ADM1TE 5/30A DIN rail single phase two wire energy meter



Similar documents
DRM75A 230V 20/100A DIN rail single phase two wire energy meter

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

YSmart Technology Co.,Ltd

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

BroadBand PowerShield. User Manual

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

Advantium 2 Plus Alarm

R.C.C.B. s two-pole LEXIC

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

User s Manual Before using the inverter, you need to read and save the safety instructions.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

SURGE PROTECTIVE DEVICES

CompactLogix Power Supplies Specifications

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Safety Manual BT50(T) Safety relay / Expansion relay

TMS TANK MANAGEMENT SYSTEM

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

Model 1756 Test Lead Kit

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

CONTATORE ENEL MONOFASE/TRIFASE CONTATORE TRIFASE DI ENERGIA ELETTRICA FIGURA 1: SCHEMA DI INSTALLAZIONE

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Energy Management Energy Meter Type EM23 DIN

Online UPS. PowerWalker VFI 1000R/1U

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

How To Use A Cdm250 Digital Multimeter

Model UT33A: OPERATING MANUAL Table of Contents (1)

Quick Connect. quick - simple - efficient.

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

, User s Manual

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

TIG INVERTER INSTRUCTION MANUAL

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

Operating Manual Remote Cost Control Monitor

Adjustment functions for both span and shift have been incorporated

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Product and functional description

DLP-PU/E Instruction Manual

HM-W536 Install Guide

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Manual. Solar Fountain Mobile Phone Charger

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

HERZ-Thermal Actuators

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

MCR1900 Media Converter 19-Slot Chassis

RELAYS Solar Energy Systems

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Congratulations! Thank you!

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

AIR-CONDITIONER SPLIT TYPE

PowlVac Vacuum Integrity Tester

Power supply unit Model: PAC-SC50KUA

12 Volt 30 Amp Digital Solar Charge Controller

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Original instructions Tina 3A/Aps Adaptor unit

5235 Single Phase Credit Meter

Instructions A Amp AC/DC Current Probe

How To Use A Power Supply Unit (Upu)

Modular I/O System Analog and Digital Interface Modules

BMW Multi Tool User Manual

L5354 ControlNet Communications Interface

Bubble King. User Manual

Intersection Preassembled 19-inch Rack

Addendum to the Operating Instructions

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

T7560A,B,C Digital Wall Module

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Tina 2A/B Adaptor unit

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

AGILENT E5071C ENA NETWORK ANALYZER

Maximum Demand Control

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Cross-beam scanning system to detect slim objects. 100 mm in

Cooktop Low-Profile Ventilation Hoods

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

46120-F0 Solar Energy Training System

Transcription:

ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting. Technical support User manual

. Safety instructions Information for Your Own Safety This manual does not contain all of the safety measures for operation of the equipment (module, device), because special operating conditions, and local code requirements or regulations may necessitate further measures. However, it does contain information which must be read for your own personal safety and to avoid material damages. This information is highlighted by a warning triangle and are represented as follows, depending on the degree of potential danger. Warning This means that failure to observe the instruction can result in death, serious injury or considerable material damage. Caution This means hazard of an electric shock, failure to take the necessary safety precautions can result in death, serious injury or considerable material damage. Qualified personnel Commissioning and operation of the equipment (module, device) described in this manual may only be performed by qualified personnel. Qualified personnel in the sense of the safety information contained in this manual are persons who are authorized to commission, start up, ground and label devices, systems and circuits according to safety and Regulatory standards. Use for the intended purpose The equipment (device, module) may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by DMMetering. Proper handling The prerequisites for perfect, reliable operation of the product are proper transport, proper storage, installation and assembly, as well as proper operation and maintenance. When operating electrical equipment, certain parts of this equipment automatically carries dangerous voltages. Improper handling can therefore result in serious injury or material damage. Use only isolated tools. Do not connect while circuit is live (hot). Do not connect the meter to a 3 phase - 400VAC network. Place the meter only in dry surroundings. Do not mount the meter in an explosive area or expose the meter to dust, mildew and insects. Make sure the used wires are suitable for the maximum current of this meter. Make sure the AC wires are connected correctly before activating the current/voltage to the meter. Do not touch the meter connection clamps directly with your bare hands, with metal, blank wire or other material as you will have the chance of an electric shock and a possible chance for health damage.

Make sure the protection cover is placed after installation. Installation, maintenance and repair should only be done by qualified personnel. Never break the seals and open the front cover as this might influence the functionality of the meter, and will avoid any warranty. Do not drop, or allow physical impact to the meter as there are high precision components inside that may break. Exclusion of liability We have checked the contents of this publication and every effort has been made to ensure that the descriptions are as accurate as possible. However, deviations from the description cannot be completely ruled out, so that no liability can be accepted for any errors or omissions contained in the information given. The data in this manual is checked regularly and the necessary corrections are included in subsequent editions. We are grateful for any improvements that you care to suggest. Subject to technical modifications without notice. Copyright Copyright DMMetering March 2007 All rights Reserved. It is prohibited to pass on or copy this document or to use or disclose its contents without our express permission. Any duplication is a violation of the law and subject to criminal and civil penalties. All rights reserved, particularly in the event of a patent award or utility model registration. Registered trademarks DMMetering is registered trademark of Inepro Industries Ltd member of the Inepro Group. The other names appearing in this manual may be trade names the use of these names by third parties for their own purposes may infringe the rights of the owners..2 Foreword Thank you for purchasing the DMMetering ADMTE DIN rail single phase two wire energy meter. The DMMetering ADMTE energy meter is the most advanced type electronic kwh meter available at the market. With the DMMetering product range we have introduced a large scale of energy meters on the market suitable for 0V AC to 400V AC (50 or 60Hz). Besides the normal energy meters we also developed our own pre-paid meters with chip card, chip card re-loaders and a complete PC management control system. For more information on other product please contact our sales department at sales@dmmetering.com or info@inepro.com.hk. Although we produce the DMMetering ADMTE meter according to IEC 62053-2 and our quality inspection is very accurate there might always be a possibility that your product shows a fault or failure for which we do apologize. Under normal conditions your product should give you years of benefit and pleasure. In case there is problem with the energy meter you should contact your dealer immediately. All energy meters are sealed with a special seal. Once this seal is broken there is no possibility to claim for warranty. Therefore NEVER open an energy meter or break the seal of the energy meter. The warranty time is 6 months, after installation, and only valid for construction faults.

.3 Performance criteria: Operating humidity 75% Storage humidity 95% Operating temperature -0 C - +50 C Storage temperature -30 C - +70 C International standard IEC 62053-2 Accuracy class Protection against penetration of dust and water IP5 Insulating encased meter of protective class II.4 Specifications: Nominal voltage (Un) 230V AC Operational voltage 6-300V AC Insulation capabilities: - AC voltage withstand 2KV for minute - Impulse voltage withstand 6KV.2µS waveform Basic current (Ib) 5 A Maximum rated current (Imax) 30 A Operational current range 0.25A - 30A Over current withstand 900A for 0.0s Operational frequency range 50Hz ±0% Internal power consumption 2W / 0VA Test output flash rate (RED LED) 2000 impulses per kwh (0.5Wh/imp) Pulse output rate (pins 20 & 2) 2000 pulses per kwh (0.5Wh/imp) Power supply indicator (Green LED) Meter is connected and working OK Consumption indicator (RED LED) Flashing at load running.5 Basic errors: 0.05Ib Cosφ = ±.5% 0.Ib Cosφ = 0.5L ±.5% Cosφ = 0.8C ±.5% 0.Ib - Imax Cosφ = ±.0% 0.2Ib - Imax Cosφ = 0.5L ±.0% Cosφ = 0.8C ±.0%.6 Description A B C D E Register Case Terminal block Protection cover Security hasp

3 6 + - R 4 L 3 6 + - R 4 L N Material Register Case Terminal block Protection cover PC inflammable retarding PA inflammable retarding PA inflammable retarding PA inflammable retarding E C D ADMTE k Wh R L = 0.5 Wh/ imp RA= 0.5 Wh/imp A V,5(30)A, 60H z N00 B D 2 SO 20 RL= 0,5 Wh/imp RA= 0,5 Wh/imp (ti=80ms) SO Ui max = 27V / li max = 27mA ADMTE Single phase 30A kwh meter KEMA approved EN62053-2 DM Metering A B E C.7 Dimensions Height Width Depth Weight 6. mm 8. mm 58.5 mm 0.2 Kg (net) ADMTE kwh R L =0.5Wh/imp RA= 0.5 Wh/ imp 00V,5(3 0)A, 60H z 2 SO 20 RL= 0,5 W h/ imp RA= 0, 5 Wh /imp (ti=80ms) SO U i ma x = 2 7 V / li ma x = 2 7 ma KEMA approved EN62053-2 ADMTE Single phase30a kwh meter DMMetering

.8 Installation CAUTION Turn off and lock out all power supplying the energy meter and the equipment to which it is installed before working on it. Always use a properly rated voltage sensing device to confirm that power is off. WARNING Installation should be performed by qualified personnel familiar with applicable codes and regulations. Use isolated tools to install the meter. Fuse or thermal cut-off or single-pole circuit breaker can t be fitted on the supply line and not the neutral line. Case is sealed, failure to observe this instruction can result in damage for meter. - We recommend that the connecting wire which is used to connect meter to outside circuit should be sized according to local codes and regulations for the ampacity of the circuit breaker or over current device used in the circuit. - An external switch or a circuit-breaker should be installed on the inlet wire, which will be used as a disconnection device for the meter. And there it is recommended that the switch or circuit-breaker be near the meter so that it is more convenience for the operator. The switch or circuit-breaker should comply with the specifications of the building electrical design and all local regulations. - An external fuse or thermal cut-off which will be used as an over current protection device for the meter must be installed on the supply side wire, and it is recommended that the over current protection device be near the meter so that it is more convenience for the operator. The over current protection device should comply with the specifications of the building electrical design and all local regulations. - This meter can be installed indoor directly, or in a meter box which is waterproof outdoor, subject to local codes and regulations. - To prevent tampering, secure the meter with a padlock or a similar device. - The meter has to be installed against a wall which is fire resistant. - The meter has to be installed in a good ventilated and dry place. - The meter has to be installed in a protection box when placed in dangerous or dusty environment. - The meter can be installed and used after being tested and sealed with a letter press printing. - The meter can be installed on a 35mm DIN rail. - The meter should be installed in an available height so that it is easy to read. - When the meter is installed in an area with frequent surges due to e.q. thunderstorms, welding machines, inverters etc, protect the meter with Surge Protection Devices. - After finishing installation, the meter must be sealed to prevent tampering.

- Connection of the wires should be done in accordance with the underneath connection diagram. 3 6 20 2 S O + - 4 L N Inlet phase line 4 Inlet neutral line 3 Outgoing phase line 6 Outgoing neutral line 20 and 2 Pulse output contact.9 Operating. Working & consumption indication There is a LED which has two colors (green and red) in the front panel of ADMTE. When the meter works normally, this LED will constantly display green, if there is consumption the LED will flash red. The more quickly LED flash, the more consumption there is. For this LED, the flash rate is 2000 impulses per kwh (0.5Wh/imp). When meter is going wrong or no power supply, the LED will turn off. Reading the meter The ADMTE energy meter is equipped with a 6+ register which is used as recording consumption and can t be reset to zero. Six integers are marked with black color and one decimal is marked with red. The number system is based on units of 0. And unit is kwh. ADMTE kwh RL= 0.5 Wh/imp RA= 0.5 Wh/imp 00V,5(30)A,60Hz

Pulse output The ADMTE DIN rail energy meter is equipped with a pulse output which is fully separated from the inside circuit. That generates pulses in proportion to the measured energy for remote reading purposes and accuracy testing. The pulse output is a polarity dependant, passive transistor output requiring an external voltage source for correct operation. For this external voltage source, the voltage (Ui) should is 5-27V DC, and the maximum input current (Iimax) is 27mA DC. To connect the impulse output, connect 5-27V DC to connector 20 (anode), and the signal wire (S) to connector 2 (cathode). The meter pulses 2000 per kwh (0.5Wh/imp)..0 Troubleshooting CAUTION During repair and maintenance, do not touch the meter connecting clamps directly with your bare hands, with metal, blank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage. Turn off and lock out all power supplying the energy meter and the equipment to which it is installed before opening the protection cover to prevent the hazard of electric shock. WARNING Maintenance or repair should be performed by qualified personnel familiar with applicable codes and regulations. Use insulated tools to maintain or repair the meter. Make sure the protection cover is in place after maintenance or reparations Case is sealed, failure to observe this instruction can result in damage for meter. Problem Check Solution No light for the Power supply indicator. Is AC power supply connected to the meter? Check switch or circuit-breaker and fuse or thermal cut-off. Is the and 4 connecting correct? Maybe there is a fault in the inside circuit. Reinstall terminal screws on the and 4. Make sure all screws are fixed. Than there should be a 230V 50Hz AC voltage between the terminal screws on the and 4 when power supply is input. Please contact your technical supporter to replace this meter.

Continue. Problem Check Solution No light for the consumption indicator. Is the load running? Is the operating power too low? Only when load is running, this LED will flash. If the operating power is too low, the spacing interval of the flashes will take some more time this is why it seems that the LED isn t burning. The register can t run. No pulse output. Pulse output rate wrong. Maybe there is a fault in the inside circuit. Is there a power supply inside the meter? Is the operating power too low? Maybe there is a fault in the inside circuit. Is DC power supply connected to the meter? Is the connecting correct? Maybe there is a fault in the inside circuit. Maybe there is a fault in the inside circuit. Please connect with technical supporter to replace this meter. Check that the power supply indicator is burning. If the operating power is too low, the spacing interval of the pulses will take some more time this is why it seems that the register can t run. Please contact your technical supporter to replace this meter. Check the external voltage source (Ui) is 5-27V DC. Check correct connecting: connect 5-27V DC to connector 20 (anode), and the signal wire (S) to connector 2 (cathode). Please contact your technical supporter to replace this meter. Please contact your technical supporter to replace this meter.

. Technical support For questions about one of our products, please contact: - DMMetering dealer in your in your region - Your local DMMetering distributor - Email: support@dmmetering.com www.dmmetering.com Inepro Industries Ltd. Room 3208, Central Plaza 8 Harbour Road, Wan Chai Hong Kong Fax: +852 29 200 www.inepro.com.hk info@inepro.com.hk