When Procedural Support really matters Navien TM A+ Intracranial Support Catheter
Coils / Liquid Embolics DURABLE ovalization resistance, Maintains patent lumen in tortuosity for smooth micro catheter manipulation, Bringing support point distal provides stability for: TRACKABLE low tracking force, LARGE ID in 5F & 6F catheters, Ease of catheter manipulation and less micro catheter kick out, Allows easy device and micro catheter manipulation during:, Balloon-assisted coiling Stent-assisted coiling Pipeline TM embolization device Contrast runs Coiling 6 x 4 Multilobular Aneurysm with the Covidien owned image
Acute Ischemic Stroke LARGE ID in 5F & 6F catheters, Allows capture of large clot and greatest aspiration for Solitaire TM Device procedures, TRACKABLE low tracking force, Allows access close to thrombus for stable clot crossing, Solitaire TM Device delivery and local aspiration, DURABLE ovalization resistance, Ensures high aspiration even in tortuosity. Aspiration drops when catheters kink; the catheter has great kink resistance., Stroke Navien TM A+ 058 Intracranial Support Catheter in M for Stroke with the Solitaire TM Device Covidien owned image
Flow Diversion TRACKABLE low tracking force, Enhances distal access bringing support point closer to treatment site, increasing stability for device delivery and deployment, LARGE ID in 5F & 6F catheters, Allows for better roadmaps and placement of multiple catheters, DURABLE ovalization resistance, Ensures patent lumen in guide catheter allowing unrestricted movement of micro catheter, Flow Diversion Giant Recurrent ICA Aneurysm with the Navien TM A+ 07 Intracranial Support Catheter 07 catheter Covidien owned image
Navien TM A+ Intracranial Support Catheter brings superior benefits compared to the tested catheters,, Navien TM A+ intracranial support catheter - the large inner diameter is providing more clinical treatment options than the tested catheters,,.058 ID Stryker DAC * 057, ID 5MAX * catheter.054 ID 07 catheter.07 ID Neuron * 07 catheter.070 ID Stryker DAC * 070, ID Higher flow rate enables better contrast injections and visualization,, Higher aspiration rates,, 5F 6F Capture of larger pieces of clot,, More flexibility, allowing the use of different device combinations,,.07 0.75 0.46 Better trackability for an optimized treatment platform compared to the tested catheters,, 0.46 0.9 OPTIMAL Distal support that reaches further than the tested catheters,, 0.74 Navien Neuron * 05 catheter Stryker DAC * 0.57 catheter Navien 07 catheter Neuron * 070 catheter Stryker DAC * 0.70 catheter Support closer to the treatment site for more stability than the tested catheters during device delivery and deployment,, AVERAGE TRACKING FORCE: Final Cm NAVIEN CATHETER.058 NAVIEN CATHETER.07 Better durability for optimized performance than the tested catheters,,.5% Ovalization 9.6% Ovalization Great kink resistance maintains patent lumen for device delivery,, NEURON * CATHETER.05 NEURON * CATHETER.070 Great aspiration flow rate through unkinked catheter,, 0.8% Ovalization 8.80% Ovalization STRYKER DAC *.057 5F STRYKER DAC *.057 6F * When used as indicated with the Solitaire FR device 66.% Ovalization 9.97% Ovalization
Navien TM A+ Intracranial Support Catheter Device Details Polymer Adhesive Binding agent for layers Platinum Coil Marker Provides radiopacity of tip Polyester Jacket Provides proximal stability and distal flexibility Flat Wire Nitinol Coil Enables maintenance of lumen inner diameter PTFE Liner Smooth delivery of micro catheters and therapeutics Navien TM A+ Intracranial Support Catheter Ordering Information Product Catalogue Number RFXA058-05-08 RFXA058-5-08 RFXA058-5-08 RFXA058-0-08 RFXA07-95-08 RFXA07-95-08MP RFXA07-05-08 RFXA07-5-08 RFXA07-5-08 RFXA07-05-08MP RFXA07-5-08MP RFXA07-5-08MP RFXA07-0-08 RFXA07-0-08MP Outer Diameter (Fr/inch) 5./0.070 max 5./0.070 max 5./0.070 max 5./0.070 max Reference DWGRFX058-XXX-XX and DWGRFX07-XXX-XX INDICATIONS: The Solitaire revascularization device is designed for use in the flow restoration of patients with ischemic stroke due to large intracranial vessel occlusion. Patients who are ineligible for intravenous tissue plasminogen activator (IV t-pa) or who fail IV t-pa therapy are candidate for treatment. The Navien intracranial catheter is indicated for the introduction of interventional / diagnostic devices into the peripheral, coronary, and neuro vasculature. The Navien intracranial catheter is also indicated for the removal/ aspiration of fresh, soft emboli and thrombi from selected blood vessels in the arterial system, including neurovasculature. Inner Diameter (inch) Total Length (cm) 05 5 5 0 95 95 05 5 5 05 5 5 0 0 058, N= Envoy *, N= Chaperon *, N= DAC * 057, N= Neuron * 05, N= Flexor *, N= 5MAX *, N= Tip Shape Multi-Purpose 5 o Multi-Purpose 5 o Multi-Purpose 5 o Multi-Purpose 5 o Multi-Purpose 5 o Usable Balloon Wire Compatibility Crossing Length O.D. (mm) (inch) (Fr) Distal Flexible Lenght for all sizes = 8cm. 07, N= Envoy *, N= FargoMax *, N= DAC * 070, N= Chaperon *, N= 4MAX *, N= Flexor *, N= Indications, contraindications, warnings and instructions for use can be found in the product labeling supplied with each device. COVIDIEN, COVIDIEN with logo, Covidien logo and positive results for life are U.S. and internationally registered trademarks of Covidien AG. TM * Trademark of its respective owner. Other brands are trademarks of a Covidien company. 04 Covidien. 7698-00 (B) MAR/4 Covidien 06-08 Rue la Boétie 75008 Paris France + 56 88 59 0 [T] + 56 88 59 [F] www.coviden.com