Generator Quick-Connect Double-Throw Safety Switch. Product Focus



Similar documents
Giving You the Power to Stand Alone

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Reverse-feed applications for circuit breakers

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Nothing s BetterThan the Original MODAN Power Distribution Systems

Generator DoCKInG StatIonS

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Mission Critical Data Center Systems

PowerChain Management solutions. PowerChain Management Solutions for Data Centers

Bypass transfer switch mechanisms

Electrical Grounding. Appendix C

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Eaton s backup power systems. Mother nature strikes when you re least expecting it. Let Eaton be the solution for your backup power needs.

Continuous Power... Continuous Protection

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Product Guide. Low voltage grounding system. Answers for industry.

Fundamentals of Power

Distributing Power to Blade Servers

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

CONTINGENCY PLANNING FOR DISRUPTED ELECTRIC POWER: The Case for Partnering with a Strong Rental Power Supplier

Mike Holt s Illustrated Guide to. Rule , Articles 445, 700, 701, and 702. Based on the 2011 NEC

Comparison of NEMA and IEC schematic diagrams

Engineering innovation

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

ATC-300 Automatic Transfer Switch Controller

Emergency, Standby and Backup Power Connection Solutions

Top Commercial / Residential Electrical Requirements *

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

ELECTRICAL INSPECTION BULLETIN (Effective )

Installation and Operation Guide for PD4000 Series Power Control Center

How To Test A Power Switch On A Power Supply

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

The Interaction of Contactors with PLCs

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Secondary Unit Substations

Distributed versus centralized power backup strategies

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

For Models #6-5001, #6-7501, # & #10-12K1

Increased power protection with parallel UPS configurations

Data Center Trend: Distributed Power in the White Space

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

Harmonics in your electrical system

Installation Instructions

ASCO SERIES 185 Power Transfer Switches

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system

Contingency Planning Minimizing risk when the unexpected happens

Overcoming Eight Common Power Management Challenges

Effective July 2015 Supersedes April Reliability Selective coordination Inherent fuse reliability... 4

Electrical Design TABLE OF CONTENTS FOREWORD BASIC ELEMENTS OF ELECTRICITY... 2 Electricity works much like water Ohm s Law

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Innovative Naples Generator Design Replaces Large Units in Temporary Power Restoration Following Hurricane Wilma. Introduction

Eaton s E-Series protective relay family

Corner-Grounded Delta (Grounded B Phase) Systems

Maximizing UPS Availability

Applications. Remote Display Mounting Kits

Storm Ready. 3 Gulf Power Ready for the storm. 4 Be prepared, be safe. 5 Getting the lights back on. 6 Damage to your home s service connection

CONDUCTOR SHORT-CIRCUIT PROTECTION

Extend the Life of Existing Switchgear

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Powering Converged Infrastructures

Ontario Electrical Safety Code 25 th Edition/ 2012

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Understand Hybrid Generator Battery Systems

Smart House And Home Automation Technologies

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

GLOLAB Two Wire Stepper Motor Positioner

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Alternating Phase Power Distribution at the Data Center Rack PDU

Server Technology Inc.

ELECTRIC SERVICE HANDBOOK General Information Residential Service Portable/Standby Generators Temporary Service Commercial Service Metering

CURRENT TRANSFORMERS INSTALLATION GUIDE

Mining service breakers with true rms sensing designed specifically for trailing cable applications

Current Transformers

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

Construction Electrical Terminology. Electricians

The Starting System. Section 4. Starting System Overview. Starter. The starting system:

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

HM-W536 Install Guide

Generator Transfer Switch Model # HTS15-AUTO

Frequently Asked Questions Generators

Siemens STEP 2000 Course Basics of Electrical Products

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

MOBILE DC POWER SYSTEMS FOR SUBSTATION APPLICATIONS

POWERING THE WAY Rental Power Planner

Arc Fault Circuit Interrupters Frequently Asked Questions

Evaluating Water-Damaged Electrical Equipment

Short Circuit Current Calculations

ELECTRIC SCHEDULE LS-2 Sheet 1 CUSTOMER-OWNED STREET AND HIGHWAY LIGHTING

Transcription:

Generator Quick-Connect Double-Throw Safety Switch Product Focus

Backup Power Solutions for Commercial Facilities The Power is Out! Blackouts. Hurricanes. Thunderstorms. Snow. Ice storms. Floods. High winds. Whether they are caused by a utility power interruption or weather disasters, power outages are frequent occurrences throughout the country. If you are responsible for maintaining commercial facilities, power reliability is likely to be a real concern. Whether you want to maintain uptime, or are worried about losing perishable inventory, chances are the thought of power reliability has crossed your mind recently maybe even causing you a few sleepless nights. Making the decision to provide backup power capability to your facilities is the first step, and has probably raised many questions: Do you need standby systems that automatically start when there is an outage, or will you use portable units? What size generator is suitable for your needs? How do you safely connect a portable generator to the store s electrical system? If you have decided to use portable units, will you own the generators, or rent them as needed? These are just a few of the questions that need to be answered in order to meet your unique power needs. If the decision has been made to use portable generators rather than investing in permanently installed standby units, this product guide will assist you in the critical step of preparing your facilities to be able to quickly connect the generators once they arrive at the site. Like the utility power lines that enter the facility, the portable generator will need a point of connection. The time to think about how that connection will be made is now before the power is out. Also, a plan needs to be in place that considers your customers and employees safety, yet allows for a quick connection of the generator to your facility to get the facility powered up with a minimal amount of downtime. Installing a Cutler-Hammer Quick-Connect Double-Throw Switch as your utility service disconnecting means up front provides both a quick means of generator connection, and a safe way to transfer power from a normal power source to the backup power source. Step 1 Determine the requirements for Main Service Disconnect A facility will generally have one utility service disconnect. This disconnect may be inside or outside, but it will be the first device after the utility meter. Cutler-Hammer Double-Throw Switches are available up to 800 amperes. If the service for your facility is larger than 800 amperes, another solution from Eaton is required. Generally, a fusible device is preferred first to provide overcurrent protection, and second because fusible devices have a higher fault current rating than non-fused switches. Step 2 Determine the generator size in kilowatts (kw) that will meet your requirements While some facility managers may desire to run the entire operation under generator power, it is not a requirement to do so. You may choose to run only a critical portion of your facility during a power outage. The important component in the decision is whether you want to keep the whole facility operating as it would with utility-supplied power. The chart on page 3 is an analysis of the output current of various sizes of generators at different voltages. If the desire is to run the entire facility, the generator required is the one that provides a current rating equal to the ampacity of your Main Service Disconnect at the facility s utilization voltage. For example, a 600 ampere 208 volt three-phase building would best be served by using a 175 kw generator. Step 3 Determine whether the backup generators will be owned or rented If the units will be rented, it will be helpful to make contact with a generator rental company to see what form of agreement is required to guarantee the delivery of the generator to the facility in a timely manner. The rental company will help 2 EATON CORPORATION Generator Quick-Connect Double-Throw Safety Switch Backup Power Solutions for Commercial Facilities

MAXIMUM GENERATOR CURRENT OUTPUT AND SWITCH SIZING CHART Three-Phase Single-Phase (80% Power Factor) (Unity Power Factor) 208 Volt 480 Volt 240 Volt Non- Non- NonkW Amps Fusible Fusible Amps Fusible Fusible Amps Fusible Fusible 2 2 2 5 17 30 30 8 30 30 21 30 30 7.5 26 60 30 11 30 30 31 60 60 10 35 60 60 15 30 30 42 60 60 12 42 60 60 18 30 30 50 100 60 15 52 100 60 23 30 30 63 100 100 20 69 100 100 30 60 30 83 200 100 25 87 200 100 38 60 60 104 200 200 30 104 200 200 45 60 60 125 200 200 40 139 200 200 60 100 60 167 400 200 50 173 400 200 75 100 100 208 400 400 60 208 400 400 90 200 100 250 400 400 75 260 400 400 113 200 200 313 400 400 80 278 400 400 120 200 200 333 600 400 100 347 600 400 150 200 200 417 600 600 125 434 600 600 188 400 200 521 800 600 150 520 800 600 226 400 400 625 800 800 175 607 800 800 263 400 400 729 x 1 800 200 694 x 1 800 301 400 400 250 x 1 x 1 x 1 376 600 400 300 x 1 x 1 x 1 451 600 600 350 x 1 x 1 x 1 526 800 600 400 x 1 x 1 x 1 601 800 800 500 x 1 x 1 x 1 752 x 1 800 1 x indicates an ampacity that exceeds the capability of the Quick-Connect Double-Throw Switches. If your facility falls outside the scope of the Quick-Connect Switch capacity, talk with an Eaton representative about other options available. 2 Non-fusible devices are rated at 10 kaic maximum unless protected by an upstream fuse. determine the right size generator to meet the needed requirements, and may make a site visit to analyze the location and any potential connection issues. One point of discussion should be which party will provide the cables to connect the generator to the facility. If the rental company is going to provide the wires to connect, it is important to determine what type of quick-connect device they can provide to plug into the facility s electrical system. Cutler-Hammer Quick-Connect Double-Throw Switches are available with Cam-Lok, Posi- Lok and pin-and-sleeve devices from various manufacturers including Crouse-Hinds, Appleton, Meltric, Russellstoll and others. Since these devices are not generally interchangeable, it is important that the plug and receptacle are compatible. If the generators will be purchased, Eaton can help guide you through the decision of selecting the appropriate connector for your needs. Step 4 Configure a Quick-Connect Double- Throw Switch Call the Flex Center at Eaton s Cleveland, Tennessee manufacturing plant for assistance in designing a suitable switch for the application. A double-throw switch is a manual device that consists of two interlocked switches that cannot be "ON" at the same time. The switches are vertically oriented with the upper switch being the "NORMAL" switch, and the lower switch being the "BACKUP POWER" switch. For Quick-Connect Double- Throw Switches, Flex Center technicians connect wires from the line side of the "BACKUP POWER" switch to a power inlet receptacle. This allows a generator to be plugged into the switch via a receptacle rather than opening the switch, and hard wiring cables directly to the lugs. The receptacle can be a pin-and-sleeve device that connects all wires simultaneously, or it can be an individual receptacle such as a Cam-Lok or Posi-Lok that connects each wire individually. There are benefits and drawbacks to using each of these devices. Pin-and-sleeve devices ensure that all cables are connected since they are inserted simultaneously. However, since all of the cables are bundled together, the weight of the connection cable can become unwieldy at higher amperages. The Meltric pin-and-sleeve device has the added benefit of being able to be connected and disconnected while energized. This is a safety feature in the event that the receptacle is inserted or removed without opening the switch and/or turning off the generator. The Cam-Lok and Posi-Lok devices are single-pole connectors that connect each wire separately. The result is that the multiple phase, neutral and ground wires are unbundled and connected individually which breaks the connecting cables into more manageable weights. This allows for longer runs from the generator, and is also ideal for higher ampacities (400 amperes and higher). The difference between the Cam-Lok and Posi-Lok devices is that Posi-Lok panels require the wires to be connected in proper electrical sequence. Specifically, the ground wire must be connected prior to connecting the neutral wire, and the neutral wire must be connected prior to the phase A conductor and so on. Likewise, the wires must be disconnected in proper reverse order. This added level of safety ensures proper grounding connection of the system, which can prevent electrical shock. With both of these devices, however, the system can be energized without having all conductors connected risking potential damage to equipment, and therefore should be connected only by trained electrical professionals. The Flex Center staff will guide you through this process, and will assist in configuring the required Quick-Connect Switch. You will be asked for the ampacity of the switch, the voltage system employed at the facility, as well as the type of generator connection that is desired. The Flex Center staff has over 120 years of design, manufacturing and industry experience, and has been providing customer switching device solutions since 1988. Call the Flex Center today at 1-888-329-9272. EATON CORPORATION Generator Quick-Connect Double-Throw Safety Switch Backup Power Solutions for Commercial Facilities 3

1. 800 Ampere Double-Throw With Posi-Lok panels to Quick-Connect a 150 kw generator. 2. 60 Ampere Quick-Connect Double-Throw With interlocked pin-and-sleeve receptacle. 3. and 4. Cutler-Hammer Quick- Connect Double-Throw Switches streamline installation for a neat, clean appearance. 5. Posi-Lok Panels This detail shows one ground receptacle open note that a plug would need to be installed to open the next door. 1 2 3 4 5 EATON CORPORATION Generator Quick-Connect Double-Throw Safety Switch Backup Power Solutions for Commercial Facilities 4

Eaton s electrical business is a global leader in electrical control, power distribution, and industrial automation products and services. Through advanced product development, worldclass manufacturing methods, and global engineering services and support, Eaton s electrical business provides customerdriven solutions under brand names such as Cutler-Hammer, Powerware, Durant, Heinemann, Holec and MEM, which globally serve the changing needs of the industrial, utility, light commercial, residential, and OEM markets. For more information, visit www.eatonelectrical.com. Eaton Corporation is a diversified industrial manufacturer with 2005 sales of $11.1 billion. Eaton is a global leader in electrical systems and components for power quality, distribution and control; fluid power systems and services for industrial, mobile and aircraft equipment; intelligent truck drivetrain systems for safety and fuel economy; and automotive engine air management systems, powertrain solutions and specialty controls for performance, fuel economy and safety. Eaton has 59,000 employees and sells products to customers in more than 125 countries. For more information, visit www.eaton.com Eaton Electrical Inc. 1000 Cherrington Parkway Moon Township, PA 15108 United States tel: 1-800-525-2000 www.eatonelectrical.com Appleton is a registered trademark of Appleton Electric. Crouse-Hinds, Posi-Lok and Cam-Lok are federally registered trademarks of Cooper Industries. Cutler-Hammer is a federally registered trademark of Eaton Corporation. Russellstoll is a registered trademark of Thomas & Betts Corporation. 2006 Eaton Corporation All Rights Reserved Printed in USA Publication No. BR00801003E / Z3929 February 2006