Always insist on original spare parts being fitted.

Similar documents
English. Please read before use. Chase. Chase 2. Select 1/8. Program. Chase 3. Select 9/16. Chase 4. Midi / Rec. Chase 5. Auto / Del.

POWER INPUT: AC 230V~50Hz F6.3A 250V 5x20mm OUTPUT: 1.5A / Channel, 6A / Total. FUSES CH2

English USER'S MANUAL. Please read before use

User Instructions. Elation Professional R 4295 Charter Street Los Angeles CA PRO BAR 4 CAUTION!

USER'S MANUAL. Elation Professional R 4295 Charter Street Los Angeles CA

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

Installation and User Guide

STAGE SETTER-8. User Instructions. Elation Professional

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

19 LED Tube Controller ORDERCODE 41003

SCD Server. SCD Server Pro

Applied Electronics. Commercial Dimming System UPDATE NOTICE

50W/100W LED Zoom User Manual

APOLLO Plus PORTABLE DIMMER SERIES

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

User Instructions. Elation Professional R 4295 Charter Street Los Angeles CA

MANUAL ENGLISH. Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

Product Name LED Panel light Product Models

Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

LED BAR 126 / 252 RGB. Owner s Manual LED BAR RGB

DDP-405 USER'S MANUAL

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

User manual DMX CONTROL 512. Table of contents

USER MANUAL. Issue 3 - December Manual Stock No Software Version 3.0 Zero 88 Lighting Ltd. 2003

Congratulations! Thank you!

VX 2400 Dimmer User's Manual

K E E P E TH T I H S I MA M N A U N A U L A FO F R

FT-100 Fire Training Fog Machine User Manual English

DAB+ / FM Tuner Model: TU-201

MANUAL PC1000R

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

User Manual THR840DUK Digital Thermostat

PART 1 PRODUCT (GENERAL)...1.

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

TG24 / 48 LIGHTING CONTROLLER

PD 100A. Printing data system

Owner s Manual channel amplifier

Four Way 220 LED DMX Moonflower

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

Digital Dimmer. User s Manual. Version 1.40

LED Matrix Blinder 5x5 DMX blinder. user manual

DMX512 TO 0-10 VOLT ANALOG CONVERTER OWNERS MANUAL

DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

K E E P E TH T I H S I MA M N A U N A U L A FO F R

LEDPAR64 USER MANUAL

ORDER DIRECTLY TODAY AT: or CALL TOLL FREE Foglio di Istruzioni Owner s manual IMPERIAL. GR 0035 Xenon 4000

MultiDim MKII V.2 ORDERCODE 50386

Snapshot. LEDrain 38 USER MANUAL. Ok on Dimmer. Outdoor OK. Sound Activated. DMX/Master/Slave. 115V/230V Switch. Replaceable Fuse.

Drayton Digistat +2RF/+3RF

Modular I/O System Analog and Digital Interface Modules

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Research RF Sputtering Packages

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

PART 1 PRODUCT (GENERAL)...1.

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

MIDI USER INSTRUCTIONS. Elation Professional 4295 Charter Street Los Angeles Ca TABLE OF CONTENTS FLOW CHART...

DC Electronic Loads 8500 series

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

SD Rack. DiGiCo SD Rack. User Manual B - August

CB-100 LED Color Beam LED spotlight. user manual

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Hegel H80 High End Integrated Amplifier. User manual

CYMAQ Marking System AS200 + DS7050 N-14

SX460. Generator Automatic Voltage Regulator Operation Manual

1. BEFORE YOU BEGIN INTRODUCTION SETUP AC POWER... 7 Power Linking... 7 MOUNTING... 8 Orientation... 8 Rigging...

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

IT-12M IT-12D Ver_2.0 INTERPRETATION SYSTEM. User s Manual

1. Dispacking. 2. Safety Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Pocket DAB & FM Radio with Speaker

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

MANUAL ENGLISH. Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Tone Hammer 500. Owners Manual. Manual Version 1.0

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

TABLE OF CONTENTS. Page 2 of 13 MotionFaçade LED User Manual (Rev. 6)

USER MANUAL PLEASE KEEP THIS FOR FUTURE USE

DVB-T2 DIGITAL TV BOX

TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4

Getting started with

PDS-750-TR Touring Power Supply Operator s Manual

Nokeval. User's Manual Models 301 / 302 / 305

Ground Resistance Clamp On Tester

D4 HP Dimmer User s Manual Rev City Theatrical, Inc.

Quick start: Energy Switch EU

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Manual Ranging MultiMeter

AXIS T81B22 DC 30W Midspan

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

TC-9102 Series Surface Mount Temperature Controllers

Electric Landing Gear controllers and sequencer LGC12 / LGC 13C

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

ComPar KIT 1 & 2 DMX LED light set

MIGRATION HEIGHT-ADJUSTABLE DESKS. Troubleshooting Guide

±15 V Current-Limited Power Supply

Lab E1: Introduction to Circuits

Transcription:

General instructions Read the instructions in this handbook carefully, as they give important information regarding safety during installation, use and maintenance. Be sure to keep this instruction manual with the unit, in order to consult it in the future. If the unit is sold or given to another operator, make certain that it always has its manual, to enable the new owner to read about its operation and relative instructions This unit is not for home use, only professional applications Do not dismantle or modify the unit. Make certain that no inflammable liquids, water or metal objects enter the unit. Should any liquid be spilled on the unit, disconnected the power supply to the unit immediately. In the event of serious operating problems, stop using the unit immediately and either contact the nearest SGM sales point for a check or contact the manufacturer directly. Do not open the unit - there are no user serviceable parts inside Never try to repair the unit yourself. Repairs by unqualified people could cause damage or faulty operation. Contact your nearest authorized service centre. Always insist on original spare parts being fitted. Safeguard the environment: don't throw batteries, accumulators or packaging material into your waste bin - return them to your reseller or take them to the nearest special waste collection point. GB I D F E appendix 1

General warranty conditions The unit is guaranteed for 12 months from the date of purchase against material and manufacturing defects. Breakdown caused by carelessness and improper use of the unit is excluded. The guarantee is no longer valid if the unit has been tampered with or repaired by unauthorized personnel. The replacement of the unit is not foreseen by the guarantee. External parts, knobs, switches, removable parts and lamps are excluded from the guarantee: these are covered by their manufacturers' guarantee conditions. Transport costs and related risks are borne by the unit's owner. The guarantee is valid to all effects only on presentation of the guarantee certificate to the manufacturer or the nearest SGM technical assistance centre. Always quote the unit's serial number and model when contacting your reseller for information or assistance. How to contact SGM Elettronica Our customer assistance service can be contacted as follows: The offices are open from Monday to Friday, from 8.30am to 12.30pm and from 2.30pm to 6.30pm. (Italian local time: GMT + 1 - Daylight-saving time from March to October (+1 hour)) Fax (24/24 ore): +39-0721-476170 Tel: +39-0721-476477 http:// www.sgm.it E-Mail: info@sgm.it 2

Index 1 General Instructions 2 General guarantee conditions 2 How to contact SGM Elettronica 3 Index 4 changes to this manual 5 1 - Main features 5 1.1 - Technical specifications 6 1.2 - Installation 6 1.2.1 - Packaging 6 1.2.2 - Contents 6 1.2.3 - Before installation 7 1.3 - P612 connections 7 1.3.1 - Connecting to the mains supply 8 1.3.2 - Rear panels 9 1.3.3 - DMX signal cable 9 1.3.4 - DMX line connection example 10 1.3.5 - DMX termination construction 10 1.3.6 - RS-232 connection 11 1.3.7 - Switching on 11 1.3.8 - Using the microcomputer 12 1.3.9 - Signaling of the display 13 1.3.10 - menu 14 2 - Description of the menu 14 2.1 - Soft Patch 14 2.2 - Set chn mode 15 2.3 - Set chn level 15 2.4 - Set pre heat 16 2.5 - Channel test 17 2.6 - Brightness 17 2.7 - Signal Monitor 18 2.8 - Version 18 2.9 - Run Autotest 19 2.10 - Edit chase 20 2.11 - Run chase 20 2.12 - EQ curves 21 2.13 - Set Default 22 2.14 - Resume default 22 2.15 - Fixture name 23 3 - Protections 23 3.1 - Overheating protection 23 3.2 - Short-circuit protection 23 3.3 - Protection against incorrect connections 24 4 - Error messages GB I D F E appendix 3

Changes to this manual SGM has an on-going product development policy, so the information printed in this manual may not be completely up to date. If any doubts arise regarding the topics covered in this manual or should any further help be required, our online services (internet-server www.sgm.it ) are available 24 hours a day. In the FAQ section of the technical assistance zona, answers can be found to numerous common queries: fixtures, firmware and manuals can also be downloaded whenever required. Designed and Manufactured in Italy by SGM Elettronica srl Printed in January, 2002 Rel. 1.01 4

1. Main features Power supply: three phase 380V 3 PHASES + NEUTRAL, or single phase 110-220 V. Mains frequency 50/60 Hz. The power supply for the electronics' logic part is taken from the T phase + NEUTRAL. Maximum absorption: 144 Amps Input signal: DMX 512 or RS232 Cooling: forced ventilation by means of rear-mounted fans. Rotation speed is directly proportional to the temperature on the cooling fins. Protections: output protection with thermal/magnetic circuit breackers (k curve) Microcomputer: located on the front of the P1212D, this comprises a display with six buttons below it, enabling to carry out all settings necessary for correct installation, as well as testing all the functions. Operating modes: can be controlled using a lighting control console or used a stand-alone unit. In fact, it's possible to set the output level of the individual channels, or create 4 Chases with up to 32 steps (scenes) in each Chase. 1.1 Technical specifications power supply single phase 110/220 V 3-phase 3/N/PE 380V The logic power supply is taken from the load power supply Mains frequency 50/60 Hz Output current 12 A / channel rated output: 32Kw output voltage: 110/230 V. 50/60 Hz Type of load: resistive or inductive Interference filter 32 ma/µsec Inputs: DMX or RS232 Output connectors: SOCAPEX - CABUR - ILME (HARTING) - POWERCON NEUTRIK Frame dimensions - three 19" rack units (L x H x D): 442 x 113 x 400 mm Weight 18 kg. SGM Elettronica reserves the right to improve or modify their products at any time without prior notice. Always consult the handbook of the unit being used to avoid errors and differences between the actual functions and those shown in the manual. GB I D F E appendix 5

1.2 Installation 1.2.1 Packaging KEEP THE PACKAGING MATERIAL. Packaging material (plastic bags, polystyrene foam, nails, etc.) must not be left within children's reach, as it can be dangerous. Use the original packaging if the unit has to be returned to the manufacturer for repair or maintenance, as it has been specifically design to protect the unit during transport. 1.2.2 Contents After opening the box, check that the packaging contains the items in the following list, and make certain that the unit is in perfect condition. If in doubt, do not use the unit and contact an authorized SGM Technical Assistance Centre and the transport company. In fact, only the consignee can claim for any damage sustained by the unit during transport Power Light P1212D Guarantee Instruction manual 1 XLR 5 P male connector 1 XLR 5 P female connector 1.2.3 Before installation Read the following warnings before beginning installation. This unit is not intended for home use. Disconnect the power supply before carrying out any work on the unit. Electrical work necessary for installing the unit must be carried out by a qualified electrician or experienced person. Before connecting the unit, make certain that the data on the plate correspond to the mains power supply Avoid installing the units near sources of heat. Install the unit in a well-ventilated location. Avoid blocking the air intake and output vents. Never use the unit under the following conditions: - In places subject to excessive humidity - In places subject to vibrations or bumps. - In places with a temperature of over 45 C or less than 2 C Protect the unit from excessive dryness or humidity (ideal conditions are between 35% and 80%). Attention! The unit must be grounded. If this rule is not followed, the guarantee will automatically be considered null. page 8 P612D 6

1.3 Connection the P1212 1.3.1 Connecting the power supply It must be connected to a circuit with a thermal-magnetic cut-off switch.(see appendix page 1, 2, 3) Make certain that the cross-section of the socket's cables is sufficient for the power absorbed by the unit. Should it be necessary, replace the fuses with others of the same type and value. It's inadvisable to use adapters, in-line connectors or extension cables. Should their use be indispensable, make certain they're in compliance with current safety norms regarding component quality and cable length/cross-section. Attention! Class 1 unit. The ground conductor must be part of the power cord GB I D F E appendix 7

1.3.2 Rear panels cod 004-1052 SOCAPEX IN CH7-CH12 MAX 12A/CH 110/220V CH1-CH6 apparecchio non per uso domestico fixture not for domestic use MAIN 3/N/PE 380V 50/60HZ -32Kw Max A LINE NEUTRAL GROUND B CH7 1 2 13 CH1 CH8 3 4 14 CH2 CH9 5 6 15 CH3 CH10 7 8 16 CH4 CH11 9 10 17 CH5 CH12 11 12 18 CH6 OUT CHASSIS // // 19 // DMX 512 A CONSULTARE IL MANUALE PRIMA DI OGNI OPERAZIONE TO CONSULT THE MANUAL BEFORE EVERY OPERATION B Disconnect fixture before opening Non aprire prima di avere tolto la tensione cod 004-1053 POWERCON NEUTRIK IN CONSULTARE IL MANUALE PRIMA DI OGNI OPERAZIONE MAX 12A/CH 110/220V apparecchio non per uso domestico fixture not for domestic use MAIN 3/N/PE 380V 50/60HZ -32Kw Max CH11 CH9 CH7 CH5 CH3 CH1 OUT CH12 CH10 CH8 CH6 CH4 CH2 DMX 512 TO CONSULT THE MANUAL BEFORE EVERY OPERATION Disconnect fixture before opening Non aprire prima di avere tolto la tensione cod 004-1054 ILME IN CH1 CH3 CH5 CH7 CH9 CH11 CH2 CH4 CH6 CH8 CH10 CH12 apparecchio non per uso domestico fixture not for domestic use MAIN 3/N/PE 380V 50/60HZ -32Kw Max MAX 12A/CH 110/220V OUT DMX 512 CONSULTARE IL MANUALE PRIMA DI OGNI OPERAZIONE TO CONSULT THE MANUAL BEFORE EVERY OPERATION neutral out Disconnect fixture before opening Non aprire prima di avere tolto la tensione cod 004-1055 CABUR IN OUT DMX 512 CH12 CH11 CH10 CH9 TO CONSULT THE MANUAL BEFORE EVERY OPERATION MAX 12A/CH 110/220V CH8 CH7 CH6 CH5 CONSULTARE IL MANUALE PRIMA DI OGNI OPERAZIONE CH4 CH3 CH2 CH1 apparecchio non per uso domestico fixture not for domestic use MAIN 3/N/PE 380V 50/60HZ -32Kw Max Disconnect fixture before opening Non aprire prima di avere tolto la tensione 8

on/off grand master 100% 90 80 70 60 50 40 30 20 10 0 operations utility setup copy enter play extra lamp reset programming keyboard page store edit levels times memory 1-20 21-40 smpte rec universal dmx controller memory obj program chase psycho preset unit step multifunction keyboard 1 or 21 2 or 22 3 or 23 4 or 24 5 or 25 6 or 26 7 or 27 8 or 28 9 or 29 10 or 30 11 or 31 12 or 32 13 or 33 14 or 34 15 or 35 16 or 36 17 or 37 18 or 38 19 or 39 20 or 40 DIMMR 0 COLOR 0 GOBOS 0 SHUTT 0 ROTGB 0 FROST 0-0 - 0 pan tilt IN OUT see top cover for pin out IN OUT IN see top cover for pin out OUT CH12 CH12 CH11 CH11 CH10 CH10 CH9 TO CONSULT THE MANUAL BEFORE EVERY OPERATION CH12 CH11 CH10 CH9 TO CONSULT THE MANUAL BEFORE EVERY OPERATION CH9 TO CONSULT THE MANUAL BEFORE EVERY OPERATION MAX 12A/CH 110/220V CH8 CH7 CH6 CH5 CONSULTARE IL MANUALE PRIMA DI OGNI OPERAZIONE MAX 12A/CH 110/220V CH8 CH7 CH6 CH5 CONSULTARE IL MANUALE PRIMA DI OGNI OPERAZIONE MAX 12A/CH 110/220V CH8 CH7 CH6 CH5 CONSULTARE IL MANUALE PRIMA DI OGNI OPERAZIONE CH4 CH4 CH4 CH3 CH3 CH3 CH2 CH2 CH2 CH1 CH1 CH1 apparecchio non per uso domestico fixture not for domestic use MAIN 3/N/PE 380V 50/60HZ -32Kw Max Disconnect fixture before opening Non aprire prima di avere tolto la tensione apparecchio non per uso domestico fixture not for domestic use MAIN 3/N/PE 380V 50/60HZ -32Kw Max Disconnect fixture before opening Non aprire prima di avere tolto la tensione apparecchio non per uso domestico fixture not for domestic use MAIN 3/N/PE 380V 50/60HZ -32Kw Max Disconnect fixture before opening Non aprire prima di avere tolto la tensione 1.3.3 DMX signal cable construction Power Light P1212 has a DMX 512 input that uses standard XLR 5-pin connectors. When connecting, screened cable in compliance with EIA RS-485 specifications and with the following characteristics must be used: - 2 conductors plus screen - 120 Ohm impedance - low capacity - maximum transmission rate 250Kbaud. Connecting the cable: see diagram, taking care to ensure that the screen is connected to Pin 1 5 1 COMMON 4 3 2 DMX- DMX+ Attention: the cable screen (braid) must NEVER be connected to the system's ground, as this would cause faulty unit or controller operation. 1.3.4 Example of DMX line connection DMX line DMX 512 2000 Pilot2000 DMX 512 DMX controller input output DMX Termination (Last unit) To avoid the risk of faulty operation, follow the following indications: DMX 512 Maximum cable length: 500m Maximum N of units connected: 32 Cable run: Avoid running the cable alongside power lines. Termination: 120 ohm resistor across Pins 2 and 3 of the last unit. GB I D F E appendix 9

1.3.5 DMX termination construction The termination avoids the possibility of the DMX 512 signal being sent back along the cable once it reaches the end: under certain conditions and with certain lengths, this could cause it to over-ride the original signal and cancel it. The termination is made by soldering a 120 1/4 W resistor across pins 2 and 3 of the 5-pole male XLR connector (see diagram). 5 1 4 3 2 120Ω 1.3.6 Connection RS-232 Good quality screened RG 58 50 co-ax cables must be used for connections to avoid faulty equipment operation. Connectors used are always of the 5-pole XLR type. Refer to the diagram for wiring. RS-232 COMPUTER OUT 25 PIN CONNECTOR 6 20 RS-232 COMPUTER OUT 9 PIN CONNECTOR 3 4 6 5 7 8 10

1.3.7 Switching on As soon as it's switched on, the Power Light P1212 display the SGM logo with the software version, after which it begins an autotest (self test) routine to check for any irregularities in the power supply and on the output. Press ENTER to proceed to the Main Menu. 1.3.8 - Using the microcomputer 1 1 - The menus are scrolled using the UP/DOWN buttons 2 - Press ENTER to confirm the menu choice. 3 - The same set of square brackets can be moved between the various fields using the RIGHT/LEFT buttons and their contents changed using UP/DOWN. To return to the Main Menu, press ESC. GB I D F E appendix 11

1.3.9 Display view Initial message: SGM Electronics P1212 ver. 1.00 Normal operation: Fixture name DMX signal Warning messages (blinking writing): Fixture name signal error NO SIGNAL MISSING R PHASE MISSING S PHASE MISSING T PHASE Dangerous message (writing and display blinking at the same time): Fixture name over voltage OVERTEMP= C HIGH TEMP= C FANS FAILURE 12

1.3.10 menu ALL set all the channels [Soft Patch ] [Set Chn Mode ] CHN ADDR [1>>] 1 1>>:Set CHN1= ADDR; ch2 = ADDR+1;...;CHN12 = ADDR+11 CHN MODE [ALL] EXT ALL [Set Chn Level ] CHN LEVEL LEV% 1 [255] 100 ALL [Set Pre Heat ] CHN LEV% [ALL] 0.0 ALL [Channel Test ] CHN LEVEL LEV% 1 128 [ 80] ALL [Brightness ] < BRIGHT > [ [100%] ] [Signal Monitor] CHN LEVEL LEV% [ 1] 128 50 [Version ] SGM Electronics P1212 ver. 1.00 [Run Autotest ] [Edit Chase ] < AUTOTEST > RS232 Signal DMX SIGNAL NO SIGNAL SIGNAL ERROR OVERVOLTAGE FANS FAILURE NO OVERVOLTAGE FANS OK R PHASE OK S PHASE OK T PHASE OK T INT C F MISSING R PHASE MISSING S PHASE MISSING T PHASE OVER TEMP= C HIGH TEMP= C < EDIT CHASE > CHASE [4] LN ST CHN LEV [1] 1 ALL 255 ALL [Run Chase ] [Curve Equaliz ] [Set Default ] [Resume Default] CHS CR SP LEV [1] 99 99 255 CHN CURVE N 3 [4] < SET DEFAULT > NO [YES] <RESUME DEFAULT> NO [YES] ALL [Fixture Name ] <FIXTURE NAME > P1212 GB I D F E appendix 13

2 - Menu descriptions 2.1 Soft Patch In this Menu, it's possible to assign the POWER LIGHT's physical channels (CHN) to the digital channels available (ADDR). This creates a correspondence between the Dimmer output channel and the channel that has to be controlled. There are 512 channels available for use, i.e., those provided for by DMX standard, and they don't necessarily have to be in succession. For access to the Soft Patch function, proceed as follows: 1. Select SOFTPATCH in the main menu; [Soft Patch ] 2. Press Enter to confirm the choice; 3. Move the square brackets to the CHN field and select the channel to be assigned; selecting 1>> CHN1=ADDR; CHN2=ADDR+1;...;ADDR11=ADDR+11. CHN ADDR [1] 1 4. Move the square brackets to the ADDR field to assign the digital channel to the channel tha has just been selected; 5. Repeat from point 3 to assign the other channels. 6. Press Esc to return to the main menu - the selected data are automatically updated. 2.2 Set Chn Mode (Channel Mode) In this Menu, it's possible to choose the operating mode for each individual channel. It is in fact possible to control the Power Light's channels independently or via a lighting control desk. There are three operating modes available: - FIX. The output of channels set in this mode isn't controlled by a lighting control desk and remains fixed on a value which can be set later. - OFF. The output of channels set in this operating mode stays off and cannot be controlled by a lighting control desk - EXT. (EXTERNAL) Output channels set in this mode can only be controlled by a lighting control desk. The standard factory setting is with all the channels in EXT. For access to the Set Channel Mode function, proceed as follows: 1. Select the Channel Mode menu from the main menu; [Set chn mode ] 14

2. Press Enter to confirm the choice; 3. Move the square brackets to the CHN field and select the channel to which the operating mode has to be assigned;(all set all the channels) 4. Now move the square brackets to the MOD field to assign one of the three operating modes available; CHN MOD 2 [FIX] 5. Repeat from point 3 to set the other channels. 6. Press Esc to return to the main menu: 2.3 Set Chn Level (Channel Level) In this Menu it's possible to set the level of each individual channel configured in FIX mode in the previous menu. To access the Set Channel Level function, proceed as follows: 1. Select the Set Channel Level menu from the main menu; [Set chn level ] 2. Press Enter to confirm the choice; 3. Move the square brackets to the CHN field and select the channel the output level has to be set on;(all set all the channels) 4. Now move the square brackets to the LEV field to assign the output level. This is expressed as a decimal value of between 000 and 255; CHN LEV 2 [255] 5. Repeat from point 3 to set the other channels. 6. Press Esc to return to the main menu: the selected data are automatically updated. 2.4 Set Pre Heat In this Menu, it's possible to set the pre heat (warm-up) level of each individual channel. Incandescent lamps' behaviour varies according to the power voltage they are supplied. When they are cold, before voltage is applied, the filament has a very low resistance, so at the moment in which the voltage is applied, a very high current will pass through the lamp. This explains why frequent voltage changes can have a negative effect on lamp life: it's therefore indispensable to set warm-up level. This enables to set the minimum current which must pass through in the lamp when it is not lit, in order for the absorption of current to be reduced and lamp life increased. This is expressed as a percentage of between 0% and 9.9% and is usually left at zero for inductive loads (neon, par 36), whereas for resistive loads it varies according to the type of lamp used. GB I D F E appendix 15

For a good warm-up, it's sufficient to increase the level until the filament becomes just visible. Standard factory warm-up setting is 4% For access to the Set Pre Heat function, proceed as follows: 1. Select the Set Pre Heat menu from the main menu; [Set pre heat ] 2. Press Enter to confirm the choice; 3. Move the square brackets to the CHN field and select the channel whose pre-heat level has to be set; (ALLset all the channels) 4. Now move the square brackets to the LEV% field to assign the pre-heat level. This is expressed as a percentage with a value of between 0 and 9.9%; CHN LEV% 6 [4.0%] 5. Repeat from point 3 to set the other channels. 6. Press Esc to return to the main menu: the selected data are automatically updated. 2.5 Channel Test In this Menu, it's possible to check if a channel has any problems. In fact, by selecting the channel on which there are doubts, Power Light controls its efficiency, allowing to vary its value from 0 to maximum output and switching off the channels not involved and ignoring any previous assignments or the presence of an input signal. Only one channel can be checked at a time. For access to the Channel Test function, proceed as follows: 1. Select the Channel Test menu from the main menu [Channel test ] 2. Press Enter to confirm the choice 3. Move the square brackets to the CHN field and select the channel to be checked the ALL option executes the test on all the channels at the some time 4. Now move the square brackets to the LEV field to assign the output level holding down the button, will bring the channel output to 255(full) in the event of LEV field=0. CHN LEV 1 [0] 5. Repeat from point 3 to set the other channels 6. Press Esc to return to the main menu: the selected data are updated automatically. 16

2.6 Brightness In this Menu, it's possible to vary the brightness of the LCD display on the front panel. This brightness is expressed as a percentage and varies between 0 and 100%. The standard factory setting of the LCD brightness is 75% For access to the Brightness function, proceed as follows: 1. Select the Brightness menu from the main menu; [Brightness ] 2. Press Enter to confirm the choice; 3. The square brackets are positioned on the only field. Use the UP/DOWN arrows to reach the brightness required. < BRIGHT > [ [75%] ] 4. Press Esc to return to the main menu: the selected data are updated automatically. 2.7 Signal Monitor In this Menu, it's possible to check the level of the signal for controlling the channels on input. Only one channel can be checked at a time. For access to the Signal Monitor function, proceed as follows: 1. Select the Signal Monitor menu from the main menu; [Signal monitor] 2. Press ENTER to confirm the choice; 3. The square brackets will be positioned on the CHN field to allow the channel to be selected. CHN LEV [1] 0 4. Once the channel has been selected, the signal level will automatically appear in the LEV field. This field cannot be modified as it only displays the signal level on input. 5. Press ESC to return to the main menu. GB I D F E appendix 17

2.8 Version This Menu gives information on the software version installed in the Power Light. Version is a menu only used for consultation, in which no parameters can be changed. For access to this function, proceed as follows: 1. Select the Version menu from the main menu; [Version ] 2. Press ENTER to confirm the choice; 3. At this point, the current version of the software will appear on the display. SGM Electronics P1212 ver. 1.00 4. Press ESC to return to the main menu. 2.9 Run Autotest This Menu runs an autotest routine which enables irregularities to be found in some crucial points of the Power Light. In fact. the following parameters are checked: - the presence (or not) of DMX signal on input; - any excess voltage on input, - correct operation of both fans; - the presence (or not) of RS-232 signal on input; - the temperature on the cooling fins expressed in degrees Centigrade and Fahrenheit. Run Autotest is only an executive menu - no parameters can be modified. For access to this function, proceed as follows : 1. Select the Autotest Run menu from the main menu; [Version ] 2. Press Enter to confirm the choice; 3. A this point, the results of the measurements made for all the abovementioned parameters will appear one after another on the display. AUTOTESTING [OVERLOAD NO] 4. Press Esc to return to the main menu. 18

2.10 Edit Chase The P1212 has been designed and built so that it can also be used as a free-standing unit, without the aid of an external controller. It's possible to create 8 different sequences (Chases) with a maximum of 32 scenes (Steps) each. For access to the programming function of the Edit Chase menu, proceed as follows: 1. Select the EDIT CHASE menu from the main menu; [Edit chase ] 2. Press ENTER to confirm the choice; 3. Now select the number of the Chase to be programmed, which can be between 1 and 8 <Edit chase > Chase [1] 4. Press ENTER to confirm the choice; 5. At this point, the following appears on the display: LN ST CHN LEV [10] 1 1 255 LN: Maximum number of steps ST: Current step CHN: Channel (ALLset all the channels) LEV: light output level assigned to the channel (0-255) 6. Firstly, set the maximum number of steps that the chase in the LN field must have 7. Move the square brackets to the ST field and select the first step to program. 8. Move the square brackets to the CHN field and select the channel whose output level has to be adjusted. 9. Move the square brackets to the LEV field and change the output level to the required value. 10. Repeat points 7-8-9 for all the steps. 11. Press ESC to confirm the changes and return to the previous menu. GB I D F E appendix 19

2.11 Run Chase In this menu, it's possible to run the Chase previously programmed with the possibility of adjusting the chase's times and master level. To access the programming function of the Run Chase menu, proceed as follows: 1. Select the RUN CHASE menu from the main menu; [Run chase ] 2. Press ENTER to confirm the choice; 3. At this point, the following appears on the display: CHS CR SP LEV [1] 55 55 255 CHS: Chase CR: CROSS Time expressed in secondsi SP: SPEED expressed in seconds LEV: general light output level assigned to the CHASE (0-255) 4.For the chase selected in the CHS field, set the CROSS and SPEED times required and the general light level. 5.Press ESC to confirm changes and return to the main menu. 2.12 Curve Equaliz (Curve Equalization) In this menu, it's possible to assign each channel the most suitable setting for controlling the load on output according to the type of lamp used. The 6 curves available are shown in the diagram. 1- linear curve 2- logarithmic curve 1 3- logarithmic curve 2 4- logarithmic curve 3 5- logarithmic curve 4 6- logarithmic curve 5 7- on / off curve 20

For access to the Curve Equal function, proceed as follows: 1. Select the Curve Equal menu from the main menu; [Curve Equaliz] 2. Press ENTER to confirm the choice; 3. Move the square brackets to the CHN field and select the channel whose equalization curve has to be changed (ALL: assigns the same value to all the channels) CHN CURVE N [1] 1 4. Move the square brackets to the CURVE N field and select the equalization curve to be assigned to the chosen channel. 5. Press the ESC button to return to the main menu: the selected data are automatically updated 2.13 Set default This feature allow to customized the default parameters;for the following menu Soft Patch, Set Chn Mode, Set Chn Level, Set Pre Heat, Curve Equaliz For access to the programming function of the Set Default proceed as follows: 1. Select the Set default menu from the main menu; [Set Default] 2. Press ENTER to confirm the choice; 3. Move the square brackets to the YES field <SET DEFAULT > NO [YES] 4. Press ENTER to confirm the choice; 5. Press ESC to confirm the changes and return to the previous menu. GB I D F E appendix 21

2.14 Resume default This feature allow to resume the default parameters: To access the programming function of the Resume default menu, proceed as follows: 1. Select the Set default menu from the main menu; [Resume Default] 2. Press ENTER to confirm the choice; 3. Move the square brackets to the YES field <RESUME DEFAULT> 4. Press ENTER to confirm the choice; 5. Press ESC to confirm the changes and return to the previous menu. 2.15 Fixture name This feature allow to set the default parameter: To access the programming function of the Fixture name menu, proceed as follows: 1. Select the Fixture name menu from the main menu; [Fixture Name] 2. Press ENTER to confirm the choice; 3. Select the letter by using up/down, the button will move to the next letter <FIXTURE NAME > [A] NO [YES] 4. Press ENTER to confirm the choice; 5. Press ESC to confirm the changes and return to the previous menu. 22

3 - Protections Particular protections are provided to avoid any faulty operation seriously damaging the Power Light. These protections are: 3.1 - OVER-HEATING PROTECTION: the maximum temperature allowed is 90ºC and is measured on the cooling fin on the power section. If this temperature is exceeded, the output is disabled until temperature returns within the foreseen limits. At 80, an over-heating pre-alarm message is given. 3.2 - PROTECTION AGAINST SHORT-CIRCUITING: Thermal circuit breackers will cut off the channel. 3.3 - PROTECTION AGAINST INCORRECT CONNECTIONS: The display will show the missing phase. 4 - Error messages Error messages are indicated by the display giving a long flash. Should a message indicating an irregularity appear, switch off the Power Light immediately, find the cause and eliminate it. If there are several messages simultaneously, they appear one after another. Message displayed NO SIGNAL SIGNAL ERROR OVERVOLTAGE FANS FAILURE MISSING R PHASE MISSING S PHASE MISSING T PHASE CAUSE No DMX (RS232) signal on in input Incorect DMX (RS232) signal High voltage on R, S or T phase Fans failure Missing phase OVERTEMP= C At 90 C the outputs is disabled HIGH TEMP= C At 80 C Pre-allarm message is given GB I D F E appendix 23