PCI3 Communication Adapter Installation Guide

Similar documents
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

User Manual IC-485AI

xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

IFS SP-PoE Splitter User Manual

Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server

Pan Dacom. Nets work together. SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s ( A, A) Manual

1 Port FTDI USB to RS232 Null Modem Adapter

C24-CAMANL Video Server/Encoder

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Versatility, reliability and expandability are the three main features that make the N-1000 one of the most popular access control panels ever.

USB Dual Handset Adapter for Nortel 1100-Series IP Phones

Disclaimers. Important Notice

4 Port VGA Video Audio Switch with RS232 control

InnoMedia ESBC B. Quick Install Guide. 1

InnoMedia ESBC B. Quick Install Guide. 1

Power Over Ethernet Adapters POE101

xpico Wi-Fi Embedded Device Server Evaluation Board Quick Start Guide

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

StructureScan HD Module. Installation Guide ENGLISH

DMX USB PRO. User Manual.

3.5 mm Audio Jack. Manual innoxplore ix B24 A2DP Stereo Bluetooth Audio Adapter Dongle 3.5mm Audio Jack [ix B24] Contents

RC8021 Indoor Camera Installation Guide

TD-8610/TD-8610B External ADSL2+ MODEM

USB to RS-422/485 Serial Adapter

FCC COMPLIANCE STATEMENT

10/100/1000 Base-T to Gigabit Fiber Media Converter

USB-to-Serial RS-232 Hub USB-to-Serial RS-422/485 Hub USER MANUAL UC2322 / UC2324 / UC4852 / UC4854

HDMI Matrix Switch USER MANUAL VM0404H

User manual Compact Web PLC WP240 series IEC-line

CONSOLE REMOTE I /O AC 9V

485USBTB-2W & 485USBTB-4W

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Wireless Travel Mouse with 5-Buttons User Manual

Advanced Data Capture and Control Systems

DSX Master Communications

Customer Pole Display SERIES 8035

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

USB 2.0 to 10/100Mbps Ethernet Adapter UE User Manual

Serial ATA Hard Drive Docking Station

VDSL Ethernet LAN Extender

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

XPort Universal Demo Board User Guide

USB/VGA Cat 5 UTP Console Extender

USB Plus+ RFID Reader Setup Guide

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

USB-RS232 Converter USB-RS422/485 Converter. User's Manual

1 Port RS232 Serial over IP Device Server

SATA and SAS Hard Drive Backplane

QUICK START GUIDE CX-MC200LE-VZ

HSG Engineering Tech Bulletin

Serial to Bluetooth Adapter

8-Port HDMI Switch USER MANUAL VS0801H

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

AXIS 291 1U Video Server Rack Installation Guide

RJ11 RS-232 Interface

TUNABLE ANTENNAFIER LT/DT SERIES INSTALLATION INSTRUCTIONS

2 Port RS232/422/485 PCI Serial Adapter Card ESD Protection

ES-3305P V2 / ES-3308P V2. Quick Installation Guide / v1.0

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

2/4/8 Port USB to Serial Adapter Hub with COM Retention

ADACSNET USB Control Module

RedTitan Print2PC Parallel Port Converter. Quick Installation Guide - US English. Product contents. Introduction. PC System Requirements

USB Serial Adapter ICUSB232SM3. Instruction Manual. 1-Port 3ft USB to RS232 DB9 Serial Adapter Cable

Moxa TCC-100/100I User s Guide

Edgeport USB EXPANSION MODULES. Installation Guide. Models: Edgeport/1. Edgeport/22c. Edgeport/4r. Edgeport/8r.

Professional USB to Serial Adapter Hub with COM Retention

Dual Ports Serial PC Card User Manual

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

Troubleshooting and Diagnostics

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Skyus 3G. Quick Start Guide Verizon

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

DVI to Mini DisplayPort Converter. EXT-DVI-2-MDP User Manual

mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start

SolarEdge Export Limitation Guide

USB-to-CAN V2 compact

DT105X / PB105 Series

s!nus-elektrotechnikai bt. Industrial IT & Automation

OC810 Outdoor Camera Setup Guide

WEB log. Device connection plans

MoCA Adapter MC1001 v2 Installation Guide

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

9,'(2 #6(3$5$725 8VHU V#0DQXDO

s!nus-elektrotechnikai bt. Industrial IT & Automation

OC810 Outdoor Camera Installation Guide

BPM Series. Metered Rack Mount PDUs. Quick Start Guide. Models Covered:

Customer VFD pole display JP-8034 USB OPERATION MANUAL

Wave/PC Interactive System USB Adapter Kit. Installation Guide

VM0808H HDMI Matrix Switch RS-232 Control Tool V User Manual

Bluetooth to Serial Adapter

PRO-2200 Intelligent Controller Installation Manual Part Number: PRO22IC

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

Comtrol Cable User Guide

Transcription:

PCI3 Communication Adapter Installation Guide Date: July 7, 2008 Document 7-901041 2008 Honeywell Inc. All rights reserved. Revision C

Copyright 2008 Honeywell International. All rights reserved. PCI3 is a registered trademark of Honeywell, Inc. All other product and brand names are the service marks, trademarks, registered trademarks, or registered service marks of their respective owners. Printed in the United States of America. Honeywell reserves the right to change any information in this document at any time without prior notice.

Overview PCI3 Communications Adapter Installation Guide The PCI3 Communications Adapter functions as the interface between a host computer s RS232 port and one or more Honeywell access control panels connected on an RS485 multi-drop line. The adapter translates the PC s CIDD protocol to the proprietary RS485 protocol. The PCI3 can be used to replace a PW5K1CVT1 or a PRO22CVT1; however, the PCI3 does not have optical isolation as the others do. This isolation may be useful in some applications. The PCI3 also replaces the N-485-PCI-2, N-485-HUB-2, and N485PCI2L adapters, and it adds the following features: Variable communications speed up to 115.2 Kbps on the RS232 port. Capacity to add future technology enhancements without legacy limitations. Time with seconds in true reports. Flash upgrades of NS2 and NS2P access control panels. The PCI3 operates as the arbitrator of the drop line, polling each API for its information, and determining its status. If an API or panel drops out, the PCI notifies the host. If communication to the host is lost, the PCI sends a buffer command to the panels for them to buffer events (when configured with WIN-PAK version 1.17 or higher using the RS232 ACK/ NAK option, where DIP switch 5 is in the UP position). Communications with the host can only be detected when the PCI3 is running in the ACK/ NAK mode of operation. When access control system configurations include an Ethernet-to- RS232 conversion product instead of a direct host connection, the PCI s RS232 port operates the same as with a direct connection. Document 7-901041, Revision C 1 PCI3 Communications Adapter 2008 Honeywell, Inc. Installation Guide

Installation 4.625 2.845 0.190 (2 PLCS.) 5.130 Dimensions (H x W x D) 2.845 in. x 5.130 in. x 1.107 in.(7.226 cm x 13.030 cm x 2.812 cm) Mounting Holes Distance 4.625 in. (11.748 cm) Diameter 0.190 in. (0.483 cm) Note: The mounting holes are on the enclosure center line. Allow at least 2 (50.8mm) between connectors and ceiling for wiring clearance. PCI3 Communications Adapter 2 Document 7-901041, Revision C Installation Guide 2008 Honeywell, Inc.

Setting the DIP Switches Setting the DIP Switches PCI3 Communications Adapter Installation Guide The PCI3 communications adapter has eight Dual In-line Package (DIP) switches. For the DIP switch setting to be recognized, the PCI3 must be power cycled (except for switch 1). The switches are numbered from left to right, as shown: ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 DIP switches Document 7-901041, Revision C 3 PCI3 Communications Adapter 2008 Honeywell, Inc. Installation Guide

Use the following table to set switches 1-5: Switch Name Instruction 1 End of Line (EOL) Up (No EOL) PCI3 is NOT wired at either end of the 485 drop line. Down (EOL) PCI3 is wired at either end of the 485 drop line. 2 NORMAL Up Allows normal PCI3 operation. Down Enables the PCI3 to receive a firmware flash upgrade from the host. In this mode the PCI3 will NOT perform its normal operating function.(download Mode). When doing a download, Switch 4 should be up. 3 Pass Thru Up Configures the PCI3 for operations with the N-1000 Series, PW-2000 series, NS2, and NS2P panels. Down Configures the PCI3 for operations with the PW-5000, PRO-2200, PW-6000, PW-3000, and Star series panels (Pass Thru Mode). 4 Hub Up A direct PCI3 connection to the host PC. Down Direct PCI3 connection to a dialup modem to operate as a HUB. PCI3 Communications Adapter 4 Document 7-901041, Revision C Installation Guide 2008 Honeywell, Inc.

5 ACK/ NACK Up Enable ACK/NAK protocol when communicating with the host. Down Disable ACK/NAK protocol when communicating with the host. Use the following table to set switches 6-8. Note that baud rates apply to the RS232 port: Baud Rate Switch 6 Switch 7 Switch 8 1200 Down Down Down 1200 Down Down Up 2400 Down Up Down 9600 Down Up Up 19200 (Default) Up Down Down 38400 Up Down Up 57600 Up Up Down 115200 Up Up Up Note that if you are using dial-up/modem connections, a baud rate of 19200 is recommended. All RS232 communication uses 8 bit data, 1 stop bit, and no parity. Document 7-901041, Revision C 5 PCI3 Communications Adapter 2008 Honeywell, Inc. Installation Guide

LED Status Indicators The following illustration identifies the RS232 and RS485 LEDs on the PCI3: ON 1 2 3 4 5 6 7 8 Use the following to reference LED function and operation: RS485 LEDs RXTX RS485 Green data is being received by the PCI3. Red data is being transmitted by the PCI3. STATUS S RXTX RS232 PCI3 Communications Adapter 6 Document 7-901041, Revision C Installation Guide 2008 Honeywell, Inc.

RS232 LEDs PCI3 Communications Adapter Installation Guide Green Indicates that the PCI3 is receiving data. Red Indicates that the PCI3 is transmitting data. Yellow (STATUS LED) Indicates the STATUS of the PCI3. DIP switch 3 is UP, PCI3 Operation Mode Pulses once a second the PCI3 is trying to detect the presence of a panel on the RS485 port. It keeps pulsing until it establishes contact with at least one panel. Once communications are running on the RS485 port, the LED is on continuously. On the correct baud rate has been detected and both ports are running. Off no power. DIP switch 3 is DOWN, Pass Thru Mode Pulses once a second 30 seconds of inactivity on both ports. Off no panel detected on the 485 port. On activity on both communication ports. Document 7-901041, Revision C 7 PCI3 Communications Adapter 2008 Honeywell, Inc. Installation Guide

RJ45 Connector Pinouts (RS232) RJ45 Function 1 N/C 2 Connected to pin 7 in PCI3 3 Circuit common 4 TX out of PCI3 5 RX into PCI3 6 N/C 7 Connected to pin 2 (this is an RTS/CTS loopback function) 8 N/C PCI3 Communications Adapter 8 Document 7-901041, Revision C Installation Guide 2008 Honeywell, Inc.

Cable Connections PCI3 Communications Adapter Installation Guide The figure below identifies the PCI3 cable connections: 9 VDC 100mA POWER (8.1V to 13.8VDC operating range) RS232 RS485+ (A) RS485- (B) RS485 COM Document 7-901041, Revision C 9 PCI3 Communications Adapter 2008 Honeywell, Inc. Installation Guide

Cable Specifications The following table provides the PCI3 adapter cable specifications: Cable Description Length Part Numbers RS485 COM, RS485 -, RS485 + 24 AWG, 2 twisted pairs with shield, 120 ohm, 23 pf Up to 4000 feet NCP2441-TN RS232 Use RJ45 to DB9 for PC connection. Use RJ45 to DB25M for modem connection or NLANSRLU1. Use RJ45 to DB25F null modem for LANSRL100 connection. 7 feet 50 feet (max) PCI3CBLKT CBL50 9 VDC Power USB to Serial 9 VDC, Class 2 with center-positive 2mm connector. Optional accessory for USB connection (not included) 6 feet PCI3PSKIT 16 USB2SER PCI3 Communications Adapter 10 Document 7-901041, Revision C Installation Guide 2008 Honeywell, Inc.

An adapter plug kit is included. The kit contains power supply plugs for United States, European Union, United Kingdom, and Australian outlets. Document 7-901041, Revision C 11 PCI3 Communications Adapter 2008 Honeywell, Inc. Installation Guide

Typical Wiring Diagrams for Control Panels Figure 1 Typical Wiring Diagram for a Generic Control Panel with DB9 PC WITH DB-9 COMM PORT CONTROL PANEL Terminal 1 Terminal 2 Terminal 3 SHIELD 7 CABLE WITH RJ45 TERMINALS ON BOTH ENDS. INSERT EITHER END IN PCI3 TERMINAL. ATTACH OTHER TO RJ45-TO-DB9 CONVERTER AND INSERT IN PC COMM PORT. 9V DC POWER SUPPLY Optional Common Shield Cable RS485 + RS485 - RS485 COM RS232 PCI3 9VDC POWER 100 ma PCI3 Communications Adapter 12 Document 7-901041, Revision C Installation Guide 2008 Honeywell, Inc.

Figure 2 Typical Wiring Diagram for a Generic Control Panel with USB PC WITH USB COMM PORT CONTROL PANEL Terminal 1 Terminal 2 Terminal 3 USB2SER SERIAL- TO-USB CABLE SHIELD 7 CABLE WITH RJ45 TERMINALS ON BOTH ENDS. INSERT EITHER END IN PCI3 TERMINAL. ATTACH OTHER TO RJ45-TO-DB9 CONNECTOR. CONNECT DB9 ADAPTER INTO THE DB9 END OF THE USB CONVERTER. PLUG USB CONNECTOR INTO PC. 9V DC POWER SUPPLY Optional Common Shield Cable RS485 + RS485 - RS485 COM RS232 PCI3 9VDC POWER 100 ma Document 7-901041, Revision C 13 PCI3 Communications Adapter 2008 Honeywell, Inc. Installation Guide

Figure 3 Typical Wiring Diagram for a Generic Control Panel with DB25 MODEM WITH DB25 COMM PORT or NLANSRLU1 CONTROL PANEL Terminal 1 Terminal 2 Terminal 3 SHIELD 7 CABLE WITH RJ45 TERMINALS ON BOTH ENDS. INSERT EITHER END IN PCI3 TERMINAL. ATTACH OTHER TO RJ45-TO-DB25 CONVERTER AND INSERT IN MODEM PORT. 9V DC POWER SUPPLY Optional Common Shield Cable RS485 + RS485 - RS485 COM RS232 9VDC POWER 100 ma PCI3 HUB mode Note: Refer to appropriate panel installation manual for panel wiring details. PCI3 Communications Adapter 14 Document 7-901041, Revision C Installation Guide 2008 Honeywell, Inc.

Figure 4 Typical Wiring Diagram for LANSRL100 PCI3 Communications Adapter Installation Guide LANSRL100 CONTROL PANEL Terminal 1 Terminal 2 Terminal 3 SHIELD 7 CABLE WITH RJ45 TERMINALS ON BOTH ENDS. INSERT EITHER END IN PCI3 TERMINAL. ATTACH OTHER TO RJ45-TO-DB25F NULL MODEM CONVERTER INSERT IN LANSRLU1 PORT. 9V DC POWER SUPPLY Optional Common Shield Cable RS485 + RS485 - RS485 COM RS232 PCI3 9VDC POWER 100 ma Document 7-901041, Revision C 15 PCI3 Communications Adapter 2008 Honeywell, Inc. Installation Guide

Control Panel PCI3 Terminals RS-485 + RS-485- Common Shield Cable N-1000-III TB7-2 TB7-3 N/C TB9-12 N-1000-III-X TB7-2 TB7-3 N/C TB9-12 N-1000-IV TB7-2 TB7-3 N/C TB9-12 N-1000-IV-X TB7-2 TB7-3 N/C TB9-12 PW-2000-III TB7-2 TB7-3 N/C TB9-12 PW-2000-III-X TB7-2 TB7-3 N/C TB9-12 PW-2000-IV TB7-2 TB7-3 N/C TB9-12 PW-2000-IV-X TB7-2 TB7-3 N/C TB9-12 PW5K1IC PORT 1 TR+ PORT 1 TR- PORT 1 GND EARTH PW3K1IC PORT 1 TR+ PORT 1 TR- PORT 1 GND EARTH PW6K1IC PORT 1 TR+ PORT 1 TR- N/C PORT 1 GND PRO22IC PORT 1 TR+ PORT 1 TR- PORT 1 GND EARTH NS2 TB9-1 TB9-2 TB9-3 EARTH NS2+ TB9-1 TB9-2 TB9-3 EARTH N-485-API-2 TB1-5 TB1-3 N/C TB1-12 PCI3 Communications Adapter 16 Document 7-901041, Revision C Installation Guide 2008 Honeywell, Inc.

Pin Assignments 14 1 CONNECTOR RJ45 2 3 4 5 7 8 1 4 7 2 3 5 DCE MODEM DB25M CONNECTOR 6 20 CONNECTOR RJ45 25 DCE MODEM DB25M CONNECTOR 13 (NOTE:THE PIN # NOT SHOWN ARE NOT CONNECTED) 1 6 CONNECTOR RJ45 2 3 4 5 7 8 CONNECTOR RJ45 1 14 5 DTE COMPUTER DB9F CONNECTOR 9 1 8 5 2 3 7 DTE COMPUTER DB9F CONNECTOR (NOTE:THE PIN # NOT SHOWN ARE NOT CONNECTED) CONNECTOR RJ45 2 3 4 5 7 8 1 4 7 3 2 5 6 20 DB25F CONNECTOR CONNECTOR RJ45 25 DB25F CONNECTOR 13 Document 7-901041, Revision C 17 PCI3 Communications Adapter 2008 Honeywell, Inc. Installation Guide

PCI3 Power-Up Sequence 1. At power-up the PCI3 starts looking for active panels. It begins trying to communicate with panel address #1 at 38.4K baud. 2. If the panel answers, the PCI3 will look for panel #2, and all other panels, at 38.4K baud. After finding the first panel, it sends a message out of the RS232 port to the host which includes the PCI3 firmware version number. Until it finds the first panel, no RS232 communications are attempted. 3. If the PCI3 does not connect with panel #1 at 38.4K baud, it tries again at 57.6K, then 76.8K, and finally at 115.2K baud. 4. If the PCI3 does not connect with panel #1 at any of those baud rates, it tries the same sequence of baud rates for panel #2. The PCI3 will keep trying to connect with panels until it reaches panel address #31. It then starts over with panel #1. 5. Once it does find a panel that responds, it won't change the baud rate. DEBUG Hints If the RS485 transmit LED is constantly flickering but no other communication LEDs are active, the PCI3 is searching for a panel and has not found one. If the panels are attached, the RS485 +/- wires are probably crossed. Make sure that any modem setup has the Echo feature turned off. The default modem string when the PCI3 is configured for a Hub is 'AT E0 V1 &C0 &D0 S0=1 &W0 &W1'. This modem string is sent when power is cycled to the PCI3-Hub or on a disconnect from the host PC. PCI3 Communications Adapter 18 Document 7-901041, Revision C Installation Guide 2008 Honeywell, Inc.

If the BAD CRC counter is incrementing every minute or so, it may mean that two or more panels have the same panel address. The PCI3 has the RS485 bias resistors always attached. No other communication bias resistors are needed (but can be included). The PCI3 EOL network is AC-coupled. There is no resistance difference between the RS485 +/- terminals if the PCI3 EOL network is on or off. PCI3 Voltage Test If no other panels are attached, the RS485 voltage at the PCI3 is +3.3V for the RS485+ and 0V for the RS485-. Note that if the PCI3 is attempting communications, both voltages will be in the 1.5-2.0 VDC range for a typical voltmeter as the signals swing between 3.3V and 0V. If an NS2 or N1000 is connected to the RS485 bus, the voltages will be higher if they have their bias network connected, up to a maximum reading of 5V. Document 7-901041, Revision C 19 PCI3 Communications Adapter 2008 Honeywell, Inc. Installation Guide

FCC Regulations This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Re-orient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual. Unauthorized changes or modifications could void the user s authority to operate the equipment. PCI3 Communications Adapter 20 Document 7-901041, Revision C Installation Guide 2008 Honeywell, Inc.

Honeywell Access Systems 135 West Forest Hill Avenue, Oak Creek, WI 53154 www.honeywellaccess.com Ph (800) 323-4576 Ph (414) 766-1700 Fax (414) 766-1798 European Office Boblingerstrasse 17, 71101 Schonaich, Germany Ph +49 7031637782 Fax +49 7031637769 7-901041 Rev C 2008 Honeywell, Inc. All rights reserved. Specifications subject to change without notice.