The 50 Series ph Meter

Similar documents
Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Compact Water Quality Meter B-700 series

SenTix 950 SenTix 980

DPST-ELMETRON-meters. Contents: ELMETRON 100 series pocket instruments. ELMETRON 411 series portable meters. ELMETRON 401 series portable meters

Compact ph Measuring Instruments

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Ion-selective Measurements

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Measurement by Ion Selective Electrodes

Milwaukee USER MANUAL

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Portable digital microprocessor thermometers with interchangeable probes

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Wireless Data Logger. Collect, Manage and Monitor Your Valuable Data via Wireless Communication. Register and Manage Remote Units by Groups

Sales and Support in the US and CA by: NuAire, Inc Fernbrook Lane Plymouth, MN

Density/Specific Gravity/ Concentration Meter DMA 500

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Portable Hardness Tester

ph Measurement and Control

HND-R. Hand-held ph, Redox and Temperature Measuring Units

DISSOLVED OXYGEN METER Model : DO-5509

Hand-held thermometer Model CTH7000

ExStik TM ph Waterproof Meters

ELECTROCHEMISTRY. Theory and Practice

DC Electronic Loads 8500 series

FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL

Vacuum drying oven for non-flammable solvents

Multi-Range Programmable DC Power Supplies 9115 Series

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

ph 200 ph-/redox-/temperature Meter Operating instructions

Poor quality welds Machine downtime High maintenance costs Lost revenue

USEPA Electrode Method Method 8156

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

Duct Humidity Transmitter

VICKERS HARDNESS TESTER. HBS HBW Kc

TurbiDirect TurbiCheck TurbiCheck WL

Operation Manual For NDJ-8S Digital Rotary Viscometer

Light Meter (Foot Candles)

Temperature & Humidity SMS Alert Controller

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

AIRMoN, ph and Conductivity Field Measurement

PART 1 - INTRODUCTION...

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Root ZX II Endodontic Predictability Apex Locator with Low Speed Handpiece. Thinking ahead. Focused on life.

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

DISSOLVED OXYGEN PROBE

Care and use guide. Contents. a handy solution made easy. page

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

Refer to page 6 to page 19 for detailed instructions.

Hand-held marking system FlyMarker mini

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

UltraBasic Benchtop ph Meter Operation Manual

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

The power of innovation. For better media preparation. Media preparators Systec MediaPrep.

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

Operating Principle of the Sample Positioning Flaps

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

Optical Power Meter. Specification & User Manual

BW-500 BED WEIGHER USER MANUAL

REDOX AND REFERENCE ELECTRODE USER MANUAL

Quick Connect. quick - simple - efficient.

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

Basic Specifications. Electrical. EPSON Perfection Color EPSON MatrixCCD TM line sensor. device Effective pixels

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Operating Instructions

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

How To Read A Pipe From A Sensor

A Potentiometric Analysis of Fluoride Ion in Toothpaste

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

BOD measurement. BOD measurements. Respiration. Biological Oxygen Demand. Depletion/Respiration

Contents & P-LCD Modules Cross Reference Table

Incubator with mechanical convection

Color, True and Apparent

LED Anti-Collision Lighting System for Airbus A320 Family

Heating oven with mechanical convection

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

User's Guide. Integrating Sound Level Datalogger. Model Introduction

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes

Measuring Soil Moisture for Irrigation Water Management

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

Color, True and Apparent

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

STD - STANDARD VERSION extended possibilities reasonable price wide range of optional equipment

Model 4510 Conductivity/TDS Meter Operating Manual

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

Titrette. class A precision. The next generation Digital Burette!

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

Phosphorus, Reactive (Orthophosphate)

Transcription:

The 50 Series ph Meter Takeshi Kobayashi [The Development Team (Main body)] Upper left: Yuichi Ito Back row from the left: Seiichiro Yoshioka, Takeshi Shimizu, Hiroyuki Kitamura, Takeshi Mori, Yosuke Hisamori Front row from the left: Yoshiyuki Okada, Mitsuru Honjo, Yoshihiro Tarui, Katsuaki Ogura, Yoshihiko Ida [The Development Team (Electrode)] Back row from the left: Yuji Nishio, Yasukazu Iwamoto, Nobuki Yoshioka, Shinji Takeichi, Takeshi Kobayashi, Kenichi Tanaka Front row from the left: Hiromi Ohkawa, Tsuyoshi Nakanishi, Satoshi Nomura, Hiroki Tanabe, Koji Ueda In developing the 50 Series, we focused on the following two points: ease of use of the basic ph meter main unit and enhancement of the electrode performance as the most vital features for ph measurement. By adding a navigation function with character display, which is not used by conventional analyzers, as well as adopting the world s first color display, our new bench top ph meter has proved user friendly even for customers with no ph measurement knowledge. We took the World s top performing ToupH glass electrode series and succeeded in increasing the electrode life by improving the performance of the reference electrode and strengthening the durability of glass material. Also, the ph measurement field has been extended to new and unconventional measurement areas by commercialization of the glassfree ISFET electrode. This article describes features of this product in detail. 88 English Edition No.9

Technical Reports Introduction This product is commercially manufactured as the 50 series and is a model change from the conventional D-20 series and F-20 series and commemorates HORIBA s 50th anniversary. In this development, a number of product lineups such as the ph meter main body, electrodes, and cleaning solution have been produced simultaneously. We have focused on developing user-friendly products common to all. We first decided the product concept by visiting a large number of customers before commencing development. Approximately a year and a half has now passed since the products were released, and we have received many favorable comments from our customers. The following are feature descriptions of each new product. ph Meter Main Unit This development has seen a total of 14 models of the D-50 series for on-site measurement and also the F-50 series for laboratory use, simultaneously produced in approximately one year, an unusually short period. Portable ph Meter The portable D-50 series ph meter has been produced for easier on-site use and is based on the conventional D-20 series. Figure 1 is a photo of the D-50 series, and Table 1 shows the main specifications. Table 1 Main Specifications of the D-50 Series Figure 1 The D-50 Series Measurement method D-51 D-52 D-53 D-54 D-55 Glass electrode method ph Measurement range ph 0.00 to 14.00 mv (ORP) Temperature Repeatability ±0.01 ph ±1 digit Measurement range - -1999 to1999 mv Repeatability - ±1 mv ±1 digit Measurement range 0.0 to 100.0 C Repeatability ±0.1 C ±1 digit Measurement method - - Ion selective electrode method - - Ion Measurement range - - 0.00 µg/l to 999 g/l (mol/l) - - Conductivity Repeatability - - ±0.5%F.S.±1 digit - - Measurement method - - - AC bipolar method - Cell constant 100 m -1 : 0.000 ms/m to 19.99 S/m Measurement range - - - Cell constant 10 m -1 : - 0.0 µs/m to 1.999 S/m Cell constant 1000 m -1 : 0.00 ms/m to 199.9 S/m Repeatability - - - ±0.5% F.S.±1 digit - Measurement method - - - - Dissolved oxygen Measurement range - - - - Diaphragm galvanic battery method 0.00 mg/l to 19.99 mg/l Repeatability - - - - ±0.1 mg/l±1 digit Ambient temperature 0 to 45 C Input CH 1 2 Power supply DC 3 V (LR6 dry cell battery) Option: AC adapter 100 to 240 V 50/60 Hz Power consumption Approx. 0.03 W Approx. 0.06 W Approx. 0.03 W Battery life Approx. 200 hours Approx. 100 hours Approx. 200 hours Mass of main unit (including dry cell batteries) Approx. 300 g Approx. 330 g 89

The 50 Series ph Meter The D-50 series has a compact waterproof body with numerous features. The main features are as follows: 1. Handiness As conventional meters are too large for some people to carry in one hand, our main emphasis was on handiness such that the unit should be easily carried in one hand and so we reduced the size to 2/3 that of conventional units. To realize this size, we used a membrane switch for the switch section and separated the electrode holder from the main unit so that the electrode can be carried in a case. 2. Legibility To make the measured value more legible, we used a display that is approximately 1.5 times larger than that of D-20 series. To show when electrode replacement is required, an electrode life indication was added in accordance with the sensitivity at the time of calibration. 3. Easy data handling (D-52, 53, 54, 55) Conventionally an adapter has been required for connection to a PC, but the RS-232C port connection has enabled direct PC connection. Also, the main unit is capable of storing 300 data records and automatic data storage with a minimum interval of 2 seconds. These data can then be exported to a PC where a report can be created. Benchtop ph Meter During commercial production of the Benchtop F-50 series ph meter (F-52, 53, 54, 55), our investigations revealed that the most inconvenient points that customers are facing occur when actually using the ph meter. The majority of customers that anticipated problems were uneasy about possible electrode and sample measurement difficulties despite there actually being no significant problems. We therefore focused on how the unit should respond in case of difficulties. Aiming for a positive response when a problem occurs, we provided a human character for the ph meter, adding a sense of humor. The Doctor instructs with his know-how of ph measurement at turning on the character switch. Figure 2 shows a photo of the F-55 series, and Table 2 shows the main specifications of F-50 series. Table 2 Main Specifications of F-50 Series Figure 2 The Model F-55 Measurement method F-51 F-52 F-53 F-54 F-55 Glass electrode method ph Measurement range ph 0.00 to 14.00 ph 0.000 to 14.000 mv (ORP) Temperature Repeatability ±0.01 ph ±1 digit ±0.001 ph ±1 digit Measurement range -1999 to1999-1999.9 to1999.9 Repeatability ±1 mv ±1 digit ±0.1 mv ±1 digit Measurement range 0.0 to 100.0 C Repeatability ±0.1 C ±1 digit Measurement method - - Ion selective electrode method - Ion selective electrode method Ion Measurement range - - 0.00 µg/l to 999 g/l (mol/l) - 0.00 µg/l to 999 g/l (mol/l) Repeatability - - ±0.5%F.S.±1 digit - ±0.5%F.S.±1 digit Measurement method - - - AC bipolar method Cell constant 100 m -1 : 0.000 ms/m to 19.99 S/m Conductivity Measurement range Cell constant 1000 m -1 : 0.00 ms/m to 199.9 S/m - - - Cell constant 10 m -1 : 0.0 µs/m to 1.999 S/m Repeatability - - - ±0.5% F.S.±1 digit Input CH 1 2 Ambient temperature 0 to 45 C Power supply DC 6 V (LR6 dry cell battery) Option: AC adapter AC adapter 100 to 240 V 50/60 Hz Power consumption Approx. 0.024 W Approx. 8.4 W Battery life Approx. 500 hours - Mass of main unit (including dry cell batteries) Approx. 1 kg Approx. 1.1 kg 90 English Edition No.9

Technical Reports The main product features of F-50 series are as follows: 1. Color screen For the first time a color screen has been adopted for a ph meter. In addition to the conventional digital display and graphic display, an analog-style indicator has been used for displaying the measured value (Figure 3). Figure 3 Analog-style Indicator Going back more than ten years, ph meters were all equipped with analog indicators, and so many customers have strongly requested their return. Requiring no setup as the range is set automatically, this analog-style screen is suitable for checking for a stable indication condition, a feature requested by a number of customers. The customer can select from seven display screen colors. Figure 4 Display when Calibration has Succeeded 2. Navigation function A character display shows the calibrated state after calibration, along with guidance for the standard solution measurement while calibrating. When the calibration is successful, OK is displayed (Figure 4), and the value of the calibrated standard solution, electric potential, and temperature are precisely displayed, so revealing the asymmetric potential and sensitivity. If the calibration fails, the cause of the failure is displayed and countermeasures are displayed by pressing the Navi key (Figure 5). This facilitates the operation if a problem occurs. Figure 5 Display when Calibration has Failed 91

The 50 Series ph Meter 3. PC interface All the models of F-50 series are equipped with a PC communication function through RS-232C. The high-end models are equipped with the world s first compact flash memory for a ph meter. With 16 MB memory preinstalled. Approximately 3000 measurements can be stored. Even though it may be impractical to carry the PC to the measurement site because the ph meter is normally used around water, easy data transfer is possible. Additionally the high-end models are equipped with a LAN networking connection, allowing communication of usage information to a PC. PC Software The PC software for both the D-50 series and the F-50 series is available to download free after customer registration on HORIBA s web site. This software allows easy retrieval of data stored in the ph meter and facilitates creating reports from this data. The PC software for Part 11, the first software for ph meters conforming to the Part 11 regulation, was also produced as the PC software for F-55. The official name for Part 11 is FDA CFR 21 Part 11 issued by the U.S. Food and Drug Administration (FDA), which is a regulation for confirming reliable data and avoiding falsification of electronic records. It means the unit is equipped with a function for preventing electronic data from being falsified in order to correspond to this regulation. These functions enable introduction of the ph meter and its system to among others, the pharmaceutical industry with its stringent quality standards. ph Checker Recently a validation strategy for ph measurement has been in great demand. The meter s operation check is the key to this requirement. Previously, small and highly precise checkers did not exist. The ph checker X-51, provided with simulation outputs such as ph, temperature, ion, and dissolved oxygen, is produced with the 50 series. Furthermore, there is the X-52, with the conductivity simulation output only. Even personnel unfamiliar with the service technology can easily check the performance of a ph meter by using this checker with the F-50 series. The response can be definitely verified to Installation Qualification (IQ), Operational Qualification (OQ), Performance Qualification (PQ) required by the pharmaceutical industry and the wide range of industries that have started using this device. Figure 6 shows the screen of F-50 series while checking using the ph checker. After check Figure 6 Screens during Checking 92 English Edition No.9

Technical Reports Glass Electrode We developed the electrode using our long-term experience selling ph meters and to respond to customer requests as much as possible. After investigation, we found that costumers were not satisfied with the problem that different measured values are obtained when using two or more ph meters, which causes difficulties judging which value is true. Then we investigated the causes from various aspects, and found that particularly most problems were caused on the reference electrode side of the ph electrode. This is due to use of the silver-silver chloride inner electrode of the reference electrode, which results in silver outflow, clogging the liquid junction where the sample and inner solution contact. Therefore we built-in silver ion traps in all newly developed electrodes (Figure 7) to prevent the silver outflow from causing indication errors. Figure 8 ph Waterproof Thick Membrane Glass Electrode ToupH The sleeve type ToupH (9677-10D) electrode (Figure 9) has been produced for proteins and samples with high viscosity. It is suitable for this because the reference electrode liquid junction of the sleeve type reference electrode is washable. Silver ion trap Silver-silver choloride electrode Teflon coating + Pinhole treatment Ion trap agent Figure 9 Sleeve Type ToupH Electrode for Samples with High Viscosity Liquid junction Figure 7 Ion Trap Ceramics The tip of the conventional glass electrode is made of thin glass membrane, therefore, the electrode had to be exchanged when the response section was broken. In the new product, the tip of the glass body electrode is made of thick membrane, and the structure has been changed so that the response section is located at the side. From this structural change, the glass electrode has been strengthened and improved. It has been released under the name of ToupH (Figure 8). In addition, the micro ToupH (9669-10D) electrode (Figure 10) has also been produced as an electrode to measure small quantities of samples. The glass response membrane, reference electrode, and temperature electrode are mounted within an area of only 3 mm diameter to enable measurement of only 0.3 ml samples. Figure 10 Micro ToupH Electrode for Small Amount Samples 93

The 50 Series ph Meter A conventional micro electrode would hardly be able to measure correctly small amount samples due to influence of contamination or clogging of the silver-silver chloride inner electrode. The newly produced micro electrode adopts the ToupH glass, to maintain the same performance as that of the standard size one. The performance of the reference electrode is also drastically improved by mounting the silver ion trap. Some measured values from the conventional small amount electrode were abnormal due to bubbles generated inside the glass electrode. However the shape was modified to counter this so that the string (contact liquid line) is inserted to the tip of the inside of the glass electrode to maintain conductivity even if bubbles are generated. The result is popular among customers who wish to reduce the sample amount of valuable samples, and customers who are unable to measure due to small amount samples. So, we wish to continue with product development that utilizes HORIBA s electrode technologies. Table 3 shows the main specifications of electrodes. Table 3 Main Specifications of Electrodes Waterproof thick membrane Plastic body type electrode ToupH electrode for samples Micro electrode glass type ToupH electrode with high viscosity for small amount samples 9611-10D 9621-10D 9677-10D 9669-10D Measurement 0 to 80 0 to 100 0 to 60 0 to 60 temperature range ( C) (Immersion measurement:0 to 50) Storage temperature 0 to 50 0 to 50 0 to 50 0 to 50 range ( C) ph range 0 to 14 0 to 14 0 to 14 0 to 14 ph response glass ToupH glass Glass for low conductivity ToupH glass ToupH glass Response membrane form 8 mm Tube type 6.4 mm Globular 8 mm Tube type 3 mm Tube type Structure of Sliding type Sliding type Sliding type Sliding type refilling section of reference electrode inner solution Liquid junction Ceramics Ceramics Movable sleeve Ceramics Liquid junction material Glass/ceramics Glass/Silicone rubber/ceramics/ Glass Glass/ceramics Polysulfone/Polyacetal/ Polyimide/Polyamide/PVC Liquid junction 12 mm 16 mm 12 mm 3 mm diameter Electrode length 150 mm 150 mm 150 mm 155 mm (including a cap) Liquid junction height 18 mm 15 mm 26 mm 10 mm Inner electrode Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl Silver ion trap Inner solution of 3.33 mol/l KCl 3.33 mol/l KCl 3.33 mol/l KCl 3.33 mol/l KCl reference electrode Max. immersion depth - 1 m - - ISFET Electrode The ISFET electrode (0030-10D) (Figure 11), HORIBA s new product can be connected to conventional ph meters by inserting the required converter into the electrode grip. The tip of this electrode is pointed, which enables measurement by insertion into samples. Conventional glass is not used as the electrode material, therefore, it can be used at food processing sites where the presence of glass is prohibited. Examples: 1) ISFET can perform on-the-spot measurement at food manufacturing sites. Conventional food ph measurement requires that the food is taken to a laboratory where it is crushed and extracted using water. 2) ISFET can measure by directly thrusting into ground soil, which enables soil measurement at multiple locations, requiring no water, whereas conventional methods use extracted samples of soil for ph measurement. Figure 11 ISFET Electrode 94 English Edition No.9

Technical Reports Electrode Cleaning Solution The electrode cleaning solution (#220) is a useful spin-off of the 50 series development. Hydrochloric acid is an effective conventional cleaning solution for the glass electrode when the ph electrode has deteriorated, because it removes dust from the glass surface, and thiourea solution is effective for the reference electrode because it removes the silver clogged silver on the inner electrode. However, it is difficult for most customers to condition solutions such as hydrochloric acid or thiourea solution. On the other hand, a number of evaluations were required for the life test of the cleaning solution as it must be verified first before coming into general use. For this product, we fixed a time of six months life from first manufacture to successful production. Although it is not a major product, we sincerely recommend this solution for cleaning the electrode in cases where calibration is not possible during use. Conclusion We have simultaneously developed a number of items including 16 types of main unit (including checkers), 4 types of electrode, and a cleaning solution. Despite a tightly scheduled development over a short period of approximately a year, we still received favorable feedback from our customers and so we felt somewhat satisfied with our work. We wish now to maintain this momentum of product development by continuing to listen to and consider our customers comments. 95