Spray Controller Troubleshooting



Similar documents
Essential Electrical Concepts

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

air seeder monitor 1020 Air Seeder Monitor Installation & Operation Instructions

TMS TANK MANAGEMENT SYSTEM

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

VOYAGER 570G. 744A Sprayer Control

Rutland 913 Windcharger Fault Finding Guide

G-100/200 Operation & Installation

APAds Air Conditioning Protection and Control System. Technical Help Frequently Asked Questions

Thermo Top - Troubleshooting Tree

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

PUSH BUTTON START INSTALLATION MANUAL

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Electric Brake Trouble Shooting Guide

Pro Logic Version Diagnostics Manual

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Meritor WABCO Pneumatic Antilock Braking System (ABS) 42.22

Electronic Brake Controller Hayes Brake Controller Company ENERGIZE III P/N # 81741B or ENERGIZE XPC P/N #81745 OPERATION MANUAL

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

HEAT SIPHON ANSWERBOOK

What is a multimeter?

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Quickie Rhapsody Service Manual

Electronically Controlled Air Suspension (ECAS) for Trucks

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

OPL BASIC. Dosing System for Professional Laundry machines. Contents

FUEL-16, Troubleshooting Fuel Supply Problems

Hydraulic Trouble Shooting

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Workshop Repair Manual

Troubleshooting Salt Generators

Companion Service Guide

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

Hydraulic Troubleshooting PRESENTED BY

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Operational Overview and Controls Guide

Electrical Diagnostic Tools

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

FLOWMETER INSTALLATION INSTRUCTIONS

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

MP-4000 Alarm List (Software version or later)

ABS Flash Code (Blink Code) Instructions

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Passive Anti -Theft System (PATS) Diagnostic Flowcharts. Issue: This bulletin provides diagnostic information for the Passive Anti-Theft System.

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

i ChatterBox! Motorcycle Security

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

The Starting System. Section 4. Starting System Overview. Starter. The starting system:

SPA BUILDERS LX-10 STANDARD TROUBLESHOOTING APPROACH

ELECTRICAL CIRCUITS. Electrical Circuits

BERMAD Fire Protection

GENERAL SCIENCE LABORATORY 1110L Lab Experiment 6: Ohm s Law

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Windshield Wiper Motors

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

AutoRanging Digital MultiMeter

System Tel (Telephones) Ltd Fax Web

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

FLOWTRON UNIVERSAL. Service Manual

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Part Name/Description Part Number Quantity. Power Cable

Streaming Potential System (SPT1000, SPD1000)

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

EC450 Power Control System

Installation and Operation Back-UPS 1250, 1300, 1500

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

Technical Information

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

Using your LED Plus keypad

Technical Guide 08/15/14

350, 500, 650 and 1000 MODELS

Series and Parallel Resistive Circuits Physics Lab VIII

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

OPERATION MANUAL VALVE CHECKER G

Model 201 Wiegand Touchpad Reader Installation Guide

Troubleshooting and Diagnostics

Lab 3 - DC Circuits and Ohm s Law

Single Channel Loop Detector

Transmitter Interface Program

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)


TROUBLESHOOTING ABS DIAGNOSTIC CODES L20293, Rev. 1/13

RADIANT PLASMA 4700 Plasma Spark Generator

D200+ Auto-Dialler Installation/Operators Manual

A4 Air Conditioning Control Circuit Troubleshooting Rev 7, 6/18/2009

Transcription:

Spray Controller Troubleshooting 1 Controller does not turn on. a) Fuse on loom has blown. b) Internal poly fuses have blown. Disconnect controller from power and wait. After poly fuses reset connect power again and turn on. If not repeat and wait longer. c) Check that connections to battery are clean and tight. Try again with the engine running. d) Disconnect controller s power cable and test voltage is 12-13.8V DC from battery. Reconnect power to the controller and check that there is 12V between power wires. e) Check that red wire is to positive and black wire is to negative. f) Connect controller direct to another 12 Volt battery known to be in good condition. 2 LCD display drops out. a) If display rectifies when engine running this indicates battery is in poor condition or connections to battery are poor. b) If problem persists when engine running, then voltage supply is low or low current is a problem due to poor connections at battery or corroded inline fuse holder on loom. c) Clean battery terminals and power cable connections. d) Connect controller directly to an independent battery to prove if controller is OK. e) Disconnect proportional control valve - if problem goes away then this confirms insufficient current available from power cable. 3 Controller looses calibration values. 4 Speed readout too fast or too slow. 5 Speed readout jumpy. a) Controller not connected directly to battery. Connect black from loom directly to negative and red to positive side of battery. Do not share power with any other devices such as foam markers, using the controller loom. a) Incorrect wheel calibration factor. Repeat wheel calibration procedure. a) Make sure magnet is facing sensor correctly as shown in "Wheel Sensor Installation". Use of an alternative magnet may cause problems due to wrong orientation of magnet. b) Check that wheel magnet is present and the magnet is 10-15 mm away from wheel sensor as they pass. Magnet too close can cause jumpy speed. c) If the readout is jumpy, it indicates that the pulses from the wheel sensor are inconsistent. Check for poor or intermittent connections to sensor. d) Check sensor cable for physical damage, making sure cable has not rubbed through to the chassis due to sharp edges. e) If fault can not be found, enter TEST WHEEL" menu. Drive slowly forward and listen to the beeps. The sound should be rhythmic at a fixed speed. If the sound is jumpy, and wiring is OK, then replace sensor. 1

6 Speed readout intermittent or stays at zero a) Fault is probably a broken or intermittent connection to wheel sensor or perhaps a faulty sensor. Check all connections first. b) Make sure clearance between wheel magnet and wheel sensor is 15-20 mm. Check for the correct sensor, it should be black. c) Enter TEST WHEEL" menu. d) Disconnect wheel sensor from cable and use a short length of wire to short circuit across connector plug to wheel sensor cable (black & white wires). e) Controller in cab should 'beep' continuously whilst wires are short circuited. Now wriggle all connections from wheel sensor plug back to controller to try and make beep sound fail thereby isolating cause of fault. f) If wiring and controller can not be faulted, replace sensor. g) If no audible response in TEST WHEEL menu from shorting out wiring at wheel sensor connection, short out the relevant pins in the Deutsche breakaway. L & P pins at the breakaway for the Primo 400. A & Q pins for the 24V1. h) If no audible response, problem is in the sprayer loom. If no audible response, problem is in the tractor loom or controller. 7 Wheel sensor test procedure a) USE A MULTIMETER ONLY TO TEST THE WHEEL SENSOR. b) Disconnect wheel sensor from cable. c) Switch Multimeter "ON: and select "OHMS" scale. d) Touch test probes together and meter needle should read zero 0 Ω resistance. e) Connect test probes to wheel sensor pins. If meter goes immediately to zero without magnet, then sensor is short circuit (faulty). If meter stays to left of scale, hold wheel magnet in front of sensor, meter should go straight to zero. If meter fails to change, then sensor is open circuit (faulty). 8 Total and Trip area incorrect. 9 Total and trip area won't record a) Check SPEED readout is correct and steady - if not, this will affect the area totals. b) Recheck WIDTH calibration is set correctly in metres. a) Check that SPEED readout is working. b) At least one section valve must be switched on. c) Flow sensor must be working OK. d) Check that L/MIN or G/MIN is working. 2

10 Rate readout stays at zero. a) Check "SPEED" readout. b) Use a multimeter to check for + 12 volts between red and black wires (on loom) to flow sensor. Check for +12 volts at the relevant pins of the breakaway plug on the tractor loom. O & P at breakaway for the Primo 400. A & B pins for the 24V1. Flow sensor wiring Primo 400 24V1 Description Brown Red Red +12 V White Black Black Ground Green White/Black Grey Signal c) Enter TEST FLOW menu. d) Disconnect flow sensor plug and use a short length of wire or long nose pliers to short out between the pins corresponding to the white and green wires of the flow sensor connector plug feeding back into the loom. e) A continuous beep should be heard from the spray controller. Now wriggle all wiring and connections from flow sensor plug to rear of spray controller and listen if the beep can be made to drop out. f) If no beep heard, then repeat test by shorting out the relevant pins at the Deutsch breakaway. If no audible response then controller or tractor loom may have fault. 11 Rate readout fluctuates more than +/- 2%. Big fluctuations may be normal for 2-5 seconds only when changing speed or rates. Check SPEED readout is stable at a constant driving speed. Check all calibrations are set correctly. Check if flow sensor is giving a stable pulse rate as follows: * Activate section controls * With pump running, and stationary, enter the 'flush mode'. *Adjust the flow in L/MIN using the up and down arrows to set a small rate such as 20L/MIN. Place a container under the section to capture spray. Start timing for a minute. After a minute measure the volume of liquid it should be 20L. If not the flow sensor is either faulty or requires cleaning. Check the nozzle manufacturers spray chart to see if the rate selected is compatible with the nozzles and driving speed. If nozzles are too large for the intended rate and speed, then the proportional valve will hunt for the right setting. Increase rates or get the right nozzles for the job. If SPEED and L/MIN RATE fluctuating, follow section flow sensor service procedure. Fluctuation could be caused by a faulty pressure relief valve that dumps pressure prematurely, this will cause a continuous self defeating response from the spray controller as it tries to compensate. Water hammer could be the reason. Check if air is entering the system. 12 Rate low alarm or can t reach maximum speed. Indicates target rate selected is not achievable. Check manufacturer s spray chart to see what rates should be achievable at maximum pressure. Check inline filters and nozzle filters which may be blocked causing restriction to achievable flow rates. Check flow sensor inlet for debris causing restriction 3

13 Flow sensor inaccurate. Make sure flow direction arrow points in direction of flow. If no diaphragm or piston pump, make sure pump is not hammering. Remove flow sensor and chek inlet strainer on flow sensor is clear. Follow flow sensor calibration and make sure correct flow cal factor is set. Follow "FLOW SENSOR SERVICING PROCEDURE". 14 Control valve won't open automatically. 1.Check WIDTH calibration factor is correctly entered and make sure boom control switches are activating sections. 2. Check FLOW cal factor is set. 3. Check WHEEL cal factor is set. 4. Check rates are set. Check 25-way connector at rear of spray controller is inserted properly and check implement breakaway connection making sure pins on male side are contacting properly. Check ground speed readout is working correctly. If no pressure, make sure pump is working correctly. 15 Valve keeps opening while spraying. Check speed readout is working accurately. Check flow sensor operation. Read nozzle manufacturer's spray chart and make sure the intended rate can be delivered at the speed required within the minimum recommended operating pressure. 16 Valve response too slow to start spraying. If switching spray OFF regularly you must use MASTER section control to instantly start / stop spray. You must switch OFF master switch whilst still travelling at working speeds. If you shut OFF too late the valve will have opened to bypass. If centrifugal pump, when shutdown, pump must be able to cycle some material back to tank, otherwise cavitation may cause loss of pressure. If wheel cal figure is greater than 2 metres then additional magnets may be required to improve response at slow working speeds. 17 Rate high alarm activates for more than 2-3 seconds. 18 Pressure too low under auto control. Check proportional valve operation. Check that you are not operating within the slow hold parameters. Check all calibration factors are correctly entered. Make sure significant pressures available. Run sprayer and check hoses for split after proportional control valve. Make certain nozzles are correct for the job. 4

Summary of Alarms Alarm Type RATE TOO HIGH RATE TOO LOW UNIT ON HOLD UNIT OFF HOLD Description Speed too slow to control to rate set Speed too fast to control to rate set Monitor stopped accumulating data and product is returned to back to the tank Monitor is returned to the normal spray mode. Flow Rate Calculation MAX L/Ha x kph x WIDTH (m) = L/min 600 eg. 1500 x 8 x 4 = 80 L/min 600 5