Standardization of three-dimensional images in obstetrics and gynecology: consensus statement



Similar documents
An introduction to fetal neurosonography using three-dimensional ultrasound

Three-dimensional Ultrasound Imaging

3D Ultrasound. Outline. What is 3D US? Volume Sonography. 3D Ultrasound in Obstetrics: Current Modalities & Future Potential. Alfred Abuhamad, M.D.

Three-Dimensional Inversion Rendering

Three-Dimensional Sonography of the Endometrium and Adjacent Myometrium

School of Diagnostic Medical Sonography Course Catalog

Ultrasonographic Determination of Equine Fetal Gender (31 Mar 2000)

School of Diagnostic Medical Sonography Course Catalog

Beverly E Hashimoto, M.D. Virginia Mason Medical Center, Seattle, WA

Department of Obstetrics and Gynecology, Eastern Virginia Medical School, Norfolk, United States

High-definition 3D Image Processing Technology for Ultrasound Diagnostic Scanners

The Practical Application and Clinical Use of Modern 3D Ultrasound Technology in Gynaecology

Eastern Mediterranean Health Journal, Vol. 10, No. 3,

GE Healthcare. Vivid 7 Dimension Cardiovascular Ultrasound System

Information for you A low-lying placenta (placenta praevia) after 20 weeks

Introduction. I. Objectives. II. Introduction. A. To become familiar with the terms of direction and location.

Charts of fetal size: limb bones

3D in Gynecology: Luxury or necessity?

The value of ultrasound in the prediction of successful induction of labor

Imaging of placental vasculature using three-dimensional ultrasound and color power Doppler: a preliminary study

Twelve. Figure 12.1: 3D Curved MPR Viewer Window

Welcome to Anatomy & Physiology

3D Viewer. user's manual _2

Breast Sonography general goal. Optimizing Breast Sonography. BUS indications -- all. Breast Sonography specific goals.

School of Diagnostic Medical Sonography

Frontomaxillary and mandibulomaxillary facial angles at to13+ 6 weeks in fetuses with trisomy 18

Body Planes & Directions Anatomic Reference Systems (Unit 6, pp )

Ovarian Torsion: Sonographic Evaluation

National Medical Policy

INTERGROWTH-21 st International Fetal and Newborn Growth Standards for the 21 st Century

Three-dimensional ultrasound in the diagnosis of Müllerian duct anomalies and concordance with magnetic resonance imaging

Reference intervals of gestational sac, yolk sac and embryo volumes using three-dimensional ultrasound

ASSESSMENT REPORT. Program: AAS Diagnostic Medical Sonography Cardiac Vascular Tract

Diagnostic Medical Sonography

Three Dimensional Ultrasound Imaging

INFORMATION SOCIETIES TECHNOLOGY (IST) PROGRAMME

Occupational Therapy Manual for Evaluation of Range of Motion and Muscle Strength

A Three-Dimensional Correlation Method for Registration of Medical Images in Radiology

The following chapter is called The Role of Endoscopy, Laparoscopy, and Hysteroscopy in Infertility.

ROTATIONAL POSITIONING

DICOM Correction Item

Three-Dimensional Endovaginal Sonography of Synthetic Implanted Materials in the Female Pelvic Floor

How To Use A Voluson Compact Ultrasound System

Fetal size and dating: charts recommended for clinical obstetric practice

GE Healthcare VOLUSON 730 PRO The Diamond Release

DICOM Viewer 3.0 Instruction for Use

Sonographic Demonstration of Couinaud s Liver Segments

resource Osirix as a Introduction

TWO-DIMENSIONAL TRANSFORMATION

A PACS-Aware DICOM Image Object

Surgery Support System as a Surgeon s Advanced Hand and Eye

Configuration and Use of the MR Knee Dot Engine

FETAL HEART ASSESSMENT USING THREE-DIMENSIONAL ULTRASOUND

ENG4BF3 Medical Image Processing. Image Visualization

BUILDING THREE-DIMENSIONAL (3D) STRUCTURES

Sonography. 1. Introduction. 2. Documentation of Compliance. 3. Didactic Competency Requirements. 4. Clinical Competency Requirements

An Introduction to Anatomy and Physiology

First floor, Main Hospital North Services provided 24/7 365 days per year

Use of lead shielding for adult chest CT. patient & radiographer experiences

LINCOLN UNIVERSITY DI 281 B Practicum / Externship II in Sonography Summer 2015 Course Syllabus

DWG 001. Blueprint Reading. Line Standards Drawing Symbols. Instructor Guide

Temporomandibular Joint Imaging Using CBCT: Technology Now Captures Reality!

Isometric Circles and Arcs

DIAGNOSTIC MEDICAL SONOGRAPHY

Placenta, Cord, & Fluid

ULTRASONOGRAPHIC EVALUATION OF HIP DYSPLASIA: review. L. Breysem, MD DEPARTMENT OF RADIOLOGY

BACHELOR SCIENCE in MEDICAL IMAGING (BSMI)

Fetal sonographic diagnosis of aortic arch anomalies

Fast mobile reading on the go November syngo.via WebViewer. Unrestricted Siemens AG 2013 All rights reserved.

Prognosis of Very Large First-Trimester Hematomas

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

Surface area measurement using rendered three-dimensional ultrasound imaging: an in-vitro phantom study

ANATOMY & PHYSIOLOGY ONLINE COURSE - SESSION 2 ORGANIZATION OF THE BODY

Basic Abdominal Sonographic Anatomy and Protocol

Introduction to Ultrasound for Obstetrics and Gynecology, 2 nd Session: Post-training report

Testing Theories of Policy-Making: Educational Funding MICAH MCFADDEN

Geometry of Vectors. 1 Cartesian Coordinates. Carlo Tomasi

Anatomy PHL 212. By Dr Tajdar Husain Khan

CSE511 Brain & Memory Modeling. Lect04: Brain & Spine Neuroanatomy

REGISTRATION OF 3D ULTRASOUND IMAGES TO SURFACE MODELS OF THE HEART

First-Trimester Cesarean Scar Pregnancy Evolving Into Placenta Previa/Accreta at Term

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Determining the Posture, Shape and Mobility of the Spine

Low-cost teleradiology for rural ultrasound

CHAPTER 9 BODY ORGANIZATION

Solving Simultaneous Equations and Matrices

9.4. The Scalar Product. Introduction. Prerequisites. Learning Style. Learning Outcomes

Voluson E8 Extraordinary vision

GYNAECOLOGY. Ahmed Mohamed Abbas*, Mohamed Khalaf*, Abd El-Aziz E. Tammam**, Ahmed H. Abdellah**, Ahmed Mwafy**. Introduction ABSTRACT

Automated Breast Volume Scanning 3D Ultrasound of the Breast

Quantitative Comparison of Conventional and Oblique MRI for Detection of Herniated Spinal Discs

Voxar 3D TM. A suite of advanced visualization and analysis software tools

VI. FREQUENTLY ASKED QUESTIONS CONCERNING BREAST IMAGING AUDITS

HOW TO VIEW AND EDIT PICTURES

DISSECTION OF THE SHEEP'S BRAIN

Chapter 18 Symmetry. Symmetry of Shapes in a Plane then unfold

her Admissions Information Diploma 122 2,425 Hours: program. sonography too specializes in general sonography field. good health of the

TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-

Applications of Doppler Ultrasound in Fetal Growth Assessment. David Cole

Ultrasound of the Female Pelvis

Transcription:

Ultrasound Obstet Gynecol 2007; 29: 697 703 Published online in Wiley InterScience (www.interscience.wiley.com). DOI: 10.1002/uog.4009 Standardization of three-dimensional images in obstetrics and gynecology: consensus statement E. MERZ (Germany), B. BENOIT (France), H. G. BLAAS (Norway), K. BABA (Japan), A. KRATOCHWIL (Austria), T. NELSON (USA), D. PRETORIUS (USA), D. JURKOVIC (UK), F. M. CHANG (Taiwan) and A. LEE (Australia) for the ISUOG 3D Focus Group KEYWORDS: 3D ultrasound; gynecology; image standardization; obstetrics; orientation; transabdominal ultrasound; transvaginal ultrasound ABSTRACT Standardization of the display of ultrasound images has so far only been achieved in transabdominal twodimensional (2D) sonography. In contrast, there is a lack of uniformity in the demonstration of transvaginal 2D ultrasound images. The described non-uniformity frequently leads to confusion in the assessment of an image, in particular with regard to the accurate anatomical assignment of left/right and dorsal/ventral. Three-dimensional (3D) sonography offers a unique opportunity to avoid this confusion in the interpretation of ultrasound images, because, independent of primary volume acquisition, the volume can always be rotated so that the stored object can at all times be visualized in a known anatomical position, rendering it of no importance whether the image acquired transvaginally is demonstrated from above or from below. This will also be important in allowing fusion of ultrasound image data with computed tomographic, magnetic resonance and/or positron emission tomography images. In this article we suggest that standardization of transabdominal and transvaginal 3D images does not only provide the inexperienced physician/sonographer with a guide to spatial orientation, but also serves to avoid erroneous topographical interpretations. Copyright 2007 ISUOG. Published by John Wiley & Sons, Ltd. INTRODUCTION Current three-dimensional (3D) ultrasound technology, which allows the storage of complete volumes, has the capacity for routine clinical application. All objects stored in these volumes can be represented in the multiplanar mode as well as in the form of a surface or a transparent image. The major advantage of the multiplanar (or triplanar ) mode is that it enables simultaneous visualization of all three mutually perpendicular sectional planes on the display screen. The ultrasound unit is equipped with three rotary controls, allowing the sectional planes to be rotated so that the object of interest may be viewed in the correct anatomical position, i.e. in the so-called textbook view 1, which, in turn, provides the optimal starting point for further volume analysis. While the freedom of 3D sonography in demonstrating a large number of sagittal, coronal, transverse and oblique section planes within a defined volume offers diagnostic advantages, the less experienced diagnostician frequently finds spatial orientation difficult. This is due to the fact that the image s cranial, caudal, ventral (anterior), dorsal (posterior), right and left edges as known from two-dimensional (2D) sonography no longer correspond to the edges of the display screen, but to the object itself 2. Thus, uncontrolled rotation of the individual sectional planes of an object stored at an oblique angle in the volume may result in it being visualized at such an odd angle that, the inexperienced sonographer in particular may no longer be able to differentiate the right from the left side, or the ventral from the dorsal view. With the two-fold purpose of providing sonographers lacking extensive experience in the application of 3D sonography with a guide to better orientation, and enabling an internationally uniform image display, the International Society of Ultrasound in Obstetrics and Gynecology 3D Focus Group has attempted to standardize the image display in transabdominal and transvaginal 3D sonography. Correspondence to: Prof. E. Merz, Department of Obstetrics and Gynaecology, Krankenhaus Nordwest, Steinbacher Hohl 2-26, 60488 Frankfurt/Main, Germany (e-mail: merz.eberhard@khnw.de) Copyright 2007 ISUOG. Published by John Wiley & Sons, Ltd. C ONSENSUS STATEMENT

698 Merz et al. DISPLAY MODE IN 2D SONOGRAPHY With respect to the standardization of image display in 2D sonography, an international consensus on a uniform image display of the fetus or the uterus has thus far only been reached for the transabdominal approach (Table 1 and Figure 1) 3. An international agreement on a uniform image display has not yet been reached for transvaginal 2D sonography 3 5. Globally, there are now essentially two different display modes: in Germany as well as in several other European countries, the images acquired using a transvaginal probe are shown in a such a way as to allow it to be differentiated at a glance from a transabdominal image 3,5,6. This is accomplished by displaying the transvaginal sonographic ultrasound image on the display screen with the probe position at the bottom of the screen (Table 2 and Figure 2a,b). Conversely, primarily in the United States, South America and some Asian countries, the transvaginal image is displayed like a transabdominal one, i.e. with the probe position at the top of the screen (Table 2 and Figure 2c,d) 3 5. Table 1 Standardization of display frame orientation in two-dimensional transabdominal ultrasound* Display on screen Sagittal section Left side of screen/image Right side of screen/image Upper side of screen/image Lower side of screen/image Transverse section Left side of screen/image Right side of screen/image Upper side of screen/image Lower side of screen/image Anatomical orientation Cranial Caudal Right Left *This standardization applies if the woman being scanned is facing the operator. Table 2 Current display frame orientation in two-dimensional transvaginal ultrasound* Display on screen Anatomical orientation Europe USA/Asia/ South America Sagittal section of the true pelvis Left side of screen/image Right side of screen/image Upper side of screen/image Cranial Caudal Lower side of screen/image Caudal Cranial Coronal section of the true pelvis Left side of screen/image Right Right Right side of screen/image Left Left Upper side of screen/image Cranial Caudal Lower side of screen/image Caudal Cranial *This standardization applies if the woman being scanned is facing the operator. DISPLAY MODE IN 3D SONOGRAPHY Primary multiplanar image In 3D sonography the primary multiplanar image shows all three mutually perpendicular sectional planes (orthogonal image planes) immediately after volume acquisition. These three images are at all times interdependent. In Figures 3 8, this dependency becomes apparent in the progress of the clockwise rotation. The respective corresponding sectional planes are marked by lines in the peripheral areas and the fulcrum is shown as a dot. In the system presented here, the rendered surface view can further be introduced as a fourth image. In the interests of an internationally uniform system of image display, we believe that image documentation in 3D sonography should be aimed at enabling instant assessment, based on the primary multiplanar image (i.e. immediately after acquisition of the volume), of whether the fetus is in a vertex or a breech presentation, or whether the uterus is anteverted or retroverted at the Figure 1 Transabdominal ultrasound images of a fetus with vertex presentation: sagittal (a) and transverse (b) sections. Labels in boxes refer to the anatomy of the mother, while labels without boxes refer to that of the fetus. a, anterior; ca, caudal; cr, cranial; do, dorsal; le, left; p, posterior; ri, right; ve, ventral.

Standardization of 3D images 699 Figure 2 Transvaginal ultrasound images of an anteverted uterus and an ovarian cyst on the left in sagittal and coronal sections of the true pelvis: image displays typical of many European countries (a,b) and of USA, South America and Asia (c,d). The coronal scan through the pelvis shows the anteverted uterus in a transverse section (b,d). Labels in boxes refer to the anatomy of the patient, while labels without boxes refer to that of the uterus. a, anterior wall; C, cervix; ca, caudal; cr, cranial; do, dorsal; F, fundus; le, left; p, posterior wall; ri, right; ve, ventral. Figure 3 Sagittal view of a doll phantom in a water-bath. The right eye was hollowed out to enable differentiation between left and right. The primary images show the doll in vertex (a) and breech (b) presentations. The secondary image shows the doll in the textbook view, after rotation into an upright position, enabling an accurate side-guided assessment independent of the initial position in the primary image. It was necessary to change the direction of rendering to obtain the rendered image in (c). Labels in boxes refer to the anatomy of the mother, while labels without boxes refer to that of the doll. a, anterior; C, chin; ca, caudal; cr, cranial; do, dorsal; le, left; p, posterior; ri, right; T, top of the head; ve, ventral. time of volume acquisition. This can be accomplished for both transvaginal and transabdominal 3D sonography by adjusting the setting so that the object of interest (embryo/fetus/uterus) is in an exact 2D longitudinal section before storing the volume. Should a wider lateral acquisition angle be required, the probe may be rotated by 90 to enable the acquisition of an additional volume. In transabdominal sonography this implies a

700 Merz et al. Figure 4 Transverse view of a doll phantom in a water-bath. The right eye was hollowed out to enable differentiation between left and right. The primary images show the doll in vertex (a) and breech (b) presentations. The secondary image (c) shows the doll in the textbook view, after rotation into an upright position, enabling an accurate side-guided assessment independent of the initial position in the primary image. Labels in boxes refer to the anatomy of the mother, while labels without boxes refer to that of the doll. a, anterior; C, chin; ca, caudal; cr, cranial; do, dorsal; le, left; p, posterior; ri, right; T, top of the head; ve, ventral. Figure 5 Sagittal view of the female pelvis showing an anteverted uterus and an ovarian cyst, left (*). The primary images show European (a) and US/South American/Asian (b) displays. The secondary image (c) shows the uterus after rotation into an upright position, visualized in the correct relationship with the display frame sides (ovarian cyst to the left (*)), independent of the initial position in the primary image. Labels in boxes refer to the anatomy of the patient, while labels without boxes refer to that of the uterus. a, anterior wall; C, cervix; ca, caudal; cr, cranial; do, dorsal; F, fundus; le, left; p, posterior wall; ri, right; ve, ventral.

Standardization of 3D images 701 Figure 6 Coronal view of the female pelvis showing an anteverted uterus in a transverse view and an ovarian cyst, left (*). The primary images show European (a) and US/South American/Asian (b) displays. The secondary image (c) shows the uterus in the textbook view, after rotation into an upright position, enabling an accurate side-guided assessment independent of the initial position in the primary image (ovarian cyst to the left). Labels in boxes refer to the anatomy of the patient, while labels without boxes refer to that of the uterus. a, anterior wall; C, cervix; ca, caudal; cr, cranial; F, fundus; le, left; p, posterior wall; ri, right. Figure 7 Sagittal view of the female pelvis showing a retroverted uterus and an ovarian cyst, right (*). The primary images show European (a) and US/South American/Asian (b) displays. The secondary image (c) shows the uterus after rotation into an upright position (i.e. uterus upside down in retroverted uterus), visualized in the correct relationship with the display frame sides (ovarian cyst to the right), independent of the initial position in the primary image. Labels in boxes refer to the anatomy of the patient while labels without boxes refer to that of the uterus. a, anterior wall; C, cervix; ca, caudal; cr, cranial; do, dorsal; F, fundus; le, left; p, posterior wall; ri, right; ve, ventral.

702 Merz et al. Figure 8 Coronal view of the female pelvis showing a retroverted uterus in a transverse view and an ovarian cyst, right (*). The primary images show European (a) and US/South American/Asian (b) displays. The secondary image (c) shows the uterus in the textbook view, after rotation into an upright position (i.e. uterus upside down in retroverted uterus), enabling an accurate side-guided assessment independent of the initial position in the primary image (ovarian cyst to the right). Labels in boxes refer to the anatomy of the patient, while labels without boxes refer to that of the uterus. a, anterior wall; C, cervix; ca, caudal; cr, cranial; F, fundus; le, left; p, posterior wall; ri, right. volume acquisition arising from a transverse scan, and in transvaginal sonography a volume acquisition arising from a coronal scan. The use of this procedure ensures that of the three orthogonal images shown on the display screen it is in all cases the image at the top left which corresponds to that in the conventional sectional plane in 2D sonography (Figures 3a,b 8a,b). This has the advantage that the initial multiplanar image always allows the immediate identification of the position of the embryo/fetus or uterus at the time of volume acquisition, as in 2D ultrasound (Tables 1 and 2). Secondary multiplanar image The secondary multiplanar image depicts the individual orthogonal image planes after volume rotation. This image is aimed at presenting the object on the display screen in such a way as to allow the correct assignment of ventral and dorsal, as well as of right and left to the actual anatomy. This implies that the object of interest (embryo/fetus/uterus), independent of the primary position, has to be positioned in the sagittal section in an upright textbook view. For a uniform demonstration it is recommended that the volume is rotated so that the image at the top right always demonstrates the sagittal section (Figures 3c 8c). This ensures that the object of interest is visualized automatically in the correct position (i.e. where the right (or left) side of the fetus/uterus corresponds to the left (or right) side of the image) in the coronal and transverse planes, regardless of whether the presentation Table 3 Suggested standardization of display frame orientation in three-dimensional (3D) ultrasound (secondary image) Display on screen Sagittal section of the true pelvis Left side of image Right side of image Upper side of image Lower side of image Coronal section of the true pelvis Left side of image Right side of image Upper side of image Lower side of image Transverse section of the true pelvis Left side of image Right side of image Upper side of image Lower side of image Anatomical orientation Cranial Caudal Right Left Cranial Caudal Right Left After standardized rotation of the 3D volume, the right (left) side of the display screen corresponds to the left (right) side of the fetus/uterus in the coronal and transverse planes. of the fetus is vertex or breech, or whether the uterus is anteverted or retroverted at the time of volume acquisition (Table 3 and Figures 3c 8c). To avoid confusion with the left and right sides in the retroverted uterus, it must be ensured that the uterus is shown in an upside-down position after the rotation in the sagittal plane (Figures 7c and 8c).

Standardization of 3D images 703 A further advantage of the standardized secondary multiplanar image may, in particular, be observed in transvaginal sonography: it is completely unimportant whether, in the primary multiplanar image, the probe is visualized at the caudal (Europe) or at the cranial (USA/South America/Asia) image edge, because one can compensate for this difference by rotation of the individual image planes (Figures 5 8). The availability of a uniform image display system is of tremendous importance, in particular for physicians/sonographers wishing to familiarize themselves with the application of 3D sonography, because it greatly facilitates orientation in the multiplanar as well as in other modes of image rendering (surface and transparent modes). CONCLUSIONS The following steps towards achieving a uniform system for the international display of 3D images are recommended: 1. In the primary multiplanar image, the object should be displayed so that the image at the top left always corresponds to that visualized in the 2D image prior to volume acquisition. This permits valid conclusions to be drawn on the position of the embryo/fetus/uterus at the time of volume acquisition. 2. In the secondary multiplanar image, the volume should be changed by rotation maneuvers to ensure that the embryo/fetus may at all times be visualized in an upright sagittal position in the image at the top right. The same is true for the anteverted uterus, while the retroverted uterus should be rotated into an upsidedown position. This allows rendering of the fetus or uterus in such a way that the right (or left) side of the fetus/uterus in the coronal and transverse planes always corresponds to the left (or right) side of the image. REFERENCES 1. Merz E, Weber G, Bahlmann F, Miric-Tesanic D. Application of transvaginal and transabdominal three-dimensional ultrasound for the detection or exclusion of malformations of the fetal face. Ultrasound Obstet Gynecol 1997; 9: 237 243. 2. Merz E, Bahlmann F, Weber G. Volume (3 D)-scanning in the evaluation of fetal malformations a new dimension in prenatal diagnosis. Ultrasound Obstet Gynecol 1995; 5: 222 227. 3. Merz E. Ultrasound probes, image orientation, and examination techique. In Ultrasound in Obstetrics and Gynecology, Vol.2, Gynecology, Merz E (ed). Thieme: Stuttgart, New York, 2007; 96 100. 4. Timor-Tritsch I. Opinion: Standardization of ultrasonographic images: let s talk the same language. Ultrasound Obstet Gynecol 1992; 2: 311 312. 5. Bernaschek G, Deutinger J. Current status of vaginosonography: a world-wide inquiry. Ultrasound Obstet Gynecol 1992; 2: 352 356. 6. Merz E. Present state of knowledge in vaginosonography. Part I: Fundamentals and diagnosis in gynaecology. Ultraschall Med 1994; 15: 2 10.