Title EVIDENCES ON ENDOSCOPES MANUAL CLEANING AUTOMATION

Similar documents
In use test of a Washer-disinfector reprocessing of flexible endoscopes

ON TRACK Reprocessing Inservice / Competency for GI Endoscopes (EVIS, EXERA, EXERA II)

Christina Bradley Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Flexible Endoscopes: The A,B,C s of Monitoring Manual Cleaning Efficacy!

3M Microbiology. 3M Clean-Trace Hygiene Monitoring Systems. Effective. Hygiene. Monitoring

National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes

URGENT FIELD CORRECTION. REVISED ED 530XT OPERATION MANUALS: Cleaning, Disinfection and Storage, CODE 202B D Operation

Expert Opinion. on the efficacy of. EndoDet and EndoDis + EndoAct. for cleaning and disinfection of. Olympus Gastroscope Type GIF-2T200.

- WATER DAMAGE RESTORATION -

Company background and. portfolio overview

BESTPRACTICE. HTM01-05 Q&A: You can now follow us on Twitter! We have launched our HTM01-05 questions and answers service on Twitter.

A Guide to ATP Hygiene Monitoring

Medical Device Reprocessing: How to Ban the Biofilm!

Current methods: late results (2 to 3 days) contamination spread in the distribution system water consumed

Detergents in CSSD. Wim Renders

Contents. Introduction 2 Components What is ATP? Measuring ATP with Bioluminescence Technology Additional Uses of SystemSURE Plus 6

- WATER DAMAGE RESTORATION -

University of Kentucky / UK HealthCare Policy and Procedure. Policy # A03-030

Hot Topics In Infection Control!

Bed Cleaning Procedure

Residual Organic Soils on Patient used Instruments

Cleaning Validation in Active pharmaceutical Ingredient manufacturing plants

Aseptic Technique Policy and Procedure

Chlorine Residual Testing Fact Sheet

Catalytic Activity of Enzymes

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

TECHNICAL REPORT on the disinfection systems in dental unit water lines.

ETD3 the new standard in endoscope reprocessing.

Testing Waste Water for Fecal Coliforms and/or E.coli using Colilert and Colilert -18 & Quanti-Tray

BIOSECURITY PROCEDURES IN POULTRY PRODUCTION

Reprocessing. Critical & Semi-Critical Equipment

Dot Blot Analysis. Teacher s Guidebook. (Cat. # BE 502) think proteins! think G-Biosciences

Reprocessing Flexible Endoscopes Avoiding Reprocessing Errors Critical for Infection Prevention and Control

Georgia Tech s Award-Winning Renewable Cleaning Program. Tommy Little Associate Director, Building Services

Towards pervasive ICT solutions in the healthcare sector: an integrated technology approach to safer and efficient clinical processes in organizations

book Seite 1 Freitag, 22. Juni : qn=ifkb=l=qo=ifkb. Operating Instructions. båöäáëü. lééê~íáåö=áåëíêìåíáçåë

Infectious Waste Management Plan

FOOD POISONING. Information Leaflet. Your Health. Our Priority. Infection Prevention Stepping Hill Hospital

Hygiene Standards for all Food Businesses

The Determination of an Equilibrium Constant

Water should be removed as soon as possible once the safety of the structure has been verified.

Fighting the Battles: Conducting a Clinical Assay

Enzyme Action: Testing Catalase Activity

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

Effects of Antibiotics on Bacterial Growth and Protein Synthesis: Student Laboratory Manual

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

Back to Basics: Flexible Endoscope Processing LISA SPRUCE, DNP, RN, CNS-CP, CNOR, ACNS, ACNP, FAAN

Cleaning validation of cleanrooms and preparation equipments

Methods of Verification of Cleaning in CSSD. Dr. Winfried Michels Mechelen Oct.2012

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

How to Prepare Powdered Infant Formula in Care Settings

Automated Contact Resistance Tester CR-2601

RELEVANT HACCP CHARTS: Preparation, Service

1/9 INSTRUCTION MANUAL PLEASE READ BEFORE USE ENDOSCOPES

MODULE 2D ENVIRONMENTAL MICROBIOLOGICAL LABORATORY ACCREDITATION PROGRAM (EMLAP) ADDITIONAL REQUIREMENTS

Guidance Note on Flushing

Guidelines 85. Contents. 1. Scope of this guideline. 1. Scope of this guideline

Conjunctivitis - Pink Eye

Training on Standard Operating Procedures for Health Care Waste Management Swaziland 12 May, 2011

K12 Healthy Schools Program

Ceiling Systems for Special applications

Cleaning and High Level Disinfection of Semi-Critical Medical Devices

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

HYGIENE IN THE GALLEY

City of Houston Health Department Laboratory Water & Dairy Section 2250 Holcombe Blvd. Houston, TX DRINKING WATER INFORMATION & TESTING

MANY OF TODAY S SURGERIES USE MINIMALLY INVASIVE

Hazard Analysis and Critical Control Points (HACCP) 1 Overview

Lab Exercise 3: Media, incubation, and aseptic technique

InfectIon PreventIon checklist for outpatient settings:

EXPERIMENT 20: Determination of ph of Common Substances

Department: Manager: Safety Coordinator: Date:

INNOVATION TO MEET YOUR NEEDS

HOBO U14 Data Logger User Manual

Environmental Monitoring of Clean Rooms

SQFI Guidance RE: Allergen Cleaning and Sanitation Practices

ACO Cleaning principles for drainage

Protocol for Disinfection of Cell Culture and Tissue Culture in Media:

ASI 691 Prinicples of HACCP 1

ENZYME ACTION: TESTING CATALASE ACTIVITY

Enzyme Activity Measuring the Effect of Enzyme Concentration

Checklist for a Physical Containment Level 2 (PC2) Laboratory Facility

UltraClean PCR Clean-Up Kit

10-ml Graduated cylinder 40 ml 3% Hydrogen peroxide solution (found in stores) Straight-edged razor blade Scissors and Forceps (tweezers)

RESEARCH CONSENT. Participation in the research will be very similar to normal use of the ubiome service. It consists of:

STUDY GUIDE: ABATTOIR HYGIENE

ABU DHABI FOOD CONTROL AUTHORITY. Food Poisoning

Sekusept Cleaner Liquid Cleaning Agent Cleaning, Desinfecting and Drying

THE BASICS OF DECONTAMINATION

Section 6: Your Hemodialysis Catheter

Department: DOC#: 1 REV: Effective Date: Supersedes: New Subject: Raw Milk Cheddar

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

EudraLex. The Rules Governing Medicinal Products in the European Union Volume 4

Level 2 Award in. Food Safety in Catering (QCF) Specification. Ofqual Accreditation Number 600/0343/1

1. Then f has a relative maximum at x = c if f(c) f(x) for all values of x in some

ATP as an indicator of microbiological activity in tap water

Factors Affecting Enzyme Activity

Shampoo Properties Evaluation General Science

STANDARD OPERATING PROCEDURE FOR NOVA STAT STRIP CONNECTIVITY BLOOD GLUCOSE METERS FOR USE IN LEEDS NHS TRUST

Transcription:

Partecipants Rivara C. Asl Torino 4 - Italy Zamboni G. C. U.O.S. Endoscopia Digestiva Policlinico "G.B. Rossi" - A.O.U.I. Verona Italy Dallevacche A. (Endoscopia Digestiva P.O. Ravenna) Italy Steelco S.p.A Menin Ostani M. 3M Abbate G. Title EVIDENCES ON ENDOSCOPES MANUAL CLEANING AUTOMATION Introduction/Background Prove that Endoscopes Manual Cleaning Automation with Steelco EPW 100 system provide the same results as Manual Cleaning Procedures according to Italian National GI Reprocessing Guidelines ANOTE-ANIGEA update 2011. Endoscopes Full Manual Cleaning automation means process traceability, brushless step and less endoscope handling improving HCWs and patients safety This is the very first objective scientific approach comparing data between manual and automated cleaning procedures. Aims/Objectives The purpose of this research is to create scientific evidences on Endoscopes Manual Cleaning Automation. A pool of 400 endoscopes (200 Experimental Group treated only with EPW 100 system without brushing step using a dedicated and validated single shot detergent SteelcoXide DT & 200 Control Group with National Manual Cleaning Procedures and in use enzymatic concentrated detergent) has been sampled internal channels and external surface - using 3M Clean-Trace Hygiene Monitoring System + 3M Capitale sociale Euro 3.000.000,00 i.v. C.F., P.IVA e Numero Registro Imprese di Treviso: 04311220265 REA TV 339832 1/9

Clean-Trace Water and 3M Clean-Trace Surface. Samples were measured in RLU (Relative Light Unit). The assumption was to find better or equal RLU units number in the Experimental Group. ANOTE-ANIGEA fixed a good manual cleaning procedure under 100 RLU units (cfr Clinical trial of ATP usage for endoscope manual washing validation 2015). The 3M Clean Trace Hygiene Monitoring System used in conjunction with Clean- Trace Water and 3M Clean-Trace Surface was used to measure levels of contamination on endoscope surfaces and in channels water samples. The technology is Adenosine Triphosphate (ATP) present in all animal and vegetable matter, including most food debris, bacteria, fungi and other micro organisms. Measurement of ATP was performed using an enzyme reaction Luciferin/Luciferase (firefly reagent) + ATP = Light. The light emitted is in proportion to the amount of ATP. The intensity of the light emitted from a sample is measured by the 3M Clean Trace Hygiene Monitoring System and is displayed in Relative Light Units (RLU). (Research) Methods Case Control Study: comparing a case series to a matched control series The aim of the research has been achieved involving two GI Labs running a huge number of different procedures per year (>9.000). GI Labs have been equipped with Steelco EPW 100, 3M Clean-Trace Hygiene Monitoring System + 3M Clean-Trace Water and 3M Clean-Trace Surface. The Experimental Protocol was written in cooperation and acknowledged by ANOTE-ANIGEA. After the treatment in the Steelco EPW 100 system and Manual Cleaning Procedures (according to Italian National GI Reprocessing Guidelines ANOTE-ANIGEA update 2011) the 400 endoscopes have been sampled following this protocol steps: 3M Clean-Trace Hygiene Monitoring System daily check with 3M Clean- Trace Water pen, green light if the RLU values are <20; Prepare the endoscope on a dedicated surface avoiding overlapping, dry the final part of the distal tip with medical air. Pass the 3M Clean-Trace Surface pen Capitale sociale Euro 3.000.000,00 i.v. C.F., P.IVA e Numero Registro Imprese di Treviso: 04311220265 REA TV 339832 2/9

around the final part of the distal tip (last 10 cm) and measure RLU results with the 3M Clean Trace Hygiene Monitoring System; Record RLU surface values in a defined Experimental protocol database; Position the channel separator to open endoscope channels; Connect the endoscope suction valve to the sterile solution 0,9% through a dedicated silicon connector changed every time according to the endoscope application (Upper GI or Lower GI procedures); Flush channels with the sterile solution and collect the liquid going out from the distal tip (approximately 50 ml) in a sterile container; Take a sample of water from the sterile container by the 3M Clean-Trace Water pen and measured RLU results with the 3M Clean Trace Hygiene Monitoring System; Record RLU water values in a defined Experimental protocol database. If the endoscope was part of the Experimental Group treated with Steelco EPW 100 system after the sampling procedures HCWs have to brush it before the reprocessing in the AER. Statistical or interpretative analysis software programs used to record data are 3M Clean-Trace Data Trending Software and excel database. Findings/Results Table 1 1. Hospitals 1 (Osp1) and Hospital 2 (Osp2) RLU represented in logarithmics values to be better represented in the graphic scale. In the graph value 1,0 corresponds to 10 RLU; value 2,0 to 100 RLU; 3,0 to 1.000 RLU etc; 2. The blu line identify 2,30 Log corresponding to 200 RLU 3. The first 106 values (half chart) represents Osp1, the others Osp2 4. Between Hospitals the endoscopes were ranked in the following way: Colonscopes Others (Echoendoscopes e Duodenoscopes) Gastroscopes 5. RLU values increase from Colonoscopes to Gastroscopes Capitale sociale Euro 3.000.000,00 i.v. C.F., P.IVA e Numero Registro Imprese di Treviso: 04311220265 REA TV 339832 3/9

6. Colonscopes are easier to clean than Gastroscopes Table 1 Table 2 1. In the first 4 raws of the table are showed the RLUs mean values of both Hospitals (D). Values enclosed every kind of endoscopes tested in the 4 different categories (B). 2. Mean RLUs values are very similar (D) 3. Max RLUs values reached considering the 95% of the endoscopes tested (G). This value is interesting separating Coloscopes from Gastroscopes (raws from 5 to 8) and Osp1 from Osp2 (raws H and I) 4. Coloscopes passed and failed RLUs values are around 100 in the 95% cases while Gastroscopes shows 200 RLUs (compared to Clinical trial of ATP usage for endoscope manual washing validation 2015) 5. Osp1 has a better performance than Osp2 with Gastroscopes RLUs values similar to Colonoscopes referred to internal channels cleaning but has a worst performance in external surface cleaning Capitale sociale Euro 3.000.000,00 i.v. C.F., P.IVA e Numero Registro Imprese di Treviso: 04311220265 REA TV 339832 4/9

Table 2 Tables 3 RLUs internal channels values Osp1 is always under 100 RLUs threshold in both Experimental and Control group (in 106 endoscopes only 5 values are out of the mean). This shows a well standardized cleaning process. Graphic vertical size is smaller in the left side rather than in the right one. Osp2 has highest and less recurring values with under control values over 327 and 427 RLUs. Capitale sociale Euro 3.000.000,00 i.v. C.F., P.IVA e Numero Registro Imprese di Treviso: 04311220265 REA TV 339832 5/9

Tables 3 Capitale sociale Euro 3.000.000,00 i.v. C.F., P.IVA e Numero Registro Imprese di Treviso: 04311220265 REA TV 339832 6/9

Tables 4 RLUs surfaces values In Control group we see the same performance difference between the two Hospitals with some under control values. Better surface RLUs values are referred to Osp2. The assumption is that less attention has been provided in both groups during manual surface cleaning maybe because there were no variables to be investigated. Tables 4 Capitale sociale Euro 3.000.000,00 i.v. C.F., P.IVA e Numero Registro Imprese di Treviso: 04311220265 REA TV 339832 7/9

Summary and Discussion This firs pool of RLU data show values alignment between Manual Cleaning Automation with Steelco EPW 100 system and Manual Cleaning Procedures - according to Italian National GI Reprocessing Guidelines ANOTE-ANIGEA update 2011. Routinary controls are still strongly reccomended as a Best Pratice in monitoring cleaning efficacy both in manual and automated cleaning processes in order to guarantee patients safety. Conclusion Additional investigations will be ran in order to be able to claim and endorse the full automation of the manual cleaning step such as: Revision of the Experimental Protocol in conjunction with the ANOTE/ANIGEA President and Regional Referents Collect almost 3.000 RLUs samples from different GI Labs (1.500 CONTROL & 1.500 EXPERIMENTAL) + 1.500 microbiological cultures for channels cleaning efficacy (750 CONTROL & 750 EXPERIMENTAL) Detergent standartization in both groups (CONTROL & EXPERIMENTAL) avoiding a potential BIAS Trace the kind of the exame performed with the endoscope (diagnostic or operative) Learning outcomes + Relevance to Nursing Practice In GI Labs Endoscopes Manual Cleaning Automation with EPW 100 will improve safety for: HCWs à less chemicals handling and exposure, full traceability of this critical step, less injuries and more time for other tasks; Patients à guarantee of the same treatment without human risk, new fresh chemical used for each cycle and cross contamination reduction; Capitale sociale Euro 3.000.000,00 i.v. C.F., P.IVA e Numero Registro Imprese di Treviso: 04311220265 REA TV 339832 8/9

Endoscopes à less handling and maintenance (better integrity of internal channels without brushing), documented evidences of liquid pressure and flow inside channels providing alarms in case of obstruction. The introduction of 3M Clean Trace Hygiene Monitoring System can help to control endoscopes channels and surfaces cleanliness driving the GI Lab to take corrective actions in case of RLU values higher than 100. Bibliography 1) The repeatability of hygiene test systems in measurement of low levels of ATP. W.J. Simpson, C.J.Giles, H.A. Flockhart. Cara Technology Limited, Leatherhead Enterprise Centre, Randalls Road, Leatherhead, Surrey, KT227Ry, UK Report 30606, 27 July 2006 2) Monitoring the disinfection of flexible endoscopes using ATP bioluminescence (Biotrace international); 3) Assessment of the hygienic status of hand-contact surface on a busy general hospital ward in the UK (Nerys Bennion, Peter Obee); 4) C J Griffith, R A Cooper, J Gilmore, C Davies, M Lewis. An evaluation of hospital cleaning regimes and standard. Journal of Hospital Infection 2000;45:19-28. 5) EN 13549:2003 Cleaning services - Basic requirements and recommendations for quality measuring systems 6) Italian GI Guidelines ANOTE/ANIGEA update 2011 Capitale sociale Euro 3.000.000,00 i.v. C.F., P.IVA e Numero Registro Imprese di Treviso: 04311220265 REA TV 339832 9/9