VACUUM PUMP EXHAUST FILTERS

Similar documents
Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Compressed Air Filters

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Air Eliminators and Combination Air Eliminators Strainers

CSD WATER REMOVAL FILTERS FOR DIESEL

Ultipleat High Flow Filter System

Ultra-Filter. Compressed Air Filter. DF Series

Drainage and Grease Management for the Commercial Kitchen

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Air/Vacuum Valves. Removal of Air from Pipelines. Allow the Entry of Air into Pipelines. Application:

Waste Oil Handling, Spill Containment & Lighting

Used Fluid Handling Portable Used-Oil Gravity Drains

FRL/AirCare Air Controls & Accessories

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

Block and Bleed Gauge Valves M25 and M251

COMPOSITE MESH PAD (CMP) DRY SCRUBBERS III TM ENFORCER III

6 Crankcase Ventilation

HELPFUL HINTS ON PREPARING COMPRESSED AIR

Oil Sight Glass BENEFITS

Installing a Probe. Typical Installation

400B SERIES DIAPHRAGM PUMP

Basic Hydraulics and Pneumatics

A Guide to Trouble-Free Cooling Towers

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Operation & Maintenance Manual

Steam System Best Practices Condensate System Piping

BHS CANDLE FILTER APPLICATIONS FOR CLARIFICATION / RECOVERY OF SOLIDS FROM CHEMICAL SLURRIES

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Morrison Bros. Co. General Product Specifications

During Various Aluminum Fabricating Operations

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

REFRIGERATED COMPRESSED AIR DRYERS

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Rexroth Hydraulic Pump A10VO Series User Manual

Atlas Copco Quality Air Solutions. Compressed Air Filters

AIR LINE VALVES AND GAUGES

ThermoStar Refrigeration Air Dryers

Automatic Self-Cleaning Strainers

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

SOLENOID VALVES AND PNEUMATIC VALVES

CleanAir Air Control Equipment Accessories for superior spray finishing. Filters Regulators Gauges Valves

Medical Air Systems: Scroll

pdi PLASTIC DRUM INSTITUTE Plastic Drum Paneling Issues

7. Chemical Waste Disposal Procedures

How To Remove A Large Particle From A Large Tank

MFP14, MFP14S and MFP14SS Automatic Pumps

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

Chapter 5 Water, Plumbing, and Waste

AMX300 DirectConnect Mixing Valve Kits

Standard Hydraulic Piping Flushing Procedure

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Mechanical shaft seal types and sealing systems

Recharge Procedure for Telemark TVP-2000 and TVP-3500

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

SOLFRUNT Pressure Gauges and Other Products for the Process Industries

15/40/80CN Series Coreless Medium Pressure Filters

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

World-Class Oil Sampling It is Possible

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

FLASH TANK ECONOMIZER PRODUCT GUIDE

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Druck PV 62x pneumatic/hydraulic pressure stations

DIESEL FUEL CONDITIONING

REGULATORS 175/153 Series

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

introduction to constant level lubrication

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

Optimizing Tank Cleaning Operations

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

What Does A Sump Pump Do?

KF Needle & Gauge Valves

Portable Lube Carts. PRO/MARK INDUSTRIALS Div. R.D. Lewis Sales Limited

NFPA31FuelOilPiping 1 Revised

Mechanical Seal Piping Plans

Dryaire Desiccant System

Guidelines for Precast Concrete Grease Interceptors

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

6.7L Diesel Fuel System Contamination Diagnosis and Service Procedure Job Aid (Revised March, 2012)

Balston Liquid Filters

Blasting Basics. Section H: Table of Contents. Blasting Basics: Cabinet Capabilities

Master Catalogue I August 2011

DESIGN, OPERATION, AND MAINTENANCE CONSIDERATIONS FOR IMPROVED DRY GAS SEAL RELIABILITY IN CENTRIFUGAL COMPRESSORS

300 Series PA Pump and Cooler Assemblies

LifeASSURE PFS Series Filter Cartridge Integrity Testing

Section 8 Storage Tanks & Equipment

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

This will also provide you with the knowledge to insure long life for your Investment

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

PLUMBING & CROSS-CONNECTION CONTROL

Transcription:

Our vacuum pump exhaust filter assemblies remove heavy concentrations of extremely fine oil droplets from vacuum pump exhaust to permit pumps to discharge into clean work areas or recycle clean gas to the process. These filter assemblies utilize one or more replaceable microfiber filter elements to coalesce the oil from the exhaust gas. At the heart of the vacuum pump exhaust filter assembly is the two stage 50CS grade microfiber element which captures the oil mist droplets within the depth of the element s wall and coalesces the mist into larger droplets, thus allowing gravity to drain them from the assembly. Since the coalesced liquid drains from the elements at the same rate that liquid droplets enter the elements, the elements have an unlimited life when coalescing relatively clean liquids, and they operate at their initial retention efficiency even when wet with liquid. Features: Rugged Construction Easy To Install Low Cost, Completely Disposable Elements Low Back Pressure, Exceptional Life Available In Aluminum And Stainless Steel Recover Expensive Lubricating Fluids Applications: Exhaust Directly To Outside Environment Ideal For Packaging Industries Semiconductor Protection Vacuum Pump Process Exhaust Polishing Allows Venting Of Exhaust Directly Into Workplace Environment Our disposable 50CS Grade Microfiber Filter Elements are specifically designed for all vacuum pump exhaust applications. The filters have an efficiency rating of 99.99% at 0.0 micron and are designed to have an initial dry pressure drop of less than 2 psi when sized correctly. We recommend changing filter elements when the pressure drop reaches psig or the pump manufacturers quoted maximum back pressure, whichever is lower. Do not undersize a filter assembly, since this will reduce performance and may damage the pump. Since Headline Microfiber Filter Elements operate at their initial retention efficiency even when wet with oil, the filter elements need to be changed only when the back pressure on the pump reaches an unacceptably high level as a result of build-up of particles in the filter elements. There usually is a very low particle contamination in vacuum pump exhaust, so filter element life is quite long one year or more in most applications. The two stage filter element structure minimizes the possibility of carryover of coalesced oil, and the all-inorganic silica composition is completely resistant to lubricants and virtually any chemical found in vacuum pump exhaust. The maximum temperature limit for a filter assembly is determined by the seals or plastic materials in the system. All vacuum pump filters have a drain port at their base to remove any collected oils. This port may be hard piped to continually drain into a reservoir. Our vacuum pump exhaust elements are % interchangeable and equivalent to the Balston H series of vacuum pump filter elements.

Choose the correct assembly: All Vacuum Pump Exhaust filter assemblies come complete with 50CS grade coalescing filter elements. Assemblies with multiple elements have an integral stainless steel mesh entrainment separator pad to reduce the possibility of oil carryover. This pad sits snuggly above the elements at the outlet port. Three simple rules to choosing the correct Vacuum Pump Exhaust filter:. For non-hazardous and non-corrosive, select our Aluminum Version. 2. For leak-tight service because of toxic or hazardous gas, or if a corrosion-resistant stainless steel filter housing is required, select our Stainless Steel Version, designated with an S in the part number example 4S-50CS. Next select the assembly which has a flow capacity equal to or greater than the vacuum pump flow capacity. Quick Reference Chart on our Vacuum Pump Exhaust filters More detailed information are on the next two pages: SIZING CHART Maximum Flow Rate (scfm) Line Size Aluminum Housings (Non-Corrosive) Stainless Steel Housings (Corrosive) /2 NPT 420-50CS 420S-50CS 9 /4 NPT 425-50CS 425S-50CS 20 NPT 4-50CS 4S-50CS 45 /2 NPT 4-50CS 4S-50CS 90 2 NPT 44-50CS 44S-50CS NPT 4-50CS 4S-50CS 200 NPT 44-50CS 44S-50CS 450 4 Flange 456-50CS 456S-50CS Custom Sizes are Available

Aluminum Construction For Non-Hazardous and Non-Corrosive Applications All Vacuum Pump Exhaust filter assemblies come complete with 50CS grade coalescing filter elements. TECHNIC INFORMATION Aluminum Housing Model 420-50CS 425-50CS 4-50CS 4-50CS* Inlet/Outlet Port Size (NPT) Drain Port (FNPT) Aluminum Maximum Pressure (psig) Diameter Materials Of Construction: () /2 /8.9.9.64.5 25-64-50CS -2-H /4 /8 9 6.02.5 5-89-50CS 200-6-H /4 20.6.8 5-2-50CS 200-5-H () Material abbreviations: = Aluminum, = 6 Stainless Steel, = 4 Stainless Steel (*) Models 4 and larger come complete with back pressure gauge and anti-reintrainment mesh pad /2 /4 45.00 9.45. 5-2-50CS 200-5-H TECHNIC INFORMATION Aluminum Housing Model 44-50CS* 4-50CS* 44-50CS* 456-50CS* Inlet/Outlet Port Size (NPT) w/ /4 FNPT Drain Aluminum Maximum Pressure (psig) Diameter Materials Of Construction: () 2 90.00 9.49 28.94 9.84 2.99 20.2 5-2-50CS 200-5-H 200 9.84 2.99.6 () Material abbreviations: = Aluminum, = 6 Stainless Steel, = 4 Stainless Steel (*) Models 4 and larger come complete with back pressure gauge and anti-reintrainment mesh pad 4 Flanged 450 5.98 9. 5.8 6

Stainless Steel Construction For Hazardous, Corrosive, and High Temperature Applications All Vacuum Pump Exhaust filter assemblies come complete with 50CS grade coalescing filter elements. TECHNIC INFORMATION Stainless Steel Housing Model 420S-50CS 425S-50CS 4S-50CS 4S-50CS* Inlet/Outlet Port Size (NPT) Drain Port (FNPT) () Stainless Steel Maximum Pressure (psig) (2) Diameter Materials Of Construction: () (4) /2 /8 2.6 2.6 4.0 2.5 25-64-50CS -2-H /4 /8 9 5.6.54 5-89-50CS 200-6-H /4 20.6 9.05 5-2-50CS 200-5-H () Material abbreviations: = 6 Stainless Steel, = 4 Stainless Steel (*) Models 4S and larger come complete with back pressure gauge and anti-reintrainment mesh pad /2 /4 45 8.62.8 6.88 5-2-50CS 200-5-H TECHNIC INFORMATION Stainless Steel Housing Model 44S-50CS* 4S-50CS* 44S-50CS* 456S-50CS* Inlet/Outlet Port Size (NPT) w/ /4 FNPT Drain Stainless Steel Maximum Pressure (psig) Diameter Materials Of Construction: () 2 90 8.62.8 28.94 0.9 4.05 9.02 5-2-50CS 200-5-H 200 0.9 4.05.0 () Material abbreviations: = 6 Stainless Steel, = 4 Stainless Steel (*) Models 4S and larger come complete with back pressure gauge and anti-reintrainment mesh pad 4 Flanged 450 5.98 9. 40.0 6

VACUUM PUMP INLET FILTERS The IN series of housings is designed to protect small vacuum pumps from liquid and solids in the process stream that may be pulled into the pump. At the heart of the inlet filter is the completely disposable RC-type coalescing element. Made entirely from borosilicate glass fiber and phenolic binder, it is compatible with all compressor lubricants and will operate at temperatures up to F. The RC-type element has a two-layer structure, inner particle capture-layer and an outer drainage-layer. Liquid droplets remain mobile once captured and travel through the finepored capture-layer, along the intersecting microfibers, growing in size as they progress. These coalesced droplets are transferred to the large-pored drainage-layer, where they drain by gravity into the filter bowl. Oil collected in the filter bowl can then be drained and reused. The RC reinforced filter element is durable to handle particle build-up. This extra strength provides extra pump protection. We also offer 4A elements to protect the pump against oil back streaming. Please consult UFS with your specific inlet requirements. These units are good for service to 2 Torr. SIZING CHART Maximum Flow Rate (scfm) Line Size Aluminum Housings (Non-Corrosive) Stainless Steel Housings (Corrosive) /4 MNPT IN-DIF-LN-RC /2 FNPT IN-60NPR-RC IN-420S-RC KF 25 IN-42-RC 9 /4 FNPT IN-425-RC IN-425S-RC 2 FNPT IN-80AHP-RC 20 FNPT IN-4-RC IN-4S-RC 2 /2 FNPT IN-85AHP-RC IN-50-RC 45 2 FNPT IN-90AHP-RC IN-62-RC