SIU-102 Manual, Rev 050816. Warner Instruments 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax



Similar documents
DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

User Manual. CFG253 3 MHz Function Generator

±15 V Current-Limited Power Supply

TIG INVERTER INSTRUCTION MANUAL

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

Model SPDT Relays

US Installation Manual Smappee Monitor

AutoRanging Digital MultiMeter

Manual Ranging MultiMeter

64-CHANNEL INTEGRATED AMPLIFIER

i410/i1010 AC/DC Current Clamp

PagePac PAGEPAL V

User s Manual Before using the inverter, you need to read and save the safety instructions.

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

DC Electronic Loads 8500 series

Model PS-4001 Power Supply User Instructions

HVA200 High Voltage Amplifier

PEDAL POWER DIGITAL. User s Manual.

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Current Probes. User Manual

PSC RF Multi SR Six Pack

Adjustment functions for both span and shift have been incorporated

INSTRUCTION MANUAL MODEL PCD-88

700/732 SERIES. 5mm HOUR METERS & COUNTERS. CURTIS INSTRUMENTS, INC. 200 Kisco Avenue, Mt. Kisco, NY Tel. (914) FAX (914)

CONTROL SWITCHER User s Manual (Preliminary)

Multipurpose Analog PID Controller

User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams

PERF10 Rubidium Atomic Clock

How To Use A Cdm250 Digital Multimeter

Instructions A Amp AC/DC Current Probe

ADM1TE 5/30A DIN rail single phase two wire energy meter

3500/62 Process Variable Monitor

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

PEDAL POWER 4x4. User s Manual.

PSP3. Stereo M/S preamplifier. User manual

DC POWER SUPPLY ALIMENTATION C.C.

User s Guide. Publication number E June Copyright Agilent Technologies All Rights Reserved. E2697A 1 MΩ Impedance Adapter

User's Guide. True RMS Industrial Multimeter

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Preset Counter signo 721

12-Volt 10-Amp Regulated Power Supply

Contents. Document information

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

USER MANUAL. Kramer Electronics, Ltd. Models:

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Amplified High Speed Fiber Photodetectors

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

R&S ZNC Vector Network Analyzer Specifications

Original instructions Tina 3A/Aps Adaptor unit

CIC-50. T1/E1 G.703 Interface Converter Installation and Operation Manual (Accessory Product for use only with Comtech EFData CDM-550/550T Modems)

BroadBand PowerShield. User Manual

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

MIDI control allows the Split Personality to be used remotely in rack systems, or integrated into MIDI controlled setups for easy preset recall.

TMS TANK MANAGEMENT SYSTEM

Analog Servo Drive 25A8

PowerStar Mini Triple Play TM

Fiber Optics. Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 SFH551/1-1V

APG-XT APG-HPD. Operating Manual. Internal APG (Analog Programming) Interface for XT/HPD Series Programmable DC Power Supply

Product and functional description

LDG DTS-4/4R Desktop Coaxial Switch / Remote

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

Tina 2A/B Adaptor unit

Physics 3330 Experiment #2 Fall DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

FIBRE-OPTICS POWER METER INSTRUCTION MANUAL

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Features, Benefits, and Operation

YSmart Technology Co.,Ltd

PicoScope 6000A/B Series

MegaPulse Defib-5P Instruction Manual

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Installation and Operation Guide for PD4100 Series Power Control Centers

FREQUENCY RESPONSE ANALYZERS

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Research RF Sputtering Packages

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Installation and Operation Guide for PD4000 Series Power Control Center

F2400 FOM II Series Fiber Optic Modem Technical Manual

MODEL 1211 CURRENT PREAMPLEFIER

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

R&S ZNBT8 Vector Network Analyzer Specifications

USER MANUAL. Kramer Electronics, Ltd. Models:

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

12 Volt 30 Amp Digital Solar Charge Controller

OPERATION MANUAL VALVE CHECKER G

Transcription:

SIU-102 Manual, Rev 050816 Bipolar Stimulation Isolation Unit Model SIU-102 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax

SIU-102 Manual, Rev 050816 2 Table of Contents INTRODUCTION...3 NOMENCLATURE...4 Text conventions... 4 CONTROL DESCRIPTION...5 Pulse Mode Switch... 5 Output Control Switches... 5 Pulse In... 5 Pulse Out... 6 Connecting Cable... 6 SPECIFICATIONS...7 WARRANTY...7 CERTIFICATIONS...8

SIU-102 Manual, Rev 050816 3 The SIU-102 is an isolated Bipolar Stimulator primarily designed for use with imaging chambers having field stimulation electrodes. Bipolar, unipolar positive, unipolar negative, positive DC and negative DC stimulations are easily programmed using the front panel controls. Constant current and constant voltage delivery modes are also possible. The SIU-102 features optical isolation at the input and transformer isolation at the output terminals. Timing pulses can be controlled by any device capable of generating a TTL level positive pulse (e.g., a computer with data acquisition). Output amplitude for all pulse types is set using a ten-turn potentiometer in conjunction with a range mode switch and duration is set using an external TTL signal. Features include: Constant current and constant voltage modes Bipolar, pulse and DC modes Optical coupling isolates the stimulator from pulse source Current to 100 ma Voltage to 100 V THIS EQUIPMENT IS NOT DESIGNED NOR INTENDED FOR USE ON HUMAN SUBJECTS

SIU-102 Manual, Rev 050816 4 NOMENCLATURE Text conventions This manual refers to amplifier controls at three functional levels; control blocks, specific controls within a block, and settings of specific controls. To minimize the potential for confusion, we have employed several text conventions which are specified below. Since our goal is to provide clarity rather than complexity, we welcome any feedback you may wish to provide. Warner Instrument product numbers are presented using bold type. References to specific controls are specified using NON-UNDERLINED SMALL CAPS. References to individual control settings are specified in italic type. Special comments and warnings are presented in highlighted text. Any other formatting should be apparent from context.

SIU-102 Manual, Rev 050816 5 CONTROL DESCRIPTION The instrument front panel contains all the controls for selecting voltage and current modes and for setting the amplitude, polarity and type of pulse. Pulse Mode Switch The PULSE MODE SWITCH is used to set the desired pulse shape. Options include positive (+) pulse, negative (-) pulse, bipolar, positive (+) DC and negative (-) DC. In bipolar mode, a positive pulse is applied during the initial phase, immediately followed by a negative pulse of equal duration and amplitude. The pulse amplitude is set by the controls in the next section (see below) and the duration is set by the TTL signal applied to the PULSE IN BNC. Bipolar pulse widths are user adjustable from 100 µs to 100 s and are per polarity. A red LED indicates when pulse length exceeds 100 s. The initial polarity of the pulse can be inverted by reversing the connections to the PULSE OUT JACKS. Output Control Switches Two controls are used to select constant current or constant voltage modes and to set the pulse amplitude or DC holding level. These controls are the 10-turn OUTPUT SET potentiometer and the OUTPUT RANGE switch. The OUTPUT RANGE is a 5-position switch selecting constant current modes in the first 3 positions and constant voltage modes in the last 2 positions. Constant current modes are 0 1 ma, 0-10 ma and 0-100 ma. The desired current is set using the lockable 10-turn OUTPUT SET potentiometer. A red COMPLIANCE LED indicates when the external resistance is too high, preventing the instrument from maintaining the set current value. Constant voltage modes are 0-10 V and 0-100 V. As above, the desired clamped voltage is set using lockable 10-turn OUTPUT SET potentiometer. Pulse In The PULSE IN BNC is used in conjunction with the OUTPUT CONTROL switches and is used to define the duration of the applied pulse. It is disabled, however, in positive (+) DC and negative (-) DC modes. In positive (+) pulse or negative (-) pulse modes, the length of a TTL high signal (3-5 V), applied to the PULSE IN BNC, will specify the duration of output pulse.

SIU-102 Manual, Rev 050816 6 In bipolar mode the pulse length of the TTL high signal defines the duration of the initial phase of the bipolar pulse. As is expected from a bipolar pulse, the second component of the pulse will have equal duration, but opposite amplitude. If a second TTL high signal is applied during the second phase of the bipolar pulse, the first pulse will continue to completion before the instrument accepts the new, incoming signal. NOTE: The length of the second PULSE IN signal may be shortened due to overlap with the currently executing bipolar pulse. However, the symmetry of the second bipolar pulse will be maintained. Pulse Out CAUTION: Dangerous voltages and currents are presented at the PULSE OUT connections. Extreme care must be taken to avoid serious personal injury. Output signals are delivered to the sample or chamber via the RED and BLACK PULSE OUT banana jacks. The RED and BLACK BANANA JACKS connect to the positive and negative side of the preparation, respectively. An OUTPUT TOGGLE SWITCH is provided to turn the pulse output on or off without need to access user settings. In the off position, the RED and BLACK OUTPUT JACKS are shorted together. As a safety measure, the LIGHTNING SYMBOL between the banana jacks lights red when the output voltage exceeds 30 V. Connecting Cable A special cable (not supplied), the CC-102, is available to facilitate connection from the PULSE OUT banana jacks and Warner s field stimulation chambers.

SIU-102 Manual, Rev 050816 7 SPECIFICATIONS Output Waveform Output Current Ranges Output Voltage Ranges Output Impedance Voltage Mode Output Compliance Output Polarity Amplitude Control Input Pulse Requirements Input Connector Output Connector Power Requirements Physical Size, H x W x D Shipping Weight Operating conditions DC, Current Pulse or Voltage Pulse 1, 10 and 100 ma 10 and 100 V 10 V Range: 1KΩ 100 V Range: 10KΩ 100 V Selected by Mode Switch Red connector is positive in any positive mode Red connector is negative in any negative mode Multi-turn dial TTL level, positive pulse 3 volt, 1 ma minimum Minimum Pulse Width: 100µs Maximum Pulse Width 100s (bipolar mode only) BNC Banana Jacks 90 to 270 VAC, 50/60 Hz, 10 VA 8.9 x 20 x 25.4 cm 3 kg Equipment is intended to be operated in a controlled laboratory environment. Temperature: 0-40 C Altitude: sea level to 2000 m Relative humidity: 0-95% WARRANTY The SIU-102 is warranted to be free from defects for a period of two years from date of shipment. will repair or replace at its option any parts that fail under normal use with the exception of the electrodes. NOTE: Repairs are performed at the factory. Shipping charges for the return to the factory are the responsibility of the customer. Warner will return the repaired item FOB destination.

SIU-102 Manual, Rev 050816 8 CERTIFICATIONS Declaration of Conformity CE MARKING (EMC) Application of Council Directive: 89/336/EEC Standards To Which Conformity Is Declared: EN55022 Class A EN61000-3-2 EN61000-3-3 EN50082-1:1992 EN61000-4-2 EN61000-4-3 ENV50204 EN610000-4-4 EN610000-4-8 EN610000-4-11 Manufacturer s Name: Manufacturer s Address: Equipment Description: Equipment Class: Model Numbers:, LLC 1125 Dixwell Avenue Hamden, CT 06514 Tel: (203) 776-0664 Power Controller ITE-Class A SIU-102 I the undersigned, hereby declare that the equipment specified above, conforms to the above Directive(s) and Standard(s). Place: Hamden, Connecticut USA Signature: Full Name: Burton J. Warner Position: President

SIU-102 Manual, Rev 050816 9 Declaration of Conformity CE MARKING (LVD) Application of Council Directive: 73/23/EEC Standards To Which Conformity Is Declared: Manufacturer s Name: Manufacturer s Address: Equipment Description: Equipment Class: Model Numbers: EN61010-1:1993, LLC 1125 Dixwell Avenue Hamden, CT 06514 Tel: (203) 776-0664 Power Controller Safety requirements for electrical equipment for measurement and laboratory use Class I SIU-102 I the undersigned, hereby declare that the equipment specified above, conforms to the above Directive(s) and Standard(s). Place: Hamden, Connecticut USA Signature: Full Name: Burton J. Warner Position: President

SIU-102 Manual, Rev 050816 10