Piezoceramic Sensors and Infrasound Technology



Similar documents
9000 Series Accelerometers Specifications

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: TREX COMPANY, LLC. Series/Model: Trex Seclusion

Fiber Optic High Density ACC Sensor System Faser Optisches Beschleunigungs-Messsystem

HDO700 P FIBRE OPTIC TRANSMITTER

SC-30 INTEGRATING SOUND LEVEL METER REAL TIME FREQUENCY ANALYZER

D A T A S H E E T. KRK VXT8 - Design Features V X T S E R I E S - P R O F E S S I O N A L A C T I V E S T U D I O M O N I T O R S

Remarkable achievements

Generic - Hearing Loop - (AFILS) U.S. System Specification

RF Communication System. EE 172 Systems Group Presentation

Direct and Reflected: Understanding the Truth with Y-S 3

2. The Vector Network Analyzer

How To Use A Sound Card With A Subsonic Sound Card

MICROPHONE SPECIFICATIONS EXPLAINED

Sound Attenuation INTRODUCTION

11: AUDIO AMPLIFIER I. INTRODUCTION

Acoustic Terms, Definitions and General Information

How Noise is Generated by Wind Turbines The mechanisms of noise generation. Malcolm Hayes Hayes McKenzie Partnership Ltd Machynlleth & Salisbury

2002 IS Catalog. Page

Interference to Hearing Aids by Digital Mobile Telephones Operating in the 1800 MHz Band.

Noise Control Solutions For Standby Power Generators

Infrasound BY ELISABETH BLANC AND LARS CERANNA

Detecting & Locating Leaks in Water Distribution Polyethylene Pipes

Application Note AN1

Testing Panasonic s WM-61A Mike Cartridge

The Role of Acoustics in Curtain Wall Design:

ACOUSTIC PERFORMANCES OF AN HEMIANECHOIC ROOM FOR ELECTROMAGNETIC COMPATIBILITY TESTS

Atmospheric Effects On Traffic Noise Propagation Behind Noise Barriers

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Application Note Noise Frequently Asked Questions

75 Ω Transmission System

VAT CALCULATED AT 23% (AS FROM 1/1/12)

SECTION 13. Multipliers. Outline of Multiplier Design Process:

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: TUBELITE, INC. SERIES/MODEL: T TYPE: Two-Lite Storefront

TDA W Hi-Fi AUDIO POWER AMPLIFIER

3.0 Exhaust Muffler Design Principles. 3.1 Basic Concepts

Schindler 3300 / Schindler 5300 Information on noise and vibration.

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

SEISMIC MONITORING & PROTECTION SYSTEMS

Airborne Sound Insulation

How To Reduce Noise From A Test Screen

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

A Novel GPS Survey Antenna

Impedance 50 (75 connectors via adapters)

Use Data Budgets to Manage Large Acoustic Datasets

Vibration Isolation in Data Centers

Infrasound events detected with the Southern California Seismic Network

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

DS 600. A contact free flux gate based current measurement sensor 600A rms

Some Measurements on DVB-T Dongles with E4000 and R820T Tuners:

DVT913 TV CHANNEL CONVERTER

The Effects of Ultrasonic Sound Generated by Ultrasonic Cleaning Systems on Human Hearing and Physiology

Combustion Dynamics Instrumentation

Antennas & Propagation. CS 6710 Spring 2010 Rajmohan Rajaraman

Product Overview 9100D

Current Probes. User Manual

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

MAINTENANCE & ADJUSTMENT

UNIVERSITY OF CALICUT

Basic Acoustics and Acoustic Filters

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Eliminator 15-inch two-way high-output stage system 350-watts continuous Ring-Mode Decoupling (RMD ) for improved sound quality and dynamic integrity

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

is the power reference: Specifically, power in db is represented by the following equation, where P0 P db = 10 log 10

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

The Universal DAQ Device. Connect and measure immediately!

BASS MANAGEMENT SYSTEM

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Linear Parameter Measurement (LPM)

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

Blast Vibration and Overpressure Monitor

How To Counter Noise Noise From A Low Voltage Differential Signaling Circuit

PSP3. Stereo M/S preamplifier. User manual

Application Note AN-00126

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

Exhaust noise control case study for 2800 class locomotive

The next generation of noise measurement instruments

The Calculation of G rms

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

IFI5481: RF Circuits, Theory and Design

Vibration and Shock tests on a typical Current Transformer Set

Noise from large wind turbines (with focus on low frequencies)

Asset Management Made Easier SonarBell Passive Acoustic Marker Speaker : John Pepper

Aircraft cabin noise synthesis for noise subjective analysis

Trace Gas Exchange Measurements with Standard Infrared Analyzers

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Measurement, analysis, and monitoring of RF signals

WIRELESS ASSET MONITORING

HIGH REPEATABILITY SPDT, BROADBAND 12 GHZ MAGNETIC-LATCHING RF RELAY

Telephone- and leased line modem for industrial applications TD-36

Getting Started with SmaartLive: Basic Measurement Setup and Procedures

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Minimum requirements for DVB-T receiving antennas for portable indoor and portable outdoor reception

iva Cable & Antenna Analyzer

APPLICATION NOTE AP050830

BOTDR Measurement Techniques and Brillouin Backscatter Characteristics of Corning Single-Mode Optical Fibers

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

Transcription:

Piezoceramic Sensors and Infrasound Technology Carrick L. Talmadge National Center for Physical Acoustics University of Mississippi, Oxford MS

Potential Applications of Infrasound Sensors monitoring potential atmospheric nuclear tests (CTBT applications) natural hazard detection of volcanos, tornados, tsunamis monitoring natural phenomena such as hurricanes and bolides Atmospheric science applications such as studying structure of stratosphere, probing physics of the lower thermosphere.

Challenges of Atmospheric Infrasound Noise associated with atmospheric turbulence ( wind noise ), especially at frequencies below 0.1 Hz. Conventionally this is solved by adding large wind-noise filters to sensors. The cost of the filters typically far exceeds the cost of the infrasound sensor itself. Environmental exposure is a hazard to current, rather delicate microphones, so vaults are constructed to stablize temperature and protect the instrument from environmental exposure.

Infrasound Pipe Array: State of the Art Wind Noise Sensor Microbarometer Vault 6.5 m 28.5 m 70 m ~2.6 m

Goals of This Instrument Development Replace large pipe arrays with array of infrasound sensors. Ruggedize sensors, and construct them to be insensitive to thermal fluctuates: Removes requirement for instrument vault. Make them low-cost enough ($750 vs $5000+) to make practicable multiple arrays of sensors. Low replacement cost also reduces risk associated with damaged or destroyed sensors.

Piezoceramic Sensors Resonant Frequency - 1.8 khz (hinged condition) Sensitivity - 3.4 mv/pa Temperature Compensation Reverse bimorphs Insulated enclosures, small openings Charge Generating Must operate into a high impendence

Frequency Response of Piezeoceramic Sensors higher frequencies strongly attenuated, phase becomes incoherent 3-dB cut-off for 35-mm element very flat amplitude/phase response below 500 Hz ideal for long-distance sensing Band start frequency depends on design of preamplifier. We can reliably measure pressure signals down to periods of 10 5 s.

Schematic of NCPA Sensors C50 pincompatible connector This 4-element design reduces effects of temperature gradients across sensors. Current design has different base plate, sensor lid. Still Chaparral 50 compatible.

Characteristics of Sensor highly ruggedized 0.0005 Hz- 100 Hz operating range (3-dB). Can be calibrated to 500-Hz. plug compatible with Chaparral 50 self-calibration using reciprocal calibration method has been demonstrated from 0.1 100 Hz, calibration chamber with calibrated volume source. Sensor can be configured as accelerometer (or dual pressure/acceleration sensor with same sensing elements).

Microphone Noise Floor

Comparison with C50 Microphone

Single Sensor Comparison with C50

Single Sensor Comparison

Comparison with Vaisala Pressure Sensor

High Frequency Sensor Allow use of microphone for low-frequency sound, long-range propagation experiments. 0.1 Hz- 1000 Hz operating range, configurable gain Improved vibrational isolation (elevated sensor applications). More compact sensor packaging. Vertical (4-m, 8-element) portable towers are in development at the NCPA.

Comparison of HF Sensor to B&K 4193

2009 Nevada Field Deployment of Array Nominal array locations were at 180 250 km, in 10 km steps

Array Geometry All infrasound microphones were NCPA sensors. Outer sensors characteristics: 10 mhz 100 Hz, 0.13 V/Pa; center mike 1 mhz 100 Hz, 0.025V/Pa Digitizers used were Geotech SMART 24 ( even numbered array ) or Miltech Fence Posts ( odd numbered arrays ).

Field-Deployed Microphone

Sources for Nevada Deployment July 14, 2009 4 ton TNT-eq explosion 4, 20 and 80 tons-tnt equivalent explosions at the Utah Testing and Training Range (UTTR), as part of the Trident missile disposal program.

Source Capture 23 km South Source capture used 2 co-located microphones 23-km south of source. Assuming spherical spreading, source strength was about 70-Pa at 1 kilometer. Source capture used a Chaparral USB Digitizer.

Source Spectral Content Scalloping probably associated with multiple arrivals associated with propagation effects.

Vertical Sound Speed Profile

Expected Signal Transmission

Atmospheric Absorption

Typical Arrival Structure

Typical Arrival Structure

Typical Arrival Structure

Typical Arrival Structure

Typical Arrival Structure

Typical Arrival Structure

Typical Arrival Structure

Typical Arrival Structure

Observed Power

Average Noise Floor f 7/3 f 1 fc = 20 Hz (wind noise filter)

Seismic Signals Miltech Fence posts had 3-axis geophones (Geospace GS-32CT). Arrivals were observed on these sensors coincident with the infrasound sensors.

Frequency Spectrum Peak energy was near 0.7 Hz High-frequency tail above 20-Hz was unexpected. However, it was observed at all sites with two different recording systems, and with two different technologies (infrasound mikes, seismometer)

Conclusions A new sensor technology incorporating piezoceramic sensors has been developed at the NCPA. This technology was successfully field tested in a large scale deployment in Utah/Nevada from July 13 September 22, 2009. Very few sensor related problems were encountered during experiment. Main surprise was observation of high-frequency signals which are probably associated with nonlinear propagation effects at stratospheric elevations.