Electromotoric Actuators



Similar documents
RRV934. Multi-controller. Synco living

Butterfly Valves PN 6/10/16 for flanged connection

Thermostatic Actuators

Adjustable room thermostat for heating only or cooling only systems

2- and 3-port valves with flanged connections, PN 10

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Air damper actuators

HERZ-Thermal Actuators

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

Actuator for modulating control AME 435

Digital input modules

Electric Rotary Actuator - On/Off or programmable control actuator

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Flush-mounted room thermostats

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Emergency lighting units EM powerled

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Heating Controller. Building Technologies HVAC Products

HCR3.2/.. Chipcard reader HOTEL SOLUTION

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Room Temperature Sensors

Voltage Regulator SPAU 341 C. Product Guide

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Safety technique. Emergency stop module BO 5988 safemaster

TX OPEN RS232/485 module

BB800 Off-Grid Solar System

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Electronic Control Devices The European Product Catalogue 2007

Actuators. Building Technologies HVAC Products

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

RM4TG20 three-phase network control relay RM4-T - range V

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Pluggable interface relays CR-P Pcb relays

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Instruction Manual Differential Pressure Transmitter

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

Drayton Digistat +2RF/+3RF

Electric Lifting Cylinder TV / KV 5 XE Load up to N

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Duct Humidity Transmitter

ABB i-bus KNX SA/S Switch Actuators Product Manual

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

SINEAX U553 Transducer for AC Voltage

Quick running actuator

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Please also see 10 golden rules for correct Saniflo installation on

47000 SERIES - ELECTRONIC TRANSFORMERS

Power Supplies 3. SDN-P DIN Rail Series

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

OZW30. Central Unit SYNERGYR

BITMAIN. APW PSU Series User Guide

Automatic Voltage Regulator User s Manual

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Vario-Series Accessories

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Knob Potentiometer with Switch

Input module, input/output module

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Inductive sensor NI10-M18-Y1X-H1141

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Differential Charge Amplifier

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Flush-mount room temperature sensor AQR2531ANW.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

DS 600. A contact free flux gate based current measurement sensor 600A rms

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Condensate water pump with neutralisation system

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N


WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Digital Pressure Measuring Instrument MDR480

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

User Manual THR840DUK Digital Thermostat

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

Contents. Document information

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Transcription:

OEM SQS35954 with spring return function, without manual adjuster SQS35903, SQS35905, SQS85900, without spring return function, with manual adjuster Electromotoric Actuators for VVG549, VVP459, VXP459, VVG44 and VXG44 valves SQS359 SQS85900 SQS359 operating voltage AC 230 V, 3-position control signal SQS85900 operating voltage AC 24 V, 3-position control signal operating voltage AC 24 V, DC 0 10 V or 0 1000 Ω control signal Positioning force 250 to 400 Direct mounting on valves; no adjustments required Optional auxiliary switch for extra functions with SQS35903, SQS85900 With or without spring return function to DI 32 730 Position indication Manual adjuster on actuators without spring return function Use For operation of Siemens valves VVG549, VVP459, VXP459, VVG44 and VXG44 with 55 mm stroke for water-side control of hot water and cooling water in heating, ventilation and air conditioning systems In conjunction with the ASK30 mounting kit, the former Landis & Gyr-valves with 4 mm or 55 mm stroke can also be operated: X3i, VVG45, VXG45, VXG46, VVI51 CE1Q4573en Building Technologies 07122006 HVAC Products

Type summary Type reference Operating voltage Positioning signal Positioning time at 50 Hz Spring return function Spring return time SQS35903 SQS35905 SQS35954 AC 230 V 3-position 35 s o 15 s 20 s es 5 s SQS85900 AC 24 V 150 s DC 0 10 V 0 1000 Ω 35 s o Accessories Auxiliary switch ASC96 4573Z04 Suitable for actuator types SQS35903 and SQS85900 Switching point adjustable from 0100 % stroke (refer to «Technical data») Order Example: When ordering, please give the quantity, product name, type reference, and any accessories required 20 actuators SQS35903 and 20 auxiliary switches ASC96 Delivery The actuators are delivered in packs of 20 pieces Actuators, valves and accessories are supplied in separate packages Equipment combinations Type D P class k vs [m 3 /h] Data sheet SQS35903 SQS35905 SQS35954 SQS85900 VVG549 1525 P 25 025 63 Q4380 VVP459 063 25 Q4845 VXP459 1540 P 16 VVG44 025 25 4364 VXG44 4464 The admissible differential pressures p max and p s for the complete motorized valve are shown in the relevant Data Sheets Technical design / mechanical design Features and benefits Electromotoric actuator, maintenance-free Reversible synchronous motor Antilocking gear train Load-dependent switch-off in stroke limit positions The reversible synchronous motor is driven by a 3-position or a proportional DC 010 V or 0 1000 Ω control signal The stroke is generated via an antilocking gear train 3-position Voltage at : Stem extends, valve opens control signal Voltage at : Stem retracts, valve closes o voltage at or : Actuator holds the current position 2/8 HVAC Products 07122006

DC 0 10 V or 0 1000 Ω control signal Selecting the flow characteristic The valve opens / closes in proportion to the control signal at or R At DC 0 V or 0 Ω the valve is closed (A AB) When power supply is removed, the actuator maintains its current position Connector S1 (under the cover, on the printed circuit board) can be repositioned to change the flow characteristic of valves from «equal percentage» to «linear»; in all cases the flow characteristic relates to the through-port of the valve Position of S1 S1 connected to A and C: equal-percentage flow characteristic (factory setting) S1 connected to B and C: linear flow characteristic S1 A C B R - M S1 A C B R - M A C 4573Z01 C B Ω 4573Z02 Flow characteristic Volumetric flow rate k V100 Relationship between the DC 0 10 V or 0 1000 Ω control signal and the volumetric flow rate Control signals: = DC 010 V R = 01000 Ω; cut through R M bridge 4573D02 Flow characteristic log = Equal-percentage valve characteristic (factory setting) lin = Linear valve characteristic k V0 0 V 10 V 0 Ω 1000 Ω Control signal Flow range k &V100 = Volumetric flow 100% k = V0 & Volumetric flow 0 % Design 4573Z03 1 2 5 4 3 1 Manual adjuster (SQS35903, SQS35905, SQS85900, ) 2 Position indication 3 Coupling nut for valve neck 4 Housing 5 Removable cover Terminal strip 11 12 L 1 SQS3590, SQS85900 1 Terminal strip 4573Z18 U M R G G0 21 4573Z17 S1 A C B R - M 1 2 3 1 SQS35954 1 Terminal strip (terminal 21 for 1 Terminal strip spring return function) 2 «lin» / «log» connection 3 R M bridge 4573Z05 3/8 HVAC Products 07122006

Engineering notes The actuators must be electrically connected in accordance with local regulations and the connection diagrams Caution Safety regulations and restrictions designed to ensure the safety of people and property must be observed at all times Admissible temperatures, refer to «Technical data» If an auxiliary switch is required, its switching point should be indicated on the plant schematic Mounting notes Mounting Instructions are enclosed in the product packaging Overview Mounting Instructions Type reference Mounting Instructions Type reference Mounting Instructions SQS35903 SQS35905 SQS35954 74 319 0315 0 M4579 SQS85900 4 319 5628 0 ASC96 74 319 0495 0 M45792 4 319 5566 0 G45731 Instructions for fitting the actuator to the valve are shown on the back of the actuator housing Orientation 90 90 4362Z01 Commissioning notes When commissioning the system, check wiring and the functions In addition, select or check the auxiliary switch settings Manual adjuster 3-position control Switching off the positioning signal The valve can be fully closed (= 0 % stroke) by turning the manual adjuster counterclockwise Control is automatically resumed when the positioning signal returns Every actuator must be driven by a dedicated controller (refer to «Connection diagrams») Maintenance notes The actuators are maintenance-free When servicing the actuator: Switch off pump and power supply Close the main shutoff valve in the pipework Release pressure in the pipes and allow them to cool down completely If necessary, disconnect electrical connections from the terminals The actuator must be correctly fitted to the valve before recommissioning 4/8 HVAC Products 07122006

Repair Disposal The actuator can not be repaired It has to be replaced as a complete unit The device contains electrical and electronic components and must not be disposed of together with domestic waste This applies in particular to the PCB Legislation may demand special handling of certain components, or it may be sensible from an ecological point of view Current local legislation must be observed Warranty The technical data relating to specific applications are valid only in conjunction with the valves listed in this Data Sheet under «Equipment combinations» The use of the actuators in conjunction with third-party valves invalidates all claims under Siemens Switzerland Ltd / HVAC Products warranty Technical data SQS35903 SQS35905 SQS35954 SQS85900 Power supply Operating voltage AC 230 V ± 15 % AC 24 V ± 20 % Frequency 50 Hz Power consumption 35 VA 45 VA 6 VA 2 VA 45 VA End switches switching capacity, terminals 11 or 12 AC 250 V, 6 A resistive 25 A inductive AC 250 V, 6 A resistive 25 A ind Signal inputs Terminals, 3-position Terminal DC 0 10 V, max 01 ma Terminal R 0 1000 Ω Signal output Terminal U DC 010 V, max 05 ma Parallel operation of actuators not possible max 10 Operating data Positioning time in control mode for 35 s 15 s 20 s 150 s 35 s opening / closing Positioning time with spring return 5 s for closing Positioning force 400 250 300 400 ominal stroke 55 mm Admissible temperature of medium in the valve 1 130 C (short-time up to 150 C) Electrical connections Cable entry 2 openings 205 mm (for M20) orms and standards CE conformity EMC directive 89/336/EEC Low-voltage directive 73/23/EEC Housing protection standard IP 54 to E 60529 Dimensions / Weight Dimensions refer to «Dimensions» Weight without packaging 05 kg 06 kg 05 kg Materials Actuator housing Plastics Housing cover and manual adjuster Plastics Gear train Plastics Stem with coupling Metal Plastics Accessories Auxiliary switch ASC96 switching capacity AC 250 V, 3 A resistive 3 A inductive AC 250 V, 3 A resistive 3 A inductive HVAC Products 07122006 5/8

General environmental conditions Operation IEC 721-3-3 Transport IEC 721-3-2 Storage IEC 721-3-1 Environmental conditions Class 3K5 Class 2K3 Class 1K3 Temperature 5+50 C 25+70 C 5+50 C Humidity 595 % rh < 95 % rh 595 % rh Internal diagrams SQS359 3 100% M 0% M Cm1 Cm2 c1 Cm1 11 12 L 4 5 SQS35903, SQS35905 AC 230 V, 3-position, without spring return function Cm1 Cm2 c1 L 4573G01 End switch 100 % stroke End switch 0 % stroke ASC96 auxiliary switch can be fitted (in SQS35903) Potential-free auxiliary terminal 21 n SQS35954 100% 0% Cm2 AC 230 V, 3-position, with spring return function 4573G03 Cm1 End switch 100 % stroke Cm2 End switch 0 % stroke 21 Spring return function SQS85900 3 100% M 0% Cm1 Cm2 c1 11 G 12 L 4 5 90190 SQS85900 AC 24 V, 3-pos without spring return function Cm1 End switch 100 % stroke Cm2 End switch 0 % stroke c1 ASC96 auxiliary switch can be fitted L Potential-free auxiliary terminal Connection diagrams SQS359 L 4573A01 (L) (L) 11 () Q1 () Q2 () 1 () Q1 () Q2 () 2 13 12 F1 AC 230 V 21 1, 2 Controller Actuator SQS35903, SQS35905 Actuator SQS35954 L System potential AC 230 V System neutral Q1, Q2 Controller contacts F1 Maximum limiter (spring return function) 6/8 HVAC Products 07122006

SQS85900 SP 4505A02 (G) (G) Q1 Q2 Q1 Q2 (G0) () () 1 (G0) () () 2 AC 24 V G G S 1, 2 Controller, Actuator SP System potential AC 24 V S System neutral Q1, Q2 Controller contacts SP 4573A02 (G) () (G0) R P AC 24 V G G R M U G0 G0 S SP Controller Actuator System potential AC 24 V S R P System neutral Position indicator, frost detector Position transmitter ote If a device is connected to terminal R, the factory-fitted bridge across R M on the printed circuit board must be cut through Connection terminals U M R G G0 4573Z06 Position indicator DC 0 10 V Measuring neutral (= G0) Signal input 0 1000 Ω Signal input DC 0 10 V Operating voltage AC 24 V: system potential SP Operating voltage AC 24 V: system potential S HVAC Products 07122006 7/8

Dimensions Dimensions in mm 128 60 68 80 4579M01 134 120 28 88 G¾" 111* 32 ø205 (M20) * Height of actuator after fitting on valve > 100 mm Minimum clearance from wall or ceiling > 200 mm for mounting, connection, operation, service etc 8/8 2005 2006 Siemens Switzerland Ltd Subject to alteration HVAC Products 07122006