User Manual FWT01. Multi-functional Wire Testing Instrument. Safety Notes. Warning

Similar documents
162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Manual Ranging MultiMeter

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

User Guide. Model Insulation Tester / Megohmmeter

AutoRanging Digital MultiMeter

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Model UT33A: OPERATING MANUAL Table of Contents (1)

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Model UT201/202: OPERATING MANUAL. Table of Contents

UT202A Operating Manual. Contents

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

System Tel (Telephones) Ltd Fax Web

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

User Guide. 4 wire Earth Resistance Tester Model GRT300

12 Volt 30 Amp Digital Solar Charge Controller

User s Manual Before using the inverter, you need to read and save the safety instructions.

Square D Clipsal C-Bus Network Analyzer

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

SPL 2-00/-01 OPERATION INSTRUCTIONS

User s Manual MXH-BT600E BLUETOOTH WIRELESS HEADPHONE

User's Guide. True RMS Industrial Multimeter

Adjustment functions for both span and shift have been incorporated

7 FUNCTION DIGITAL MULTIMETER

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

Model 1756 Test Lead Kit

Table of Contents. Page

LED BAR 126 / 252 RGB. Owner s Manual LED BAR RGB

323/324/325. Calibration Manual. Clamp Meter

i410/i1010 AC/DC Current Clamp

Radio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions)

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

INFRARED QUARTZ WALL HEATER

19 LED Tube Controller ORDERCODE 41003

12-Volt 10-Amp Regulated Power Supply

Wireless Powerlink II Receiver Set Active

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Achat 115MA full-range speaker. user manual

VOICE RECORDING SYSTEM ISDN PRI / BRI

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

TIG INVERTER INSTRUCTION MANUAL

GLOLAB Universal Telephone Hold

Model UT58A/B/C: OPERATING MANUAL

15GAL STEEL OIL DRAIN WITH 110V PUMP

Multi Media Cable Tester TM-901N/TM-902/TM-903

Model UT713 OPERATING MANUAL

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

ADM1TE 5/30A DIN rail single phase two wire energy meter

Battery charger. Art.no Model CB5-5L-BS1 ENGLISH SVENSKA NORSK SUOMI. Ver Original instructions

DLP-PU/E Instruction Manual

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

FC6 FOOT CONTROLLER OWNER S MANUAL

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Seven function digital multimeter

QLINK User Manual Stereo Audio Transmitter

Instructions A Amp AC/DC Current Probe

5 in 1 Cable Tester RTK-T05 User Manual

PROFESSIONAL WIRELESS DMX CONTROLLER USER S MANUAL EWDMXSYSTEM

AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks

12. Inspection and Maintenance

Hygro-Thermometer + InfraRed Thermometer Model RH101

Odyssey of the Mind Technology Fair. Simple Electronics

User's Guide Integrating Sound Level Datalogger Model

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

Modular I/O System Analog and Digital Interface Modules

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

How To Use A Power Supply Unit (Upu)

MEGGER Insulation & Low Resistance Tester

Model 70A00-1. GSM Cellular Communications Center

Multipurpose LCD Display Cable Test & Inspection Instrument

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

SCHWINTEK IN-WALL SLIDEOUT TROUBLESHOOTING AND COMPONENT REPLACEMENT

Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide

Instruction manual for Firstline FCS12000CH

User s Manual AURORA 1.2K/2.2K

24 Wide Screen LED Monitor with HDMI

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

10 Multimeter. Users Manual

Battery Power Inverters

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

13 Watt PORTABLE SOLAR POWER KIT

Online UPS. PowerWalker VFI 1000R/1U

Model UT60A: OPERATING MANUAL. Table of Contents. Page

400 Amp Rechargeable Jump Start System RAC-HP082

3000W Power Inverter

ReSound Unite TV FREQUENTLY ASKED QUESTIONS. Setup & Configuration. Use & Operation. Troubleshooting

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

NFC Communication Tray Model: HHX-IT3-Z

Cable Tester Pro ORDERCODE D1909

Tone Hammer 500. Owners Manual. Manual Version 1.0

Transcription:

Safety Notes FWT01 Multi-functional Wire Testing Instrument Warning Read carefully this manual to avoid electric shock, burning or personal injury. Caution: Cases which could result in instrument damage or wrong test results. Warning: Cases or actions which could result in personal injury to the users. Warning There is danger of electric shock, serious injury or death caused by touching electrical appliance. To avoid personal injury or death caused by electric shock, you should strictly follow this manual. Read all contents included in this manual User Manual Use this product in accordance with this manual, or else, protection function provided by this product will be out of service or weakened. Do not use testing line that is damaged or has bare metal. Do not use damaged product such as the case cracks. Do not use the product in electrical storm, damp or

thunderstorm environments. Do not use the product to test cable line that has strong current (e.g. 22V supply line) Do not use the product around inflammable gas, high dust or vapor environments. Do not connect the product to power supply with a voltage Overview This product is a multi-functional handheld cable testing tool. It has wide application with reinforced cable types and multiple functions, which is a necessary testing tool for telecommunication engineering, wiring engineering and network maintenance personnel. exceeding test working voltage Do not use the product with missing or wrongly installed battery back cover. Must separate testing line from the tested line before the Main Functions battery aback cover is opened. Do not try to repair this product. User-replaceable parts are not incorporated in this product. For your safety, keep in mind safety first. Electric shock is possibly caused if voltage exceeds 30V AC or 60V DC. Apply proper personal safety equipments, such as safety glasses, mask, insulation gloves, insulation shoes as well as insulation pad, etc. Do not make yourself grounded when working on live power lines. Always connect grounding line with null line when using alligator clip testing line or adapter jumper.

Cable hunting: Directly hunt the cable with RJ11, RJ45 and BNC terminal and other metal leads through adaptor. When cable is hunted, there is no need to strip off cable sheath, which is easy and quick to judge the location of breakpoint in cable. It can directly hunt cable when weak current equipment is turned on, such as Ethernet switch, router. Test network cable: It can fully test the line sequence of network cable, open circuit, short-circuit, miswire, reverse connection and splitpairs. Test line level, positive and negative polarity. Test the status of telephone line: It can test the working status of telephone line (idle, ringing, and off-hook) and judge TIP or RING line. Check lead continuity. Test the connection between network cable and switch port. It provides low voltage prompt function and the receiver has installed spotlight. CAT II CAT III CAT IV Important safety information. Please read this manual before use. Wrong use may lead to the equipment or its components are damaged. Grounding Double insulation protection In compliance with EU(European Union) directives Measurement category II is applicable to test and measuring circuits connected directly to utilization points (socket outlets and similar points) of the low voltage mains installation. Measurement category III is applicable to test and measuring circuits connected to the distribution part of the building s low voltage mains installation. Measurement category IV is applicable to test and measuring circuits connected at the source of the building s low voltage mains installation. Symbol Instruction

Error indicator light: It lights up when there is error tested in network cable. SHORT: short connection error indicator light; MISWIRE: Instruction of Instrument Parts miswire error indicator light; REVERSED: reverse connection error indicator light; SPLITPAIRS: splitpairs error indicator light. TEST button: Start/stop button to start or stop the network cable test. CONT status light: It lights up when circuit is connected. It is brighter if impedance is smaller in circuit. Function switch: Select measurement function of the instrument. CONT: Continuous or network cable on-line test function gears. : Network cable function test, telephone line status test and level test function gears. : Emitting audio function gears. Power light: It lights up when instrument is power on and flashes when it has under voltage. RJ45 terminal on emitter: Standard RJ45 network terminal that is used to hunt, proofread and test network cable. Wiring indicator light: It lights up when network cable is connected, and does not flash if circuit breaks. Error indicator Emitter power switch: To start the instrument, press this switch. Press it again to shut down the instrument. BNC terminal: Standard BNC terminal that is conveniently used to hunt coaxial-cable with BNC terminal. light will flash if error occurs. Scanning speed or audio selection button : Press this

button to change scanning speed in the process of testing network cable. Press this button to change the frequency of emitted audio in the process of hunting cable. Scanning speed or audio selection light: It lights up if it is at quick scanning or high audio frequency. Audio output indicator light: It lights up when audio signal is output. Telephone line status indicator light: It is a double color light. It turns red or green at different working status of telephone or shows different color when level is tested. RJ11 terminal: An terminal used for telephone working status, level test and hunting other metal conducting wire. RJ45 terminal on receiver: Standard RJ45 network terminal used to test network cable. Power switch: Power is on by pressing this switch and off by popping up this switch. Spotlight switch: Spotlight is on by pressing this switch and off by popping up this switch. Test SCAN: Press and hold this button to test the cable. Volume button: Adjust the volume of audio received. Spotlight: To assist the lighting in places with insufficient light. Battery level indicator lamp: Press the test button. The

battery level indicator lamp dims in low battery level. Probe: It gets close to tested line during test and is used to receive audio signal. Headset jack: Connect to headset. Function operation 1. Cable hunting: This function is capable of quickly finding the required line pairs among numerous ones. It is adaptable to network cable with RJ 45 terminal, telephone line with RJ11 terminal and BNC terminal line. The test of other metal lead can be made through adaptor. Methods to operate: starts working. b) Connect one end of tested line to the corresponding terminal of emitter (e.g. RJ45, RJ11 and BNC) or connect to RJ11 terminal through adaptor. c) Push function selection switch of emitter to position, TONE indicator lights up, indicating the emitter starts to send audio signal to the line to be tested. d) Power on the receiver, hold receiver and press SCAN button to test the other end of tested line (e.g. near line stacking of telephone line distribution cabinet, terminal box, hub, and exchanger). Compare the sound sent by receiver, the linr with the loudest sound close to probe will be the target. e) Adjust the volume of receiver by pressing the volume rotary knob during test, or press the button on emitter to change audio frequency sent by emitter to adapt to real environment. Notes: You can connect headset to the headset jack of receiver to aid test in places where there is loud noise. 2. Test network cable: It tests physical connection status of network cable, such as open circuit, short connection, miswire, reverse connection and splitpairs. Description of fault indication: When fault occurs in line or line pair, the corresponding line or line pair light and fault light will turn on at same time. When all line pairs are correct, line pair indicator lamp will turn on but fault light does not turn on. Open circuit: Some open circuit are not abnormal cases for some types of cable. So this instrument does not set up error indicator lamp for open circuit. The typical cables are usually two pairs to four pairs of twisted-pairs. When no twisted-pair is connected to RJ45 socket pin, the line pair indicator light will not turn on. The user can judge which line pair indicator

lights should turn on or not according to actually connected twisted-pairs. Short connection: see below. Miswire: One end of a pair is dislocated. See below. Reverse connection: One end of a pair is reversely connected. See below. Splitpairs: One wire of a pair intertwines on the wire of another pair. See below. emitter. c) Connect another end of network cable to RJ45 socket of receiver. d) Press TEST button to start test. Results will be shown on line pair indicator light and fault indicator light. e) The instrument will continue circulation test until press TEST button again. The test will end. f) Press to change scanning speed during test. For example: When line pair 1-2 and 3-6 are short circuited, the indicator light will show as follows: Line pair indicator light 1-2 and 3-6 is on and short connection indicator light is on. Notes: After one error in line pair is tested by the instrument, it will not continue testing other errors in such line pair. So in every test, only one error can be tested for the tested line pair. Only remove the fault of tested line pair can continue testing other faults in such line pair: Methods to operate: starts working. Push the function switch to network cable function position (in the middle). b) Connect one end of network cable to RJ45 socket of If tested line is disconnected in the process of showing results, the indicator light will not turn off until the results are displayed. 3. Test line level, positive or negative polarity: Use the emitter to test DC level, positive or negative polarity

in circuits. Methods to operate: starts working. Push the function switch to telephone line function position (in the middle). b) Connect RJ11 crystal head terminal of adaptor to RJ11 terminal of emitter. Clamp the tested line with a red-black clip. c) If telephone line status indicator light turns red (in the middle of button switch), the red end is positive, and the black end is negative. If it turns green, the red end is negative and black end is positive. d) The light is brighter when level is higher. The light dims when level is lower. middle of button switch), the red end is TIP line, and the black end is RING line. If it turns green, the red end is RING line and black end is TIP line. Judge whether the telephone line working in idle, ringing or off-hook: starts working. Push the function switch to telephone line function position (in the middle). b) Connect RJ11 crystal head terminal of adaptor to RJ11 terminal of emitter. Clamp the red clip to RING line and black clip to TIP line. c) If telephone line status indicator light turns green (in the middle of button switch), the telephone line is in idle. If it does not light up, it is in off-hook. If it turns 4. Test the status of telephone line: Use the emitter to test the status of telephone line working. Methods to judge TIP or RING line: starts working. Push the function switch to green or red at same time flashes regularly, the telephone line is in ringing. Notes: It may affect other indicator lights when the telephone is in ringing, but which will not affect test results. telephone line function position (in the middle). b) Connect RJ11 crystal head terminal of adaptor to RJ11 terminal of emitter. Clamp the tested line with a red-black clip. c) If telephone line status indicator light turns red (in the 5. Check lead continuity There are two ways to test continuity in circuits. starts working. Push the function switch to CONT

position. Connect RJ11 crystal head terminal of adaptor to RJ11 terminal of emitter. Clamp the tested line with a red-black clip. If CONT light is on, the circuit will be continuous. The light is brighter if impendence is smaller. b) The operation methods are similar with cable hunting function. If the audio is detected by the receiver on TEST button again. The test will end. e) You can press SEL button to change scanning speed in indicator light in the process of test. Notes: If tested line is disconnected in the process of showing results, the indicator light will not turn off until the results are displayed. another outer end of circuit, the circuit will be continuous. 6. Test connection between network cable with exchanger port: It can directly test whether network cable is connected to exchanger in no need of disconnection. Only emitter is required. Methods to operate: starts working. Push the function switch to CONT position. b) Connect RJ45 crystal head terminal of tested line to RJ45 terminal of emitter and another end to RJ45 terminal of exchanger. c) Press TEST button to test. Line pair indicator light will show test results. If the tested line is connected to exchanger, the light will be on, or else, it will be off. d) The instrument will continue circulation test until press 7. Battery undervoltage indication: Undervoltage indication on emitter: When battery of emitter is lower than working voltage, the power light on emitter will flash. In this case, please timely replace battery. Battery voltage indication on receiver: There is a luminous diode on receiver probe, which is dimmed when voltage is low. When the indicator light is very dimmed, set the emitter as cable hunting and working status, approach RJ45 terminal of emitter with receiver probe, and adjust the volume of receiver till maximum. If there is no sound sent by receiver, please timely replace battery. General technical parameters Temperature: Operating:0~40 O C, maximal 80 % relative humidity (non-condensing).

Storage:-10 ~ 50 O C, maximal 80 % relative humidity (non-condensing, battery not included) Altitude:<2000m( meter) 3. Replace new battery with equivalent specification. 4. Install battery cover and tighten the back cover with screwdriver. Anti-explosion rating: IP 40 Distance of emitting signal :>3000m Safety class:iec61010-1 600V CAT III, pollution class II. Battery: emitter 3 x 1.5V/AA; receiver 6F22/9V Size: emitter 125mm x 66mm x 30mm; receiver 210mm x 45mm x 23mm Weight: approx. 95 g for emitter (battery not included); approx. 70 g for receiver (battery not included) Maintenance Do not attempt to repair or service this instrument unless you are qualified to do so and have the relevant calibration, performance test and service instructions. Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or chemical solvents. Replace battery Replace the battery as follows: 1. Screw out the bolts of battery cover with screwdriver. 2. Remove battery cover and old battery.