INTERFACE CONVERTER TraxBus TO EIA-RS232 / EIA-RS422 / EIA-RS485 SAFETY INFORMATION RECEIVING

Similar documents
Rack mounted telephone- and leased line modem for industrial applications

RS485 & RS422 Basics

PCS0100en Persy Control Services B.V. Netherlands

Eliminate Risk of Contention and Data Corruption in RS-485 Communications

Application Note 83 Fundamentals of RS 232 Serial Communications

SyncLink GT2/GT4 Serial Adapter

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Telephone- and leased line modem for industrial applications TD-36

RS-422 and RS-485 Application Note

Current Loop Application Note 1495

User Manual IC-485AI

Moxa TCC-100/100I User s Guide

is then retained absolutely without interruption.

Hardware Manual RM CANview Ethernet

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

ELCOMPONENT LTD. User Manual

Advanced Data Capture and Control Systems

Cable Specifications. T3 Trunk Cabling APPENDIX

TTL to RS232 Adapter User Guide

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

Modular I/O System Analog and Digital Interface Modules

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Application/Connection Examples

ZC-24DO CANopen I/O Module: 24 Digital Outputs

RS - SPM. Serial parallel translator module

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Duct Humidity Transmitter

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

T7560A,B,C Digital Wall Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

OPT SERIAL TO FIBER OPTIC CONVERTER

M-Bus Network Installation Notes

ABB Drives. User s Manual HTL Encoder Interface FEN-31

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Contents. Document information

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

F2400 FOM II Series Fiber Optic Modem Technical Manual

Manual Serial PCI Cards

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

RS-485 the Murphy Way!

RS-232 COMMUNICATIONS

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

ADACSNET USB Control Module

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

Interfacing Intel 8255x Fast Ethernet Controllers without Magnetics. Application Note (AP-438)

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

MechoNet TM Network Interface (MNI) Specification Submittal

SV 210 Signal Splitter and Incremental Converter for Sine-Cosine Encoders

MACTek Corporation. USB HART Interface. Users Manual

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

SP490/491 Full Duplex RS-485 Transceivers

Installation manual. Generator Paralleling Controller GPC multi-line C

BACnet Automation Interface Module (Network Version)

Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Documentation. M-Bus 130-mbx

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

Designing RS-485 Circuits

Modification of an AOR AR-8600 receiver to tune it with a ACECO FC-3002 frequency finder

Road Vehicles - Diagnostic Systems

KNX. Siemens Building Technologies HVAC Products. Synco Konnex bus. For devices of the Synco 700 / RXB ranges

Sending A/V Signals Over Twisted Pair Cables: An Introduction. What is A/V over twisted pair?... 2

+5 V Powered RS-232/RS-422 Transceiver AD7306

Provides one channel for Ethernet over existing

NC-12 Modbus Application

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

UniStream CPU-for-Panel

Physical Specifications (Custom design available.)

Overview of the Cisco 2500 Series Access Server

WEB log. Device connection plans

AN460 Using the P82B96 for bus interface

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

BroadBand PowerShield. User Manual

)454 6 %LECTRICAL CHARACTERISTICS FOR BALANCED DOUBLECURRENT INTERCHANGE CIRCUITS OPERATING AT DATA SIGNALLING RATES UP TO -BITS

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Industrial Multi-port Serial Cards

ELECTRICAL CHARACTERISTICS OF LOW VOLTAGE DIFFERENTIAL SIGNALING (LVDS) INTERFACE CIRCUITS PN May 2000

Product and functional description

OPTICAL FIBER repeaters/ isolators

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

ADM1TE 5/30A DIN rail single phase two wire energy meter

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Introduction. In this Self-study Programme we will explain to you the design and function of the CAN data bus. SSP 186/01

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

connecdim Gateway G1 Ethernet TCP/IP to DALI

Wiring RS-485 Networks

DK40 Datasheet & Hardware manual Version 2

Transcription:

INTERFACE CONVERTER TraxBus TO EIA-RS232 / EIA-RS422 / EIA-RS485 TraxBus is a dedicated fieldbus specifically designed to operate in very harsh environments where electrical noise generated by ignition transformers makes very difficult to operate for any standard physical layer. By installing the TraxInterface 3 it is possible to convert TraxBus to the following standard physical layers: EIA-RS232 EIA-RS422 EIA-RS485 The active version of TraxInterface 3 can drive up to 300 remote peripherals. The passive version can be used to interface standard peripherals (not equipped with TraxBus). A complete galvanic isolation is provided between filedbus and local interface. SAFETY INFORMATION Read and understand this manual before installing, operating, or servicing this unit. This unit must be installed according to this manual and local regulations. The drawings may show units without covers or safety shields to illustrate details. Disconnect power supply and follow all usual safety precautions before carrying out any operation on the device. Be sure to reinstall covers or shields before operating any devices. The device is not user serviceable, a faulty device must be put out of order and sent back for servicing. CONTRIVE manufactures products used as components in a wide variety of industrial systems and equipment. The selection and application of products remain the responsibility of the equipment manufacturer or end user. CONTRIVE accepts no responsibility for the way its products are incorporated into the final system design. All systems or equipment designed to incorporate a product manufactured by CONTRIVE must be supplied to the end user with appropriate warnings and instructions as to the safe use and operation of that part. Any warnings provided by CONTRIVE must be promptly provided to the end user. CONTRIVE guarantees for two years from the date of manufacture of its product to replace, or, at its option, to repair any product or part thereof (except fuses and with some limitations for tubes and photocells) which is found defective in material or workmanship or which otherwise fails to conform to the description of its sales order. CONTRIVE makes no warranty of merchantability or any other warranty express or implied. CONTRIVE assumes no liability for any personal injury, property damage, losses, or claims arising from misapplication of its products. Please perform the following tasks after receiving the TraxInterface 3 : Inspect the unit for damage. If the unit appears damaged upon receipt, contact the shipper immediately. Verify receipt of the correct unit by checking the label (bottom side). If you have received the wrong model or the device does not function properly,contact your supplier. RECEIVING 2000 CONTRIVE B1300.EN 0211 1 www.contrive.it

POWER SUPPLY TERMINALS A D EIA-RS422 / EIA-RS485 TERMINALS POWER SUPPLY FUSE 2,5A QUICKBLOW B E EIA-RS232 SubD 9 pin FEMALE SOCKET ACTIVE TraxBus TERMINALS C F PASSIVE TraxBus TERMINALS WIRING DIAGRAM 01 POWER SUPPLY 02 POWER SUPPLY 10 ACTIVE TRAXBUS NEGATIVE (ACTIVE VERSION ONLY) 11 ACTIVE TRAXBUS - NEGATIVE (ACTIVE VERSION ONLY) 12 ACTIVE TRAXBUS - POSITIVE (ACTIVE VERSION ONLY) 13 ACTIVE TRAXBUS - POSITIVE (ACTIVE VERSION ONLY) 20 PASSIVE TRAXBUS NEGATIVE (PASSIVE VERSION ONLY) 21 PASSIVE TRAXBUS POSITIVE (PASSIVE VERSION ONLY) 30 EIA-RS422 A 31 EIA-RS422 B 32 GROUND 33 EIA-RS422 Z OR EIA-RS485 B 34 EIA-RS422 Y OR EIA-RS485 A EIA-RS232 FEMALE CONNECTOR (232 VERSION ONLY) USE POWER, SIGNAL AND CONTROL CABLE SUITABLE FOR THE TYPE OF OPERATION AND COMPLYING WITH ALL REGULATIONS DO NOT ROUTE FILEDBUS CABLE TOGETHER WITH FREQUENCY CONVERTER CABLES OR CABLES EMITTING STRONG FIELDS ALL ELECTRONIC SYSTEMS MUST BE SUPPLIED BY A DEDICATED TRANSFORMER IN A TN-S EARTHING SYSTEM EIA-RS485 AND EIA-RS422 DATA LINE B (Z) IS POSITIVE WITH RESPECT TO DATA LINE A (Y) WHEN TRAXINTERFACE IS TRANSMITTING 1. INTERNAL 10KΩ RESISTORS ARE PROVIDED TO GUARANTEE THE BIASING. WHEN TERMINATION RESISTOR ARE USED, ADDITIONAL BIASING COULD BE REQUIRED TO GUARANTEE THE MINIMUM DIFFERENTIAL VOLTAGE OF 200 mv ACROSS INPUTS. 2000 CONTRIVE B1300.EN 0211 2 www.contrive.it

TraxBus NETWORKS Following "ISO Basic Reference Model for Open System Interconnection" (ISO/OSI) TraxBus is the physical part of the connection (Physical Layer). TraxBus features high electromagnetic noise immunity and great wiring simplicity, also using busbar trunkets. Possible application are in hostile industrial environments where other standard networks doesn t work. Devices with embedded TraxBus uses a set of ASCII command (protocol). Detailed information on command set are available on respective device technical literature. Live connection and/or disconnection while the communication is running are allowed, though a short break in the data flow may result from this operation. A short-circuit on the TraxBus while the unit is transmitting can damage the TraxInterface 3, a limited time shortcircuit while the unit is in idle mode (receiving) is tolerated. LINE BUS RING STAR TREE MESH TraxBus lines can be wired in any form: star, ring, line or mixed but signal line must be wired separately from power lines. Do not use shielded cables. Do not use multicore cables or limit the usage to short stubs. Use conventional single wires or busbar trunkets to interconnect all peripherals. If some shielding is absolutely necessary it is always possible to put twisted pairs in a conduit or grounded metal tube, without packing too many conductors together. It's very important to understand that the only precaution for good wiring are line capacitance and resistance. Excessive resistance will cancel data flow from MASTER to peripherals. Excessive capacitance will cancel data flow from peripherals to MASTER. Overall bus capacity Loop resistance Core cross-section 100 nf maximum 60 Ω maximum 1 mm 2 minimum Some useful information Up to 300 physical units can be connected to each TraxInterface 3. Network topology, cables characteristic and other environmental conditions could reduce the number of driven units. TraxBus is a master/slave system, thus only 1 master is allowed. The master can drive one or more TraxInterface 3 (using EIA-RS422 or EIA-RS485 multidrop version). When TraxBus is exposed to severe EMC condition, it could be necessary to provide overvoltage protections on both power supply and data lines. The power supply current is depending from the number of remote units, as a general rule consider 200 ma + 10 ma per each connected peripheral (e.g.: having 200 units connected on a single bus the external power supply must be capable to deliver 200 + (10*200) = 2200 ma @ 24Vac). Make sure there is adequate ventilation around the heatsink located on the top of the unit. 2000 CONTRIVE B1300.EN 0211 3 www.contrive.it

TraxInterface3.232.A EIA-RS-232 interface is the easiest way to implement TraxBus when the number of remote peripherals and the system architecture doesn t require more than 1 TraxBus line. In the figure below, a single TraxInterface 3 is driving several units deployed on a busbar trunket used for both the main power supply and the communication bus. This solution can simplify the installation and maintenance. Since the stubs from the units to the busbar socket are made using multi-core cable (usually phase, neutral, ground, communication positive and negative) it s very important to keep those cables as short as possible. A single master controller is connected to SubD 9 female socket. The cable coming from the (DTE Data Terminal Equipment) master must be terminated with a SubD male socket (see below). TraxInterface 3 is DCE (Date Communication Equipment). Only RxD, TxD and GND signal are required. FROM MASTER CONTROLLER MAIN POWER SUPPLY TraxInterface 3 POWER SUPPLY 2000 CONTRIVE B1401.EN 0211 4 www.contrive.it

TraxInterface3.485.A EIA-RS485 interface can be used to drive one or more TraxBus lines. Communication line coming from the master must be wired at terminals 33 and 34, signal ground and shield to terminal 32, leaving terminals 30 and 31 unconnected. At higher baud rates and long distance could be necessary to install termination resistors (typically 120 Ω) at both ends. Since TraxInterface 3 is provided with high value fail safe resistors (10 kω), additional biasing could be required. STUB n STUB 1 RT FROM MASTER CONTROLLER 2000 CONTRIVE B1401.EN 0211 5 www.contrive.it

TraxInterface3.422.A EIA-RS422 is a Full Duplex interface, TraxBus handles Half Duplex only, thus there is no practical reason to adopt such interface that requires additional wires. TraxInterface 3 can handle multiple receivers/transmitters in a multidrop configuration, following the same rules as EIA-RS485. STUB n STUB 1 RT FROM MASTER CONTROLLER The recommended arrangement of the wires is as a connected series of point-to-point (multidrop) nodes, line or bus topology only. Ideally, the two ends of the net will have a termination resistor [RT] connected across the two wires. How can I tell if I'll need termination on my RS485/RS422 connections? Line terminations are not needed if the duration of a single bit transmitted is greater than at least 10 times the time that the signal takes to travel down the line. Assuming 1200 m network length and 9600 bit/s: BitTx = duration of a single bit transmitted tt = time that the signal takes to travel down the line termination l = network length c = speed of light Propagation speed in an electrical cable is about 66% the speed of light No termination required, since it s verified that: Termination adds to the complexity of the installation and can potentially load down drivers, we recommend only using termination if it's required. No more than 2 termination resistors should be used, one at each end of the transmission line. 2000 CONTRIVE B1401.EN 0211 6 www.contrive.it

TraxInterface3.xxx.P Thirds party products can be connected to TraxBus by means of PASSIVE TraxInterface 3. Depending on selected interface, the local peripheral can use EIA-RS232, EIA-RS422 or EIA-RS485. From local interface it will be possible to read all the network data traffic. Specific peripheral must be programmed to handle the communication and transmit on the network only when is required. TO EIA-RS232 PERIPHERAL BUSBAR TRUNKET TraxBus DEVICE Ordering Guide Both EIA-RS422 an EIA-RS485 are available on the same interface option [485]. SubD 9 pin is available on all types but operative on [232] version only. Passive version requires a power supply current of 200 ma approx @ 24Vac. TraxInterface 3 232 A INTERFACE EIA-RS232 = 232 EIA-RS422/485 = 485 BUS ACTIVE = A PASSIVE = P 2000 CONTRIVE B1401.EN 0211 7 www.contrive.it

TECHNICAL DATA POWER SUPPLY VOLTAGE 24 VAC / 30VDC ±10% FREQUENCY 0 1000 Hz LINE FUSE POWER CONSUMPTION POWER DISSIPATION TERMINALS 2,5 A QUICKBLOW - 5x20mm 5 90 VA 1 300 PERIPHERALS 3 30 VA 1 300 PERIPHERALS 2 x 2,5 mm 2 (AWG22-12) REMOVABLE ENVIRONMENT OPERATING TEMPERATURE 0 60 C STORAGE TEMPERATURE -20 80 C PROTECTION CLASS (EN 69529) RELATIVE HUMIDITY MOUNTING POSITION IP20 30 90% NON CONDENSING ANY EIA-TIA RS232 DATA FORMAT SERIAL ASYNCHRONOUS UART/NRZ DEVICE TYPE DCE SIGNAL 5=GND, 3=TxD, 2=RxD SEEN FROM DTE ISOLATION TEST VOLTAGE 2500 V @ 50 Hz, 1 minute INSULATION VOLTAGE 300 V RMS MAX EIA-TIA RS422/485 MULTIDROP UNITS 32 MAX LINE LENGTH 1000 m MAX TERMINALS 5 x 2,5 mm 2 (AWG22-12) REMOVABLE ISOLATION TEST VOLTAGE 2500 V @ 50 Hz, 1 minute INSULATION VOLTAGE 300 V RMS MAX BUS VOLTAGE BAUD RATE PASSIVE TraxBus INTERFACE 30 Vdc MAX 38400 MAX EIA/TIA-232 Interface Between Data Terminal Equipment and Data Circuit Terminating Equipment Employing Serial Binary Data Interchange V.28 Electrical characteristics for unbalanced doublecurrent interchange circuits ACTIVE TraxBus INTERFACE TYPE ASYNCHRONOUS MULTIDROP HALF DUPLEX ALLOWABLE PERIPHERALS 300 MAX BAUD RATE 38400 MAX BUS VOLTAGE 24 VDC MAX BUS CURRENT 2,5 A MAX ALLOWABLE VOLTAGE DROPOUT 3 V MAX ALLOWABLE LINE CAPACITANCE 100 nf MAX TERMINALS 4 x 2,5 mm 2 (AWG22-12) REMOVABLE EIA/TIA-485 Electrical Characteristics of Generators and Receivers for Use in Balanced Digital Multipoint Systems TIA/EIA-422 Electrical Characteristics of Balanced Voltage Digital Interface Circuits V.11 Electrical characteristics for balanced doublecurrent interchange circuits operating at data signalling rates up to 10 Mbit/s EIA TIA Electronic Industries Alliance Telecommunications Industry Association CONTRIVE S.r.l. I-24040 SUISIO (Bergamo) via Enrico Fermi 18 ANY ILLUSTRATIONS, PHOTOGRAPHS, OR EXAMPLES USED IN THIS MANUAL ARE PROVIDED AS EXAMPLES ONLY AND MAY NOT APPLY TO ALL PRODUCTS TO WHICH THIS MANUAL IS APPLICABLE. THE PRODUCTS AND SPECIFICATIONS DESCRIBED IN THIS MANUAL OR THE CONTENT AND PRESENTATION OF THE MANUAL MAY BE CHANGED WITHOUT NOTICE TO IMPROVE THE PRODUCT AND/OR THE MANUAL. PRODUCT NAMES, CORPORATE NAMES, OR TITLES USED WITHIN THIS DOCUMENT MAY BE TRADEMARKS OR REGISTERED TRADEMARKS OF OTHER COMPANIES, AND ARE MENTIONED ONLY IN AN EXPLANATORY MANNER TO THE READERS BENEFIT, AND WITHOUT INTENTION TO INFRINGE. WHILE EVERY EFFORT HAS BEEN MADE TO MAKE SURE THE INFORMATION IN THIS DOCUMENT IS CORRECT, CONTRIVE CAN NOT BE LIABLE FOR ANY DAMAGES WHATSOEVER FOR LOSS RELATING TO THIS DOCUMENT. COPYRIGHT 2010 CONTRIVE SRL ITALY. ALL RIGHT RESERVED. 2000 CONTRIVE B1401.EN 0211 8 www.contrive.it