SECTION 4 SANITARY SEWER SYSTEMS



Similar documents
3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

SANITARY SEWER SPECIFICATIONS

SECTION 3 SANITARY SEWER DESIGN

Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Chapter 9 Sanitary Sewers

CHAPTER 6 - SANITARY SEWER

SECTION POLYVINYL CHLORIDE (PVC) PIPE

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

Town House Center Highway North Huntingdon, PA 15642

SECTION 5: SANITARY SEWER SYSTEM DESIGN

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

CHAPTER 11 STORM DRAINAGE

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

Exhibit A. Rules and Regulations for House Connections and Sewer Extensions

CHAPTER 11 STORM DRAINAGE

SECTION 603 SANITARY SEWER FORCE MAINS

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

SECTION STORM DRAINAGE TABLE OF CONTENTS

Emerging Technologies in Wastewater Collection Systems

OAR52 A-1 (September, 1981)

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Utility Marking Trace Wire Guide

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

Florida Department of Environmental Protection

SECTION 812 SEWER LINE, MANHOLE AND WET WELL CLEANING

CITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 003 SANITARY SEWER COLLECTION SYSTEM

Specifications for Residential Property Owners Connection to New Public Sewer

Wastewater Capital Projects Management Standard Construction Specification

Customer Procedures and General Information for Sewer Customers

DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST

Wastewater Collection Practice Test #3 Page 1 of 15

CHAPTER 5. Storm Sewer

Section 2100-Trenching and Tunneling

SECTION IV - TESTS AND INSPECTIONS PART 1 - GENERAL Testing - General

OVERVIEW OF SIDE SEWER REQUIREMENTS

3.1 Introduction: Design Responsibility and Applicability of Requirements

APPENDIX D. (Standard Notes and Signature Blocks)

Section 5 Sanitary Sewer

SECTION ABANDONMENT OF SEWER MAINS

812-3 LIMITATIONS: b. No fire hydrant shall be obstructed or used when there is a fire in the area.

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

SEWER LINE EXTENSION DESIGN CHECKLIST

SECTION 5 DRAFTING STANDARDS

Sanitary Sewer Overflow (SSO) Incident Report Form

GUIDANCE DOCUMENT FOR SIZING AND INSTALLATION OF GREASE TRAPS AND INTERCEPTORS

Top 10+ Mistakes of DWV plumbing design

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Standards for Water, Sewer, and Sewage Lift Station Design

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS

LS 2540 SEWER LATERALS AND INSPECTION TEES

City of Bakersfield Public Works Department Sewer System Management Plan December 2014

SECTION 7 UNDERDRAIN SERVICE

FREQUENTLY ASKED QUESTIONS

Sewage Compliance Form Instructions

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

CHAPTER 6 SEWER SYSTEM DESIGN STANDARDS

foundation designed to keep water out of the basement.

SECTION 7- STORM SEWER

Chapter 7 Plumbing Connections

Standard Specifications For Private Sewer Laterals

SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD

CITY OF FARMERSVILLE, TEXAS

San Antonio Water System Standard Specifications for Construction ITEM 866 SEWER MAIN TELEVISION INSPECTION

CHAPTER 8 CIVIL DESIGN

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

Section 3510: Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011

City of Regina Standard Construction Specification SECTION 1320 SEWERMAIN TESTING

PLUMBING ROUGH IN INSPECTION

CITY OF ST. CA THARINE S. cn- Olc.4 BY-LAW NO. WHEREAS the Council of the Corporation of the City of St. Catharines, is

Monterey Regional Water Pollution Control Agency. Sewer System Management Plan

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

TABLE OF CONTENTS. Manhole, Frame, and Cover Installation (includes Drop Manhole) Additional Manhole Depth

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

SANITARY SEWER SYSTEM ASSESSMENT

Sewer Line Rehabilitation

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

STANDARD SPECIFICATIONS SECTION INSTALLATION OF GRAVITY SEWER PIPELINES. 1. Trenching, Backfilling and Compacting: 02223

CITY OF ANN ARBOR PUBLIC SERVICES PLAN REVIEW CHECKLIST

Jay R. Smith Mfg. Co.

SECTION FACILITY STORM DRAINAGE PIPING

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

Close-Out Documents... 9

SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

WATER SERVICE 2

SANITARY SEWER BACKUP. Causes & Prevention

SECTION SANITARY SEWER PIPE

CITY OF BEVERLY RULES AND REGULATIONS - SEWER SYSTEM TESTING. General

Plugging Home Drains to Prevent Sewage Backup

Transcription:

SECTION 4 SANITARY SEWER SYSTEMS 4.1 General Requirements. Sanitary sewer systems shall be designed, constmcted, and tested in accordance with the current editions of the Montana Department of Environmental Quality Circulars, the Montana Public Works Standard Specifications and the City of Whitefish Engineering Standards. All sewers shall be designed as a gravity sewer whenever physically feasible. Standard Details 31-36 are the sanitary sewer details that must be included, where applicable, in sewer system constmction drawings. The following shall apply to the design of all sanitary sewers: Design Report - Gravity Sewers. Unless waived by the City Engineer, the Design Engineer shall submit a written report for all sanitary sewer extensions. The design report shall demonstrate that all sanitary sewer extensions have adequate capacity to convey wastewater from the anticipated service area and meet the minimum flow velocities and/or flow depth requirements in Chapter 30 ofmdeq Circular-2. The report shall also assess the impact on the Wastewater Treatment Plant. Dead End Sewer Mains. Avoid dead end sewer mains with few (<4) services and no potential for future extension. Avoid locating manholes outside of roadway right-of-ways. Quality of Sewage. No development shall introduce any sewage into the City of Whitefish sewerage facility that is not consistent with normal domestic sewage. The sewage must arrive at the Wastewater Treatment Plant in a non-septic condition. No storm water shall discharge to any sanitary sewer. Velocity. The minimum velocity, in either gravity or force mains, shall be two (2) feet per second, based on a flowing full condition on gravity mains. The maximum velocity shall be ten ( 1 0) feet per second, unless otherwise approved by the City. Minimum Depth. Sanitary sewers shall be buried to a depth sufficient to prevent freezing and shall have a minimum four (4) feet of cover. Shallower depths may be allowed by the Public Works Department if suitable pipe insulating provisions have been made. Accessibility. Sewer mains shall be installed in public right-of-way wherever possible. All sewer facilities shall be designed and constmcted so that all such facilities are readily accessible for maintenance and repair. Where mains cannot be installed in the ROW, a 20-foot wide easement shall be provided with the pipe centerline five (5) feet from one easement edge. Section 4-1

Manhole Spacing. The maximum spacing between manholes shall be 400 feet for sewer main at slopes of 0.4% - 4%, 300 feet for sewer main at slopes of 4% - 8%, and 200 feet at slopes greater than 8%. Service Line Separation. A minimum of 1 0' horizontal separation must be provided between sewer and water service lines. Garage Floor Drains. No direct connection of garage floor drains shall be allowed to the sanitary sewer service line. Force Main Cleanouts. Pressure type cleanouts, of the same size as the force main, shall be provided at approximate 600 foot intervals along a force main unless approved by the City Engineer. A removable cap for the force main cleanout shall also be tapped for and fitted with a one (1) inch threaded plug. The force main shall be equipped with a plug valve and valve box immediately upstream of each force main cleanout. Sewer Hookup Requirement. Sewer hookup is required for new construction if the proposed building is within 500 feet of a property served by sewer or within 500 feet of a City sewer main. 4.2 Material Specifications. Pipe Size. Sewer mains shall be sized for the ultimate development of the tributary area. Nothing shall preclude the City from requiring the installation of a larger sized main if the City determines a larger size is needed to meet the requirements for future service. Joint participation by the City may be applicable where oversizing is deemed appropriate by the City Engineer. The minimum diameter of any gravity sanitary sewer main shall be eight (8) inches. Gravity Sewer Main. Gravity sewer main material shall be PVC SDR 35. Pressure Sewer Main. Pressure sewer main (force mains) shall consist ofhdpe SDR 11 or approved equal with butt fusion joints. Gravity Sewer Service Pipe. Gravity sewer service pipe shall be schedule 40 PVC. The terminal end of sanitary sewer services at undeveloped lots shall be marked in accordance with Standard Detail 31. Pressurized Sewer Service. Pressurized sewer service pipe shall be HDPE SDR1 1 or approved equal. Sanitary Sewer Service Lines. Structures containing two or more residences under separate ownership, such as townhouses or condominiums, shall have separate sewer service lines for each residence. Structures containing two or more residences, offices or Section 4-2

businesses that are rental units under common ownership may have one service line for all occupants within a single structure subject to approval by the City. Sanitary Sewer Manholes. All sanitary sewer manholes shall be constructed and installed as specified by the Montana Public Works Standard Specifications. In addition, all sanitary sewer manholes sections shall be sealed with an exterior rubberized joint seal meeting ASTM C-877, type II with a minimum width of nine (9) inches. (See Standard Details 32a & 32b). Avoid locating manholes outside of road right-of-ways. Avoid dead end sewer mains with few services and no potential for future extensions. Sewer Saddle. Sewer saddles shall be Romac Saddle: CB-4.63 U.N (for any main type) or PVC Saddle: 0-ring/gasket seal w/stainless steel clamps (PVC main only). Gravity Main Cleanouts. Gravity main cleanouts shall not be permitted unless the Engineer shows that conditions exist as described in the MDEQ Circular 2, 34.1 (allowing cleanouts in special situations and at the end of mains less than 150 feet in length with no services installed and available for future extension). Sanitary Sewer Manhole Ring and Cover. The sanitary sewer manhole ring and cover shall be East Jordan Iron Works Model 3772Z1, or approved equal. The cover shall be marked Sewer. Manholes located within the paved sections of roadways or driveways or in areas subject to flooding shall have approved infiltration pans installed. Adjustment Rings. All adjustment rings shall only be composed of concrete or high density polyethylene (HDPE). No rocks, asphalt, wood shims or any foreign material shall be used to adjust rings. No more than two (2) adjustment rings shall be used per each manhole grate. Combinations of adjustment rings shall have a total height of more than two (2) inches and less than ten (10) inches. All grate and adjustment ring combinations shall be sealed with a rubberized chimney seal meeting the specifications of ASTM C-923 and shall have of a minimum thickness of 3116 inches. Warning Tape for Force Mains. Detectable warning tape shall be a minimum of 5 mils thick, three inches wide and conform to APW A colors. Toner Wire for Force Mains. All force mains shall be laid with 12 gauge insulated solid core copper toner wire. Toner wire shall be insulated and taped to the top of the force main. Splices of toner wire shall be made with heat shrink tape. Testing. Testing of the manholes, sewer lines or force mains must be done in accordance with the Montana Depatiment of Environmental Quality Circulars and the Montana Public Works Standard Specifications. Section 4-3

Dog house Manholes. Dog house type manholes are not allowed when connecting to an existing sewer main unless approved by the Public Works Director. Television Inspection. Prior to the City's acceptance of the sewer system the Contractor must provide television inspection of the system. The cost of television inspection will be the responsibility of the Contractor. If any deficiencies are found during the inspection, the Contractor shall correct them at the contractor's expense. Oil/Water Separators. Automotive repair facilities and paint shops, dealerships, gas stations, equipment degreasing areas, and other facilities generating wastewater with oil and grease content are required to pretreat these wastes before discharging to the City sanitary sewer system. Pretreatment requires that an oil/water separator be installed and maintained on site. Oil/water separators for commercial/industrial processes must be sized on a case-by-case analysis of wastewater characteristics. Typically a minimum capacity of750 gallons is required for small gas stations, auto repairs, and light commercial sites; 1500 gallon capacity for large-scale truck washing and steam cleaning facilities. The ultimate discharge must be directed to the sanitary sewer system. All units regardless of size shall be fitted with a standard final-stage sample box and spillabsorbent pillows. Oil/water separators shall be commercially manufactured and sized for the intended discharge rates for the facility where it is to be installed. 4.3 Sewage Lift Station Impacts. A written report shall be submitted for any project that will create a new sewage lift station or will contribute to an existing sewage lift station. The report for a new sewage lift station shall contain, but not be limited to, the following: -a description of the proposed wet well, pumping system, and force main. -the capacity of the recommended pumps and potential for future upgrades. -a map showing the potential lift station service area. -the average and peak design flows for the proposed project and for the potential service area. -the hydraulic capacity ofthe force main. -the reserve capacity of the lift station when the proposed project is on line at full capacity (full build out). -the pump run and cycle times for the average and peak design flows. -strategies for improvements which may be necessary to accommodate future sewer extensions. (i.e., increased storage, pumping or auxiliary power capacity) -a statement of the pump selection process, including the Engineer's calculations for the total dynamic head, total discharge head, net positive suction head, and other pertinent pump selection criteria. -the designed pump operating curve plotted on a manufacturer's pump performance chart with the designed operating point clearly identified. Section 4-4

The report for a project that will contribute to an existing sewage lift station shall contain, but not be limited to, the following: -a description of the existing wet well, pumping system and force main. -the capacity of the existing pumps and potential forfuture upgrades. -a map showing the potential lift station service area. -a list of the existing users and their average design flows. -the existing peak design flow and reserve capacity. -the pump run and cycle times for the existing average and peak design flows. -the hydraulic capacity of the force main. -the proposed average and peak design flows to the lift station. -the reserve capacity of the lift station with the proposed proj ect on line at full capacity. -the pump run and cycle times for the proposed average and peak design flows. -recommendations for improvements, if necessary, to enable the lift station to serve the proposed project. An emergency power supply will be required for all lift stations unless approved by the Public Works Director. Upon request from the Director of Public Works/City Engineer, the Design Engineer shall submit a list of three lift stations of the type proposed which have been in operation at least five years. The City reserves the right to accept or reject the proposed lift station. An alarm system shall be provided that is capable of detecting power interruption, phase loss, low water, motor failure, seal failure (motor moisture sensor), high water, and high motor temperature conditions. The alarm signals shall be directed to an on site alarm monitoring and telephone dialer system. The alarm monitoring and telephone dialer system shall be a 1400 Sensaphone or approved equal. An hour meter is required on each pump. Amperage meters are required on each leg of the electrical wiring. Surge/Lighting protection is required on all control panels. Cathodic protection is required for all lift stations having a metallic exterior. The Engineer shall submit an analysis of the amount of cathodic protection required. Section 4-5