Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software



Similar documents
Loviisa 3 unique possibility for large scale CHP generation and CO 2 reductions. Nici Bergroth, Fortum Oyj FORS-seminar

Preliminary validation of the APROS 3-D core model of the new Loviisa NPP training simulator

Nuclear Design Practices and the Case of Loviisa 3

Public SUMMARY OF EU STRESS TEST FOR LOVIISA NUCLEAR POWER PLANT

CO MPa (abs) 20 C

CFD simulation of fibre material transport in a PWR core under loss of coolant conditions

NEW NUCLEAR POWER PLANT UNIT IN FINLAND ACCEPTED BY THE FINNISH PARLIAMENT

Hydraulic Pipeline Application Modules PSI s Tools to Support Pipeline Operation

CO 2 transport i rør Flow assurance

BAFFLES AS A MEANS OF STATION PROTECTION FROM HIGH AIR VELOCITIES - COMPARISON OF ANALYTICAL AND FIELD MEASUREMENTS RESULTS

Nuclear power plant systems, structures and components and their safety classification. 1 General 3. 2 Safety classes 3. 3 Classification criteria 3

The commissioning of the LHC: first the technical systems, then the commissioning with beam

DE-TOP User s Manual. Version 2.0 Beta

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

Andrea Basti* Italian National Institute of Nuclear Physics (INFN) Gran Sasso National Laboratory (LNGS) *Research Grant Holder

District Heating Network Monitoring, Control and Optimization with CyberVille IoE Application Platform

INTERNATIONAL. Technical journal for piping system integrity and efficiency

THERMAL ANALYSIS OF A DATA CENTRE COOLING SYSTEM UNDER FAULT CONDITIONS

Water hammering in fire fighting installation

Accidents of loss of flow for the ETTR-2 reactor: deterministic analysis

FIRE RISK ASSESSMENT IN GERMANY - PROCEDURE, DATA, RESULTS -

Testing and Utilization of Loviisa Full Scope Apros Model in Engineering and Development Simulator

Thermal Modeling Issues Concerning the Mechanically Pumped Two-Phase CO 2 Cooling for the AMS-2 2 Tracker

7.1 General Events resulting in pressure increase 5

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

Forces on Large Steam Turbine Blades

Leak detection in virtual DMA combining machine learning network monitoring and model based analysis

Steam System Best Practices Condensate System Piping

Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m

Solar Hot Water Heaters

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

LEAK DETECTION IN UNDERGROUND PIPELINES OF MUNICIPAL WATER DISTRIBUTION

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

Calculating Heat Loss by Mark Crombie, Chromalox

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

Safety issues of hydrogen in vehicles Frano Barbir Energy Partners 1501 Northpoint Pkwy, #102 West Palm Beach, FL 33407, U.S.A.

ENERGY SAVING WORT BOILING SISTEM IN BREWING FACTORY

Hybrid system. Energy-efficient and environmentally friendly

COMPRESSION. Bureau of Forestry. Natural Gas Advisory Committee January 15, Presentation to the.

INITIAL ASSESSMENT OF THE IMPACT OF JET FLAME HAZARD FROM HYDROGEN CARS IN ROAD TUNNELS AND THE IMPLICATION ON HYDROGEN CAR DESIGN

SAMPLE CHAPTERS UNESCO EOLSS

C. starting positive displacement pumps with the discharge valve closed.

DESIGN CHALLENGES AND OPERATIONAL EXPERIENCE OF A MEGA MED SEAWATER DESALINATION PLANT IN TIANJIN

System Assessment Capabilities for Fossil Fuel Power Stations

Link-Up. Solid Fuel Association Guide to Central Heating.

Recommended Practice for Software Acquisition

Swiss media visit to Olkiluoto August 15, 2014

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

The Central Solar Heating Plant with Aquifer Thermal Energy Store in Rostock - Results after four years of operation

Guidelines for FEASIBILITY STUDY

Turbulence Modeling in CFD Simulation of Intake Manifold for a 4 Cylinder Engine

District heating and cooling in Stockholm Site visit to the Ropsten plant

Water Management in Helsinki. Water supply. Mikael Sillfors

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

NUCLEAR POWER OVERALL GOOD FOR THE SOCIETY Finnish German Energy Day, 7th November 2012

Pressurized Water Reactor B&W Technology Crosstraining Course Manual. Chapter 9.0. Integrated Control System

COOKING THE ROOF CFD BEYOND THE WHITE SPACE

Qualification of In-service Inspections of NPP Primary Circuit Components

Application Note. ipix A Gamma imager to support various applications

ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS

CFD Beyond the Whitespace. Datacentres Central & Eastern Europe

Piping Systems for Nuclear Power Industry. Prague, October 2011

Efficient distribution of district heating and cooling. LOGSTOR pre-insulated pipe technology

The soot and scale problems

Dynamic Process Modeling. Process Dynamics and Control

FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES

APPLICATION OF TRANSIENT WELLBORE SIMULATOR TO EVALUATE DELIVERABILITY CURVE ON HYPOTHETICAL WELL-X

Exergy Analysis of a Water Heat Storage Tank

Wind Turbine Power Calculations

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

TECHNICAL INFORMATION ABOUT NATURAL GAS TRANSPORT

FULL ELECTRICAL LNG PLANTS: HIGHEST AVAILABILITY AND ENERGY EFFICIENCY THROUGH OVERALL SYSTEM DESIGN

This will also provide you with the knowledge to insure long life for your Investment

FEDERAL GOVERNMENT OVERSIGHT OF PIPELINE SAFETY

Teollisuuden Voima Oyj - General Presentation January Ilkka Mikkola Senior Adviser (Former Fuel Manager) Teollisuuden Voima Oyj

Stress and deformation of offshore piles under structural and wave loading

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Transportation of Hydrogen by Pipeline - Kunihiro Takahashi TRANSPORTATION OF HYDROGEN BY PIPELINE

MODELING THE PERFORMANCE OF FIRE PROTECTION SYSTEMS IN MODERN DATA CENTERS

HEAT PUMP FOR DISTRICT COOLING AND HEATING AT OSLO AIRPORT, GARDERMOEN

Session 2: Hot Water Supply

COMPARISON OF ELECTRICITY GENERATION COSTS

5.2. Vaporizers - Types and Usage

Real-time Monitoring Platform to Improve the Drinking Water Network Efficiency

Investigating Flexible Generating Capabilities at The Geysers. Geysers Power Company, LLC December 03, 2015

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

SOLVING REACTOR WATER CLEAN-UP SYSTEM ANOMALIES USING RELAP5 MOD3.3

Users Guide. By Dr. Don J. Wood Dr. Srinivasa Lingireddy. Featuring the Surge Wizard

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS

Numerical Simulation of Thermal Stratification in Cold Legs by Using OpenFOAM

Ultrasonic Technique and Device for Residual Stress Measurement

TVO and Nuclear Waste Management at Olkiluoto. Corporate Adviser

Tank Heating Solutions. For Oil Spill Response Vessels

Origin s. We ll manage the bulk of your hot water

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

Transcription:

th International Conference on Structural Mechanics in Reactor Technology (SMiRT ) Espoo, Finland, August 9-4, 9 SMiRT -Division 3, Paper 56 Investigations of a Long-Distance MW Heat Transport System with APROS Simulation Software Matti Paananen, Tommi Henttonen Fortum Nuclear Services Ltd., P.O. Box, 48 Fortum, Finland Matti.Paananen@fortum.com, Tommi.Henttonen@fortum.com Keywords: district heat, nuclear CHP, APROS ABSTRACT This paper presents a computer model and simulation results for a long-distance heat transport system. The modelled system is designed to transport MW of heat over a distance of 77 km for district heating purposes. This kind of a nuclear combined heat and power (CHP) option is being investigated as one option within Fortum s Loviisa 3 NPP project. The heat produced in Loviisa NPP would be utilized for the district heating of Helsinki metropolitan area in Finland. The objective of this study is to carry out simulations to examine the behaviour of such a large-scale heat transport system and to perform safety analyses for the purposes of preliminary planning of a heat transport system between Loviisa and Helsinki. The model was created using APROS (Advanced Process Simulation Environment) simulation software. Several transients including pump trips and leaks from the circuit into the surrounding service tunnel are simulated and their effects in the pipeline are investigated. The safety risks of the transients are analyzed. Major leaks cause the pressure in the circuit to fall drastically. The tripping of pumps can also cause challenging pressure transients. However, the consequences of the transients can be substantially limited with proper safety systems. INTRODUCTION Nuclear energy has been used for district heating in several countries both in dedicated nuclear heating plants and in combined heat and power (CHP) plants. Energy Company Fortum is applying to build a new nuclear power plant (NPP) in Loviisa, Finland. It has been suggested that this new NPP could be a CHP plant. The heat produced in Loviisa NPP could be utilized for the district heating of Helsinki metropolitan area (Fortum, 9). This would require transporting of heat over a distance of approximately 77 km. The longest existing delivery distance for nuclear district heating is 4 km in Slovakia (IAEA, 998). This kind of a long-distance heat transport system transporting heat over 77 km is studied in this paper. The transported heat power considered is MW. Modelling is an important tool in designing such a system. Modelling and simulations are especially useful when the behaviour of such a large-scale system under transients is examined. Tripping of pumps or leaks from the circuit into the surrounding tunnel can cause safety risks which can be examined with an extensive model of the system. This paper presents a computer model for a long-distance MW heat transport system and simulation results for different transients. Safety of the heat transport system is also discussed and ways to improve it are presented. 3 MODEL Heat transport system was modelled with APROS (Advanced Process Simulation Environment) simulation software. The model includes pipeline, pumps, valves, heat accumulator, tunnel and some automation. The principle of the modelled circuit is seen in Figure. One dimensional 6-equation model is used for the water and steam in the circuit.

Figure. A greatly simplified representation of the modelled heat transport circuit. There are two 77 km long pipelines and 7 pumps arranged in 4 pump stations in the model. Pipeline is modelled to both directions in the circuit (i.e. hot and cold leg). Pressure losses and heat losses in the pipeline are modelled. The pipeline is modelled as a steel pipe with a diameter of. m and a polyurethane insulation layer with a thickness of mm. Pipeline is divided into calculation nodes and the length of the nodes is limited to a maximum of m. An elevation profile for the pipeline is modelled. The pipeline is thought of as being in an underground tunnel and the elevation profile of the tunnel determines the profile of the pipeline. The profile is taken from a realistic elevation profile scenario for the tunnel. Elevation difference between the lowest-lying and highest-lying points in the pipeline is almost 9 m. Four pump stations are modelled in the pipeline as can be seen in Figure. Three of these pump stations include a pump in both hot and cold leg and one pump station has only one pump in the NPP end of the circuit. All the pumps are identical and operated at the same rotation speed. This gives a symmetric pressure head in the pipeline. Pressure balancing lines between the hot and cold leg are modelled. These lines are located on both sides of the points where hot and cold lines have equal pressure as shown in Figure. In total there are six pressure balancing lines. There is a check valves in each of the lines. These pressure balancing check valves are positioned so that under normal operation they do not let flow through. Under transients they can let flow through and level down pressure changes if pressure in either of the legs increases or decreases significantly. Cold Hot Pressure 35 37 39 4 43 45 47 49 5 53 Figure. Pressure balancing lines. Red and blue lines represent the pressure in the hot and cold legs respectively. Pressure balancing lines are located on both sides of the point where the hot and cold legs have equal pressure. Check valves in the pressure balancing lines do not let flow through under normal operation conditions.

There are also sectioning valves modelled in the pipeline every km. These valves can be used to separate the circuit in km sections in the case of a leak. A heat accumulator is modelled in the city end of the circuit. The accumulator is atmospheric and connected directly to the transport pipeline. The district heating circuit of the city is separated from the accumulator by heat exchangers. The purpose of the accumulator is to store heat and to keep a constant pressure in the circuit. The liquid volume of the accumulator was modelled to be 5 m 3. The calculation model includes also a part of the underground tunnel so that the total behaviour of the system can be simulated. The modelled tunnel is a km section of the 77 km tunnel. This section is thought of as being separated from the rest of the tunnel by fire doors. The modelled tunnel is divided into m nodes which are connected by water and gas branches. Ventilation shafts connected to the environment are modelled in both ends of the tunnel. The cross-sectional area of the tunnel is 3 m. 4 SIMULATIONS Simulated properties of the heat transport system in steady state are shown in Table. Also different temperatures and flows were simulated but those values shown in Table were used as initial state for all the simulations presented in this paper. The pressure profile in the circuit in steady state is shown in Figure 3 and Figure 4. The effect of hydrostatic pressure is removed from the pressure profile in Figure 4 (i.e. the pressure is normalized to sea level). There are also a 5 bar limit pressure curve and boiling limit curves for C and 5 C water in Figure 4. Table. Basic information of the modelled circuit in steady state. Mass flow 358 kg/s Volume flow: cold leg 3.63 m 3 /s hot leg 3.79 m 3 /s Flow velocity: cold leg 3. m/s hot leg 3.35 m/s Inner diameter of the pipes mm Hot water temperature C Cold water temperature 54 C Transferred heat power MW Power of circulation pumps: cold leg 5.8 MW/pump hot leg 5.5 MW/pump total power 39.7 MW Heat losses from the pipes MW 3

,6,4,,8 Pressure [MPa],6,4,,8,6,4, 3 4 5 6 7 8 s, cold s, hot Boiling limit C Boiling limit 5 C Figure 3. Simulated absolute pressure profile in the circuit in steady state. Pressure profile is determined by pipeline elevation profile, pressure losses and pressure increase by pumps. Pressure normalised to sea level [MPa],6,4,,8,6,4,,8,6,4, -, -,4 -,6 -,8 Helsinki (city) Pump Pump Pump 3 Pump 4 3 4 5 6 7 8 Hot Cold Loviisa (NPP) 5 bar limit Boiling limit C Boiling limit 5 C s Figure 4. Simulated pressure profile in steady state. Hydrostatic pressure is removed from the profile. There are also pump stations locations and pressure limits shown in the picture. Pump trips and leaks are possible safety risks in this kind of a circuit. Therefore we studied various cases of both pump trips and leaks. They included tripping of a single pump, tripping of a pump pair and 4

tripping of all the pumps simultaneously. The emphasis was on investigating the behavior of pressure balancing check valves during transient conditions. The simulations included different sizes of leaks from the pipeline into the tunnel. The sectioning of the pipeline in order to isolate the leak point from the rest of the circuit was simulated. Pump trips can cause high pressure in the circuit that can damage the system. They can also cause pressures so low that vigorous boiling occurs inside the pipeline. Leaks from the pipeline into the tunnel cause the pressure to drop in the pipeline. Obviously conditions in the tunnel can get very severe when over C water leaks into atmospheric pressure. Time step of the simulation was set short enough in order to simulate pressure wave propagation in the circuit with good precision. ms time step was used for the simulations shown in this paper. 5 RESULTS 5. Pump trips Tripping of a single pump causes a pressure wave to propagate in the pipeline. Simulated behaviour during the first s after a pump trip can be seen in Figure 5. It is obvious of Figure 5 that tripping of one pump can cause very high pressure in the circuit if mitigating measures are not appropriately designed. It can also cause the pressure to drop down to boiling limit in the hot or the cold pipeline. Pressure balancing check valves were not included in simulation in Figure 5. However, even if the pressure balancing check valves are in operation, tripping of a single pump can cause similar risks. Pressure profile s after a single pump trip with pressure balancing check valves can be seen in Figure 6. Absolute pressure as high as 3 bars is reached. The pumps in the model are arranged as pairs. Tripping of a pump pair can have worse consequences than tripping of a single pump. However, the consequences depend strongly on whether there are pressure balancing check valves in the circuit or not. Pressure profile s after pump pair trip without pressure balancing check valves is shown in Figure 7 and with pressure balancing check valves in Figure 8. The importance of pressure balancing check valves for the safety of the system is obvious from these pictures. The valves let flow through and level out the big pressure difference between the hot and the cold pipeline. Actually, the tripping of a pump pair is a considerably safer transient than tripping of a single pump as long as there are pressure balancing lines between the pipelines. Since the consequences of a single pump trip are worse than a pump pair trip, the tripping of only one pump should be prevented. Pump system should be designed so that a pair of pumps always operates at a common rotation speed. If despite of this a single pump would trip, the consequences of a single pump trip could be avoided by stopping the other pump of the pump pair soon after the trip. Simulations showed that the results were similar to a pump pair trip when the other pump of a pump pair was stopped for example 5 s after the tripping of one pump. Operating of the heat transport system with one pump pair out of operation and pressure balancing lines open is not reasonable because of mixing of hot and cold water. Closing of pressure balancing lines increases pressure difference between the hot and cold pipeline. Therefore, if the pressure balancing valves are closed after a pump pair has tripped, the rotation speed of the pumps that are still in operation should be decreased. In this way the system can be operated safely with reduced power when one pump station is out of operation. Simultaneous tripping of all the pumps does not cause any high or low pressure peaks. The system stabilizes in a couple of minutes and no direct safety risk is caused for the heat transport circuit. Tripping of all the pumps stops the heat transport in the circuit immediately. In that case the hot water reservoir of accumulator can still be used for district heating. If the pumps are operating normally but heat transfer from the NPP stops, there is additional 87 m 3 hot water reservoir in the pipeline. 5

Pressure normalised to sea level [MPa],6,4,,8,6,4,,8,6,4, -, -,4 -,6 -,8 3 4 5 6 7 8 t=... s s, hot 4 s, hot 6 s, hot 8 s, hot s, hot s, cold 4 s, cold 6 s, cold 8 s, cold s, cold 5 bar limit Boiling limit C Boiling limit 5 C s Figure 5. Pressure profile development during the first s after tripping of a single pump in the hot leg of the circuit. The tripped pump is the second pump from the city end of the circuit. Pressure profile is plotted with intervals of s. Pressure balancing lines are not in operation in this simulation. Pressure in some parts of the hot leg increases to about 7 bars in approximately 9 s. Pressure normalised to sea level [MPa],8,6,4,,8,6,4,,8,6,4, -, -,4 -,6 3 4 5 6 7 8 6 s, hot s, cold 5 bar limit Boiling limit C Boiling limit 5 C Figure 6. Pressure profile s after tripping of a single pump in the hot leg of the circuit. The tripped pump is the first pump from the city end of the circuit. Pressure balancing lines are in operation in this simulation. Absolute pressure reaches value as high as 3 bars. s

Pressure normalised to sea level [MPa],6,4,,8,6,4,,8,6,4, -, -,4 -,6 -,8 3 4 5 6 7 8 s, hot s, cold 5 bar limit Boiling limit C Boiling limit 5 C s Figure 7. Pressure profile s after tripping of the first pump pair from the city end of the circuit. Pressure balancing lines are not in operation in this simulation. Absolute pressure increases above 3 bars in the hot leg and decreases down to the boiling limit in the cold leg. Pressure normalised to sea level [MPa],6,4,,8,6,4,,8,6,4, -, -,4 -,6 -,8 3 4 5 6 7 8 7 s, hot s, cold 5 bar limit Boiling limit C Boiling limit 5 C Figure 8. Pressure profile s after tripping of the first pump pair from the city end of the circuit. Pressure balancing lines are in operation in this simulation. Pressure balancing check valves let flow through levelling down the pressure difference between the hot and the cold leg significantly. Pressure behaviour is much safer than without pressure balancing lines (see Figure 7). s

5. Leaks Leaks from the pipeline into the modelled km section of tunnel were simulated and the consequences in both the pipeline and tunnel were investigated. Pressure behaviour in the pipeline with a leak of a size of % of the flow area of the pipe is shown in Figure 9. Pressure falls immediately in the leak point inside the pipeline which causes a pressure wave to propagate in the circuit. Eventually the pressure in the whole circuit has dropped and remains below the original value. The effects of leaks of size % or % of the flow area of the pipeline are much stronger than those of a % leak. In these bigger leaks the pressure inside the pipeline falls immediately down to the boiling limit. Pressure profile in the pipeline after a % leak is shown in Figure. The circulation pumps in the circuit were stopped s after the beginning of the leak in the simulation because the pressure drop is so drastic that it is not reasonable to keep the pumps in operation. The falling pressure causes vigorous boiling in the pipeline. This makes the pressure behaviour inside the pipeline complicated and rapidly varying. The leaks have also serious consequences inside the tunnel. The effects of leaks inside the tunnel were also investigated but those results are not presented in this paper. For the conditions inside the tunnel it is crucial whether the leaking water is above or below C. However, in the pipeline even water with temperature below C can boil if there is a leak. This is mainly due to the elevation profile of the pipeline. Pressure near the leak falls close to the atmospheric pressure but the pressure can fall considerably lower in other parts of the circuit. Limiting a leak by closing the sectioning valves in the model was also simulated. Sectioning valves were modelled in the circuit at intervals of about km. Simulations showed that all the sectioning valves in the circuit should be closed instead of only the valves next to the leak to ensure safe pressure behaviour in the circuit. Closing the valves does not stop the leak immediately there is about 6 m 3 of water in a km section of pipeline. The smaller the leak the longer the leak goes on even after the sectioning valves are closed. The leak mass flows for %, % and % leaks are shown in Figure for cases where sectioning valves with 6 s driving time are closed s after the beginning of a leak. Pressure normalised to sea level [MPa],6,4,,8,6,4,,8,6,4, -, -,4 -,6 -,8 3 4 5 6 7 8 s, hot 4 s, hot 6 s, hot s, hot s, cold 4 s, cold 6 s, cold s, cold 5 bar limit Boiling limit C Boiling limit 5 C s Leak Figure 9. Pressure profile development during the first 6 s and pressure profile s after the beginning of a leak of size % of the flow area of the pipeline. Pressure falls in the leak point immediately and after s the pressure in the whole circuit has settled down to a lower level. 8

Pressure normalised to sea level [MPa],6,4,,8,6,4,,8,6,4, -, -,4 -,6 -,8 3 4 5 6 7 8 s, hot s, hot s, cold s, cold 5 bar limit Boiling limit C Boiling limit 5 C s Leak Figure. Pressure profile s and s after the beginning of a leak of size % of the flow area of the pipeline. Pressure falls in the vicinity of the leak point immediately down to boiling limit. mass flow [kg/s] 4 8 6 4 % leak flow % leak flow % leak flow 3 4 5 6 7 8 9 time [s] Figure. %, % and % leak mass flows the circuit into the tunnel. The closing of sectioning valves begins s after the beginning of leak. It takes 6 s to fully close the valves. 9

6 CONCLUSION A computer model was developed and various transient simulations run and analyzed for a long-distance MW heat transport system. The aim of these investigations was to study the technical feasibility and safety of such a large-scale system for the purposes of preliminary planning. Both pump trips and leaks can cause challenging transients in the system. There are, however, ways to prevent or limit the consequences with proper safety systems. Pressure balancing check valves between the hot and cold leg level out pressure differences between the pipelines under transients. Single pump trips should be prevented so that two pumps are always tripped instead of one. Leaks can be limited by sectioning valves and the valves should be closed in all the circuit to ensure safe pressure behaviour. The developed model can be expanded to study a more detailed system. It can also be attached to an APROS NPP model to study the behaviour of a whole CHP plant. REFERENCES Fortum Power and Heat Oy. 9. Application for a Decision-in-Principle Concerning the Construction of a Nuclear Power Plant Unit Loviisa 3 IAEA. 998. Nuclear heat applications: Design aspects and operating experience. IAEA-TECDOC-56