SYSTEMS AND PARTS EARTHING CONTROL: TES-01. Background. Product. Functioning SYSTEMS AND PARTS - EARTHING CONTROL



Similar documents
Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Operating Instructions

Technical Data. Dimensions

Plug and Socket Devices CES 63 A Series 8579

Series 8146/5-V37 and Series 8150/5-V37

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Inductive sensor NI10-M18-Y1X-H1141

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Plug and Socket Devices SolConeX 16 A Series 8570

SEISMIC VELOCITY TRANSDUCER T1-40

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Explosion proof enclosures

Technical Data. Dimensions

2.12. page Products for Explosion hazardous Environment

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Compact pressure switch Flameproof enclosure Ex d Model PCA

Terminal Boxes Series 8146

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Floodlight Range Installation Guide

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Box. Specifications TNCN

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Technical Specifications

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Control- and feedback head for integrated mounting on Robolux valves Type 2036

7 Lighting Technology

Flameproof Audible Signal 115 db (A) Series YA90

Instructions for Safe Use

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Software and Display instruments

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Inductive slot sensor

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

S300 Series Dust Monitors

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Control and Distribution Boxes made of Stainless Steel Series 8150

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Electric Rotary Actuator - On/Off or programmable control actuator

TEIP11 I/P signal converter for standard signals. Measurement made easy

Solenoid Valve Island Type 3965

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

TIG INVERTER INSTRUCTION MANUAL

Manual. Solar Fountain Mobile Phone Charger

Technical Information RIA14

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

3DLevelScanner II TECHNICAL DATA SHEET

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Brochure EX

Thermometer in stainless steel with capillary and switch contacts

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

2 & 5-Wire Overfill Sensors

Shunt lock function 3066

CUSTOMS UNION. CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В Series RU No

Wanner International and ATEX Directive 94/9/EC Covers - Category 2 Zone 1 and Category 3 Zone 2 requirements

SURGE PROTECTIVE DEVICES

3500/93 System Display

ACTIV-8 PLUS Insulated Conductor Bar

3/2-way Solenoid Valve, direct-acting, NC or NO

Electronic, Digital and Mechanical Vibration Switches

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Relative pressure transmitter type 520

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Scraper Passage Indicator. Electrical Indicator. Features

CAPACITIVE LEVEL METERS CLM 36

A good connection. International approvals.

OPTIMASS 1400 Technical Datasheet

How To Read A Pipe From A Sensor

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Wolflite Safety Handlamp H-251E

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

CB Zone Conventional Control Panel

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Brochure. Light fittings, floodlights and beacons New LED range for hazardous areas

Transcription:

Background When combustible products are loaded/off-loaded from a tanker truck there is a risk of an explosion occurring due to ignition caused by a static discharge from the truck itself. To prevent this occurring the truck must be connected to earth and fully discharged before loading can proceed. Product EX version Truck Earthing system TES-01 Advantages Safe discharge of electrostatic charge Measurement of the resistance seen at the clamp Verification that the capacitance is correct for a tanker truck. Red/green indicators for visual status indication of the earth connection Interlock to conveying system via a volt-free contact Bypass of the capacitance mode for operation in extreme wet conditions. Suitable for 240VAC and 24VDC power supply systems. To ensure that loading cannot take place without the truck being earthed, a monitoring system is required to ensure that a good connection has been made to the truck by means of a clamp, the earth monitor will then allow the conveying process to be started by means of a relay. For an earth monitoring system to be effective it must be able to distinguish between a connection to a truck and any other metallic body such as ductwork, girders, cable trays etc. In order to make the distinction, the Truck earthing System TES-01 measures the capacitance of the metal body connected to the clamp, it checks whether the capacitance is correct for a truck, and finally provides both visual indication and the closing of a relay contact when the capacitance is correct. Functioning The Truck Earthing System TES-01 is designed to detect a low resistance connection across the jaws of the clamp. When a connection is detected the unit safely discharges any electrostatic charge through a resistor to prevent sparking. The control unit then checks the capacitance seen at the clamp. If the capacitance is correct for a tanker truck then the green indicator will be lit and the interlock relay will change state to allow conveying of the product. The unit will then provide a low-resistance connection to earth to prevent the further build-up of electrostatic charge. The connection across the jaws is the continually monitored during the conveying process. If the connection is broken the unit will switch back to the RED NOT-CONNECTED state and conveying will be halted by means of the interlock relay. IP version with CM1 clamp, clamp station and spiral cable Cable reel DS_S&P-TES01_SI_13_01_EN

System description Active clamp CL1 Active clamp CM1 The basic system consists of a control unit, an earth clamp and a cable (as an option a cable reel is also available). The earth clamp is active ' With active clamps, both clamp jaws are insulated from each other and from the clamp body. As long as the clamp is not connected to a conductive body, the circuit between the clamp jaws stays open. Once the clamp is connected, the circuit is closed. The cable reel The cable reel is equipped with cable and an automatic roll-up mechanism. Intended use The control unit, the intrinsically safe measuring circuit and that circuit s components (clamp, plug connection and cable reel) are ATEX certified. Depending on the type, the system can be set up in Ex zones 1, 2, 21, 22 or in an industrial environment IP 65. Clamp station Clamp hook Technical specifications For more details on this product, we refer to the technical datasheet. StuvEx retains the right to make changes without prior notice

Application Characteristics TES-01 Specific use for Tanker Trucks on tyres Recognition Functioning Capacitive In addition to low resistance R, the truck s capacitance C is measured With proper earthing the control unit is triggered (the green signalling lamp lights and the potential free contact for interface change state) Power supply 110-240 VAC +10% / -15% - 50/60 Hz, auto-ranging Or 24 VDC +20% % / -20% Consumption: max 20W Ambient temp module -20 C to + 60 C Ambient temp unit -10 C to + 40 C Humidity level 95% at 20 C (non condensing) Remote signalling Volt free contact 8A at 250VAC / 30VDC, NO IP version Signalling lamps Operating Guaranty ATEX Certification Red light: no earth connection Green light: correct earth connection SIL2 / report Technis Reliability Study T533 The measurement and earth connection circuit is intrinsically safe EEx I and suitable for use in ATEX zone 0 and 20 Versions Type TES-01 / Ex TES-01 / IP ATEX For Ex zones 1, 2 (gas) For Ex zone 22 (dust) 21 and 22 (dust) and non hazardous areas CE Ex II 2(1) GD Ex d [ia Ga] IIC T6 Gb Ex tb [ia Da] IIIC T85C Db IP66 CE Ex II 2 (1)D Ex tb [ia Da] IIIC T135 C Material Cast aluminium Painted mild steel with stainless steel front plate Finish Grey coloured coating painted, RAL 7035 Dimensions 230 h x 230 w x 150 d 300 h x 200 w x 150 d Weight 10 Kg 5 Kg Connections 4 pieces M20 x 1 3 pieces for M20 Bypass Optional Integrated Protection degree IP 66 IP 66 EX version DS_S&P-TES01_SI_13_01_EN

Active clamp CL1 Active clamp CM1 Clamp station Clamp hook StuvEx retains the right to make changes without prior notice Type CL 1 Type CM 1 Accessories Earth connection clamps Description Large size: 260 mm, aluminium Jaw opening: min 3, max 15 mm. Medium size: 210 mm, stainless steel Jaw opening: min 3, max 35 mm Accessories Delivered with loose plug connection ATEX Passive EEx i component for Ex zone 0, 20 II 1GD Ex c, ia IIC, IIIC T6 T85 C Clamp Station / Clamp Hook Material Casing in RVS 304 Support: acetal Weight 0,20kg Type SP1/10 10m Spiral cable Application For extreme industrial environments For industrial use Cable on reel Type CR 1 / 65 Closed cable housing in aluminium, pivotable on bracket. Shock and weather resistant Spring activated automatic winding, with blocking mechanism Degree of protection IP 65 Weight 12 Kg Cable 24 meters H05RN-F2 x 1.5 + 1.5 mm² ATEX Passive EEx i component and mechanical equipment for Ex zone 1, 21 II 2GD Ex c, ia IIC, IIIC T6 T85 C Type CO 01 / 10 Cable without reel 10 meters H05RN-F2 x 1.5 + 1.5 mm²

Part number Main Components Product Description 502-4010-000 TES-01/IP, Control Unit 501-4010-000 TES-01/EX, Control Unit 503-1100-008 CL1, active clamp 503-1050-003 CM1, active clamp 503-5910-100 Spiral cable, 10m, SP1/10 503-5900-100 CO1/10, 10m flying cable (without cable reel) 503-3250-008 CR1/65, Cable reel with 24m cable (optional) 641-1100-020 Remote key switch for TES-01/EX (optional) 503-0900-003 Clamp station (optional) 503-0900-103 Clamp hook (optional) Unit version Ex Cable Reel Unit version IP All dimensions are in mm