DC Reference & Transfer Standards. Automated Voltage Measurement System



Similar documents
1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

DS 600. A contact free flux gate based current measurement sensor 600A rms

DC Electronic Loads 8500 series

2000 6½-Digit Multimeter

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

NetScanner System. Toronto: , Montreal: , Toll Free: ,

rigel 288 Electrical Medical Safety Analyser Key Features Applications

Handheld portable appliance testers

DCS Series 1 kw, 1.2 kw, & 3 kw

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Chassis, Power Supply, and Element Management

Multi-Function Ground

Insulation resistance testing. A complete solution for every person.

Migrating from dc voltage dividers to modern reference multimeters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

USB-500/600 Series Low-Cost Data Loggers and Accessories

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Multi-Range Programmable DC Power Supplies 9115 Series

Everything you need for protection scheme testing

USB-500/600 Series Low-Cost Data Loggers and Accessories

NGSS Data Consolidator (DC)

EGSTON Standard E2xFxWx 12W

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

Multi-Range Programmable DC Power Supplies 9115 Series

Mobile Communications DC Sources W

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

CompactLogix Power Supplies Specifications

iva Cable & Antenna Analyzer

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

USB-500 Series Low-Cost Data Loggers and Accessories

5000V Graphical Megohmmeter Model 5070

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

10 Multimeter. Users Manual

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Voltech DC1000. Precision DC Bias Current Source

1.44 kw Programmable DC Power Supplies XLN Series

BB800 Off-Grid Solar System

NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

1 Form A Solid State Relay

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Current Monitoring Kit

Calibrating DC Shunts: Techniques and Uncertainties

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

NETWORK ENABLED EQUIPMENT MONITOR

High Power Programmable DC Power Supplies PVS Series

Power Supplies 3. SDN-P DIN Rail Series

Considerations When Specifying a DC Power Supply

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

WEATHER STATION FOR SOLAR FARM MONITORING

Agilent 4339B/4349B High Resistance Meters

FREJA 300 Relay Testing System

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SL Series AC and DC Electronic Loads

Hand-held thermometer Model CTH7000

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Remote Monitoring and REC 501 Control Unit Product Guide

iva Cable & Antenna Analyzer

PSM 900 and PSM 1000 Personal Monitor Systems TWO SYSTEMS. INFINITE POSSIBILITIES.

MODEL 1211 CURRENT PREAMPLEFIER

TX2123 RS485 TO ETHERNET ADAPTOR

PXI Express Chassis with Integrated MXI-Express Remote Controller

OUTPUT CABLE CONNECTIONS:

TORKEL 820 Battery Load Unit

Actuator-Sensor-Interface

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

GT Sensors Precision Gear Tooth and Encoder Sensors

Voltage Regulator SPAU 341 C. Product Guide

Analog signal converters CC-E I/I Current / current isolators

Redundancy Module QUINT-DIODE/40

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

IBM United States Hardware Announcement , dated September 8, 2009

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Loop Calibration and Maintenance

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

T Substation Maintenance and Commissioning Test Equipment

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

DeltaV SISnet Repeater

USB-500 Series Stand-Alone, Low-Cost Data Loggers

STRATO LED Drivers 70W, Single output

Ron 3025 Crane Scale with 1"/25mm Display

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Features. Applications. Truth Table. Close

Fluke 3000 FC Series Test Tools Technical Data

Rackmount Intelligent Pressure Scanners

PowerGem Pro Uninterruptible Power Supply

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

New thermometers and accessories to grow your business

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Battery Powered Thermal Mass Flow Meters for Gases

MPR-Systems. Mini Power Racks 1200 W W

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

1650 Series Multifunction Installation Testers

Transcription:

DC Reference & Transfer Standards Automated Voltage Measurement System

New technology sets standard for automated DC intercomparison Integrated approach Although Direct Voltage is one of the fundamental measurement parameters in electrical metrology, no one has previously taken a fully integrated approach to the problem of Volt maintenance. Within a compact bench or rack mount unit, the Fluke 7000 Volt Maintenance System combines multiple Voltage reference modules, high integrity hardware averaging, and advanced scaning and measurement technology. Of particular value to the modern commercial calibration laboratory is full automation of Volt maintenance. The 7000 achieves this through the optional 7050 Windows TM based software and a powerful Microsoft Excel TM add-in. Automating the Volt Complete automation of Volt maintenance significantly reduces the burden and risk of error in maintaining fully traceable standards for the Volt. Most of the Volt maintenance systems currently in use consist of equipment and software from a variety of manufacturers. This often leads to variability in set-up, difficulties in the management of expanded uncertainty and obtaining support for the system all of which results in inefficient use of time. Patented technology The heart of the Fluke 7000 Series is the fully isolated, compact 7000 solid state 10V and 1.018V direct Voltage standard. Designed to be robust and portable, its internal batteries support hot shipment and plug-in. However, should complete power be lost at any time, patented Reference Conditioning technology overcomes reference device hysteresis and restores the last powered value to the module. The 7000 modules also feature patented DC-DC convertor technology, which achieves unparalleled isolation from the external AC- DC Line power adaptor. This makes the 7000 series particularly well suited to Josephson Junction direct comparison, as it speeds up intercomparison and reduces measurement uncertainty. Ten, four and single housings are available for 7000 modules. The ten and four housings will accept either the Nanoscan or Transref units. The Nanoscan provides hardware averaging, a 4-wire buffer and remote control of its scan and measurement functions. The Transref provides a convenient hardware averaged output as well as the ability to access the output of individual modules using the Nanoscan System. The 70004T is an ideal product for support of transfers between single or multiple working standards at remote locations. Furthermore high isolation, low thermal EMF optical MOSFET technology is used to switch the output of each module through the housing backplane to the hardware average. Full reversal switching further ensures maximum rejection of thermal EMF offsets.

Statistical methods and extended benefits The 7000 Volt Maintenance System uses reversal scanning and statistical methods based on reference independence to reduce measurement uncertainty for each module. External DC references, including the Fluke 732A or 732B are well established and although of differing technology, can be included in the intercomparison process, either by direct connection to the Nanoscan module (one external input) or via multiple 7000S External Scan Modules. Furthermore a Nanoscan and a Transref unit can be linked together to form a powerful combination of Reference, Working and Transportable Standards. A measurement system will support a maximum of 21 internal or external Voltage references. Low-noise high-sensitivity The Nanoscan unit contains a low-noise high-sensitivity null detector that compares individual 10-Volt reference outputs with the hardware average of a selected group of 7000 Reference modules. The use of the hardware average provides for ultra low noise comparisons with external standards such as the Josephson Junction array. The Nanoscan is supplied with an optical fiber interface for direct connection to a PC via its RS232 port. Scan control and measurement analysis is provided by the 7050 software. Timed scan sequences The 7050 Windows TM based software and its Microsoft Excel TM add-in completes the package and enables you to realize the full potential of 7000 System automation. The software facilitates rapid installation, detection of hardware configuration and set-up, control and monitoring of complex scan sequences. The values of the hardware average and the predicted value of each Voltage reference are computed, as are drift rates and associated uncertainties. Scan results can be transferred to Excel TM for further numerical and graphical analysis.the generation of reports, certificates and graphs as a result of importing and exporting traceability is also supported.

Specifications Model 7000/7001 7004N/T 7010N/T 732B 734A [1] 10V Output Stability (± ppm), 90 days 0.9 0.8 0.7 0.7 0.7 Stability (± ppm), 1 year 1.8 1.2 1.0 1.6 1.2 Predictability After 5 points, 3 mo. apart ±0.5 ppm/year typ. ±0.2 ppm/year typ. ±0.1 ppm/year typ. ±0.4 ppm/year typ. ±0.2 ppm/year typ. Temperature Coefficient (15-35 C) < 0.05 ppm < 0.03 ppm < 0.02 ppm < 0.04 ppm < 0.04 ppm Noise 0.01 to 10Hz < 0.10 ppm RMS < 0.05 ppm RMS < 0.03 ppm RMS < 0.06 ppm RMS < 0.03 ppm RMS Std. dev. of 90 days regression < 0.10 ppm RMS < 0.06 ppm < 0.04 ppm < 0.065 ppm < 0.04 ppm RMS Hysteresis recovery (after battery discharge ) < 0.1 ppm [2] < 0.1 ppm [2] < 0.07 ppm [2] 0.2 ppm [3] 0.2 ppm [3] Output Current 12 ma 12 ma 12 ma 12 ma 12 ma Output Resistance < 10 mohm 125 Ohm [4] 50 Ohm [3] < 1 mohm < 1 mohm 10V 4 wire Output (relative to Average) Output current n/a 12mA max. 12mA max. n/a n/a Load Regulation Zero to 2mA n/a < 0.1 ppm < 0.1 ppm n/a n/a 2mA to 12mA n/a < 0.5 ppm < 0.5 ppm n/a n/a External Standard Input Range: n/a +9.990 to +10.010V +9.990 to +10.010V n/a n/a Input Impedance n/a 100 Mohm + 10pF 100 Mohm + 10pF n/a n/a Null Detector Range: n/a -9999.9 to +9999.9 µv -9999.9 to +9999.9µV n/a n/a Measurement Errors Chan. to Average: n/a ± 0.3% of difference ± 0.3% of difference n/a n/a Chan.to out of Ave. n/a ± 0.1% of difference ± 0.1% of difference n/a n/a External Standard n/a ± 0.001% ± 0.001% n/a n/a Chan. to Chan. n/a ± 0.1 µv ± 0.1 µv n/a n/a Oven Temperature Monitor Accuracy: n/a ± 3 C ± 3 C n/a n/a Stability/Repeatability: n/a ± 0.1 C/year ± 0.1 C/year n/a n/a Battery Type NiMH NiMH NiMH lead acid lead acid Back-up Period 16 hrs 16 hrs 16 hrs 72 hours 72 hours Recharge time (typical) 2 hour 2 hour 2 hour 24 hours 24 hours Half Life: 5 yrs. 5 yrs. 5 yrs. Reference conditioning Yes Yes Yes No No (power loss recovery) Temperature Operating +15 C to 35 C +15 C to 35 C +15 C to 35 C +15 C to 35 C +15 C to 35 C Transit -18 C to 45 C -18 C to 45 C -18 C to 45 C -40 C to 50 C -40 C to 50 C Warm-up period 10 min. to ±0.1ppm 20 min to ±0.2 ppm 20 min to ±0.2 ppm 1 hour (power off for 1 hour (power off for of final output value 2 hours to final value 2 hours to final value less than 1 hour) less than 1 hour) Power < 1W < 6W < 12W < 10W < 40W Mechanical Dimensions 137 x 85 x 290 mm 133 x 449 x 355 mm 265 x 449 x 355 mm 135 x 99 x 419 191 x 432 x 502 (H x W x D) (3.5 x 2.1 x 11.4 in) (5.24 x 17.68 x 13.19 in) (10.43 x 17.68 x 13.19 in) (5.3 x 3.9 x 16.5 in) (7.5 x 17 x 19.75 in) Weight 2.1kg (4.5Ibs) 9.6kg (21.2Ibs) 20kg (44.1Ibs) 5.9 kg (13 lbs) 29.6 kg (65 lbs) General Safety UL3111 ; CE marked UL3111 ; CE marked UL3111 ; CE marked UL1244 ; CE marked UL1244 ; CE marked EN61010-1-1;1993 EN61010-1-1;1993 EN61010-1-1;1993 CSA C22.2 # 231 CSA C22.2 # 231 /A2;1995 ; CETL /A2;1995 ; CETL /A2;1995 ; CETL IEC 348 ; IEC 1010 IEC 348 ; IEC 1010 Notes: All specifications, including 732B, are stated with 98% Confidence Level [1] 734A specifications are using a mathematical average of four cells. [3] Conditioning not available. Specification assumes reference remains within a temp controlled environment. [2] After conditioning cycle and maintained within environments down to 10 C. [4] Actual resistance = 500/n, where n = number of references in the Average.

The simple and proven way to maintain and disseminate your volt Established approach The 732B is a Direct Voltage standard with 10V and 1.018V outputs. The 734A consists of four 732Bs, that are mechanically and electrically isolated, housed in a rackmountable enclosure. The 734A is designed to be a direct Voltage standard for primary or secondary calibration and standard laboratories. Because it is made up of four independent standards, intercomparisons of the standards and statistical methods can be used to reduce uncertainties significantly over time. Each 732B can be removed from the 734A and used as a portable standard to transfer a value from a primary 734A reference to remote service or production locations for traceability, without disturbing the primary reference. Small, portable and rugged Each standard is small, light and rugged, ideal for shipment. The long 72-hour battery life allows the 732B to be shipped over great distances under power. An optional external battery and charger extends battery life still further, to more than 130 hours. The 732B is robust and can withstand a lot of abuse. The outputs can be shorted indefinitely and are protected up to 1100V DC, 25mA, without damaging the cell or affecting its output. Confidence The 732B is based on the proven technology of the Fluke 732A. Thousands are now in service world wide in a variety of applications from maintaining an institutional reference to transferring values form national labs or Josephson Arrays. Stability Stability for each output is ± 1.6 ppm per year (10V) and ± 0.6 ppm per month (1.018V). Each10V output can drive up to 12 ma of current to simplify use with instrumentation like the 5700A. A fractional ppm Voltage reference for your facility With the 732B, the 734A, and now the 7000 Series it is remarkably easy to establish a fraction of a part-per-million Voltage reference in your laboratory. Over time, with frequent automated intercomparison of cells, and regular calibrations on one or more cells, you can reduce the uncertainty of a four cell unit by a factor of 3 or more. Artifact calibration package Combined with the Fluke 742A-1 and 742A-10k Resistance standards, a 732B, 7001 or 7004 make a tough and compact artifact calibration support package for instruments like the Fluke 5700A/5720A Calibrators or the Agilent 3458A Multimeter.

Ordering Information 7001 Solid-State 10-Volt DC Voltage Reference with External Power Supply 7000 10-Volt DC Voltage Reference (compatible with Model 7001, Model 7004N/7010N and Model 7004T/7010T) 7004T 7010T 7004N 7010N 4-Reference Transref Volt Maintenance System with 12V DC Power Supply 10-Reference Transref Volt Maintenance System with 12V DC Power Supply 4-Reference Nanoscan Volt Maintenance System complete with Low-Thermal Lead Set, Interface Cabling for a second Nanoscan/Transref unit, Fiber-Optic Cabling for connection to a PC, and a 12V DC Power Supply (requires at least one Model 7000 10-volt Solid State DC Voltage Reference Module) 10-Reference Nanoscan Volt Maintenance System complete with Low- Thermal Lead Set, Interface Cabling for a second Nanoscan/Transref unit, Fiber-Optic Cabling for connection to a PC, and a 12V DC Power Supply (requires at least one Model 7000 10-volt Solid State DC Voltage Reference Module) 7000S 10-Volt External Reference Input Module (installs into a Model 7004N, 7010N, 7004T or 7010T chassis) 7050 Software - PC Windows based Software for Controlling 7004N/7010N Nanoscan Systems 732B 734A DC Standard. Output calibration optional. Reference Standard. Includes four 732Bs in a rack-width enclosure. Calibration of each 732B output optional. See Accessories and Options below. Accessories and Options 7001-65 Ruggedized Transit Case complete with Environmental Monitor (for 7001) 7004-65 Ruggedized Transit Case with Environmental Monitor (for 7004) 7000-742A Artifact Resistance Standards comprising of 1x742A-1 Ohm and 1x742A-10K Ohm 732B-000 10V Output Voltage Calibration for one 732B, shipped hot* 732B-100 10V Output Voltage Calibration and Drift Rate Characterization for one 732B, shipped hot* 732A-7001 Enclosure. Holds up to four 732Bs. 732B-7001 External Battery and Charger 732B-7002 Transit Case. Holds one or two 732Bs, or one 732B and one 732B-7001 External Battery and Charger 5440B-7002 Low Thermal EMF Copper Plug-In Cables Y734A Rack-Mount Kit for 734A or 734A-7001 *Under power Fluke. Keeping your world up and running. For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 356-5116 In Canada (800)-36-FLUKE or Fax (905) 890-6866 In Europe/M-East/Africa (31 40) 2 678 200 or Fax (31 40) 2 678 222 From other countries (425) 356-5500 or Fax (425) 356-5116 Fluke Corporation PO Box 9090, Everett, WA USA 98206 Web access: http://www.fluke.com/ 2000 Fluke Corporation. All rights reserved. Trademarks are the property of their respective owners. DS249 / G0518NEN A / 1586169 B-ENG-N A