Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W



Similar documents
PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

Emergency lighting units EM powerled

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

LED light engine / OLED LED linear /area. Umodule STARK LLE CLASSIC STARK LLE. Ordering data

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

LED light engine / OLED LED flexible. Umodule LLE-FLEX umodule LLE FLEX ADVANCED

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC

Nominal Power [W] Radiance Angle [ ] Color Temp. [K]

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE

LED control gear. LED control gear

STRATO LED Drivers 70W, Single output

Digital gear for fluorescent lamps

Product and functional description

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Safety technique. Emergency stop module BO 5988 safemaster

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Radiance Angle [ ] Nominal Power [W] Color Temp. [K]

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

EGSTON Standard E2xFxWx 12W

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Operating Manual UWAPS-TINY Series

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

User s Manual Before using the inverter, you need to read and save the safety instructions.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

connecdim Gateway G1 Ethernet TCP/IP to DALI

Radiance Angle [ ] Color Temp. [K]

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

LINEAR SYSTEM 3000K 4000K 5000K 6000K 7000K

How To Build A Low Voltage Capacitor Lvcp

Actuator-Sensor-Interface

DS 600. A contact free flux gate based current measurement sensor 600A rms

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

The most sustainable lighting solution. QL 85W Induction Lighting System

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

I STAR COMPUTER CO., LTD

Panel Meters and Controllers Modular Panel Meter Type EDM 35

ST Series POWER SUPPLIES USER INSTRUCTIONS

38 Series - Relay interface modules A

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Rated Lumen [lm] Nominal. Volts [V] [lm]

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

COOL Shelf Quick Connect

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Three-phase monitoring relay CM-PFE

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

650W Single Output Power Supply

Digital input modules

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Application Note TMA Series

BB800 Off-Grid Solar System

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

TEP 200WIR Series, Watt

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

TIG INVERTER INSTRUCTION MANUAL

IVIOS LED III. LUM Technical Information

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

PWM-60 series IP67 TRC ELECTRONICS, INC

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Type: DILM9 10(24VDC) Article No.:

Datasheet. Arrant-Light Oy. 120W DR Series

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

basicdim DGC Compact control module

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Energy Management Energy Meter Type EM23 DIN

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supplies 3. SDN-P DIN Rail Series

SolarMax P series The power package for residential solar plants

How To Make A Fronius Cl Power Inverter

HERZ-Thermal Actuators

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

38 Series - Relay interface modules A

Transcription:

T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a failure rate max. 0.2 % per 1,000 h) Large temperature range (for values see table) Automatic start after replacement of defective lamps Safety shutdown of defective lamps and at end of life Temperature protection as per EN 61347-2-3 C5e Technical data AC voltage range DC voltage range Overvoltage protection Defined warm start Operating frequency Type of protection 198 264 V 176 264 V ( start 198 V DC) 270 V AC, 360 h 2 s 40 khz IP20 (except PCB versions) È Standards, page 3 matrix, page 3 Wiring diagrams and installation examples, page 5 Ordering data Type Article number Packaging carton Packaging pallet Weight For luminaires with 1 lamp PC 1x4-13 W BASIC 24138831 25 pieces 1,100 pieces 0.042 kg PC 1x5-16 W BASIC 24138830 25 pieces 1,100 pieces 0.042 kg PC 1x5-16 W BASIC PCB Printed circuit board without case 24138836 25 pieces 1,100 pieces 0.028 kg PC 1x BASIC 24138829 25 pieces 1,100 pieces 0.042 kg PC 1x BASIC PCB Printed circuit board without case 24138835 25 pieces 1,100 pieces 0.028 kg PC 1x26 W BASIC 22176208 25 pieces 1,100 pieces 0.042 kg www.tridonic.com 1

Specific technical data wattage type Type For luminaires with 1 lamp Article number Dimensions L x W x H Hole spacing D power Circuit power EEI Current at 50 Hz λ at 50 Hz tc point 220 V 240 V 220 V 240 V max. 2 Ambient temperature ta 2 1 x 4 W T5 PC 1x4-13 W BASIC 24138831 80.0 x 40.0 x 21 mm 70 mm 3.5 W 5.0 W A2 0.045 A 0.043 A 0.51 0.48 80 C -25... 50 C 1 x 6 W T5 PC 1x4-13 W BASIC 24138831 80.0 x 40.0 x 21 mm 70 mm 5.0 W 7.0 W A2 0.059 A 0.057 A 0.54 0.51 80 C -25... 50 C 1 x 8 W T5 PC 1x4-13 W BASIC 24138831 80.0 x 40.0 x 21 mm 70 mm 6.5 W 8.5 W A2 0.067 A 0.063 A 0.58 0.56 80 C -25... 50 C 1 x 13 W T5 PC 1x4-13 W BASIC 24138831 80.0 x 40.0 x 21 mm 70 mm 11.0 W 15.5 W A3 0.114 A 0.106 A 0.62 0.61 80 C -25... 50 C 1 x 10 W TC-DD PC 1x4-13 W BASIC 24138831 80.0 x 40.0 x 21 mm 70 mm 9.0 W 11.5 W A3 0.087 A 0.081 A 0.60 0.59 80 C -25... 50 C 1 x 16 W TC-DD PC 1x5-16 W BASIC 24138830 80.0 x 40.0 x 21 mm 70 mm 14.0 W 18.0 W A3 0.130 A 0.121 A 0.63 0.62 85 C -25... 50 C 1 x 10 W TC-DEL PC 1x5-16 W BASIC 24138830 80.0 x 40.0 x 21 mm 70 mm 8.5 W 11.5 W A3 0.089 A 0.084 A 0.59 0.57 85 C -25... 50 C 1 x 13 W TC-DEL PC 1x5-16 W BASIC 24138830 80.0 x 40.0 x 21 mm 70 mm 12.0 W 15.5 W A3 0.112 A 0.106 A 0.63 0.61 85 C -25... 50 C 1 x 5 W TC-SEL PC 1x5-16 W BASIC 24138830 80.0 x 40.0 x 21 mm 70 mm 4.5 W 6.5 W A2 0.055 A 0.051 A 0.54 0.53 85 C -25... 50 C 1 x 7 W TC-SEL PC 1x5-16 W BASIC 24138830 80.0 x 40.0 x 21 mm 70 mm 6.0 W 8.0 W A2 0.065 A 0.063 A 0.56 0.53 85 C -25... 50 C 1 x 9 W TC-SEL PC 1x5-16 W BASIC 24138830 80.0 x 40.0 x 21 mm 70 mm 7.5 W 10.0 W A2 0.078 A 0.073 A 0.58 0.57 85 C -25... 50 C 1 x 11 W TC-SEL PC 1x5-16 W BASIC 24138830 80.0 x 40.0 x 21 mm 70 mm 11.0 W 15.0 W A3 0.110 A 0.104 A 0.62 0.60 85 C -25... 50 C 1 x 13 W TC-TEL PC 1x5-16 W BASIC 24138830 80.0 x 40.0 x 21 mm 70 mm 11.5 W 15.5 W A3 0.112 A 0.106 A 0.63 0.61 85 C -25... 50 C 1 x 16 W TC-DD PC 1x5-16 W BASIC PCB 24138836 56.6 x 36.5 x 17 mm 14.0 W 18.0 W A3 0.130 A 0.121 A 0.63 0.62-25... 50 C 1 x 10 W TC-DEL PC 1x5-16 W BASIC PCB 24138836 56.6 x 36.5 x 17 mm 8.5 W 11.5 W A3 0.089 A 0.084 A 0.59 0.57-25... 50 C 1 x 13 W TC-DEL PC 1x5-16 W BASIC PCB 24138836 56.6 x 36.5 x 17 mm 12.0 W 15.5 W A3 0.112 A 0.106 A 0.63 0.61-25... 50 C 1 x 5 W TC-SEL PC 1x5-16 W BASIC PCB 24138836 56.6 x 36.5 x 17 mm 4.5 W 6.5 W A2 0.055 A 0.051 A 0.54 0.53-25... 50 C 1 x 7 W TC-SEL PC 1x5-16 W BASIC PCB 24138836 56.6 x 36.5 x 17 mm 6.0 W 8.0 W A2 0.065 A 0.063 A 0.56 0.53-25... 50 C 1 x 9 W TC-SEL PC 1x5-16 W BASIC PCB 24138836 56.6 x 36.5 x 17 mm 7.5 W 10.0 W A2 0.078 A 0.073 A 0.58 0.57-25... 50 C 1 x 11 W TC-SEL PC 1x5-16 W BASIC PCB 24138836 56.6 x 36.5 x 17 mm 11.0 W 15.0 W A3 0.110 A 0.104 A 0.62 0.60-25... 50 C 1 x 13 W TC-TEL PC 1x5-16 W BASIC PCB 24138836 56.6 x 36.5 x 17 mm 11.5 W 15.5 W A3 0.112 A 0.106 A 0.63 0.61-25... 50 C 1 x TC-DEL PC 1x BASIC 24138829 80.0 x 40.0 x 21 mm 70 mm 15.5 W 19.0 W A3 0.135 A 0.128 A 0.64 0.62 85 C -25... 50 C 1 x TC-TEL PC 1x BASIC 24138829 80.0 x 40.0 x 21 mm 70 mm 15.0 W 19.0 W A3 0.135 A 0.128 A 0.64 0.62 85 C -25... 50 C 1 x TC-DEL PC 1x BASIC PCB 24138835 56.6 x 36.5 x 17 mm 15.5 W 19.0 W A3 0.135 A 0.128 A 0.64 0.62-25... 50 C 1 x TC-TEL PC 1x BASIC PCB 24138835 56.6 x 36.5 x 17 mm 15.0 W 19.0 W A3 0.135 A 0.128 A 0.64 0.62-25... 50 C 1 x 28 W TC-DD PC 1x26 W BASIC1 22176208 80.0 x 40.0 x 21 mm 70 mm 21.5 W 25.0 W A2 0.180 A 0.170 A 0.62 0.61 80 C -25... 45 C 1 x 26 W TC-DEL PC 1x26 W BASIC 22176208 80.0 x 40.0 x 21 mm 70 mm 20.5 W 24.0 W A2 0.180 A 0.170 A 0.62 0.61 80 C -25... 50 C 1 x 26 W TC-TEL PC 1x26 W BASIC 22176208 80.0 x 40.0 x 21 mm 70 mm 21.0 W 24.5 W A2 0.180 A 0.170 A 0.62 0.61 80 C -25... 50 C 1 For enclosed luminaires to fulfil the requirement of circuit power 25 W according to EN 61000-3-2. For AC operation only. 2 Temperature specification printed circuit board www.tridonic.com 2

Standards EN 55015 EN 61000-3-2 EN 61347-2-3 EN 61347-2-4 EN 61547 AC operation Mains voltage: 220 240 V 50 / 60 Hz 198 264 V 50 / 60 Hz including safety tolerance (±10 %) 202 254 V 50 / 60 Hz including performance tolerance (+6 % / -8 %) Min. lamp starting temperature -25 C DC operation 220 240 VDC 198 264 VDC certain lamp start 176 264 VDC operating possible Min. lamp starting temperature -25 C With a DC supply L and N terminals are interchangeable. EOS/ESD safety guidelines The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/com/en/technical-docs.asp Harmonic distortion in the mains supply EMC standard EN 61000-3-2 for lighting equipment with active input power 25 W. All ballasts comply with the standard EN 61000-3-2 to operate lighting equipment with an active input power 25 W where distortion limits for current drawn from the supply are 86 % for 3 rd harmonic and 61 % for 5 th harmonic only. Remark The EMC standard applies to the luminaire and reflects the specific properties of each fitting whether single or multi-lamp. Ballast lumen factor Type type Wattage AC/DC-BLF at 230 V, 50 Hz PC 1x4-13 W BASIC T5 1x4 W 1.00 PC 1x4-13 W BASIC T5 1x6 W 1.03 PC 1x4-13 W BASIC T5 1x8 W 1.01 PC 1x4-13 W BASIC T5 1x13 W 0.93 PC 1x4-13 W BASIC TC-DD 1x10 W 0.98 PC 1x5-16 W BASIC TC-DD 1x16 W 0.99 PC 1x5-16 W BASIC TC-DEL 1x10 W 0.95 PC 1x5-16 W BASIC TC-DEL 1x13 W 1.00 PC 1x5-16 W BASIC TC-SEL 1x5 W 0.98 PC 1x5-16 W BASIC TC-SEL 1x7 W 0.96 PC 1x5-16 W BASIC TC-SEL 1x9 W 0.98 PC 1x5-16 W BASIC TC-SEL 1x11 W 1.03 PC 1x5-16 W BASIC TC-TEL 1x13 W 1.00 PC 1x BASIC TC-DEL 1x 0.96 PC 1x BASIC TC-TEL 1x 0.96 PC 1x26 W BASIC TC-DD 1x28 W 0.85 PC 1x26 W BASIC TC-DEL 1x26 W 0.91 PC 1x26 W BASIC TC-TEL 1x26 W 0.97 Abnormal operation protection All ballasts are equipped with a protection circuit against abnormal operation. The circuit is used to shut down the ballast if the lamp fails to strike, or if the lamp is defect. The ballast can be restarted after shut down by turning off the supply for 10 seconds or by replacing the lamp. Ingress protection IP 20 for boxed versions Protection class The ballasts are suitable for use in class I or class II luminaires. Energy class CELMA EEI = A2 / A3 1) 1) according to the EU directives on ecodesign requirements (EC) No. 245/2009 and (EC) No. 347/2010 matrix TC-SEL 5 W 7 W 9 W 11 W TC-DEL 10 W 13 W 26 W TC-TEL 13 W 26 W T5 4 W 6 W 8 W 13 W TC-DD 10 W 16 W 28 W 4 13 W 5 16 W 28 W www.tridonic.com 3

Maximum loading of automatic circuit breakers Automatic circuit breaker type C10 C13 C16 C20 B10 B13 B16 B20 Installation Ø 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 PC 1x4 13 W Basic 90 117 144 181 90 117 144 181 PC 1x5 16 W Basic 80 106 130 163 80 106 130 163 PC 1x14 21 W Basic 56 83 102 127 28 54 102 127 PC 1x Basic 76 99 122 153 76 99 122 153 PC 1x18 24 W Basic 56 73 90 112 28 54 90 112 PC 1x26 W Basic 56 71 88 110 28 54 88 110 Max. load per MCB at supply voltage U n = 230 V Hottest point for the open PCB When open PCB version are supplied it is the responsibility of the fitting/housing manufacturer to ensure the circuit board is adequately protected from dust and moisture and that no live parts are accessible to the end user during operation or when changing the lamp. Be aware that the maximum temperature limits of the devices are not exceeded. The max. temperature values can be taken from the attached table (max. device temperature). The exact measurement points on the devices are shown in the graphic Temperature measurement points. Temperature range from -25 C to +50 C tc 39 27 EC1 Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %) R20 EC1 Q2 Q1 R20 R20 Q2 Storage temperature: -40 C up to max. +80 C Q1, Q2 The devices have to be within the specified temperature range (ta) before they can be operated. Max. device temperature Device Max. temperatur EC1 Q1 R20 110 C Q1, Q2 120 C EC1 (4 13 W) 85 C EC1 (5 16 W) 90 C EC1 () 95 C Temperature measurement points EC1 Q1, Q2 R20 www.tridonic.com 4

Wiring advice The lead length is dependent on the capacitance of the cable. Ballast Terminal Maximum capacitance allowed Type Cold Hot Cold Hot PC 1x4 13 W Basic 1, 2 3, 4 120 pf 60 pf PC 1x5 16 W Basic 1, 2 3, 4 120 pf 60 pf PC 1x Basic 1, 2 3, 4 120 pf 60 pf PC 1x26 W Basic 1, 2 3, 4 120 pf 60 pf With standard solid wire 0.5 / 0.75 mm² the capacitance of the lead is 80 pf/m. This value is influenced by the way the wiring is made. In borderline cases the capacitance must be measured inside the luminaire. connection should be as short as possible and be made with symmetrical wiring. To avoid the damage of the control gear, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.) Installation instructions Wiring type and cross section The wiring can be in flexible cable with ferules or solid with a cross section of 0.5 1.5 mm². Strip 9.5 mm of insulation from the cables to ensure perfect operation of push-wire terminals. wire preparation: 0.5 1.5 mm² RFI Tridonic ballasts are RFI protected in accordance with EN 55015. To operate the luminaire correctly and to minimise RFI we recommend the following instructions: Connection to the lamps must be kept as short as possible Mains leads should be kept apart from lamp leads (ideally 5 10 cm distance) Do not lead mains leads too closely along the electronic ballast Keep the distance of lamp leads from the metal work as large as possible Mains wiring to be twisted when through wiring Keep the mains leads inside the luminaire as short as possible 8.5 9.5 mm Release of the wiring Press down the push button and remove the cable from front. Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least 2 MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted. Additional information Wiring diagram Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services No warranty if device was opened. PC BASIC 1 2 3 4 hot leads leads 3, 4 max. 0.5 m (< 60 pf) leads 1, 2 max. 1.0 m (< 120 pf) www.tridonic.com 5