MAX9621 Dual, 2-Wire Hall-Effect Sensor Interface with Analog and Digital Outputs

Similar documents
MAX14760/MAX14762/MAX14764 Above- and Below-the-Rails Low-Leakage Analog Switches

Cold-Junction-Compensated K-Thermocoupleto-Digital Converter (0 C to C)

ABRIDGED DATA SHEET EVALUATION KIT AVAILABLE

V CC TOP VIEW. f SSO = 20MHz to 134MHz (DITHERED)

High-Speed, Low-Power, 3V/5V, Rail-to-Rail, Single-Supply Comparators MAX941/MAX942/ MAX944. General Description. Features. Ordering Information

On/Off Controller with Debounce and

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

ICS SPREAD SPECTRUM CLOCK SYNTHESIZER. Description. Features. Block Diagram DATASHEET

24-Channel Automotive Switch Monitor

200mA, Automotive, Ultra-Low Quiescent Current, Linear Regulator

AAT3520/2/4 MicroPower Microprocessor Reset Circuit

Spread-Spectrum Crystal Multiplier DS1080L. Features

R EXT THERMISTOR. Maxim Integrated Products 1

STLQ ma, ultra low quiescent current linear voltage regulator. Description. Features. Application

TRIPLE PLL FIELD PROG. SPREAD SPECTRUM CLOCK SYNTHESIZER. Features

Features. V PP IN V CC3 IN V CC5 IN (opt) EN0 EN1 MIC2562

Features. Modulation Frequency (khz) VDD. PLL Clock Synthesizer with Spread Spectrum Circuitry GND

Push-Pull FET Driver with Integrated Oscillator and Clock Output

Quad, Rail-to-Rail, Fault-Protected, SPST Analog Switches

DS1220Y 16k Nonvolatile SRAM

AP331A XX G - 7. Lead Free G : Green. Packaging (Note 2)

MAX14759/MAX14761/MAX14763 Above- and Below-the-Rails Low On-Resistance Analog Switches

Hardware Documentation. Data Sheet HAL 202. Hall-Effect Sensor. Edition Sept. 18, 2014 DSH000159_002EN

MM74HC4538 Dual Retriggerable Monostable Multivibrator

High-Speed, 5 V, 0.1 F CMOS RS-232 Driver/Receivers ADM202/ADM203

High Voltage Current Shunt Monitor AD8212

ICS514 LOCO PLL CLOCK GENERATOR. Description. Features. Block Diagram DATASHEET

TS555. Low-power single CMOS timer. Description. Features. The TS555 is a single CMOS timer with very low consumption:

Advanced Monolithic Systems

Discontinued Product For Reference Only

AAT4280 Slew Rate Controlled Load Switch

TLI4946. Datasheet TLI4946K, TLI4946-2K, TLI4946-2L. Sense and Control. May 2009

Microprocessor Supervisory Circuits

DM74121 One-Shot with Clear and Complementary Outputs

ICS379. Quad PLL with VCXO Quick Turn Clock. Description. Features. Block Diagram

SPREAD SPECTRUM CLOCK GENERATOR. Features

1 TO 4 CLOCK BUFFER ICS551. Description. Features. Block Diagram DATASHEET

SG2525A SG3525A REGULATING PULSE WIDTH MODULATORS

Low-Cost, Micropower, SC70/SOT23-8, Microphone Preamplifiers with Complete Shutdown

STWD100. Watchdog timer circuit. Description. Features. Applications

CAT4101TV. 1 A Constant-Current LED Driver with PWM Dimming

480mA White LED 1x/1.5x/2x Charge Pump for Backlighting and Camera Flash

MAX1501 Highly Integrated, Linear Battery Charger with Thermal Regulation for Portable Applications

MIC2940A/2941A. Features. General Description. Applications. Pin Configuration. 1.2A Low-Dropout Voltage Regulator

FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm

1.5A Very L.D.O Voltage Regulator LM29150/29151/29152

DG2302. High-Speed, Low r ON, SPST Analog Switch. Vishay Siliconix. (1-Bit Bus Switch with Level-Shifter) RoHS* COMPLIANT DESCRIPTION FEATURES

256K (32K x 8) Static RAM

+5 V Powered RS-232/RS-422 Transceiver AD7306

Features. Applications

LM2704 Micropower Step-up DC/DC Converter with 550mA Peak Current Limit

AP KHz, 2A PWM BUCK DC/DC CONVERTER. Description. Pin Assignments V IN. Applications. Features. (Top View) GND GND. Output AP1509 GND GND

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

High-Speed, Low r ON, SPST Analog Switch (1-Bit Bus Switch)

VN05N. High side smart power solid state relay PENTAWATT. Features. Description

DALLAS DS1233 Econo Reset. BOTTOM VIEW TO-92 PACKAGE See Mech. Drawings Section on Website

STM6315. Open drain microprocessor reset. Features

1-Mbit (128K x 8) Static RAM

STCS A max constant current LED driver. Features. Applications. Description

STCS1A. 1.5 A max constant current LED driver. Features. Applications. Description

High Common-Mode Rejection. Differential Line Receiver SSM2141. Fax: 781/ FUNCTIONAL BLOCK DIAGRAM FEATURES. High Common-Mode Rejection

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

SG6516 PC Power Supply Supervisors

28 V, 56 m, Load Switch with Programmable Current Limit and Slew Rate Control

CMOS Switched-Capacitor Voltage Converters ADM660/ADM8660

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

SC728/SC729. 2A Low Vin, Very Low Ron Load Switch. POWER MANAGEMENT Features. Description. Applications. Typical Application Circuit SC728 / SC729

LM56 Dual Output Low Power Thermostat

WHITE LED STEP-UP CONVERTER. Features

STCS2A. 2 A max constant current LED driver. Features. Applications. Description

HT9170 DTMF Receiver. Features. General Description. Selection Table

EVALUATION KIT AVAILABLE Broadband, Two-Output, Low-Noise Amplifier for TV Tuner Applications MAX2130. Maxim Integrated Products 1

NE555 SA555 - SE555. General-purpose single bipolar timers. Features. Description

NE555 SA555 - SE555. General-purpose single bipolar timers. Features. Description

LM75 Digital Temperature Sensor and Thermal Watchdog with Two-Wire Interface

Supertex inc. HV Channel High Voltage Amplifier Array HV256. Features. General Description. Applications. Typical Application Circuit

CAT4109, CAV Channel Constant-Current RGB LED Driver with Individual PWM Dimming

Theory of Operation. Figure 1 illustrates a fan motor circuit used in an automobile application. The TPIC kω AREF.

SG6520 FEATURES DESCRIPTION TYPICAL APPLICATION. Product Specification. PC Power Supply Supervisors

Features. Ordering Information. * Underbar marking may not be to scale. Part Identification

1.5A Ultra Low Dropout Linear Regulator TJ3965

GT Sensors Precision Gear Tooth and Encoder Sensors

DM74LS112A Dual Negative-Edge-Triggered Master-Slave J-K Flip-Flop with Preset, Clear, and Complementary Outputs

INTEGRATED CIRCUITS. 74LVC08A Quad 2-input AND gate. Product specification IC24 Data Handbook Jun 30

DATA SHEET. TDA1543 Dual 16-bit DAC (economy version) (I 2 S input format) INTEGRATED CIRCUITS

High-Speed, 5 V, 0.1 F CMOS RS-232 Drivers/Receivers ADM222/ADM232A/ADM242

INTEGRATED CIRCUITS. NE558 Quad timer. Product data Supersedes data of 2001 Aug Feb 14

CURRENT LIMITING SINGLE CHANNEL DRIVER V OFFSET. Packages

+3.3V/+5V, 8-Channel Relay Drivers with Fast Recovery Time and Power-Save Mode

MAX6877/MAX6878/MAX6879

DS2401 Silicon Serial Number

7 OUT1 8 OUT2 9 OUT3 10 OUT4 11 OUT5 12 OUT6 13 OUT7 14 OUT8 15 OUT9 16 OUT10 17 OUT11 18 OUT12 19 OUT13 20 OUT14 21 OUT15 22 OUT16 OUT17 23 OUT18

30V Internal Switch LCD Bias Supply

STLM20. Ultra-low current 2.4 V precision analog temperature sensor. Features. Applications

LM117 LM317A LM317 3-Terminal Adjustable Regulator

DM74LS47 BCD to 7-Segment Decoder/Driver with Open-Collector Outputs

VNP5N07 "OMNIFET": FULLY AUTOPROTECTED POWER MOSFET

Cold-Junction Compensated Thermocouple-to-Digital Converter

AP KHz, 3A PWM BUCK DC/DC CONVERTER. Pin Assignments. Description. Features. Applications. ( Top View ) 5 SD 4 FB 3 Gnd 2 Output 1 V IN

LM138 LM338 5-Amp Adjustable Regulators

Transcription:

EVALUATION KIT AVAILABLE MAX9621 General Description The MAX9621 is a continuation of the Maxim family of Hall-effect sensor interfaces that already includes the MAX9921. The MAX9621 provides a single-chip solution to interface two 2-wire Hall-effect sensors to low-voltage microprocessors (FP) through either a digital output for Hall-effect switches or an analog output for linear information or both. The MAX9621 protects the Hall sensors from supply transients up to 60V at the BAT supply. Normal operating supply voltage ranges from 5.5V to 18V. If the BAT supply rises above 18V, the MAX9621 shuts off the current to the Hall sensors. When a short-to-ground fault condition is detected, the current to the Hall input is shut off and the condition is indicated at the analog output by a zerocurrent level and a high digital output. The MAX9621 provides a minimum of 50Fs blanking time following Hall sensor power-up or restart. The opendrain digital outputs are compatible with logic levels up to 5.5V. The MAX9621 is available in a 3mm x 5mm, 10-pin FMAXM package and is rated for operation in the -40NC to +125NC temperature range. Window Lifters Seat Movers Electric Sunroofs Seatbelt Buckles Door Power Locks Ignition Key Steering Column Speed Sensing Applications Features S Provides Supply Current and Interfaces to Two 2-Wire Hall-Effect Sensors S 5.5V to 18V Operating Voltage Range S Protects Hall Sensors Against Up to 60V Supply Transients S Low-Power Shutdown for Power Saving S Filtered Digital Outputs S Analog Output Mirrors the Hall Sensor Current S Hall Inputs Protected from Short to Ground S Hall Sensor Blanking Following Power-Up and Restart from Shutdown and Short to Ground S Operates with ±3V Ground Shift Between the Hall Sensor and the MAX9621 S ±2kV Human Body Model ESD and ±200V Machine Model ESD at All Pins S 3mm x 5mm, 10-Pin µmax Package Ordering Information PART TEMP RANGE PIN-PACKAGE MAX9621AUB+T -40NC to +125NC 10 FMAX MAX9621AUB/V+ -40NC to +125NC 10 FMAX +Denotes a lead(pb)-free/rohs-compliant package. T = Tape and reel. /V denotes an automotive qualified part. ISET IN1 REFERENCE REF Functional Diagram BAT REF BAT SLEEP-MODE CONTROL FILTER 10kI SLEEP AOUT1 DOUT1 INPUT SHORT DETECTION BAT MAX9621 Typical Application Circuit appears at end of data sheet. IN2 REF FILTER AOUT2 DOUT2 µmax is a registered trademark of Maxim Integrated Products, Inc. GND For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim s website at www.maximintegrated.com. 19-5024; Rev 1; 9/11

ABSOLUTE MAXIMUM RATINGS BAT to GND...-0.3V to +60V ISET to BAT...-2.0V to +0.3V IN1, IN2 to GND... -3V to lower of +60V or (V BAT + 1V) AOUT1, DOUT1, AOUT2, DOUT2, SLEEP to GND...-0.3V to +6V Short-Circuit Duration AOUT1, DOUT1, AOUT2, DOUT2 to GND or to 5.5V (individually)...continuous Current In to IN1, IN2... ±100mA Current In to Any Other Pin... ±20mA Continuous Power Dissipation for a Single-Layer Board (T A = +70NC) 10-Pin µmax (derate 5.6mW/NC) above +70NC...444.4mW Continuous Power Dissipation for a Multilayer Board (T A = +70NC) 10-Pin µmax (derate 8.8mW/NC) above +70NC...707.3mW Operating Temperature Range... -40NC to +125NC Junction Temperature...+150NC Storage Temperature Range... -65NC to +160NC Lead Temperature (soldering, 10s)...+300NC Soldering Temperature (reflow)...+260nc Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. DC ELECTRICAL CHARACTERISTICS (V BAT = 13.6V, V SLEEP = 5V, IN1 = IN2 = no connection, R SET = 61.9kI to BAT, R PU = 10kI at DOUT1 and DOUT2, R L = 5kI to GND at AOUT1 and AOUT2, unless otherwise noted, T A = -40NC to +125NC. Typical values are at T A = +25NC.) (Note 1) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS GENERAL Guaranteed by functional test of I IH, I IL, BAT Supply Range V BAT and G EI 5.5 18 V BAT Supply Current I BAT Normal mode 1 ma I SD VSLEEP = 0V 1 10 FA V BAT = 5.5V, at IN1 and IN2, I IN = -14mA 0.59 1.26 Hall Input Voltage Dropout V DO V V BAT = 5.5V, at IN1 and IN2, 0.86 1.86 I IN = -20mA ESD Protection Machine Model ±200 Human Body Model ±2000 V INPUT THRESHOLDS FOR DOUT1, DOUT2 SWITCHING Input Current for Output High R SET = 95.3kI -7.7 I IH (Note 2) R SET = 52.3kI -14 ma Input Current for Output Low R SET = 95.3kI -5 I IL (Note 2) R SET = 52.3kI -9 ma Input Current Hysteresis for High/Low Detection Channel-to-Channel Input Threshold Variation I IN_HYS Peak-to-peak as percent of average high/ 8 % low threshold (Note 2) High threshold 0.02 ma Low threshold 0.02 Short-Circuit Current Limit I SC condition, Hall input reverts to -50FA when -20 ma A short to GND is not a sustained detected (Note 2) AOUT1, AOUT2 ANALOG OUTPUTS Current Gain for AOUT1 and AOUT2 Outputs G I -18mA P IIN P -2mA 0.05 ma/ma Current Gain Error for AOUT1 and AOUT2 Outputs G EI I IN = -5mA, -14mA 0.2 ±1.7 % 2 Maxim Integrated

DC ELECTRICAL CHARACTERISTICS (continued) (V BAT = 13.6V, V SLEEP = 5V, IN1 = IN2 = no connection, R SET = 61.9kI to BAT, R PU = 10kI at DOUT1 and DOUT2, R L = 5kI to GND at AOUT1 and AOUT2, unless otherwise noted, T A = -40NC to +125NC. Typical values are at T A = +25NC.) (Note 1) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Inferred from measurements at Input Referred Current Offset I OS I IN = -5mA, -14mA -120 +120 FA V BAT = 5.5V, I IN = -14mA 0.85 1.6 AOUT_ Dropout Voltage for 5% current V reduction I IN = -20mA 1.09 1.75 AOUT_ Output Impedance 500 MI LOGIC I/O (DOUT1, DOUT2) Output-Voltage Low DOUT1, DOUT2 V OL Sink current = 1mA 0.4 V Three-State Output Current DOUT1, DOUT2 I OZ VSLEEP = 0V, 0V P V DOUT_ P 5V ±1 FA SLEEP Input-Voltage High V IH 2.0 V Input-Voltage Low V IL 0.8 V Input Resistance to GND R IN 50 100 ki AC TIMING CHARACTERISTICS Shutdown Delay from SLEEP Low to IN_ Shutoff IN_, Blanking Time at Hall Sensor Power-Up IN_, Current Ramp Rate After Turn-On Delay from IN_ to DOUT_ (Filter Delay) t SHDN t BL I IH = -14mA to GND, time from SLEEP low to IN_ drop 500mV, C L = 20pF I IH = -14mA to GND, time from V IN_ = 500mV until DOUT_ high, C L = 20pF (Notes 2, 3) 33 40 46 Fs 76 89 103 Fs t RAMP IN_ = GND (Note 2) 3.6 5 6.7 ma/fs t DEL From I IH to I IL or from I IL to I IH, C L = 20pF, Figure 1 (Note 2) 10.8 13.5 16 Fs Delay Difference Between Rising and Falling Edges of Both Channels t DM C HALL-BYPASS = 0.01FF, I IH = -11.5mA and I IL = -7.5mA, C L = 20pF 1 Fs Delay Difference Between Channels Maximum Frequency on Hall Inputs Maximum Analog Output Current During Short-to-GND Fault IN_ Pulse Length Rejected by Filter to DOUT_ t CC f MAX C HALL-BYPASS = 0.01FF, I IH = -11.5mA and I IL = -7.5mA, C L = 20pF C HALL-BYPASS = 0.01FF, I IH = -11.5mA and I IL = -7.5mA, C L = 20pF (Note 2) 500 ns 34 39 khz I MAO -1.4 ma P R Figure 2 (Note 2) 7.8 11.5 14.6 Fs Note 1: All DC specifications are 100% production tested at T A = +25 C. AC specifications are guaranteed by design at T A = +25 C. Note 2: Parameters that change with the value of the R SET resistor: I IH, I IL, I IN_HYS, I SC, t BL, t RAMP, t DEL, f MAX, and P R. Note 3: Following power-up or startup from sleep mode, the start of the blanking period is delayed 20Fs. Maxim Integrated 3

Timing Diagrams 14mA IN1 7mA 0mA 0.7mA AOUT1 0.35mA HALL SENSOR OPEN HALL SENSOR OPEN APPROXIMATELY 100mA SHORT CIRCUIT APPROXIMATELY 100mA 5mA/µs APPROXIMATELY 1.4mA RESTART 5mA/µs DOUT1 0mA 5V 0V t DEL t DEL Figure 1. Timing Diagram 14mA IN_ 7mA 0mA P R P R DOUT_ 5V t DEL t DEL 0V Figure 2. Hall Input Pulse Rejection 4 Maxim Integrated

Typical Operating Characteristics (V BAT = 13.6V, R SET = 61.9kI, R L = 5kI to GND at AOUT_, V SLEEP = 5V, T A = +25NC, unless otherwise noted.) 0.9 0.8 BAT SUPPLY CURRENT vs. V BAT IN OPERATING MODE T A = -40NC MAX9621 toc01 0.9 0.8 BAT SUPPLY CURRENT vs. V BAT IN OPERATING MODE T A = +25NC MAX9621 toc02 0.9 0.8 BAT SUPPLY CURRENT vs. V BAT IN OPERATING MODE T A = +125NC MAX9621 toc03 BAT CURRENT (ma) 0.7 0.6 BAT CURRENT (ma) 0.7 0.6 BAT CURRENT (ma) 0.7 0.6 0.5 0.5 0.5 0.4 19.0 19.5 20.0 20.5 21.0 0.4 19.0 19.5 20.0 20.5 21.0 0.4 19.0 19.5 20.0 20.5 21.0 1.0 BAT SUPPLY CURRENT vs. V BAT IN OPERATING MODE T A = -40NC MAX9621 toc04 1.0 BAT SUPPLY CURRENT vs. V BAT IN OPERATING MODE T A = +25NC MAX9621 toc05 1.0 BAT SUPPLY CURRENT vs. V BAT IN OPERATING MODE T A = +125NC MAX9621 toc06 0.8 0.8 0.8 BAT CURRENT (ma) 0.6 BAT CURRENT (ma) 0.6 BAT CURRENT (ma) 0.6 0.4 0.4 0.4 0.2 0 10 20 30 40 50 60 0.2 0 10 20 30 40 50 60 0.2 0 10 20 30 40 50 60 BAT CURRENT (na) 200 180 160 140 120 100 80 60 40 20 BAT SUPPLY CURRENT vs. V BAT IN SHUTDOWN MODE T A = +125 C T A = +25 C AND -40 C MAX9621 toc07 HALL INPUT CURRENT (ma) 10.4 10.2 10.0 9.8 9.6 9.4 9.2 9.0 HALL INPUT CURRENT THRESHOLDS FOR HIGH/LOW vs. TEMPERATURE LOW TO HIGH HIGH TO LOW MAX9621 toc08 HALL INPUT CURRENT (ma) 10.50 10.25 10.00 9.75 9.50 9.25 9.00 8.75 HALL INPUT CURRENT THRESHOLDS vs. V BAT LOW TO HIGH HIGH TO LOW MAX9621 toc09 0 0 20 40 60 80 8.8-40 -25-10 5 20 35 50 65 80 95 110 125 TEMPERATURE ( C) 8.50 5.5 8.0 10.5 13.0 15.5 18.0 Maxim Integrated 5

Typical Operating Characteristics (continued) (V BAT = 13.6V, R SET = 61.9kI, R L = 5kI to GND at AOUT_, V SLEEP = 5V, T A = +25NC, unless otherwise noted.) HALL INPUT CURRENT (ma) 16 14 12 10 8 6 HALL INPUT CURRENT THRESHOLDS vs. ISET RESISTOR LOW TO HIGH HIGH TO LOW MAX9621 toc10 IN_ BLANKING TIME (µs) 100 95 90 85 80 75 70 65 INPUT BLANKING TIME AT RESTART FROM SLEEP MODE (OR POWER-UP) vs. TEMPERATURE MAX9621 toc11 CURRENT RATE (ma/us) 10 9 8 7 6 5 4 3 IN-CURRENT RAMP RATE AFTER TURN-ON vs. TEMPERATURE MAX9621 toc12 4 50 60 70 80 90 100 RESISTANCE (ki) 60-40 -25-10 5 20 35 50 65 80 95 110 125 TEMPERATURE ( C) 2-40 -25-10 5 20 35 50 65 80 95 110 125 TEMPERATURE ( C) DELAY (µs) DELAY FROM IN_ TO DOUT_ (FILTER DELAY) vs. TEMPERATURE 20 15 10 5 MAX9621 toc13 DELAY DIFFERENCE (ns) 900 700 500 300 100 DELAY DIFFERENCE BETWEEN CHANNELS vs. TEMPERATURE MAX9621 toc14 FREQUENCY (khz) 60 50 40 30 20 MAXIMUM FREQUENCY ON HALL INPUTS vs. TEMPERATURE IN1 IN2 MAX9621 toc15 0-50 -25 0 25 50 75 100 125 TEMPERATURE (NC) -100-50 -25 0 25 50 75 100 125 TEMPERATURE (NC) 10-50 -25 0 25 50 75 100 125 TEMPERATURE (NC) PULSE LENGTH (µs) 20 18 16 14 12 10 8 6 4 2 IN_ PULSE LENGTH REJECTED BY FILTER TO DOUT_ vs. TEMPERATURE NEGATIVE PULSE POSITIVE PULSE 0-50 -25 0 25 50 75 100 125 TEMPERATURE (NC) MAX9621 toc16 DROPOUT VOLTAGE (V) 1.15 1.05 0.95 0.85 0.75 0.65 0.55 0.45 0.35 INPUT DROPOUT VOLTAGE vs. TEMPERATURE V BAT = 5.5V I IN1 = -14mA 0.25-45 -25-10 5 20 35 50 65 80 95 110 125 TEMPERATURE ( C) MAX9621 toc17 INPUT DROPOUT VOLTAGE (V) 1.15 1.05 0.95 0.85 0.75 0.65 0.55 0.45 0.35 I IN1 = -14mA INPUT DROPOUT VOLTAGE vs. V BAT T A = +125 C T A = +25 C T A = -40 C 0.25 5.50 8.00 10.50 13.00 15.50 18.00 V BAT (V) MAX9621 toc18 6 Maxim Integrated

Typical Operating Characteristics (continued) (V BAT = 13.6V, R SET = 61.9kI, R L = 5kI to GND at AOUT_, V SLEEP = 5V, T A = +25NC, unless otherwise noted.) CURRENT GAIN (ma/ma) 0.07 0.06 0.05 0.04 CURRENT GAIN vs. SUPPLY VOLTAGE MAX9621 toc19 CURRENT GAIN (ma/ma) 0.07 0.06 0.05 0.04 CURRENT GAIN vs. TEMPERATURE MAX9621 toc20 0.03 5.50 8.00 10.50 13.00 15.50 18.00 SUPPLY VOLTAGE (V) 0.03-50 -25 0 25 50 75 100 125 TEMPERATURE (NC) RESPONSE TO SHORT TO GROUND MAX9621 toc21 REENERGIZING OF THE HALL INPUT FROM OPEN-CIRCUIT CONDITION MAX9621 toc22 V IN1 V AOUT1 V IN1 V DOUT1 I IN1 I IN1 V AOUT1 400ns/div 100µs/div STARTUP OF IN_/AOUT_ FROM SHUTDOWN MAX9621 toc23 STARTUP OF IN_/DOUT_ FROM SHUTDOWN MAX9621 toc24 V SLEEP V IN1 V SLEEP V IN1 I IN1 I IN1 V AOUT1 V DOUT1 10µs/div 20µs/div Maxim Integrated 7

Pin Configuration TOP VIEW BAT 1 + 10 SLEEP ISET 2 MAX9621 9 AOUT1 IN1 3 8 DOUT1 IN2 4 7 AOUT2 GND 5 6 DOUT2 µmax PIN NAME FUNCTION 1 BAT Pin Description Battery Power Supply. Connect to the positive supply through an external reverse-polarity diode. Bypassed to GND with a 0.1FF capacitor. 2 ISET 3 IN1 Current Setting Input. Place a 1% resistor (R SET ) between BAT and ISET to set the desired input current threshold range for the DOUT_ outputs. See the Typical Operating Characteristics section for the correct value of R SET for the desired range. Make no other connections to this pin. All routing must have low parasitic capacitance. See the Input Current Thresholds and Short to Ground section. Hall-Effect Sensor Input 1. Supplies current to the Hall sensor and monitors the current level drawn to determine the high/low state of the sensor. Bypass to GND with a 0.01FF capacitor. Connect an unused input to BAT pin. 4 IN2 Hall-Effect Sensor Input 2. Supplies current to the Hall sensor and monitors the current level drawn to determine the high/low state of the sensor. Bypass to GND with a 0.01FF capacitor. Connect an unused input to BAT pin. 5 GND Ground 8 Maxim Integrated

PIN NAME FUNCTION 6 DOUT2 Pin Description (continued) Open-Drain Output. Signal translated from Hall sensor 2. DOUT2 is high when the current flowing out of IN2 exceeds the input current threshold high, and is low when less than the input current threshold low. See Table 1 for output response to operating conditions. 7 AOUT2 8 DOUT1 9 AOUT1 10 SLEEP Analog Current Output. Mirrors the current to the corresponding Hall sensor at IN2. When IN2 has been shut down due to a short to GND a current of zero is supplied to AOUT2. See Table 1 for output response to operating conditions. To obtain a voltage output, connect a resistor from AOUT_ to ground. Open-Drain Output. Signal translated from Hall sensor 1. DOUT1 is high when the current flowing out of IN1 exceeds the input current threshold high, and is low when less than the input current threshold low. See Table 1 for output response to operating conditions. Analog Current Output. Mirrors the current to the corresponding Hall sensor at IN1. When IN1 has been shut down due to a short to GND a current of zero is supplied to AOUT1. See Table 1 for output response to operating conditions. To obtain a voltage output, connect a resistor from AOUT_ to ground. Sleep Mode Input. The part is placed in sleep mode when the SLEEP input is low for more than 40Fs. If the SLEEP input is low for less than 20Fs and then goes high, the part restarts any Hall input that has been shut off due to a detected short to GND. Any Hall input that is operational is not affected when SLEEP is cycled low for less than 20Fs. There is an internal 100kI pulldown resistance to GND. Detailed Description The MAX9621, an interface between two 2-wire Halleffect sensors and a low-voltage microprocessor, supplies and monitors current through IN1 and IN2 to two Hall sensors. The MAX9621 complements Maxim s existing family of Hall-effect sensor interfaces that includes the MAX9921. The MAX9621 provides two independent channels with two outputs for each channel, a digital output, and an analog output. The digital outputs (DOUT1 and DOUT2) are open-drain and indicate a logic level that corresponds to the Hall sensor status. DOUT1 or DOUT2 outputs high when the current out of IN1 or IN2, respectively, exceeds the high-input current threshold. DOUT1 or DOUT2 outputs low when the current flowing out of IN1 or IN2, respectively, is lower than the low-input current threshold. DOUT1 and DOUT2 provide a time domain output filter for robust noise immunity. See Figure 2. The analog outputs (AOUT1 and AOUT2) mirror the current flowing out to the corresponding inputs IN1 and IN2 with a nominal gain of 0.05mA/mA. Hall Sensor Protection from Supply Transients The MAX9621 protects the hall sensors from supply transients by shutting off current at IN1 and IN2 when the BAT voltage is 18V. The digital outputs go low and analog outputs have zero output current. When VBAT returns to the proper operating range, both inputs restart following a blanking cycle. Maxim Integrated 9

Table 1. AOUT_/DOUT_ Truth Table CONDITION AOUT_ DOUT_ IN_ Short to GND 0 High-Z IN_ Short to BAT or IN_ Open 0 Low* SLEEP Low 0 High-Z V BAT > 18V 0 Low* *If IN_ is already shorted to BAT or open during power-up, DOUT_ goes to high-z until IN_ is loaded. Hall Input Short-to-Battery Condition The MAX9621 interprets a short to battery when the voltage at IN1 or IN2 is higher than VBAT - 100mV. The digital outputs go low and the analog outputs are set to zero output current. If IN1 or IN2 is more than 1V above VBAT, it back-drives current into BAT. The MAX9621 restarts the Hall inputs when the Hall input is loaded again. Hall Input Short to Ground The Hall input short-to-ground fault is effectively a latched condition if the input remains loaded by the Hall switch. The current required to power the Hall switch is shut off and only a 50µA pullup current remains. The Hall input can be manually reenergized or it can be reenergized by the µp. A 10µs to 20µs negative pulse at SLEEP restarts with a blanking cycle any Hall input that has been shut down due to the short-to-ground condition. During startup or restart, it is possible for a Hall input to charge up an external capacitance of 0.02µF without tripping into a short-to-ground latched state. During the short-to-ground fault, DOUT1 and DOUT2 are high impedance (pulled high by the pullup resistors), while AOUT1 and AOUT2 are set to zero-output current. Manual Method for Reenergizing Hall Sensor and Means for Diagnosing an Intermittent Hall Sensor Connection Figure 3 shows the behavior of the MAX9621 when a Hall input is open. Figure 4 shows the behavior of the MAX9621 when the open input is reconnected to a Hall sensor. Figures 3 and 4 demonstrate how a short-toground Hall input can be reset. Resetting a short-toground Hall input involves three steps: 1) Relieve the short to ground at the Hall sensor. 2) Disconnect the Hall input from the Hall sensor (openinput fault condition). 3) Reconnect the Hall input to the Hall sensor. The MAX9621 restarts the Hall input with a blanking cycle. If the Hall input is disconnected from the Hall sensor for 10ms, it allows the Hall input to be pulled up by the 50FA pullup current to register the open-input fault condition. Reconnecting the Hall input to the Hall sensor restarts the Hall input with a blanking cycle. This provides a manual means of reenergizing a Hall input without having to resort to the FP to restart it. This also demonstrates the behavior of an intermittent connection to a Hall sensor. 14V V IN_ 0V HALL INPUT SHORT-TO- GROUND FAULT 5mV/ms V BAT - 25mV HALL INPUT OPEN-CIRCUIT FAULT TIME HALL INPUT DISCONNECTED FROM SENSOR I IN_ 50µA 0A TIME Figure 3. Hall Input Ramps to Open-Circuit Fault When a Short to Ground Is Relieved 10 Maxim Integrated

14V V BAT - 25mV V IN_ 8V V BAT - 500mV 0V TIME 11.5mA I IN_ 5mA/µs HALL INPUT RECONNECTED TO HALL SENSOR 0A Figure 4. Hall Input Reenergized When Open Input Is Reconnected to Hall Sensor Sleep Mode Input (SLEEP) The MAX9621 features an active-low SLEEP input. Pull SLEEP low for more than 40Fs to put the device into sleep mode for power saving. In sleep mode, the DOUT1 and DOUT2 outputs are high impedance and are pulled high by pullup resistors. AOUT1 and AOUT2 are set to zero-output current. Hall Input Restart When an input has been shut down due to a short to ground, cycle SLEEP for 10Fs to 20Fs to restart the input. If the other input is operational it is not affected. The restart happens on the rising edge of SLEEP. Input Current Thresholds and Short to Ground The input current high and low thresholds that determine the logic level of the digital outputs are adjusted by changing the RSET value. When the RSET value changes, the following parameters change as well: IIN_HYS, ISC, tbl, tramp, tdel, fmax, and PR. IIH, IIL, IIN_HYS, ISC, tramp, and fmax are inversely proportional to RSET and decrease as RSET increases. This inverse relationship is linear. For example, a 10% change in (1/RSET) results in a 10% change in current parameters. Conversely, time and delay parameters are linear and directly proportional to RSET, and a 10% change in RSET results in an 10% change in time parameters. The difference between the maximum and minimum threshold current limits is the min/max limit spread, which is greater than the threshold hysteresis. The min/max spread and the hysteresis both change by the same percentage as the mean of the threshold current limits. The following equation is useful for finding the mean of the threshold current limits given a value of RSET resistance: TIME 1 I = I0 + I 0 R m < ( ) I is the mean of the threshold current limits, R is the value of the RSET resistance in kω, the constant I0 = 0.03717mA, and the constant m = -0.001668 (1/(kΩ x ma)). The following equation is useful for finding the value of RSET resistance given a mean of the threshold current limits: ( ) Y= Y0 + m II< 0 1 R = Y Y0 = 6.2013 x 10-5 units of (1/kΩ) To compute the typical input current thresholds from the mean input current, it is necessary to obtain the hysteresis. The following equation finds the hysteresis given the mean threshold current, I: H = H0 + k x I (I < 0) where H0 = -0.033463 in ma, and k = -0.08414 in ma/ma. Input current threshold high = I - H/2, input current threshold low = I + H/2. Application Information Use of Digital and Analog Outputs The digital output can be used to provide the FP with an interrupt signal that can represent a Hall sensor change of status. DOUT1 and DOUT2 provide a time domain output filter for robust noise immunity. See Figure 2. The analog output can be connected to an ADC with an appropriate load resistor, and can be used to perform custom diagnostics. Maxim Integrated 11

R MAX9621 X V CC IN_ Figure 5. 3-Wire Hall-Effect Switches Configured as 2-Wire Table 2. A Partial List of Compatible Hall Switches PART NO. MANUFACTURER WEBSITE COMMENTS HAL573-6 Micronas www.micronas.com 2-wire HAL556/560/566 Micronas www.micronas.com 2-wire HAL579/581/584 Micronas www.micronas.com 2-wire A1140/1/2/3 Allegro www.allegromicro.com 2-wire A3161 Allegro www.allegromicro.com 3-wire, optimized for 2-wire use without added resistor TLE4941/C Infineon www.infineon.com 2-wire Sleep Mode Sleep mode can be used in applications that do not continuously require the polling of the Hall sensors. In such cases, the FP can enable the MAX9621 for a short time, check the sensor status, and then put the MAX9621 back to sleep. A blanking period follows upon exiting sleep mode. Remote Ground The MAX9621 targets applications with 2-wire Hall-effect sensors. 2-wire sensors have connections for supply and ground. The output level is signaled by means of modulation of the current drawn by the Hall sensor from its supply. The two threshold currents for high/low are generally in the range of 5mA to 14mA. Thus, the interfacing of a 2-wire sensor is not simply a matter of detecting two voltage thresholds, but requires a coarse current-sense function. Because of the high-side current-sense structure of the MAX9621, the device is immune to shifts between the sensor ground, the ground of the MAX9621 and FP. This ground-shift immunity eliminates the need for a groundconnection wire, allowing a single-wire interface to the Hall sensor. Hall-Effect Sensor Selection The MAX9621 is optimized for use with 2-wire Hall-effect switches or with 3-wire Hall-effect switches connected as 2-wire (Figure 5). When using a 3-wire Hall sensor the resistor R is chosen so that the current drawn by the Hall sensor crosses the MAX9621 current threshold when the magnetic threshold of the Hall sensor is exceeded. A partial list of Hall switches that can be used with the MAX9621 is given in Table 2. Input Current Threshold Precision To get the best input current threshold precision, it is recommended that the RSET resistor be directly connected to the BAT pin. A true Kelvin type connection is best. 12 Maxim Integrated

Typical Application Circuit BATTERY: 5.5V TO 18V OPERATING, 60V WITHSTAND R SET ISET REFERENCE REF BAT 0.1µF R PU 10kI R PU 10kI 1.8V TO 5.5V BAT SLEEP-MODE CONTROL SLEEP 100kI AOUT1 5kI ADC DOUT1 N S ECUCONNECTOR 0.01µF IN1 REF FILTER MICROPROCESSOR REMOTE GROUND INPUT SHORT DETECTION BAT MAX9621 AOUT2 ADC 5kI IN2 N S 0.01µF DOUT2 REF FILTER REMOTE GROUND GND PROCESS: BiCMOS Chip Information Maxim Integrated 13

Package Information For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a +, #, or - in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND PATTERN NO. 10 FMAX U10+2 21-0061 90-0330 α α 14 Maxim Integrated

REVISION NUMBER REVISION DATE DESCRIPTION MAX9621 Revision History PAGES CHANGED 0 11/09 Initial release 1 9/11 Added automotive qualified part 1 Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. Maxim Integrated 160 Rio Robles, San Jose, CA 95134 USA 1-408-601-1000 15 2011 Maxim Integrated Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc.