Defender 3000 Series Base Instruction Manual

Similar documents
ATS Overhead Table Shelf System INSTRUCTION MANUAL

i410/i1010 AC/DC Current Clamp

BroadBand PowerShield. User Manual

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Advantium 2 Plus Alarm

Sartorius Midrics Weighing Platforms

TWO/FIFTY/TWO STEREO POWER AMPLIFIER

62 Max/62 Max + Infrared Thermometer

NFC Communication Tray Model: HHX-IT3-Z

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

PART 1 - INTRODUCTION...

How To Use A Cdm250 Digital Multimeter

Global Water Instrumentation, Inc.

Thermocouple Thermometer Models

HIH-4000 Series Humidity Sensors

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

Hot Water Urns. all models. Helpline. v3.0

SP-1700 OWNERS MANUAL

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

INSTRUCTION MANUAL MODEL PCD-88

Multi Tube Rotator. Model No. 4632Q CE CECN /05/11

Pocket Tach 99 (PT99) Non-Contact Tachometer

Operating instructions Platform/floor scales

ECLIPSE MX. Motorized Fader Control Surface. Users Manual

Series 510 Submersible Level Transmitters

Temperature Humidity Meter

16/32 Channel 1U Rack Mount CCTV Power Supply

Sip/Puff Switch User Guide

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

How To Use The Visifault Visual Fault Locator

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

ROTOR LOADER OWNER S MANUAL

RGC-IR Remote Gas Calibrator for IR400

BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960. This manual covers installation and operation procedures for BNC AM members:

staple gun with 5/16 Long staples

Thermistor Thermometer MODEL NO

Installation Instructions

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Model SRMD Setra Remote Monitoring Display

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Threaded Inline Air Heaters

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Wind Direction Smart Sensor (S-WDA-M003)

CELO5. User & Installation Manual.

AXIS T81B22 DC 30W Midspan

XP Series Balances Operation Manual

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

7 FUNCTION DIGITAL MULTIMETER

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Installation Guide Smart-UPS X External Battery Pack SMX120BP

TIG INVERTER INSTRUCTION MANUAL

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Subminiature Load Cell Model 8417

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Super Slider ADJUSTABLE FROM Model #HD26229

Global Water Instrumentation, Inc.

3 WATT LED SPOTLIGHT Model No. SLM

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Owner s Manual & Safety Instructions

User Manual. CFG253 3 MHz Function Generator

Installation Instructions

Meaco 30L and Meaco 40L dehumidifier instruction manual

Owner's Manual. Assembly Instructions. Warranty. This Product is Produced Exclusively by Tan Black

aseries A13B Mini Bullet Camera User Manual

Operations Manual Blast Chiller

64-CHANNEL INTEGRATED AMPLIFIER

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

INFRARED QUARTZ WALL HEATER

Mounting instructions. Force transducer. A en

12 Volt 30 Amp Digital Solar Charge Controller

USB Rover port USB m Cat 5 Extender. User Guide

323/324/325. Calibration Manual. Clamp Meter

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Leak Detection System

Single Station Remote Alarm

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Water Leak Detection System

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Unpacking, Installation, and Customization

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

Tina 2A/B Adaptor unit

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Laptop Power Adapter for home/office User Manual

CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor

Model UT713 OPERATING MANUAL

User Guide. HDMI Active Cable Extender. DVI-7370c

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

RX-18B ORDERCODE D3314

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION

Instructions A Amp AC/DC Current Probe

Transcription:

Defender 3000 Series Base Instruction Manual

Defender 3000 Series Base EN-1 INTRODUCTION This manual covers installation, and maintenance instructions for the Ohaus Defender TM 3000 Series Base. Please read this manual completely before installation and operation. SAFETY PRECAUTIONS For safe and dependable operation of this product, please comply with the following precautions: Operate the base only under ambient conditions specified in these instructions Ensure that the load cell cable does not pose an obstruction or tripping hazard Do not operate the base in hazardous environments or unstable locations Do not drop loads on the base Do not lift the base by the top frame; always lift from the bottom frame when moving the base Service should only be performed by authorized personnel INSTALLATION Unpacking Unpack and inspect the product to make sure that all components have been included. The package includes the following: Base Weighing Pan Warranty Card Instruction Manual When purchased as a complete Defender 3000 Series Scale, will also include: 3000 Series Indicator Column Assembly Assembly Weighing Pan Place the weighing pan securely over the rubber load pads on the top frame of the base. Wiring Connections Connect the load cell cable to an indicator using the wiring codes in Table 1 below. Refer to the indicator manual for information about load cell connections, setup and calibration. Note: When purchased as a Defender Series Scale, the base is already pre-wired to the 3000 Series Indicator. TABLE 1. SIX WIRE LOAD CELL CONNECTION. FUNCTION WIRE COLOR + Excitation Green Excitation Black + Signal Red Signal White + Sense Blue Sense Brown Shield Yellow Selecting the Location To ensure accuracy, proper performance and safety, locate and operate the base on a stable, level surface. Avoid locations with rapid temperature changes or excessive dust, air currents, vibrations, electromagnetic fields or heat. Level the base by adjusting the four leveling feet until the bubble in the level indicator (located at the rear of the base) is centered. A wrench may be needed to loosen the locking nut above each leveling foot. When the base is level, retighten the locking nuts up against the base to lock each foot into place. Note: Ensure that the base is level each time its location is changed. CORRECT INCORRECT

EN-2 Defender 3000 Series Base MAINTENANCE Cleaning The base components should be kept clean and free of excessive material build up. Damp cloth with water and a mild detergent may be used to wipe clean the external surfaces do not use acids, alkalis, strong solvents or abrasive materials and chemicals Troubleshooting Aside from installing components and leveling adjustments, the Defender Series Base does not require any other adjustments as shipped from the factory. Operational difficulties that may be encountered can often be traced to simple causes such as: Loose or incorrect wiring connections Obstructions to the base frame Unstable environments Incorrect calibration or setup of the indicator If the troubleshooting section does not resolve or describe your problem, contact your authorized Ohaus service agent. For service assistance or technical support in the United States call toll-free 1-800-526-0659 between 8:00 AM and 5:00 PM EST. An Ohaus product service specialist will be available to provide assistance. Outside the USA, please visit our web site, www.ohaus.com to locate the Ohaus office nearest you. TECHNICAL DATA Technical Specifications The technical data is valid under the following ambient conditions: Ambient temperature: 10ºC to +40 ºC Relative humidity: 10% to 90% relative humidity, non-condensing Height above sea level: Up to 4,000m Operability is assured at ambient temperature 10ºC to +40 ºC TABLE 2a. SPECIFICATIONS MODEL D30BR D60BR D60BL D150BL D150BX D300BX Capacity 30 kg 60 kg 60 kg 150 kg 150 kg 300 kg Maximum Resolution 6000d 6000d 6000d 7500d 7500d 6000d Pan Dimensions 305 x 355 x 75 mm 420 x 550 x 80 mm 500 x 650 x 90 mm Base Construction Safe Overload Capacity Repeatability (std. deviation) Stainless Steel platform with painted steel frame and rubber leveling feet 125% of capacity Linearity ±1d Load Cell Cable 2 m L x 6-wire 2.3 m L x 6-wire Load Cell Type Load Cell Excitation Load Cell Rated Output Load Cell Protection 1d 350 Ohm, aluminum, single point 5-15V DC/AC 2mV/V Net Weight 9 kg 16 kg 28 kg Shipping Weight 11 kg 19 kg 32 kg IP67

Defender 3000 Series Base EN-3 TABLE 2b. SPECIFICATIONS MODEL D15VR D30VR D60VR D60VL D150VL D150VX D300VX Capacity 15 kg 30 kg 60 kg 60 kg 150 kg 150 kg 300 kg Maximum Resolution 6000d 6000d 6000d 6000d 7500d 7500d 6000d Load Cell Capacity 30 kg 50 kg 100 kg 150 kg 300 kg 300 kg 500 kg Pan Dimensions 305 x 355 x 75 mm 420 x 550 x 80 mm 500 x 650 x 90 mm Base Construction Repeatability (std. deviation) Stainless Steel platform with stainless steel frame and rubber leveling feet Linearity ±1d Load Cell Cable 2 m L x 6-wire 2.3 m L x 6-wire Load Cell Type Load Cell Excitation Load Cell Rated Output Load Cell Protection Safe Overload Capacity 1d 350 Ohm, stainless steel, single point 5-15V DC/AC 2mV/V IP67 125% of capacity Net Weight 9 kg 21 kg 33 kg Shipping Weight 11 kg 24 kg 37 kg

EN-4 Drawings Defender 3000 Series Base Base Base shown with 3000 series indicator and column Figure 1. Defender Base Dimension Drawing. TABLE 3. DIMENSIONS. A B C D E Height of Pan to Depth Including Pan Depth Pan Width Height of Pan Surface of Table* Level Indicator D30BR, D60BR 355 mm 305 mm 123 mm 75 mm 380 mm D60BL, D150BL 550 mm 420 mm 136 mm 80 mm 575 mm D150BX, D300BX 650 mm 500 mm 143 mm 90 mm 675 mm D15VR, D30VR, D60VR 355 mm 305 mm 119 mm 75 mm 380 mm D60VL, D150VL 550 mm 420 mm 145 mm 80 mm 575 mm D150VX, D300VX 650 mm 500 mm 154 mm 90 mm 675 mm *For leveling purposes, the feet may be extended up to an additional 11mm. Description TABLE 4. ACCESSORIES. Part Number Column Kit, 35 cm painted steel 80251743 Column Kit, 70 cm painted steel 80251744 Column Kit, 35 cm stainless steel 80251745 Column Kit, 70 cm stainless steel 80251746

Defender 3000 Series Base Compliance EN-5 This product conforms to the EMC directive 2004/108/EC and the Low Voltage Directive 2006/95/EC. The complete declaration of Conformity is available online at www.ohaus.com. Disposal In conformance with the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside the EU, per their specific requirements. Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment. If you have any questions, please contact the responsible authority or the distributor from which you purchased this device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. For disposal instructions in Europe, refer to www.ohaus.com, choose your country then search for WEEE. Thank you for your contribution to environmental protection. ISO 9001 Registration In 1994, Ohaus Corporation, USA, was awarded a certificate of registration to ISO 9001 by Bureau Veritus Quality International (BVQI), confirming that the Ohaus quality management system is compliant with the ISO 9001 standard s requirements. On May 21, 2009, Ohaus Corporation, USA, was re-registered to the ISO 9001:2008 standard. LIMITED WARRANTY Ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period. During the warranty period Ohaus will repair, or, at its option, replace any component(s) that proves to be defective at no charge, provided that the product is returned, freight prepaid, to Ohaus. This warranty does not apply if the product has been damaged by accident or misuse, exposed to radioactive or corrosive materials, has foreign material penetrating to the inside of the product, or as a result of service or modification by other than Ohaus. In lieu of a properly returned warranty registration card, the warranty period shall begin on the date of shipment to the authorized dealer. No other express or implied warranty is given by Ohaus Corporation. Ohaus Corporation shall not be liable for any consequential damages. As warranty legislation differs from state to state and country to country, please contact Ohaus or your local Ohaus dealer for further details.

Ohaus Corporation 7 Campus Drive Suite 310 Parsippany, NJ 07054, USA Tel: (973) 377-9000 Fax: (973) 944-7177 With offices worldwide www.ohaus.com *80251065* P/N 80251065 D 2016 Ohaus Corporation, all rights reserved Printed in China