between center line and stage right wall:...42' (12.80m) - Distance between center line and stage left wall:...38' (11.58m) - Maximum width:...66' (20.12m) - Maximum depth:...42' 6" (12.95m) - House curtain to back wall:...32' 6" (09.88m) - Proscenium to house curtain:...1' (00.30m) - House curtain to the edge of the stage:...10' (03.05m) - Width of system pipes:...56' (17.07m) - Height of the system pipes:.29 (8.84m) - Height underneath of the catwalk (stage right):...27' 1" (08.26m) - Height underneath of the catwalk (stage left):...27' 4" (08.36m) - Height of the catwalk (control fly): 29 10" (09.09m) - Height of the grid:...58'9" (17.68m) - Free height under the grid:...55' (16.77m) - Height under the pipes:...see the plan - Distance between stage and beginning of balcony:...42' (12.81m) - 34 single purchase system pipes are suspended by 6 steel cables with a maximum safe load capacity of 1 000 lbs (454 kg) each. The controls are manual and are located at the catwalk level on stage left. - 2 double purchase system pipes are located up stage for German masking. - The system pipes are made of tubular steel, 1.50" in diameter (3.81 cm) and 44' (13.41 m) long. - Rigging points above the grid may be used for hanging (see the plan).

Loading platform Platform: Accessible via Brazeau lane behind the Theater. This is an exterior free-standing steel platform that gives access to an elevator with a load rating capacity of 5000 pounds (2272 kg). The elevator can be stopped at street, stage, or basement level. - Height (above street level):...4' 4" (01.32m) - Width:...8' (02.44m) - Length:...10' (03.05m) Service Elevator: - Width:...7' 7" (02.31m) - Height:...8' 1" (02.46m) - Length:...12' (03.66m) Exterior door of the elevator : - Width:...7' 7" (02.31m) - Height:...7' (02.13m) Bringing in the scenery : If the scenery cannot be brought in by way of the elevator, it can be brought in through the main entrance on St-Denis Street (through the lobby). Door measurements: - Height:...7' 11" (02.97m) - Width:...5' 05" (02.39m) (Maximum space for scenery is 7 '11" x 5') Please note that there are no stairs between the entrance on St- Denis Street and the stage. Approximate distance: 150' (45.72m). Only equipment too big for the service elevator will be authorised to enter by the main entrance on St-Denis Street. Up Right lift (Genie) An Up Right lift (Genie) is available. Maximum height: 32 (9.76m)

Dimensions of Hall #1 (approximate measurements ): - Sound/ Light technical pit:...48 (14.63m) from the stage. There are different configurations. 1. Option # 1 : 10'6" x 7 6 (3.23m x 2.32m) 2. Option # 2 : 14' x 7 6 (4.27m x 2.32m) 3. Option # 3 : 17'5" x 7 6 (5.34m x 2.32m) 4. Option # 5 : 20'9" x 7'6" (6.37m x 2.32m) Option #4: Is the standard configuration. If you would like to modify the pit, please notify the Theater management before the tickets go on sale. Extra charges may apply. Option Row Seats L 4 to 7 1 M 4 to 7 N 4 to 7 L 12 to 7 2 M 12 to 7 N 12 to 7 L 4 to 11 3 M 4 to 11 N 4 to 11 L 12 to 11 4 M 12 to 11 N 12 to 11 -You can have a second Lighting Control Booth: 110 (33.53m) from the stage (located at the back of the hall, on house right). This configuration is used when the producer has chosen Option #1 for the sound configuration. - Balcony rail (First F.O.H): - Length:...55' (16.76m) - Distance from the stage:...42' (12.81m) - Angle to the stage:...13 degrees - Second F.O.H. catwalk (24 lekos): - Height:...46' 6" (14.17m) - Length:...93' (28.35m) - Angle:...38 degrees

Spotlight position: - Two 2K, Aramis from Robert Julia - Angle of 22 degrees to the stage. It is located at the back of the house, second section of the balcony. It is possible to move the follows to the middle of the balcony if the second balcony is not on sale. Second F.O.H.: Dimmers: 24 1K Robert Julia lekos (611 SX (11.5 ) model) 24 2K ETC dimmers (Sensor SP 1220C, TWL (DMX) model) Lighting console: The St-Denis Theater is equipped with an ETC lighting system, a 24/48 inputs Express model, for shows needing a minimum of equipment. In-house electrical wiring: - Sound: There is a multi-wire cable (snake) installed permanently between the sound control console and the stage. There are 50 inputs and 10 outputs available around the stage. - Lighting: The stage can be connected to the lighting control board using a DMX system. Clear com: Clear com>> lines haves been installed permanently. However, you must bring your own system.

Sound System : The presence of Solotech s head sound technician is mandatory; the costs will be charged to the producer on the final bill. Main sound system: 18 L-Acoustics KUDO, suspended, 09 x per side (flown) 8 L-Acoustics SB28 (ground-stacked, cardoid pattern, 4 per side) 4 L-Acoustics MTD115 (ground stacked, stereo fills, 2x per side) System amplified by 12 LA8. Backup systems: 4x Meyer M1D at edge of stage (front fills) 3x MEYER M'ELODIE fills, suspended under balcony floor 2x Meyer UPA-2P outside ground floor suspended fills 2x Meyer UPA-2P outside suspended balcony fills 2x MEYER MSL2, + amplification, on the catwalk, fills in the second balcony section System managed by a MEYER GALILEO 616. House sound delay: Théâtre St-Denis has a delay system consisting of 4 UPM-1P cabinets (Meyer), which are installed at ground level under the balcony, and 2 other cabinets on each side of the balcony. The system is already calibrated for the room. The tenant has to provide an audio feed that will be broadcast to the hearing impaired system and to the house HD monitors. Dressing rooms: - 1 lounge-dressing room with a shower and a bathroom, at stage level. - 4 dressing rooms that can accommodate 4 people each, with showers, at stage level. - 2 dressing rooms that can accommodate 8 people each, with showers and bathrooms, located below stage level. - 3 individual dressing rooms with showers, located below stage level - the dressing room corridor has a lunch counter with microwave and fridge Paging system: There is a paging system in all dressing rooms (stage floor and below stage level). This system allows the performance in progress to be heard as well as calls from the stage manager.

Paging system for dressing rooms and hearing impaired system: There is a paging system in all dressing rooms (stage floor and below stage level). This system allows the performance in progress to be heard as well as calls from the stage manager. There is also an FM system (frequency 100.1) for the hearing impaired. Only one signal should be sent by the F.O.H. sound console. It is automatically broadcast to both networks. Make-up and hair dressing: A section below stage level that can accommodate 6 people is reserved for make-up and hair. Lighting and mirrors are supplied, but you must supply your own chairs. Costume storage: There is a costume storage area located below stage level. Stage entrance: There is an entrance available for the artists on stage right, on Brazeau Street behind the Theater. This door is kept locked at all times with a code, which you will be given a few days prior to set up. Production Office: - An office is available for the production, at stage level, next to the dressing rooms. - There is one permanent fax line and one permanent telephone line for the exclusive use of the production. To obtain access to long distance calling, a request must be submitted to the technical director in order to get a code. - Several other telephone lines are available in the production office, either for faxes or additional phones. Arrangements should be made with Bell or Videotron for connecting these lines ahead of time. Internet access: - There is high-speed WIFI Internet access only. The technical department will give you the access code upon your arrival.

Stage floor: -The stage floor is black-stained birch. -It is strictly forbidden to insert screws or nails into the stage floor. Orchestra pit: The orchestra pit is available for use. However, additional charges should be foreseen for its conversion, which involves the removal of 59 seats from the floor section, namely all seats in rows AA, BB and CC. You will find a plan of the orchestra pit and its dimensions on page 10. Piano: A 5-foot Conservatory C3 Yamaha grand piano is available upon request. Only our tuner may tune the piano. The costs will be billed to the producer. The technical department will determine your tuning needs and schedule with you. Laundry: - 2 washing machines and 2 dryers are at your disposal. - The necessary wiring for one additional washing machine and two additional dryers is already in place. - Located below stage level.

Stage Curtains - Hall #1 House Curtain: Leg: Borders: Back drop: - Black velvet - The controls positions are: A for the borders B for the curtain - The curtain is opened horizontally by means of a counterweight system and vertically on traveler tracks. - Quantity:...5 sets - Height:...26' (07.92m) - Width:...22' (06.71m) - Black velvet - Quantity:...7 - Height:...12' (03.66m) - Width:...52' (15.68m) - Black velvet - Height:.....26' (07.92m) - Width:.....55' (16.77m) - Black velvet Black travellers: - Height:...26' (07.92m) - Width:...55' (16.77m) - Black velvet Note: All curtains, including the main one, are detachable and can be moved.

Electric Power - Hall #1 Lighting: There is a power distribution panel underneath the stage, easily accessible through a trap door in the stage floor, on stage left. 800 amps 120.208 V 3 phases Note: An additional panel is available. If needed, check with the technical supervisor. Sound: A power distribution panel is available at stage level, on stage right: 200 amps 120.208 V 3 phases Mobile video and sound: There are 2 power distribution panels located outside the Theater, above the dressing rooms, accessible from the parking lot: 200 amps 120.208 V 3 phases The outside sound panel is linked to the inside sound panel. Note: More electric power can be provided upon request. However, the producer must hire an electrician recommended by the technical supervisor of the St-Denis Theater.

Théâtre St-Denis 1 Scène/Stage C D E F G H J K L M N O P R S T U B A K L M N O P R S T U V D E F G H J D E F G H J K L M N O P R S T U V K L M N A C D E O P R S F G B H J T U Balcon/Balcony