Car Park Management Program PP-20/50



Similar documents
Hotel room management software

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

CMS Central Monitoring System

PNOZmulti Configurator V8.1.1

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

Licenses of savic-net for Integrated Building Management System, and for FDA Title 21 CFR Part 11 Compliance

ASTROW HR. Installation & Operation & Programming MANUAL

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide

Software Table of Contents

Centaur s Anti-Passback Monitoring Software. Operator s Manual V4.0

Disturbance Recoder SPCR 8C27. Product Guide

SOFTWARE EasyComm (Code ) USER S MANUAL (Code M /00 - A) CIRCUTOR, S.A. All rights reserved

COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

H ARDWARE C ONSIDERATIONS

Doors in a Network Environment

Item Minimum Required Recommended Notes

How To Connect A Port Replicator With An Ethernet To A Usb Port From A Usb Device

Introduction 1-1 Installing FAS 500 Asset Accounting the First Time 2-1 Installing FAS 500 Asset Accounting: Upgrading from a Prior Version 3-1

Prerequisites Guide. Version 4.0, Rev. 1

Operating Software Service Tool

OPEN PARK. Automatic Number Plate Recognition that works worldwide including Egypt Number plates

Operating Instructions

Time Attendance V1.0

Application Note Connect to a Rockwell PLC over Netbiter Remote Access

Integrated Security System

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

Patriot Hardware and Systems Software Requirements

HC Emission Protected Security Workstation

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

About Parallels Desktop 7 for Mac

WINSCRIBE HARDWARE SPECIFICATIONS

VMWare Workstation 11 Installation MICROSOFT WINDOWS SERVER 2008 R2 STANDARD ENTERPRISE ED.

SMS (Server Management Software) Digital Video Recorder. User s Manual

YZP : SAUTER Vision Center

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

Table 1. Requirements for Domain Controller. You will need a Microsoft Active Directory domain. Microsoft SQL Server. SQL Server Reporting Services

DIGICLIENT 8.0 Remote Agent Software

AS-525. AxTrax Access Control Management Software. Software Manual

ENTBUS PLUS SOFTWARE FOR ENERGY MONITORING AND RECORDING INSTALLATION AND OPERATING MANUAL

EZ-View Network Communications Guide

LobbyWorks VMS Configuration and Technical Requirement Survey

User and maintenance manual (client Web and Web services)

L11 - New Techniques to Increase Efficiency with PanelView Plus 6 Applications Wil Mattheis Commercial Engineer

#65 4GHGTGPEG")WKFG #FXCPEGF"6GTOKPCN"5QHVYCTG 8GTUKQP"502 HQT"%QPVTQNNGT/#% Catalog # Rev.02

Figure 1: RotemNet Main Screen

Minimum Software and Hardware Requirements

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version

Quick Start Guide. DVR DS-7200HWI-SH Series DVR. First Choice For Security Professionals

Access Professional Edition Selection Guide

PARTNER ACS R4.0 Remote Administration R4.0. Getting Started

DCS110 CATVisor COMMANDER

Temperature & Humidity SMS Alert Controller

inforouter V8.0 Server & Client Requirements

BabyWare Imperial PC Software

HyperAccess Access Control System

Getting Started. Document Overview. What is Faronics Power Save? Installation Process

Straton and Zenon for Advantech ADAM Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

Analyzer 2.0. Installation Guide. Contents

Phone: Fax: Web: info@ctiautomation.net

SoundLAB Software Download Software from the Bogen website:

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION

Quick user guide for the Vista Quantum 960H range of DVRs, models included

I/A Series Information Suite AIM*DataLink

SW 6000 Conference Management Software

Rev GSM base station. Installation instructions

Remote Deposit Capture Installation Guide

Premium Server Client Software

IXP120 Alarm Monitor Utility

User Manual Version 15.1

Comparing Free Virtualization Products

Licenses of savic-net for Integrated Building Management System for FDA Title 21 CFR Part 11 Compliance

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

Locker Rental Software

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

Windows administration for Adash Software

AdminToys Suite. Installation & Setup Guide

INFUSION BUSINESS SOFTWARE Installation and Upgrade Guide

Requirements Document for ROI Print Assessment/Print Manager

Transmitter Interface Program

User's Guide. Dosimeter Configuration Software ADR-1/60

EnerVista TM Viewpoint Monitoring v7.10

AXIS 262+ Network Video Recorder

SMS GSM Alarm Messenger

System requirements for MuseumPlus and emuseumplus

VisiCount Installation. Revised: 8/28/2012

How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci

Z-SYSTEMS ROUTER CONTROLLER DOCUMENTATION V1.0

Manual. Danfoss Central Station Communications Software Version 3

Ignify ecommerce. Item Requirements Notes

Scan System (F) Operation Guide Set-up Edition

Connecting your Omega/BetaPAT PLUS to a PC via a USB

Instruction manual. testo easyemission Software

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

Product Description. Licenses Notice. Introduction TC-200

Minimum Hardware Specifications Upgrades

User's Guide. Using RFDBManager. For 433 MHz / 2.4 GHz RF. Version

Transcription:

Car Park Management Program PP-20/50 Order Code: PP-20 to PP-24 The MODPARK car park management program PP20/50 is a simple and attractive program that caters for the special needs of car park management and of access control management. The program uses a standard MS-Windows operator's interface. The car park operator works with images rather than with menus for the most basic functions like occupation control, alarm monitoring and direct unit control. More sensitive functions are protected by password. Central management functions and central cashier functions can be active in the same computer. The program works on all PC-AT compatible PC from a PC AT-486 up to the most powerful chip configurations. It uses standard MS-Windows NT or Windows 2000 and a standard SQL database. The system can be networked and allows for remote access via telephone lines according to the procedures defined by Microsoft. Several PP20 programs can operate in one network to share the task of managing larger installations. The database is documented and can be accessed by any other software using an ODBC driver. The package is designed to work with all languages that are implemented by Microsoft. All print out and screens are loaded from a separate text file at the start of the system. Thus any language even Chinese and Arabic can locally be implemented by translating the text with a text editor. C:\Daten\Documentpers\Tech_Be\Aktuell\PP-50-E-LogoV2.DOC Page 1/6

The PP20/50 allows performing a wide range of control and management functions: - Count and control the occupation of the different zones of a car park. - Monitor extraordinary movements and alarms from the ticket units - Monitor the On-Line status of all devices - Control the ticket units directly from the central - Supervise the cashier functions permanently - Register all movements for later statistical evaluation - Manage the long-term parker data base (20.000 standard) - Statistical analysis of the movements defined by the client himself - Password protection - Switchover to manual cashier program PP20/50 screens and messages and printouts can be translated and modified by the customer into any known language as long as a MS-Windows version in this language exists. Differences between PP20 and PP50 PP20 is a single user program with all the functions of the PP50. The PP50 is a 32 Bit program and is based on a multi tasking concept to work in a networked environment. It operates on Windows NT and Windows 2000. The different functions of the package can run on different computers in the network. See the following overview of the PP50 soft - and hardware concept. C:\Daten\Documentpers\Tech_Be\Aktuell\PP-50-E-LogoV2.DOC Page 2/6

PP50 Program Tasks Program Tasks Tasks can reside all in one PC or on any customer computer in the network Hardware Implementation Sample Accounting Remote Workstation Password Administration Server Device Configuration Traffic Counting Traffic Sign Control Network Link Software or dedicated Ethernet or Customers Network Control Station or Work Station Operator Interface Direct control Message Handling MS Access Database Control Station or Work Station Remote Control Station Communication tasks: Ticket Units Traffic counters RS485 Bridge RS485 RS485 Channels data to 4 network stations Receives data from all network stations To field devices up to 31 devices per line C:\Daten\Documentpers\Tech_Be\Aktuell\PP-50-E-LogoV2.DOC Page 3/6

Limits of the system functions: 4 communication lines up 32 ticket units per line totalling a basic 128 devices Standard MS-Workgroups network access to databases (long term parker, historical data) for up to 3 additional users 1 Master PP20/50 in conjunction with unlimited numbers of slave PP20 Password control: unlimited number of users unlimited number of access combinations read / modify limitation Long term parker definitions with 13 fields for person identification 9 fields for associated card limits 16 functions to handle the data individual printout definition of fields encoding of cards with database values Tariff definitions: up to 16 tariffs with customer specific names each with 24 freely adjustable time segments (1 min - 24 hrs) each time segment with 3 prices day time tariff per day of the week or per parking day max. price per day of the week or per parking day max. price per week toll free parking time grace period after payment minimum charge supplement for first time segment change at tariff limits: use higher tariff, lower tariff, cut off, continue present tariff until end of time segment fixed discount for validated ticket Holidays: 16 holidays can be defined in advance Time Zones: 16 time zones with customer specific names each time zone having: 7 days of the week plus holiday two valid time groups per day Access Levels: 16 levels with customer specific names Device Data Definition: 16 customer specific names device type parking price area entrance to parking exit from parking communication port of device address of device assign tariffs C:\Daten\Documentpers\Tech_Be\Aktuell\PP-50-E-LogoV2.DOC Page 4/6

Overview: devices access Levels parking price areas direct control of device Card Types: up to 15 card types possible with customer specific names Parking Areas: 16 areas with customer specific names used for price areas used for counting Account definitions: customer specific names of accounts 24 accounts of which 5 statistical accounts of turnover 10 free assignable accounts 9 accounts for special ticket sales 12 means of payment Accounts: Revenue: current total daily total monthly total per cashier daily/monthly/annual Discount ticket (option) current total daily total monthly total Device Messages: 255 messages names are user definable Parameters per message: Display Store Print Count Presence accounting Alarm 2 parameters showing field conditions of device Counting: 16 Parking zones by separate counting system or by ticket types parameters per type: Capacity Occupied spaces Free spaces Hysteresis Manual/Automatic control mode Full/Free condition Counting class (3) Time of day programmable capacity hourly movement statistic (option) hourly occupation statistic (option) hourly revenue statistic (option) C:\Daten\Documentpers\Tech_Be\Aktuell\PP-50-E-LogoV2.DOC Page 5/6

Language definition: any language stored in an ASCII file Direct device control select device barrier Open/Close communication On/Off In/Out of service Full/Free control anti passback On/Off free for card no. set time/date read device status anti passback Off for one passage for all cards transmit card data transmit time zones transmit tariffs Historical data searches: device message (255) year, month, day, hour card no. 4 functions list erase data list print all print marked records all data fields in any combination by using the build-in MS-ACCESS database Programmable statistics by the customer Minimum Hardware requirements: PC AT-586 500 MHz 96 MB RAM 4 MB hard disk 3.5" floppy disk 2 x RS 232 serial interface 2 x RS 485 serial interface (individual IRQ and base address) 1 x parallel printer interface (+1 if manual cashier) 15" colour monitor standard keyboard journal printer 80 columns MS-Windows NT or MS-Windows 2000 Ordering instructions: PP 20/50 PP 21/51 PP 22/52 PP 23/53 PP 24/54 DOC-PP20 for up to 4 ticket units on the bus for up to 8 ticket units on the bus for up to 15 ticket units on the bus for up to 31 ticket units on the bus for more than 31 ticket units on several busses user manual car park management C:\Daten\Documentpers\Tech_Be\Aktuell\PP-50-E-LogoV2.DOC Page 6/6